-
Detailed Report on the Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm
Authors:
D. P. Aguillard,
T. Albahri,
D. Allspach,
A. Anisenkov,
K. Badgley,
S. Baeßler,
I. Bailey,
L. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
E. Barzi,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
S. Braun,
M. Bressler,
G. Cantatore,
R. M. Carey,
B. C. K. Casey
, et al. (168 additional authors not shown)
Abstract:
We present details on a new measurement of the muon magnetic anomaly, $a_μ= (g_μ-2)/2$. The result is based on positive muon data taken at Fermilab's Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses $3.1$ GeV$/c$ polarized muons stored in a $7.1$-m-radius storage ring with a $1.45$ T uniform magnetic field. The value of $ a_μ$ is determined from the measured difference b…
▽ More
We present details on a new measurement of the muon magnetic anomaly, $a_μ= (g_μ-2)/2$. The result is based on positive muon data taken at Fermilab's Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses $3.1$ GeV$/c$ polarized muons stored in a $7.1$-m-radius storage ring with a $1.45$ T uniform magnetic field. The value of $ a_μ$ is determined from the measured difference between the muon spin precession frequency and its cyclotron frequency. This difference is normalized to the strength of the magnetic field, measured using Nuclear Magnetic Resonance (NMR). The ratio is then corrected for small contributions from beam motion, beam dispersion, and transient magnetic fields. We measure $a_μ= 116 592 057 (25) \times 10^{-11}$ (0.21 ppm). This is the world's most precise measurement of this quantity and represents a factor of $2.2$ improvement over our previous result based on the 2018 dataset. In combination, the two datasets yield $a_μ(\text{FNAL}) = 116 592 055 (24) \times 10^{-11}$ (0.20 ppm). Combining this with the measurements from Brookhaven National Laboratory for both positive and negative muons, the new world average is $a_μ$(exp) $ = 116 592 059 (22) \times 10^{-11}$ (0.19 ppm).
△ Less
Submitted 22 May, 2024; v1 submitted 23 February, 2024;
originally announced February 2024.
-
Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm
Authors:
D. P. Aguillard,
T. Albahri,
D. Allspach,
A. Anisenkov,
K. Badgley,
S. Baeßler,
I. Bailey,
L. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
E. Barzi,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
S. Braun,
M. Bressler,
G. Cantatore,
R. M. Carey,
B. C. K. Casey
, et al. (166 additional authors not shown)
Abstract:
We present a new measurement of the positive muon magnetic anomaly, $a_μ\equiv (g_μ- 2)/2$, from the Fermilab Muon $g\!-\!2$ Experiment using data collected in 2019 and 2020. We have analyzed more than 4 times the number of positrons from muon decay than in our previous result from 2018 data. The systematic error is reduced by more than a factor of 2 due to better running conditions, a more stable…
▽ More
We present a new measurement of the positive muon magnetic anomaly, $a_μ\equiv (g_μ- 2)/2$, from the Fermilab Muon $g\!-\!2$ Experiment using data collected in 2019 and 2020. We have analyzed more than 4 times the number of positrons from muon decay than in our previous result from 2018 data. The systematic error is reduced by more than a factor of 2 due to better running conditions, a more stable beam, and improved knowledge of the magnetic field weighted by the muon distribution, $\tildeω'^{}_p$, and of the anomalous precession frequency corrected for beam dynamics effects, $ω_a$. From the ratio $ω_a / \tildeω'^{}_p$, together with precisely determined external parameters, we determine $a_μ= 116\,592\,057(25) \times 10^{-11}$ (0.21 ppm). Combining this result with our previous result from the 2018 data, we obtain $a_μ\text{(FNAL)} = 116\,592\,055(24) \times 10^{-11}$ (0.20 ppm). The new experimental world average is $a_μ(\text{Exp}) = 116\,592\,059(22)\times 10^{-11}$ (0.19 ppm), which represents a factor of 2 improvement in precision.
△ Less
Submitted 4 October, 2023; v1 submitted 11 August, 2023;
originally announced August 2023.
-
Measurement of the Positive Muon Anomalous Magnetic Moment to 0.46 ppm
Authors:
B. Abi,
T. Albahri,
S. Al-Kilani,
D. Allspach,
L. P. Alonzi,
A. Anastasi,
A. Anisenkov,
F. Azfar,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
E. Barzi,
A. Basti,
F. Bedeschi,
A. Behnke,
M. Berz,
M. Bhattacharya,
H. P. Binney,
R. Bjorkquist,
P. Bloom,
J. Bono,
E. Bottalico
, et al. (212 additional authors not shown)
Abstract:
We present the first results of the Fermilab Muon g-2 Experiment for the positive muon magnetic anomaly $a_μ\equiv (g_μ-2)/2$. The anomaly is determined from the precision measurements of two angular frequencies. Intensity variation of high-energy positrons from muon decays directly encodes the difference frequency $ω_a$ between the spin-precession and cyclotron frequencies for polarized muons in…
▽ More
We present the first results of the Fermilab Muon g-2 Experiment for the positive muon magnetic anomaly $a_μ\equiv (g_μ-2)/2$. The anomaly is determined from the precision measurements of two angular frequencies. Intensity variation of high-energy positrons from muon decays directly encodes the difference frequency $ω_a$ between the spin-precession and cyclotron frequencies for polarized muons in a magnetic storage ring. The storage ring magnetic field is measured using nuclear magnetic resonance probes calibrated in terms of the equivalent proton spin precession frequency ${\tildeω'^{}_p}$ in a spherical water sample at 34.7$^{\circ}$C. The ratio $ω_a / {\tildeω'^{}_p}$, together with known fundamental constants, determines $a_μ({\rm FNAL}) = 116\,592\,040(54)\times 10^{-11}$ (0.46\,ppm). The result is 3.3 standard deviations greater than the standard model prediction and is in excellent agreement with the previous Brookhaven National Laboratory (BNL) E821 measurement. After combination with previous measurements of both $μ^+$ and $μ^-$, the new experimental average of $a_μ({\rm Exp}) = 116\,592\,061(41)\times 10^{-11}$ (0.35\,ppm) increases the tension between experiment and theory to 4.2 standard deviations
△ Less
Submitted 7 April, 2021;
originally announced April 2021.
