-
High-Q magnetic levitation and control of superconducting microspheres at millikelvin temperatures
Authors:
Joachim Hofer,
Rudolf Gross,
Gerard Higgins,
Hans Huebl,
Oliver F. Kieler,
Reinhold Kleiner,
Dieter Koelle,
Philip Schmidt,
Joshua A. Slater,
Michael Trupke,
Kevin Uhl,
Thomas Weimann,
Witlef Wieczorek,
Markus Aspelmeyer
Abstract:
We report the levitation of a superconducting lead-tin sphere with 100 micrometer diameter (corresponding to a mass of 5.6 micrograms) in a static magnetic trap formed by two coils in an anti-Helmholtz configuration, with adjustable resonance frequencies up to 240 hertz. The center-of-mass motion of the sphere is monitored magnetically using a dc superconducting quantum interference device as well…
▽ More
We report the levitation of a superconducting lead-tin sphere with 100 micrometer diameter (corresponding to a mass of 5.6 micrograms) in a static magnetic trap formed by two coils in an anti-Helmholtz configuration, with adjustable resonance frequencies up to 240 hertz. The center-of-mass motion of the sphere is monitored magnetically using a dc superconducting quantum interference device as well as optically and exhibits quality factors of up to 2.6e7. We also demonstrate 3D magnetic feedback control of the sphere's motion. The setup is housed in a dilution refrigerator operating at 15 millikelvin. By implementing a cryogenic vibration isolation system we can attenuate environmental vibrations at 200 hertz by approximately seven orders of magnitude. The combination of low temperature, large mass and high quality factor as well as adjustable resonance frequencies provides a promising platform for testing quantum physics in previously unexplored regimes with high mass and long coherence times.
△ Less
Submitted 1 August, 2023; v1 submitted 11 November, 2022;
originally announced November 2022.
-
Magnetization reversal of an individual exchange biased permalloy nanotube
Authors:
A. Buchter,
R. Wölbing,
M. Wyss,
O. F. Kieler,
T. Weimann,
J. Kohlmann,
A. B. Zorin,
D. Rüffer,
F. Matteini,
G. Tütüncüoglu,
F. Heimbach,
A. Kleibert,
A. Fontcuberta i Morral,
D. Grundler,
R. Kleiner,
D. Koelle,
M. Poggio
Abstract:
We investigate the magnetization reversal mechanism in an individual permalloy (Py) nanotube (NT) using a hybrid magnetometer consisting of a nanometer-scale SQUID (nanoSQUID) and a cantilever torque sensor. The Py NT is affixed to the tip of a Si cantilever and positioned in order to optimally couple its stray flux into a Nb nanoSQUID. We are thus able to measure both the NT's volume magnetizatio…
▽ More
We investigate the magnetization reversal mechanism in an individual permalloy (Py) nanotube (NT) using a hybrid magnetometer consisting of a nanometer-scale SQUID (nanoSQUID) and a cantilever torque sensor. The Py NT is affixed to the tip of a Si cantilever and positioned in order to optimally couple its stray flux into a Nb nanoSQUID. We are thus able to measure both the NT's volume magnetization by dynamic cantilever magnetometry and its stray flux using the nanoSQUID. We observe a training effect and temperature dependence in the magnetic hysteresis, suggesting an exchange bias. We find a low blocking temperature $T_B = 18 \pm 2$ K, indicating the presence of a thin antiferromagnetic native oxide, as confirmed by X-ray absorption spectroscopy on similar samples. Furthermore, we measure changes in the shape of the magnetic hysteresis as a function of temperature and increased training. These observations show that the presence of a thin exchange-coupled native oxide modifies the magnetization reversal process at low temperatures. Complementary information obtained via cantilever and nanoSQUID magnetometry allows us to conclude that, in the absence of exchange coupling, this reversal process is nucleated at the NT's ends and propagates along its length as predicted by theory.
△ Less
Submitted 1 December, 2015;
originally announced December 2015.
