-
Universal mask for hard X rays
Authors:
David Ceddia,
Alaleh Aminzadeh,
Philip K. Cook,
Daniele Pelliccia,
Andrew M. Kingston,
David M. Paganin
Abstract:
The penetrating power of X rays underpins important applications such as medical radiography. However, this same attribute makes it challenging to achieve flexible on-demand patterning of X-ray beams. One possible path to this goal is ``ghost projection'', a method which may be viewed as a reversed form of classical ghost imaging. This technique employs multiple exposures, of a single illuminated…
▽ More
The penetrating power of X rays underpins important applications such as medical radiography. However, this same attribute makes it challenging to achieve flexible on-demand patterning of X-ray beams. One possible path to this goal is ``ghost projection'', a method which may be viewed as a reversed form of classical ghost imaging. This technique employs multiple exposures, of a single illuminated non-configurable mask that is transversely displaced to a number of specified positions, to create any desired pattern. An experimental proof-of-concept is given for this idea, using hard X rays. The written pattern is arbitrary, up to a tunable constant offset, and its spatial resolution is limited by both (i) the finest features present in the illuminated mask and (ii) inaccuracies in mask positioning and mask exposure time. In principle, the method could be used to make a universal lithographic mask in the hard-X-ray regime. Ghost projection might also be used as a dynamically-configurable beam-sha** element, namely the hard-X-ray equivalent of a spatial light modulator. The underpinning principle can be applied to gamma rays, neutrons, electrons, muons, and atomic beams. Our flexible approach to beam sha** gives a potentially useful means to manipulate such fields.
△ Less
Submitted 28 June, 2023; v1 submitted 18 March, 2023;
originally announced March 2023.
-
Optimizing illumination patterns for classical ghost imaging
Authors:
Andrew M. Kingston,
Lindon Roberts,
Alaleh Aminzadeh,
Daniele Pelliccia,
Imants D. Svalbe,
David M. Paganin
Abstract:
Classical ghost imaging is a new paradigm in imaging where the image of an object is not measured directly with a pixelated detector. Rather, the object is subject to a set of illumination patterns and the total interaction of the object, e.g., reflected or transmitted photons or particles, is measured for each pattern with a single-pixel or bucket detector. An image of the object is then computed…
▽ More
Classical ghost imaging is a new paradigm in imaging where the image of an object is not measured directly with a pixelated detector. Rather, the object is subject to a set of illumination patterns and the total interaction of the object, e.g., reflected or transmitted photons or particles, is measured for each pattern with a single-pixel or bucket detector. An image of the object is then computed through the correlation of each pattern and the corresponding bucket value. Assuming no prior knowledge of the object, the set of patterns used to compute the ghost image dictates the image quality. In the visible-light regime, programmable spatial light modulators can generate the illumination patterns. In many other regimes -- such as x rays, electrons, and neutrons -- no such dynamically configurable modulators exist, and patterns are commonly produced by employing a transversely-translated mask. In this paper we explore some of the properties of masks or speckle that should be considered to maximize ghost-image quality, given a certain experimental classical ghost-imaging setup employing a transversely-displaced but otherwise non-configurable mask.
△ Less
Submitted 7 November, 2022;
originally announced November 2022.
