-
East Asian VLBI Network Observations of Active Galactic Nuclei Jets: Imaging with KaVA+Tianma+Nanshan
Authors:
Yuzhu Cui,
Kazuhiro Hada,
Motoki Kino,
Bong Won Sohn,
Jongho Park,
Hyun Wook Ro,
Satoko Sawada-Satoh,
Wu Jiang,
Lang Cui,
Mareki Honma,
Zhi Qiang Shen,
Fumie Tazaki,
Tao An,
Ilje Cho,
Guang Yao Zhao,
Xiao Peng Cheng,
Kotaro Niinuma,
Kiyoaki Wajima,
Ying Kang Zhang,
Noriyuki Kawaguchi,
Juan Carlos Algaba,
Shoko Koyama,
Tomoya Hirota,
Yoshinori Yonekura,
Nobuyuki Sakai
, et al. (52 additional authors not shown)
Abstract:
The East Asian very-long-baseline interferometry (VLBI) Network (EAVN) is a rapidly evolving international VLBI array that is currently promoted under joint efforts among China, Japan, and Korea. EAVN aims at forming a joint VLBI Network by combining a large number of radio telescopes distributed over East Asian regions. After the combination of the Korean VLBI Network (KVN) and the VLBI Explorati…
▽ More
The East Asian very-long-baseline interferometry (VLBI) Network (EAVN) is a rapidly evolving international VLBI array that is currently promoted under joint efforts among China, Japan, and Korea. EAVN aims at forming a joint VLBI Network by combining a large number of radio telescopes distributed over East Asian regions. After the combination of the Korean VLBI Network (KVN) and the VLBI Exploration of Radio Astrometry (VERA) into KaVA, further expansion with the joint array in East Asia is actively promoted. Here we report the first imaging results (at 22 and 43 GHz) of bright radio sources obtained with KaVA connected to Tianma 65-m and Nanshan 26-m Radio Telescopes in China. To test the EAVN imaging performance for different sources, we observed four active galactic nuclei (AGN) having different brightness and morphology. As a result, we confirmed that Tianma 65-m Radio Telescope (TMRT) significantly enhances the overall array sensitivity, a factor of 4 improvement in baseline sensitivity and 2 in image dynamic range compared to the case of KaVA only. The addition of Nanshan 26-m Radio Telescope (NSRT) further doubled the east-west angular resolution. With the resulting high-dynamic-range, high-resolution images with EAVN (KaVA+TMRT+NSRT), various fine-scale structures in our targets, such as the counter-jet in M87, a kink-like morphology of the 3C273 jet and the weak emission in other sources, are successfully detected. This demonstrates the powerful capability of EAVN to study AGN jets and to achieve other science goals in general. Ongoing expansion of EAVN will further enhance the angular resolution, detection sensitivity and frequency coverage of the network.
△ Less
Submitted 14 April, 2021; v1 submitted 12 April, 2021;
originally announced April 2021.
-
Inferring clonal composition from multiple tumor biopsies
Authors:
Matteo Manica,
Hyunjae Ryan Kim,
Roland Mathis,
Philippe Chouvarine,
Dorothea Rutishauser,
Laura De Vargas Roditi,
Bence Szalai,
Ulrich Wagner,
Kathrin Oehl,
Karim Saba,
Arati Pati,
Julio Saez-Rodriguez,
Angshumoy Roy,
Donald W. Parsons,
Peter J. Wild,
María Rodríguez Martínez,
Pavel Sumazin
Abstract:
Explicit accounting for copy number alterations can dramatically improve mutation frequency estimates, leading to more accurate phylogeny reconstructions and subclone characterizations.
Explicit accounting for copy number alterations can dramatically improve mutation frequency estimates, leading to more accurate phylogeny reconstructions and subclone characterizations.
△ Less
Submitted 22 November, 2019; v1 submitted 26 January, 2017;
originally announced January 2017.