-
Reversal mechanism of an individual Ni nanotube simultaneously studied by torque and SQUID magnetometry
Authors:
A. Buchter,
J. Nagel,
D. Rüffer,
F. Xue,
D. P. Weber,
O. F. Kieler,
T. Weimann,
J. Kohlmann,
A. B. Zorin,
E. Russo-Averchi,
R. Huber,
P. Berberich,
A. Fontcuberta i Morral,
M. Kemmler,
R. Kleiner,
D. Koelle,
D. Grundler,
M. Poggio
Abstract:
Using an optimally coupled nanometer-scale superconducting quantum interference device, we measure the magnetic flux originating from an individual ferromagnetic Ni nanotube attached to a Si cantilever. At the same time, we detect the nanotube's volume magnetization using torque magnetometry. We observe both the predicted reversible and irreversible reversal processes. A detailed comparison with m…
▽ More
Using an optimally coupled nanometer-scale superconducting quantum interference device, we measure the magnetic flux originating from an individual ferromagnetic Ni nanotube attached to a Si cantilever. At the same time, we detect the nanotube's volume magnetization using torque magnetometry. We observe both the predicted reversible and irreversible reversal processes. A detailed comparison with micromagnetic simulations suggests that vortex-like states are formed in different segments of the individual nanotube. Such stray-field free states are interesting for memory applications and non-invasive sensing.
△ Less
Submitted 18 July, 2013; v1 submitted 28 May, 2013;
originally announced May 2013.
-
Nanoscale multifunctional sensor formed by a Ni nanotube and a scanning Nb nanoSQUID
Authors:
J. Nagel,
A. Buchter,
F. Xue,
O. F. Kieler,
T. Weimann,
J. Kohlmann,
A. B. Zorin,
D. Rüffer,
E. Russo-Averchi,
R. Huber,
P. Berberich,
A. Fontcuberta i Morral,
D. Grundler,
R. Kleiner,
D. Koelle,
M. Poggio,
M. Kemmler
Abstract:
Nanoscale magnets might form the building blocks of next generation memories. To explore their functionality, magnetic sensing at the nanoscale is key. We present a multifunctional combination of a scanning nanometer-sized superconducting quantum interference device (nanoSQUID) and a Ni nanotube attached to an ultrasoft cantilever as a magnetic tip. We map out and analyze the magnetic coupling bet…
▽ More
Nanoscale magnets might form the building blocks of next generation memories. To explore their functionality, magnetic sensing at the nanoscale is key. We present a multifunctional combination of a scanning nanometer-sized superconducting quantum interference device (nanoSQUID) and a Ni nanotube attached to an ultrasoft cantilever as a magnetic tip. We map out and analyze the magnetic coupling between the Ni tube and the Nb nanoSQUID, demonstrate imaging of an Abrikosov vortex trapped in the SQUID structure - which is important in ruling out spurious magnetic signals - and reveal the high potential of the nanoSQUID as an ultrasensitive displacement detector. Our results open a new avenue for fundamental studies of nanoscale magnetism and superconductivity.
△ Less
Submitted 6 May, 2013;
originally announced May 2013.
-
Superconducting quantum interference devices with submicron Nb/HfTi/Nb junctions for investigation of small magnetic particles
Authors:
J. Nagel,
O. F. Kieler,
T. Weimann,
R. Wölbing,
J. Kohlmann,
A. B. Zorin,
R. Kleiner,
D. Koelle,
M. Kemmler
Abstract:
We investigated, at temperature $4.2\,\mathrm{K}$, electric transport, flux noise and resulting spin sensitivity of miniaturized Nb direct current superconducting quantum interference devices (SQUIDs) based on submicron Josephson junctions with HfTi barriers. The SQUIDs are either of the magnetometer-type or gradiometric in layout. In the white noise regime, for the best magnetometer we obtain a f…
▽ More
We investigated, at temperature $4.2\,\mathrm{K}$, electric transport, flux noise and resulting spin sensitivity of miniaturized Nb direct current superconducting quantum interference devices (SQUIDs) based on submicron Josephson junctions with HfTi barriers. The SQUIDs are either of the magnetometer-type or gradiometric in layout. In the white noise regime, for the best magnetometer we obtain a flux noise $S_Φ^{1/2}=250\,\mathrm{n}Φ_0/\mathrm{Hz}^{1/2}$, corresponding to a spin sensitivity $S^{1/2}_μ\,\ge\,29\,μ_B/\mathrm{Hz}^{1/2}$. For the gradiometer we find $S_Φ^{1/2}=300\,\mathrm{n}Φ_0/\mathrm{Hz}^{1/2}$ and $S^{1/2}_μ\,\ge\,44\,μ_B/\mathrm{Hz}^{1/2}$. The devices can still be optimized with respect to flux noise and coupling between a magnetic particle and the SQUID, leaving room for further improvement towards single spin resolution.
△ Less
Submitted 10 June, 2011;
originally announced June 2011.