-
Ghost projection. II. Beam sha** using realistic spatially-random masks
Authors:
David Ceddia,
Andrew M. Kingston,
Daniele Pelliccia,
Alexander Rack,
David M. Paganin
Abstract:
Spatial light modulation is important for many scientific and industrial applications. The spatial light modulator and optical data projector both rely on precisely configurable optical elements to shape a light beam. Here we explore an image-projection approach which does not require a configurable beam-sha** element. We term this approach ghost projection on account of its conceptual relation…
▽ More
Spatial light modulation is important for many scientific and industrial applications. The spatial light modulator and optical data projector both rely on precisely configurable optical elements to shape a light beam. Here we explore an image-projection approach which does not require a configurable beam-sha** element. We term this approach ghost projection on account of its conceptual relation to computational ghost imaging. Instead of a configurable beam sha** element, the method transversely displaces a single illuminated mask, such as a spatially-random screen, to create specified distributions of radiant exposure. The method has potential applicability to image projection employing a variety of radiation and matter wave fields, such as hard x rays, neutrons, muons, atomic beams and molecular beams. Building on our previous theoretical and computational studies, we here seek to understand the effects, sensitivity, and tolerance of some key experimental limitations of the method. Focusing on the case of hard x rays, we employ experimentally acquired masks to numerically study the deleterious effects of photon shot noise, inaccuracies in random-mask exposure time, and inaccuracies in mask positioning, as well as adapting to spatially non-uniform illumination. Understanding the influence of these factors will assist in optimizing experimental design and work towards achieving ghost projection in practice.
△ Less
Submitted 14 August, 2022; v1 submitted 18 February, 2022;
originally announced February 2022.
-
Rapidly-converging multigrid reconstruction of cone-beam tomographic data
Authors:
Glenn R. Myers,
Andrew M. Kingston,
Shane J. Latham,
Benoit Recur,
Thomas Li,
Michael L. Turner,
Levi Beeching,
Adrian P. Sheppard
Abstract:
In the context of large-angle cone-beam tomography (CBCT), we present a practical iterative reconstruction (IR) scheme designed for rapid convergence as required for large datasets. The robustness of the reconstruction is provided by the "space-filling" source trajectory along which the experimental data is collected. The speed of convergence is achieved by leveraging the highly isotropic nature o…
▽ More
In the context of large-angle cone-beam tomography (CBCT), we present a practical iterative reconstruction (IR) scheme designed for rapid convergence as required for large datasets. The robustness of the reconstruction is provided by the "space-filling" source trajectory along which the experimental data is collected. The speed of convergence is achieved by leveraging the highly isotropic nature of this trajectory to design an approximate deconvolution filter that serves as a pre-conditioner in a multi-grid scheme. We demonstrate this IR scheme for CBCT and compare convergence to that of more traditional techniques.
△ Less
Submitted 14 March, 2021;
originally announced March 2021.
-
On the Inherent Dose-Reduction Potential of Classical Ghost Imaging
Authors:
Andrew M. Kingston,
Wilfred K. Fullagar,
Glenn R. Myers,
Daishi Adams,
Daniele Pelliccia,
David M. Paganin
Abstract:
Classical ghost imaging is a computational imaging technique that employs patterned illumination. It is very similar in concept to the single-pixel camera in that an image may be reconstructed from a set of measurements even though all imaging quanta that pass through that sample are never recorded with a position resolving detector. The method was first conceived and applied for visible-wavelengt…
▽ More
Classical ghost imaging is a computational imaging technique that employs patterned illumination. It is very similar in concept to the single-pixel camera in that an image may be reconstructed from a set of measurements even though all imaging quanta that pass through that sample are never recorded with a position resolving detector. The method was first conceived and applied for visible-wavelength photons and was subsequently translated to other probes such as x rays, atomic beams, electrons and neutrons. In the context of ghost imaging using penetrating probes that enable transmission measurement, we here consider several questions relating to the achievable signal-to-noise ratio (SNR). This is compared with the SNR for conventional imaging under scenarios of constant radiation dose and constant experiment time, considering both photon shot-noise and per-measurement electronic read-out noise. We show that inherent improved SNR capabilities of ghost imaging are limited to a subset of these scenarios and are actually due to increased dose (Fellgett advantage). An explanation is also presented for recent results published in the literature that are not consistent with these findings.
△ Less
Submitted 2 September, 2020;
originally announced September 2020.