-
Amplitude Correction Factors of KVN Observations
Authors:
Sang-Sung Lee,
Do-Young Byun,
Chung Sik Oh,
Hyo Ryoung Kim,
Jongsoo Kim,
Taehyun Jung,
Se-** Oh,
Duk-Gyoo Roh,
Dong-Kyu Jung,
Jae-Hwan Yeom
Abstract:
We report results of investigation of amplitude calibration for very long baseline interferometry (VLBI) observations with Korean VLBI Network (KVN). Amplitude correction factors are estimated based on comparison of KVN observations at 22~GHz correlated by Daejeon hardware correlator and DiFX software correlator in Korea Astronomy and Space Science Institute (KASI) with Very Long Baseline Array (V…
▽ More
We report results of investigation of amplitude calibration for very long baseline interferometry (VLBI) observations with Korean VLBI Network (KVN). Amplitude correction factors are estimated based on comparison of KVN observations at 22~GHz correlated by Daejeon hardware correlator and DiFX software correlator in Korea Astronomy and Space Science Institute (KASI) with Very Long Baseline Array (VLBA) observations at 22~GHz by DiFX software correlator in National Radio Astronomy Observatory (NRAO). We used the observations for compact radio sources, 3C 454.3, NRAO 512, OJ 287, BL Lac, 3C 279, 1633+382, and 1510-089, which are almost unresolved for baselines in a range of 350-477 km. Visibility data of the sources obtained with similar baselines at KVN and VLBA are selected, fringe-fitted, calibrated, and compared for their amplitudes. We found that visibility amplitudes of KVN observations should be corrected by factors of 1.10 and 1.35 when correlated by DiFX and Daejeon correlators, respectively. These correction factors are attributed to the combination of two steps of 2-bit quantization in KVN observing systems and characteristics of Daejeon correlator.
△ Less
Submitted 7 September, 2015; v1 submitted 13 July, 2015;
originally announced July 2015.
-
A New Hardware Correlator in Korea: Performance Evaluation using KVN observations
Authors:
Sang-Sung Lee,
Chung Sik Oh,
Duk-Gyoo Roh,
Se-** Oh,
Jongsoo Kim,
Jae-Hwan Yeom,
Hyo Ryoung Kim,
Dong-Gyu Jung,
Do-Young Byun,
Taehyun Jung,
Noriyuki Kawaguchi,
Katsunori M. Shibata,
Kiyoaki Wajima
Abstract:
We report results of the performance evaluation of a new hardware correlator in Korea, the Daejeon correlator, developed by the Korea Astronomy and Space Science Institute (KASI) and the National Astronomical Observatory of Japan (NAOJ). We conducted Very Long Baseline Interferometry (VLBI) observations at 22~GHz with the Korean VLBI Network (KVN) in Korea and the VLBI Exploration of Radio Astrome…
▽ More
We report results of the performance evaluation of a new hardware correlator in Korea, the Daejeon correlator, developed by the Korea Astronomy and Space Science Institute (KASI) and the National Astronomical Observatory of Japan (NAOJ). We conducted Very Long Baseline Interferometry (VLBI) observations at 22~GHz with the Korean VLBI Network (KVN) in Korea and the VLBI Exploration of Radio Astrometry (VERA) in Japan, and correlated the aquired data with the Daejeon correlator. For evaluating the performance of the new hardware correlator, we compared the correlation outputs from the Daejeon correlator for KVN observations with those from a software correlator, the Distributed FX (DiFX). We investigated the correlated flux densities and brightness distributions of extragalactic compact radio sources. The comparison of the two correlator outputs show that they are consistent with each other within $<8\%$, which is comparable with the amplitude calibration uncertainties of KVN observations at 22~GHz. We also found that the 8\% difference in flux density is caused mainly by (a) the difference in the way of fringe phase tracking between the DiFX software correlator and the Daejeon hardware correlator, and (b) an unusual pattern (a double-layer pattern) of the amplitude correlation output from the Daejeon correlator. The visibility amplitude loss by the double-layer pattern is as small as 3\%. We conclude that the new hardware correlator produces reasonable correlation outputs for continuum observations, which are consistent with the outputs from the DiFX software correlator.