-
Measurement of the anomalous precession frequency of the muon in the Fermilab Muon g-2 experiment
Authors:
T. Albahri,
A. Anastasi,
A. Anisenkov,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
A. Basti,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
G. Cantatore,
R. M. Carey,
B. C. K. Casey,
D. Cauz,
R. Chakraborty,
S. P. Chang,
A. Chapelain
, et al. (153 additional authors not shown)
Abstract:
The Muon g-2 Experiment at Fermi National Accelerator Laboratory (FNAL) has measured the muon anomalous precession frequency $ω_a$ to an uncertainty of 434 parts per billion (ppb), statistical, and 56 ppb, systematic, with data collected in four storage ring configurations during its first physics run in 2018. When combined with a precision measurement of the magnetic field of the experiment's muo…
▽ More
The Muon g-2 Experiment at Fermi National Accelerator Laboratory (FNAL) has measured the muon anomalous precession frequency $ω_a$ to an uncertainty of 434 parts per billion (ppb), statistical, and 56 ppb, systematic, with data collected in four storage ring configurations during its first physics run in 2018. When combined with a precision measurement of the magnetic field of the experiment's muon storage ring, the precession frequency measurement determines a muon magnetic anomaly of $a_μ({\rm FNAL}) = 116\,592\,040(54) \times 10^{-11}$ (0.46 ppm). This article describes the multiple techniques employed in the reconstruction, analysis and fitting of the data to measure the precession frequency. It also presents the averaging of the results from the eleven separate determinations of ω_a, and the systematic uncertainties on the result.
△ Less
Submitted 7 April, 2021;
originally announced April 2021.
-
Beam dynamics corrections to the Run-1 measurement of the muon anomalous magnetic moment at Fermilab
Authors:
T. Albahri,
A. Anastasi,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
G. Cantatore,
R. M. Carey,
B. C. K. Casey,
D. Cauz,
R. Chakraborty,
S. P. Chang,
A. Chapelain,
S. Charity,
R. Chislett
, et al. (152 additional authors not shown)
Abstract:
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is fe…
▽ More
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is felt by relativistic muons passing transversely through the radial electric field components created by the ESQ system. The correction depends on the stored momentum distribution and the tunes of the ring, which has relatively weak vertical focusing. Vertical betatron motions imply that the muons do not orbit the ring in a plane exactly orthogonal to the vertical magnetic field direction. A correction is necessary to account for an average pitch angle associated with their trajectories. A third small correction is necessary because muons that escape the ring during the storage time are slightly biased in initial spin phase compared to the parent distribution. Finally, because two high-voltage resistors in the ESQ network had longer than designed RC time constants, the vertical and horizontal centroids and envelopes of the stored muon beam drifted slightly, but coherently, during each storage ring fill. This led to the discovery of an important phase-acceptance relationship that requires a correction. The sum of the corrections to $ω_a^m$ is 0.50 $\pm$ 0.09 ppm; the uncertainty is small compared to the 0.43 ppm statistical precision of $ω_a^m$.
△ Less
Submitted 23 April, 2021; v1 submitted 7 April, 2021;
originally announced April 2021.
-
Magnetic Field Measurement and Analysis for the Muon g-2 Experiment at Fermilab
Authors:
T. Albahri,
A. Anastasi,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
G. Cantatore,
R. M. Carey,
B. C. K. Casey,
D. Cauz,
R. Chakraborty,
S. P. Chang,
A. Chapelain,
S. Charity,
R. Chislett
, et al. (148 additional authors not shown)
Abstract:
The Fermi National Accelerator Laboratory has measured the anomalous precession frequency $a^{}_μ= (g^{}_μ-2)/2$ of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018. This paper documents the measurement of the magnetic field in the muon storage ring. The magnetic field is monitored by nuclear magnetic resonance systems and calibrat…
▽ More
The Fermi National Accelerator Laboratory has measured the anomalous precession frequency $a^{}_μ= (g^{}_μ-2)/2$ of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018. This paper documents the measurement of the magnetic field in the muon storage ring. The magnetic field is monitored by nuclear magnetic resonance systems and calibrated in terms of the equivalent proton spin precession frequency in a spherical water sample at 34.7$^\circ$C. The measured field is weighted by the muon distribution resulting in $\tildeω'^{}_p$, the denominator in the ratio $ω^{}_a$/$\tildeω'^{}_p$ that together with known fundamental constants yields $a^{}_μ$. The reported uncertainty on $\tildeω'^{}_p$ for the Run-1 data set is 114 ppb consisting of uncertainty contributions from frequency extraction, calibration, map**, tracking, and averaging of 56 ppb, and contributions from fast transient fields of 99 ppb.