-
Neutron Ghost Imaging
Authors:
Andrew M. Kingston,
Glenn R. Myers,
Daniele Pelliccia,
Filomena Salvemini,
Joseph J. Bevitt,
Ulf Garbe,
David M. Paganin
Abstract:
Ghost imaging is demonstrated using a poly-energetic reactor source of thermal neutrons. The method presented enables position resolution to be incorporated, into a variety of neutron instruments that are not position resolving. In an imaging context, ghost imaging can be beneficial for dose reduction and resolution enhancement. We also demonstrate a super-resolution variant of the method, namely…
▽ More
Ghost imaging is demonstrated using a poly-energetic reactor source of thermal neutrons. The method presented enables position resolution to be incorporated, into a variety of neutron instruments that are not position resolving. In an imaging context, ghost imaging can be beneficial for dose reduction and resolution enhancement. We also demonstrate a super-resolution variant of the method, namely a parallel form of neutron ghost imaging, with the ability to significantly increase the spatial resolution of a pixelated detector such as a CCD or CMOS camera. Extensions of our neutron ghost-imaging protocol are discussed in detail and include neutron ghost tomography, neutron ghost microscopy, dark-field neutron ghost imaging, and isotope-resolved color neutron ghost imaging via prompt gamma-ray bucket detection.
△ Less
Submitted 12 November, 2019;
originally announced November 2019.
-
Ghost Tomography
Authors:
Andrew. M. Kingston,
Daniele Pelliccia,
Alexander Rack,
Margie P. Olbinado,
Yin Cheng,
Glenn R. Myers,
David M. Paganin
Abstract:
Ghost tomography using single-pixel detection extends the emerging field of ghost imaging to three dimensions, with the use of penetrating radiation. In this work, a series of spatially random x-ray intensity patterns is used to illuminate a specimen in various tomographic angular orientations with only the total transmitted intensity being recorded by a single-pixel camera (or bucket detector). T…
▽ More
Ghost tomography using single-pixel detection extends the emerging field of ghost imaging to three dimensions, with the use of penetrating radiation. In this work, a series of spatially random x-ray intensity patterns is used to illuminate a specimen in various tomographic angular orientations with only the total transmitted intensity being recorded by a single-pixel camera (or bucket detector). The set of zero-dimensional intensity readings, combined with knowledge of the corresponding two-dimensional illuminating patterns and specimen orientations, is sufficient for three-dimensional reconstruction of the specimen. The experimental demonstration of ghost tomography is presented here using synchrotron hard x-rays. This result expands the scope of ghost imaging to encompass volumetric imaging (i.e., tomography), of optically opaque objects using penetrating radiation. For hard x-rays, ghost tomography has the potential to decouple image quality from dose rate as well as image resolution from detector performance.
△ Less
Submitted 31 May, 2018;
originally announced June 2018.
-
X-ray ghost tomography: denoising, dose fractionation and mask considerations
Authors:
Andrew M. Kingston,
Glenn R. Myers,
Daniele Pelliccia,
Imants D. Svalbe,
David M. Paganin
Abstract:
Ghost imaging has recently been successfully achieved in the X-ray regime; due to the penetrating power of X-rays this immediately opens up the possibility of X-ray ghost tomography. No research into this topic currently exists in the literature. Here we present adaptations of conventional tomography techniques to this new ghost imaging scheme. Several numerical implementations for tomography thro…
▽ More
Ghost imaging has recently been successfully achieved in the X-ray regime; due to the penetrating power of X-rays this immediately opens up the possibility of X-ray ghost tomography. No research into this topic currently exists in the literature. Here we present adaptations of conventional tomography techniques to this new ghost imaging scheme. Several numerical implementations for tomography through X-ray ghost imaging are considered. Specific attention is paid to schemes for denoising of the resulting tomographic reconstruction, issues related to dose fractionation, and considerations regarding the ensemble of illuminating masks used for ghost imaging. Each theme is explored through a series of numerical simulations, and several suggestions offered for practical realisations of X-ray ghost tomography.
△ Less
Submitted 10 April, 2018;
originally announced April 2018.