△ Less
Submitted 27 March, 2015;
originally announced March 2015.
-
Verification of the Astrometric Performance of the Korean VLBI Network, using comparative SFPR studies with the VLBA at 14/7 mm
Authors:
María J. Rioja,
Richard Dodson,
TaeHyun Jung,
Bong Won Sohn,
Do-Young Byun,
Iván Agudo,
Se-Hyung Cho,
Sang-Sung Lee,
Jongsoo Kim,
Kee-Tae Kim,
Chung Sik Oh,
Seog-Tae Han,
Do-Heung Je,
Moon-Hee Chung,
Seog-Oh Wi,
Jiman Kang,
Jung-Won Lee,
Hyunsoo Chung,
Hyo Ryoung Kim,
Hyun-Goo Kim,
Chang-Hoon Lee,
Duk-Gyoo Roh,
Se-** Oh,
Jae-Hwan Yeom,
Min-Gyu Song
, et al. (1 additional authors not shown)
Abstract:
The Korean VLBI Network (KVN) is a new mm-VLBI dedicated array with capability for simultaneous observations at multiple frequencies, up to 129 GHz. The innovative multi-channel receivers present significant benefits for astrometric measurements in the frequency domain. The aim of this work is to verify the astrometric performance of the KVN using a comparative study with the VLBA, a well establis…
▽ More
The Korean VLBI Network (KVN) is a new mm-VLBI dedicated array with capability for simultaneous observations at multiple frequencies, up to 129 GHz. The innovative multi-channel receivers present significant benefits for astrometric measurements in the frequency domain. The aim of this work is to verify the astrometric performance of the KVN using a comparative study with the VLBA, a well established instrument. For that purpose, we carried out nearly contemporaneous observations with the KVN and the VLBA, at 14/7 mm, in April 2013. The KVN observations consisted of simultaneous dual frequency observations, while the VLBA used fast frequency switching observations. We used the Source Frequency Phase Referencing technique for the observational and analysis strategy. We find that having simultaneous observations results in a superior performance for compensation of all atmospheric terms in the observables, in addition to offering other significant benefits for astrometric analysis. We have compared the KVN astrometry measurements to those from the VLBA. We find that the structure blending effects introduce dominant systematic astrometric shifts and these need to be taken into account. We have tested multiple analytical routes to characterize the impact of the low resolution effects for extended sources in the astrometric measurements. The results from the analysis of KVN and full VLBA datasets agree within 2-$σ$ of the thermal error estimate. We interpret the discrepancy as arising from the different resolutions. We find that the KVN provides astrometric results with excellent agreement, within 1-$σ$, when compared to a VLBA configuration which has a similar resolution. Therefore this comparative study verifies the astrometric performance of KVN using SFPR at 14/7 mm, and validates the KVN as an astrometric instrument.
△ Less
Submitted 17 July, 2014;
originally announced July 2014.
-
VLBI observations of bright AGN jets with KVN and VERA Array (KaVA): Evaluation of Imaging Capability
Authors:
Kotaro Niinuma,
Sang-Sung Lee,
Motoki Kino,
Bong Won Sohn,
Kazunori Akiyama,
Guang-Yao Zhao,
Satoko Sawada-Satoh,
Sascha Trippe,
Kazuhiro Hada,
Taehyun Jung,
Yoshiaki Hagiwara,
Richard Dodson,
Shoko Koyama,
Mareki Honma,
Hiroshi Nagai,
Aeree Chung,
Akihiro Doi,
Kenta Fujisawa,
Myoung-Hee Han,
Joeng-Sook Kim,
Jeewon Lee,
Jeong Ae Lee,
Atsushi Miyazaki,
Tomoaki Oyama,
Kazuo Sorai
, et al. (47 additional authors not shown)
Abstract:
The Korean very-long-baseline interferometry (VLBI) network (KVN) and VLBI Exploration of Radio Astrometry (VERA) Array (KaVA) is the first international VLBI array dedicated to high-frequency (23 and 43 GHz bands) observations in East Asia. Here, we report the first imaging observations of three bright active galactic nuclei (AGNs) known for their complex morphologies: 4C 39.25, 3C 273, and M 87.…
▽ More
The Korean very-long-baseline interferometry (VLBI) network (KVN) and VLBI Exploration of Radio Astrometry (VERA) Array (KaVA) is the first international VLBI array dedicated to high-frequency (23 and 43 GHz bands) observations in East Asia. Here, we report the first imaging observations of three bright active galactic nuclei (AGNs) known for their complex morphologies: 4C 39.25, 3C 273, and M 87. This is one of the initial result of KaVA early science. Our KaVA images reveal extended outflows with complex substructure such as knots and limb brightening, in agreement with previous Very Long Baseline Array (VLBA) observations. Angular resolutions are better than 1.4 and 0.8 milliarcsecond at 23 GHz and 43 GHz, respectively. KaVA achieves a high dynamic range of ~1000, more than three times the value achieved by VERA. We conclude that KaVA is a powerful array with a great potential for the study of AGN outflows, at least comparable to the best existing radio interferometric arrays.