△ Less
Submitted 17 June, 2022; v1 submitted 7 April, 2021;
originally announced April 2021.
-
Beam particle tracking with a low-mass mini time projection chamber in the PEN experiment
Authors:
C. J. Glaser,
D. Pocanic,
A. van der Schaaf,
V. A. Baranov,
N. V. Khomutov,
N. P. Kravchuk,
N. A. Kuchinsky
Abstract:
The international PEN collaboration aims to obtain the branching ratio for the pion electronic decay $π^+ \to e^+ν_e(γ)$, aka $π_{e2}$, to a relative precision of $5\times 10^{-4}$ or better. The PEN apparatus comprises a number of detection systems, all contributing vital information to the PEN event reconstruction. This paper discusses the design, performance, and Monte Carlo simulation of the m…
▽ More
The international PEN collaboration aims to obtain the branching ratio for the pion electronic decay $π^+ \to e^+ν_e(γ)$, aka $π_{e2}$, to a relative precision of $5\times 10^{-4}$ or better. The PEN apparatus comprises a number of detection systems, all contributing vital information to the PEN event reconstruction. This paper discusses the design, performance, and Monte Carlo simulation of the mini time projection chamber (mTPC) used for pion, muon, and positron beam particle tracking. We also review the use of the extracted trajectory coordinates in the analysis, in particular in constructing observables critical for discriminating background processes, and in maximizing the fiducial volume of the target in which decay event vertices can be accepted for branching ratio extraction without introducing bias.
△ Less
Submitted 20 May, 2021; v1 submitted 22 December, 2020;
originally announced December 2020.
-
PEN experiment: a precise test of lepton universality
Authors:
C. J. Glaser,
D. Pocanic,
L. P. Alonzi,
V. A. Baranov,
W. Bertl,
M. Bychkov,
Yu. M. Bystritsky,
E. Frlez,
V. A. Kalinnikov,
N. V. Khomutov,
A. S. Korenchenko,
S. M. Korenchenko,
M. Korolija,
T. Kozlowski,
N. P. Kravchuk,
N. A. Kuchinsky,
M. C. Lehman,
E. Munyangabe,
D. Mzhavia,
A. Palladino,
P. Robmann,
A. M. Rozhdestvensky,
R. T. Smith,
I. Supek,
P. Truöl
, et al. (4 additional authors not shown)
Abstract:
With few open channels and uncomplicated theoretical description, charged pion decays are uniquely sensitive to certain standard model (SM) symmetries, the universality of weak fermion couplings, and to aspects of pion structure and chiral dynamics. We review the current knowledge of the pion electronic decay $π^+ \to e^+ ν_e(γ)$, or $π_{e2(γ)}$, and the resulting limits on non-SM processes. Focus…
▽ More
With few open channels and uncomplicated theoretical description, charged pion decays are uniquely sensitive to certain standard model (SM) symmetries, the universality of weak fermion couplings, and to aspects of pion structure and chiral dynamics. We review the current knowledge of the pion electronic decay $π^+ \to e^+ ν_e(γ)$, or $π_{e2(γ)}$, and the resulting limits on non-SM processes. Focusing on the PEN experiment at the Paul Scherrer Institute (PSI), Switzerland, we examine the prospects for further improvement in the near term.
△ Less
Submitted 29 November, 2018;
originally announced December 2018.
-
PEN: a low energy test of lepton universality
Authors:
D. Pocanic,
L. P. Alonzi,
V. A. Baranov,
W. Bertl,
M. Bychkov,
Yu. M. Bystritsky,
E. Frlez,
C. J. Glaser,
V. A. Kalinnikov,
N. V. Khomutov,
A. S. Korenchenko,
S. M. Korenchenko,
M. Korolija,
T. Kozlowski,
N. P. Kravchuk,
N. A. Kuchinsky,
M. C. Lehman,
D. Mzhavia,
A. Palladino,
P. Robmann,
A. M. Rozhdestvensky,
I. Supek,
P. Truoel,
A. van der Schaaf,
E. P. Velicheva
, et al. (2 additional authors not shown)
Abstract:
Allowed charged $π$ meson decays are characterized by simple dynamics, few available decay channels, mainly into leptons, and extremely well controlled radiative and loop corrections. In that sense, pion decays represent a veritable triumph of the standard model (SM) of elementary particles and interactions. This relative theoretical simplicity makes charged pion decays a sensitive means for testi…
▽ More
Allowed charged $π$ meson decays are characterized by simple dynamics, few available decay channels, mainly into leptons, and extremely well controlled radiative and loop corrections. In that sense, pion decays represent a veritable triumph of the standard model (SM) of elementary particles and interactions. This relative theoretical simplicity makes charged pion decays a sensitive means for testing the underlying symmetries and the universality of weak fermion couplings, as well as for studying pion structure and chiral dynamics. Even after considerable recent improvements, experimental precision is lagging far behind that of the theoretical description for pion decays. We review the current state of experimental study of the pion electronic decay $π^+ \to e^+ν_e(γ)$, or $π_{e2(γ)}$, where the $(γ)$ indicates inclusion and explicit treatment of radiative decay events. We briefly review the limits on non-SM processes arising from the present level of experimental precision in $π_{e2(γ)}$ decays. Focusing on the PEN experiment at the Paul Scherrer Institute (PSI), Switzerland, we examine the prospects for further improvement in the near term.
△ Less
Submitted 18 January, 2017;
originally announced January 2017.
-
2-D straw detectors with high rate capability
Authors:
N. A. Kuchinskiy,
V. A. Baranov,
V. N. Duginov,
F. E. Zyazyulya,
A. S. Korenchenko,
A. O. Kolesnikov,
N. P. Kravchuk,
S. A. Movchan,
A. I. Rudenko,
V. S. Smirnov,
N. V. Khomutov,
V. A. Chekhovsky,
A. S. Lobko,
O. V. Misevich
Abstract:
Precise measurement of straw axial coordinate (along the anode wire) with accuracy compatible with straw radial coordinate determination by drift time measurement and increase of straw detector rate capability by using straw cathode readout instead of anode readout are presented.
Precise measurement of straw axial coordinate (along the anode wire) with accuracy compatible with straw radial coordinate determination by drift time measurement and increase of straw detector rate capability by using straw cathode readout instead of anode readout are presented.
△ Less
Submitted 18 February, 2015;
originally announced February 2015.
-
Muon (g-2) Technical Design Report
Authors:
J. Grange,
V. Guarino,
P. Winter,
K. Wood,
H. Zhao,
R. M. Carey,
D. Gastler,
E. Hazen,
N. Kinnaird,
J. P. Miller,
J. Mott,
B. L. Roberts,
J. Benante,
J. Crnkovic,
W. M. Morse,
H. Sayed,
V. Tishchenko,
V. P. Druzhinin,
B. I. Khazin,
I. A. Koop,
I. Logashenko,
Y. M. Shatunov,
E. Solodov,
M. Korostelev,
D. Newton
, et al. (176 additional authors not shown)
Abstract:
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should…
▽ More
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should be able to determine definitively whether or not the E821 result is evidence for physics beyond the Standard Model. After a review of the physics motivation and the basic technique, which will use the muon storage ring built at BNL and now relocated to Fermilab, the design of the new experiment is presented. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-2/3 approval.
△ Less
Submitted 11 May, 2018; v1 submitted 27 January, 2015;
originally announced January 2015.
-
New results in rare allowed muon and pion decays
Authors:
D. Pocanic,
E. Munyangabe,
M. Bychkov,
V. A. Baranov,
W. Bertl,
Yu. M. Bystritsky,
E. Frlez,
V. A. Kalinnikov,
N. V. Khomutov,
A. S. Korenchenko,
S. M. Korenchenko,
M. Korolija,
T. Kozlowski,
N. P. Kravchuk,
N. A. Kuchinsky,
M. C. Lehman,
D. Mekterovic,
D. Mzhavia,
A. Palladino,
P. Robmann,
A. M. Rozhdestvensky,
I. Supek,
P. Truoel,
Z. Tsamalaidze,
A. van der Schaaf
, et al. (3 additional authors not shown)
Abstract:
Simple dynamics, few available decay channels, and highly controlled radiative and loop corrections, make pion and muon decays a sensitive means of exploring details of the underlying symmetries. We review the current status of the rare decays: pi+ -> e+ nu, pi+ -> e+ nu gamma, pi+ -> pi0 e+ nu, and mu+ -> e+ nu nu-bar gamma. For the latter we report new preliminary values for the branching ratio…
▽ More
Simple dynamics, few available decay channels, and highly controlled radiative and loop corrections, make pion and muon decays a sensitive means of exploring details of the underlying symmetries. We review the current status of the rare decays: pi+ -> e+ nu, pi+ -> e+ nu gamma, pi+ -> pi0 e+ nu, and mu+ -> e+ nu nu-bar gamma. For the latter we report new preliminary values for the branching ratio B(E_gamma >10 MeV, theta_(e-gamma) > 30deg) = 4.365 (9)_stat (42)_syst x 10^{-3}, and the decay parameter eta-bar = 0.006 (17)_stat (18)_syst, both in excellent agreement with standard model predictions. We review recent measurements, particularly by the PIBETA and PEN experiments, and near-term prospects for improvement. These and other similar precise low energy studies complement modern collider results materially.
△ Less
Submitted 28 March, 2014;
originally announced March 2014.