△ Less
Submitted 17 June, 2014;
originally announced June 2014.
-
The First Very Long Baseline Interferometry Image of 44 GHz Methanol Maser with the KVN and VERA Array (KaVA)
Authors:
Naoko Matsumoto,
Tomoya Hirota,
Koichiro Sugiyama,
Kee-Tae Kim,
Mikyoung Kim,
Do-Young Byun,
Taehyun Jung,
James O. Chibueze,
Mareki Honma,
Osamu Kameya,
Jongsoo Kim,
A-Ran Lyo,
Kazuhito Motogi,
Chungsik Oh,
Nagisa Shino,
Kazuyoshi Sunada,
Jaehan Bae,
Hyunsoo Chung,
Moon-Hee Chung,
Se-Hyung Cho,
Myoung-Hee Han,
Seog-Tae Han,
Jung-Wook Hwang,
Do-Heung Je,
Takaaki Jike
, et al. (36 additional authors not shown)
Abstract:
We have carried out the first very long baseline interferometry (VLBI) imaging of 44 GHz class I methanol maser (7_{0}-6_{1}A^{+}) associated with a millimeter core MM2 in a massive star-forming region IRAS 18151-1208 with KaVA (KVN and VERA Array), which is a newly combined array of KVN (Korean VLBI Network) and VERA (VLBI Exploration of Radio Astrometry). We have succeeded in imaging compact mas…
▽ More
We have carried out the first very long baseline interferometry (VLBI) imaging of 44 GHz class I methanol maser (7_{0}-6_{1}A^{+}) associated with a millimeter core MM2 in a massive star-forming region IRAS 18151-1208 with KaVA (KVN and VERA Array), which is a newly combined array of KVN (Korean VLBI Network) and VERA (VLBI Exploration of Radio Astrometry). We have succeeded in imaging compact maser features with a synthesized beam size of 2.7 milliarcseconds x 1.5 milliarcseconds (mas). These features are detected at a limited number of baselines within the length of shorter than approximately 650 km corresponding to 100 Mlambda in the uv-coverage. The central velocity and the velocity width of the 44 GHz methanol maser are consistent with those of the quiescent gas rather than the outflow traced by the SiO thermal line. The minimum component size among the maser features is ~ 5 mas x 2 mas, which corresponds to the linear size of ~ 15 AU x 6 AU assuming a distance of 3 kpc. The brightness temperatures of these features range from ~ 3.5 x 10^{8} to 1.0 x 10^{10} K, which are higher than estimated lower limit from a previous Very Large Array observation with the highest spatial resolution of ~ 50 mas. The 44 GHz class I methanol maser in IRAS 18151-1208 is found to be associated with the MM2 core, which is thought to be less evolved than another millimeter core MM1 associated with the 6.7 GHz class II methanol maser.
△ Less
Submitted 10 June, 2014; v1 submitted 9 June, 2014;
originally announced June 2014.