-
The use of segmented cathode of a drift tube for designing a track detector with a high rate capability
Authors:
N. A. Kuchinskiy,
V. A. Baranov,
V. N. Duginov,
F. E. Zyazyulya,
A. S. Korenchenko,
A. O. Kolesnikov,
N. P. Kravchuk,
S. A. Movchan,
A. I. Rudenko,
V. S. Smirnov,
N. V. Khomutov,
V. A. Chekhovsky
Abstract:
Detector rate capability is one of the main parameters for designing a new detector for high energy physics due to permanent rise of the beam luminosity of modern accelerators. One of the widely used detectors for particle track reconstruction is a straw detector based on drift tubes. The rate capability of such detectors is limited by the parameters of readout electronics. The traditional method…
▽ More
Detector rate capability is one of the main parameters for designing a new detector for high energy physics due to permanent rise of the beam luminosity of modern accelerators. One of the widely used detectors for particle track reconstruction is a straw detector based on drift tubes. The rate capability of such detectors is limited by the parameters of readout electronics. The traditional method of increasing detector rate capability is increasing their granularity (a number of readout channels) by reducing the straw diameter and/or by dividing the straw anode wire into two parts (for decreasing the rate per readout channel). A new method of designing straw detectors with a high rate capability is presented and tested. The method is based on dividing the straw cathode into parts and independent readout of each part.
△ Less
Submitted 18 October, 2013;
originally announced October 2013.
-
New studies of allowed pion and muon decays
Authors:
D. Pocanic,
A. Palladino,
L. P. Alonzi,
V. A. Baranov,
W. Bertl,
M. Bychkov,
Yu. M. Bystritsky,
E. Frlez,
V. A. Kalinnikov,
N. V. Khomutov,
A. S. Korenchenko,
S. M. Korenchenko,
M. Korolija,
T. Kozlowski,
N. P. Kravchuk,
N. A. Kuchinsky,
M. C. Lehman,
D. Mekterovic,
E. Munyangabe,
D. Mzhavia,
P. Robmann,
A. M. Rozhdestvensky,
S. N. Shkarovskiy,
U. Straumann,
I. Supek
, et al. (5 additional authors not shown)
Abstract:
Building on the rare pion and muon decay results of the PIBETA experiment, the PEN collaboration has undertaken a precise measurement of B_{πe2} = R^π_{e/μ}, the π^+ -> e^+ν(γ) decay branching ratio, at the Paul Scherrer Institute, to reduce the present 40\times experimental precision lag behind theory to ~ 6-7\times. Because of large helicity suppression, R^π_{e/μ} is uniquely sensitive to contri…
▽ More
Building on the rare pion and muon decay results of the PIBETA experiment, the PEN collaboration has undertaken a precise measurement of B_{πe2} = R^π_{e/μ}, the π^+ -> e^+ν(γ) decay branching ratio, at the Paul Scherrer Institute, to reduce the present 40\times experimental precision lag behind theory to ~ 6-7\times. Because of large helicity suppression, R^π_{e/μ} is uniquely sensitive to contributions from non-(V-A) physics, making this decay a particularly suitable subject of study. Even at current precision, the experimental value of B_{πe2} provides the most accurate test of lepton universality available. During runs in 2008-10, PEN has accumulated over 2\times 10^7 π_{e2} events; a comprehensive maximum-likelihood analysis is currently under way. The new data will also lead to improved precision of the earlier PIBETA results on radiative πand μdecays.
△ Less
Submitted 18 October, 2012;
originally announced October 2012.
-
Detector with a profile-based cathode and a two-coordinate pad-strip readout system
Authors:
N. A. Kuchinskiy,
V. A. Baturitskii,
N. P. Kravchuk,
A. S. Korenchenko,
N. V. Khomutov,
V. S. Smirnov,
V. A. Chekhovskii,
S. A. Movchan,
F. E. Zyazyulya
Abstract:
A detector with a profile-based cathode and a pad-strip cathode readout system is experimentally investigated. Cathode pads arranged along each anode wire are diagonally interconnected and form strips that cross the detector at an angle with respect to the anode wire. Two coordinates from the cathodes and one from the anode wire allow identification of tracks in high multiplicity events with a sin…
▽ More
A detector with a profile-based cathode and a pad-strip cathode readout system is experimentally investigated. Cathode pads arranged along each anode wire are diagonally interconnected and form strips that cross the detector at an angle with respect to the anode wire. Two coordinates from the cathodes and one from the anode wire allow identification of tracks in high multiplicity events with a single detector plane.
△ Less
Submitted 19 December, 2011;
originally announced December 2011.
-
Using the cathode surface of straw tube for measuring the track coordinates along the wire
Authors:
V. A. Baranov,
B. A. Chekhovskiy,
N. P. Kravchuk,
A. S. Korenchenko,
N. A. Kuchinskiy,
N. V. Khomutov,
S. A. Movchan,
V. S. Smirnov,
F. E. Zyazyulya
Abstract:
The coordinate detectors based on straw tubes provide a high accuracy of the radial coordinate measurement using the drift time and a small amount of matter in the way of the measured particles. However, the measurement of the coordinate along the wire constitutes a problem. This paper proposes a method for measuring the hit coordinate along the wire with an accuracy better than 1 mm in a straw tu…
▽ More
The coordinate detectors based on straw tubes provide a high accuracy of the radial coordinate measurement using the drift time and a small amount of matter in the way of the measured particles. However, the measurement of the coordinate along the wire constitutes a problem. This paper proposes a method for measuring the hit coordinate along the wire with an accuracy better than 1 mm in a straw tube detector using the signals from the cathodes of the detector.
△ Less
Submitted 27 January, 2012; v1 submitted 11 May, 2011;
originally announced May 2011.
-
PEN: a sensitive search for non-(V-A) weak processes
Authors:
PEN Collaboration,
D. Pocanic,
L. P. Alonzi,
V. A. Baranov,
W. Bertl,
M. Bychkov,
Yu. M. Bystritsky,
E. Frlez,
V. A. Kalinnikov,
N. V. Khomutov,
A. S. Korenchenko,
S. M. Korenchenko,
M. Korolija,
T. Kozlowski,
N. P. Kravchuk,
N. A. Kuchinsky,
D. Mekterovic,
D. Mzhavia,
A. Palladino,
P. Robmann,
A. M. Rozhdestvensky,
S. N. Shkarovskiy,
U. Straumann,
I. Supek,
P. Truoel
, et al. (4 additional authors not shown)
Abstract:
A new measurement of $B_{πe2}$, the $π^+ \to e^+ν(γ)$ decay branching ratio, is currently under way at the Paul Scherrer Institute. The present experimental result on $B_{πe2}$ constitutes the most accurate test of lepton universality available. The accuracy, however, still lags behind the theoretical precision by over an order of magnitude. Thanks to the large helicity suppression of $π_{e2}$ d…
▽ More
A new measurement of $B_{πe2}$, the $π^+ \to e^+ν(γ)$ decay branching ratio, is currently under way at the Paul Scherrer Institute. The present experimental result on $B_{πe2}$ constitutes the most accurate test of lepton universality available. The accuracy, however, still lags behind the theoretical precision by over an order of magnitude. Thanks to the large helicity suppression of $π_{e2}$ decay, the branching ratio is susceptible to significant contributions from new physics, making this decay a particularly suitable subject of study.
△ Less
Submitted 24 September, 2009;
originally announced September 2009.
-
PEN experiment: a precise measurement of the pi+ -> e+ nu decay branching fraction
Authors:
PEN Collaboration,
D. Pocanic,
L. P. Alonzi,
V. A. Baranov,
W. Bertl,
M. Bychkov,
Yu. M. Bystritsky,
E. Frlez,
V. A. Kalinnikov,
N. V. Khomutov,
A. S. Korenchenko,
S. M. Korenchenko,
M. Korolija,
T. Kozlowski,
N. P. Kravchuk,
N. A. Kuchinsky,
D. Mekterovic,
D. Mzhavia,
A. Palladino,
P. Robmann,
A. M. Rozhdestvensky,
S. N. Shkarovskiy,
U. Straumann,
I. Supek,
P. Truoel
, et al. (4 additional authors not shown)
Abstract:
A new measurement of $B_{πe2}$, the $π^+ \to e^+ν(γ)$ decay branching ratio, is currently under way at the Paul Scherrer Institute. The present experimental result on $B_{πe2}$ constitutes the most accurate test of lepton universality available. The accuracy, however, still lags behind the theoretical precision by over an order of magnitude. Because of the large helicity suppression of the…
▽ More
A new measurement of $B_{πe2}$, the $π^+ \to e^+ν(γ)$ decay branching ratio, is currently under way at the Paul Scherrer Institute. The present experimental result on $B_{πe2}$ constitutes the most accurate test of lepton universality available. The accuracy, however, still lags behind the theoretical precision by over an order of magnitude. Because of the large helicity suppression of the $π_{e2}$ decay, its branching ratio is susceptible to significant contributions from new physics, making this decay a particularly suitable subject of study.
△ Less
Submitted 24 September, 2009;
originally announced September 2009.
-
Precise Measurement of pi+ -> e+ nu Branching Ratio
Authors:
E. Frlež,
L. P. Alonzi,
V. A. Baranov,
W. Bertl,
M. Bychkov,
Yu. M. Bystritsky,
N. V. Khomutov,
A. S. Korenchenko,
S. M. Korenchenko,
M. Korolija,
T. Kozlowski,
N. P. Kravchuk,
N. A. Kuchinsky,
D. Mekterović,
D. Mzhavia,
A. Palladino,
D. Počanić,
P. Robmann,
A. M. Rozhdestvensky,
V. V. Sidorkin,
U. Straumann,
I. Supek,
P. Truöl,
A. van der Schaaf,
E. P. Velicheva
, et al. (1 additional authors not shown)
Abstract:
The PEN Collaboration is conducting a new measurement of the pi+ -> e+ nu branching ratio at the Paul Scherrer Institute, with the goal uncertainty of delta B/B(pie2)=5E-4 or lower. At present, the combined accuracy of all published pie2 decay measurements lags behind the theoretical calculation by a factor of 40. In this contribution we report on the PEN detector configuration and its performan…
▽ More
The PEN Collaboration is conducting a new measurement of the pi+ -> e+ nu branching ratio at the Paul Scherrer Institute, with the goal uncertainty of delta B/B(pie2)=5E-4 or lower. At present, the combined accuracy of all published pie2 decay measurements lags behind the theoretical calculation by a factor of 40. In this contribution we report on the PEN detector configuration and its performance during two development runs done in 2007 and 2008.
△ Less
Submitted 15 December, 2008;
originally announced December 2008.