-
Optical Probing of Electronic Interaction between Graphene and Hexagonal Boron Nitride
Authors:
Gwanghyun Ahn,
Hye Ri Kim,
Taeg Yeoung Ko,
Kyoungjun Choi,
Kenji Watanabe,
Takashi Taniguchi,
Byung Hee Hong,
Sunmin Ryu
Abstract:
Even weak van der Waals (vdW) adhesion between two-dimensional solids may perturb their various materials properties owing to their low dimensionality. Although the electronic structure of graphene has been predicted to be modified by the vdW interaction with other materials, its optical characterization has not been successful. In this report, we demonstrate that Raman spectroscopy can be utilize…
▽ More
Even weak van der Waals (vdW) adhesion between two-dimensional solids may perturb their various materials properties owing to their low dimensionality. Although the electronic structure of graphene has been predicted to be modified by the vdW interaction with other materials, its optical characterization has not been successful. In this report, we demonstrate that Raman spectroscopy can be utilized to detect a few % decrease in the Fermi velocity (vF) of graphene caused by the vdW interaction with underlying hexagonal boron nitride (hBN). Our study also establishes Raman spectroscopic analysis which enables separation of the effects by the vdW interaction from those by mechanical strain or extra charge carriers. The analysis reveals that spectral features of graphene on hBN are mainly affected by change in vF and mechanical strain, but not by charge do** unlike graphene supported on SiO2 substrates. Graphene on hBN was also found to be less susceptible to thermally induced hole do**.
△ Less
Submitted 30 October, 2013;
originally announced October 2013.
-
Quasi-Periodic Nanoripples in Graphene Grown by Chemical Vapor Deposition and Its Impact on Charge Transport
Authors:
Guang-Xin Ni,
Yi Zheng,
Sukang Bae,
Hye Ri Kim,
Alexandre Pachoud,
Young Soo Kim,
Chang-Ling Tan,
Danho Im,
Jong-Hyun Ahn,
Byung Hee Hong,
Barbaros Özyilmaz
Abstract:
The technical breakthrough in synthesizing graphene by chemical vapor deposition methods (CVD) has opened up enormous opportunities for large-scale device applications. In order to improve the electrical properties of CVD graphene grown on copper (Cu-CVD graphene), recent efforts have focussed on increasing the grain size of such polycrystalline graphene films to 100 micrometers and larger. While…
▽ More
The technical breakthrough in synthesizing graphene by chemical vapor deposition methods (CVD) has opened up enormous opportunities for large-scale device applications. In order to improve the electrical properties of CVD graphene grown on copper (Cu-CVD graphene), recent efforts have focussed on increasing the grain size of such polycrystalline graphene films to 100 micrometers and larger. While an increase in grain size and hence, a decrease of grain boundary density is expected to greatly enhance the device performance, here we show that the charge mobility and sheet resistance of Cu-CVD graphene is already limited within a single grain. We find that the current high-temperature growth and wet transfer methods of CVD graphene result in quasi-periodic nanoripple arrays (NRAs). Electron-flexural phonon scattering in such partially suspended graphene devices introduces anisotropic charge transport and sets limits to both the highest possible charge mobility and lowest possible sheet resistance values. Our findings provide guidance for further improving the CVD graphene growth and transfer process.
△ Less
Submitted 6 February, 2013;
originally announced February 2013.