-
New Precise Measurement of the Pion Weak Form Factors in the Pi+ -> e+ nu gamma Decay
Authors:
M. Bychkov,
D. Počanić,
B. A. VanDevender,
V. A. Baranov,
W. Bertl,
Yu. M. Bystritsky,
E. Frlež,
V. A. Kalinnikov,
N. V. Khomutov,
A. S. Korenchenko,
S. M. Korenchenko,
M. Korolija,
T. Kozlowski,
N. P. Kravchuk,
N. A. Kuchinsky,
W. Li,
D. Mekterović,
D. Mzhavia,
S. Ritt,
P. Robmann,
O. A. Rondon-Aramayo,
A. M. Rozhdestvensky,
T. Sakhelashvili,
S. Scheu,
U. Straumann
, et al. (7 additional authors not shown)
Abstract:
We have measured the $π^+\to {\rm e}^+νγ$ branching ratio over a wide region of phase space, based on a total of 65,460 events acquired using the PIBETA detector. Minimum-$χ^2$ fits to the measured $(E_{e^+},E_γ)$ energy distributions result in the weak form factor value of $F_A=0.0119(1)$ with a fixed value of $F_V=0.0259$. An unconstrained fit yields $F_V=0.0258(17)$ and $F_A=0.0117(17)$. In a…
▽ More
We have measured the $π^+\to {\rm e}^+νγ$ branching ratio over a wide region of phase space, based on a total of 65,460 events acquired using the PIBETA detector. Minimum-$χ^2$ fits to the measured $(E_{e^+},E_γ)$ energy distributions result in the weak form factor value of $F_A=0.0119(1)$ with a fixed value of $F_V=0.0259$. An unconstrained fit yields $F_V=0.0258(17)$ and $F_A=0.0117(17)$. In addition, we have measured $a=0.10(6)$ for the dependence of $F_V$ on $q^2$, the ${\rm e}^{+}ν$ pair invariant mass squared, parametrized as $F_V(q^2)=F_V(0)(1+a\cdot q^2)$. The branching ratio for the kinematic region $E_γ> 10 $MeV and $θ_{{\rm e^+}γ} > 40^\circ $ is measured to be $B^{\rm exp}=73.86(54) \times 10^{-8}$. Earlier deviations we reported in the high-$E_γ$/low-$E_{{\rm e}^+}$ kinematic region are resolved, and we find full compatibility with CVC and standard $V$$-$$A$ calculations without a tensor term. We also derive new values for the pion polarizability, $α_E = \rm 2.78(10) \times 10^{-4} fm^3$, and neutral pion lifetime, $τ_{π0} = (8.5 \pm 1.1) \times 10^{-17} $s.
△ Less
Submitted 1 July, 2009; v1 submitted 11 April, 2008;
originally announced April 2008.
-
Precise Measurement of the Pi+ -> Pi0 e+ nu Branching Ratio
Authors:
D. Pocanic,
E. Frlez,
V. A. Baranov,
W. Bertl,
C. Broennimann,
M. Bychkov,
J. F. Crawford,
M. Daum,
N. V. Khomutov,
A. S. Korenchenko,
S. M. Korenchenko,
T. Kozlowski,
N. P. Kravchuk,
N. A. Kuchinsky,
W. Li,
R. C. Minehart,
D. Mzhavia,
B. G. Ritchie,
S. Ritt,
A. M. Rozhdestvensky,
V. V. Sidorkin,
L. C. Smith,
I. Supek,
Z. Tsamalaidze,
B. A. VanDevender
, et al. (3 additional authors not shown)
Abstract:
Using a large acceptance calorimeter and a stopped pion beam we have made a precise measurement of the rare Pi+ -> Pi0 e+ Nu,(pi_beta) decay branching ratio. We have evaluated the branching ratio by normalizing the number of observed pi_beta decays to the number of observed Pi+ -> e+ Nu, (pi_{e2}) decays. We find the value of Gamma(Pi+ -> Pi0 e+ Nu)/Gamma(total) = [1.036 +/- 0.004(stat.) +/- 0.0…
▽ More
Using a large acceptance calorimeter and a stopped pion beam we have made a precise measurement of the rare Pi+ -> Pi0 e+ Nu,(pi_beta) decay branching ratio. We have evaluated the branching ratio by normalizing the number of observed pi_beta decays to the number of observed Pi+ -> e+ Nu, (pi_{e2}) decays. We find the value of Gamma(Pi+ -> Pi0 e+ Nu)/Gamma(total) = [1.036 +/- 0.004(stat.) +/- 0.004(syst.) +/- 0.003(pi_{e2})] x 10^{-8}$, where the first uncertainty is statistical, the second systematic, and the third is the pi_{e2} branching ratio uncertainty. Our result agrees well with the Standard Model prediction.
△ Less
Submitted 17 July, 2004; v1 submitted 9 December, 2003;
originally announced December 2003.