-
Single dish performance of KVN 21-m radio telescopes:Simultaneous observations at 22 and 43 GHz
Authors:
Sang-Sung Lee,
Do-Young Byun,
Chung Sik Oh,
Seog-Tae Han,
Do-Heung Je,
Kee-Tae Kim,
Seog-Oh Wi,
Se-Hyung Cho,
Bong Won Sohn,
Jaeheon Kim,
Jeewon Lee,
Se-** Oh,
Min-Gyu Song,
Jiman Kang,
Moon-Hee Jung,
Jeong Ae Lee,
Junghwan Oh,
Jae-Han Bae,
So-Young Yun,
Jung-Won Lee,
Bong Gyu Kim,
Hyunsoo Chung,
Duk-Gyoo Roh,
Chang Hoon Lee,
Hyun Goo Kim
, et al. (8 additional authors not shown)
Abstract:
We report simultaneous multi-frequency observing performance at 22 and 43 GHz of the 21-m shaped-Cassegrain radio telescopes of the Korean VLBI Network (KVN). KVN is the first millimeter-dedicated VLBI network in Korea having a maximum baseline length of 480 km. It currently operates at 22 and 43 GHz and planed to operate in four frequency bands, 22, 43, 86, and 129 GHz. The unique quasioptics of…
▽ More
We report simultaneous multi-frequency observing performance at 22 and 43 GHz of the 21-m shaped-Cassegrain radio telescopes of the Korean VLBI Network (KVN). KVN is the first millimeter-dedicated VLBI network in Korea having a maximum baseline length of 480 km. It currently operates at 22 and 43 GHz and planed to operate in four frequency bands, 22, 43, 86, and 129 GHz. The unique quasioptics of KVN enable simultaneous multi-frequency observations based on efficient beam filtering and accuarate antenna-beam alignment at 22 and 43 GHz. We found that the offset of the beams is within <5 arcseconds over all pointing directions of antenna. The dual polarization, cooled HEMT receivers at 22 and 43 GHz result in receiver noise temperatures less than 40 K at 21.25-23.25 GHz and 80 K at 42.11-44.11 GHz. The pointing accuracies have been measured to be 3 arcseconds in azimuth and elevation for all antennas. The measured aperture efficiencies are 65%(K)/67%(Q), 62%(K)/59%(Q), and 66%(K)/60%(Q) for the three KVN antennas, KVNYS, KVNUS, and KVNTN, respectively. The main-beam efficiencies are measured to be 50%(K)/52%(Q), 48%(K)/50%(Q), and 50%(K)/47%(Q) for KVNYS, KVNUS, and KVNTN, respectively. The estimated Moon efficiencies are 77%(K)/90%(Q), 74%(K)/79%(Q), and 80%(K)/86%(Q) for KVNYS, KVNUS, KVNTN, respectively. The elevation dependence of the aperture efficiencies is quite flat for elevations > 20 degrees.
△ Less
Submitted 18 October, 2011;
originally announced October 2011.
-
Wafer-scale graphene/ferroelectric hybrid devices for low-voltage electronics
Authors:
Yi Zheng,
Guang-Xin Ni,
Sukang Bae,
Chun-Xiao Cong,
Orhan Kahya,
Chee-Tat Toh,
Hye Ri Kim,
Danho Im,
Ting Yu,
Jong Hyun Ahn,
Byung Hee Hong,
Barbaros Ozyilmaz
Abstract:
Preparing graphene and its derivatives on functional substrates may open enormous opportunities for exploring the intrinsic electronic properties and new functionalities of graphene. However, efforts in replacing SiO$_{2}$ have been greatly hampered by a very low sample yield of the exfoliation and related transferring methods. Here, we report a new route in exploring new graphene physics and func…
▽ More
Preparing graphene and its derivatives on functional substrates may open enormous opportunities for exploring the intrinsic electronic properties and new functionalities of graphene. However, efforts in replacing SiO$_{2}$ have been greatly hampered by a very low sample yield of the exfoliation and related transferring methods. Here, we report a new route in exploring new graphene physics and functionalities by transferring large-scale chemical vapor deposition single-layer and bilayer graphene to functional substrates. Using ferroelectric Pb(Zr$_{0.3}$Ti$_{0.7}$)O$_{3}$ (PZT), we demonstrate ultra-low voltage operation of graphene field effect transistors within $\pm1$ V with maximum do** exceeding $10^{13}\,\mathrm{cm^{-2}}$ and on-off ratios larger than 10 times. After polarizing PZT, switching of graphene field effect transistors are characterized by pronounced resistance hysteresis, suitable for ultra-fast non-volatile electronics.
△ Less
Submitted 6 January, 2011;
originally announced January 2011.