-
Precise Measurement of the Pion Axial Form Factor in the Pi+ -> e+ nu gamma Decay
Authors:
E. Frlez,
D. Pocanic,
V. A. Baranov,
W. Bertl,
M. Bychkov,
N. V. Khomutov,
A. S. Korenchenko,
S. M. Korenchenko,
T. Kozlowski,
N. P. Kravchuk,
N. A. Kuchinsky,
W. Li,
R. C. Minehart,
D. Mzhavia,
B. G. Ritchie,
S. Ritt,
A. M. Rozhdestvensky,
V. V. Sidorkin,
L. C. Smith,
I. Supek,
Z. Tsamalaidze,
B. A. VanDevender,
E. P. Velicheva,
Y. Wang,
H. -P. Wirtz
, et al. (1 additional authors not shown)
Abstract:
We have studied radiative pion decays Pi+ -> e+ nu gamma in three broad kinematic regions using the PIBETA detector and a stopped pion beam. Based on Dalitz distributions of 42,209 events we have evaluated absolute Pi -> e nu gamma branching ratios in the three regions. Minimum chi^2 fits to the integral and differential (E(e+),E(gamma)) distributions result in the axial-to-vector weak form fact…
▽ More
We have studied radiative pion decays Pi+ -> e+ nu gamma in three broad kinematic regions using the PIBETA detector and a stopped pion beam. Based on Dalitz distributions of 42,209 events we have evaluated absolute Pi -> e nu gamma branching ratios in the three regions. Minimum chi^2 fits to the integral and differential (E(e+),E(gamma)) distributions result in the axial-to-vector weak form factor ratio of gamma = F_A/F_V = 0.443(15),or F_A = 0.0115(4) with F_V = 0.0259. However, deviations from Standard Model predictions in the high-E(gamma)/low-E(e+) kinematic region indicate the need for further theoretical and experimental work.
△ Less
Submitted 9 December, 2003;
originally announced December 2003.
-
Design, Commissioning and Performance of the PIBETA Detector at PSI
Authors:
E. Frlez,
D. Pocanic,
K. A. Assamagan,
Yu. Bagaturia,
V. A. Baranov,
W. Bertl,
Ch. Broennimann,
M. A. Bychkov,
J. F. Crawford,
M. Daum,
Th. Fluegel,
R. Frosch,
R. Horisberger,
V. A. Kalinnikov,
V. V. Karpukhin,
N. V. Khomutov,
J. E. Koglin,
A. S. Korenchenko,
S. M. Korenchenko,
T. Kozlowski,
B. Krause,
N. P. Kravchuk,
N. A. Kuchinsky,
W. Li,
D. W. Lawrence
, et al. (19 additional authors not shown)
Abstract:
We describe the design, construction and performance of the PIBETA detector built for the precise measurement of the branching ratio of pion beta decay, pi+ -> pi0 e+ nu, at the Paul Scherrer Institute. The central part of the detector is a 240-module spherical pure CsI calorimeter covering 3*pi sr solid angle. The calorimeter is supplemented with an active collimator/beam degrader system, an ac…
▽ More
We describe the design, construction and performance of the PIBETA detector built for the precise measurement of the branching ratio of pion beta decay, pi+ -> pi0 e+ nu, at the Paul Scherrer Institute. The central part of the detector is a 240-module spherical pure CsI calorimeter covering 3*pi sr solid angle. The calorimeter is supplemented with an active collimator/beam degrader system, an active segmented plastic target, a pair of low-mass cylindrical wire chambers and a 20-element cylindrical plastic scintillator hodoscope. The whole detector system is housed inside a temperature-controlled lead brick enclosure which in turn is lined with cosmic muon plastic veto counters. Commissioning and calibration data were taken during two three-month beam periods in 1999/2000 with pi+ stop** rates between 1.3*E3 pi+/s and 1.3*E6 pi+/s. We examine the timing, energy and angular detector resolution for photons, positrons and protons in the energy range of 5-150 MeV, as well as the response of the detector to cosmic muons. We illustrate the detector signatures for the assorted rare pion and muon decays and their associated backgrounds.
△ Less
Submitted 4 December, 2003;
originally announced December 2003.
-
Search for NN-decoupled dibaryons using the process $pp \to γγX$ below the pion production threshold
Authors:
A. S. Khrykin,
V. F. Boreiko,
Yu. G. Budyashov,
S. B. Gerasimov,
N. V. Khomutov,
Yu. G. Sobolev,
V. P. Zorin
Abstract:
The energy spectrum for high energy $γ$-rays ($E_γ\geq 10$ MeV) from the process $pp \to γγX$ emitted at $90^0$ in the laboratory frame has been measured at an energy below the pion production threshold, namely, at 216 MeV. The resulting photon energy spectrum extracted from $γ-γ$ coincidence events consists of a narrow peak at a photon energy of about 24 MeV and a relatively broad peak in the e…
▽ More
The energy spectrum for high energy $γ$-rays ($E_γ\geq 10$ MeV) from the process $pp \to γγX$ emitted at $90^0$ in the laboratory frame has been measured at an energy below the pion production threshold, namely, at 216 MeV. The resulting photon energy spectrum extracted from $γ-γ$ coincidence events consists of a narrow peak at a photon energy of about 24 MeV and a relatively broad peak in the energy range of (50 - 70) MeV. The statistical significances for the narrow and broad peaks are 5.3$σ$ and 3.5$σ$, respectively. This behavior of the photon energy spectrum is interpreted as a signature of the exotic dibaryon resonance $d^\star_1$ with a mass of about 1956 MeV which is assumed to be formed in the radiative process $pp \to γd^\star_1$ followed by its electromagnetic decay via the $d^\star_1 \to pp γ$ mode. The experimental spectrum is compared with those obtained by means of Monte Carlo simulations.
△ Less
Submitted 19 June, 2001; v1 submitted 26 December, 2000;
originally announced December 2000.