-
A Model of Fluid-Structure and Biochemical Interactions for Applications to Subclinical Leaflet Thrombosis
Authors:
Aaron Barrett,
Jordan A. Brown,
Margaret Anne Smith,
Andrew Woodward,
John P. Vavalle,
Arash Kheradvar,
Boyce E. Griffith,
Aaron L. Fogelson
Abstract:
Subclinical leaflet thrombosis (SLT) is a potentially serious complication of aortic valve replacement with a bioprosthetic valve in which blood clots form on the replacement valve. SLT is associated with increased risk of transient ischemic attacks and strokes and can progress to clinical leaflet thrombosis. SLT following aortic valve replacement also may be related to subsequent structural valve…
▽ More
Subclinical leaflet thrombosis (SLT) is a potentially serious complication of aortic valve replacement with a bioprosthetic valve in which blood clots form on the replacement valve. SLT is associated with increased risk of transient ischemic attacks and strokes and can progress to clinical leaflet thrombosis. SLT following aortic valve replacement also may be related to subsequent structural valve deterioration, which can impair the durability of the valve replacement. Because of the difficulty in clinical imaging of SLT, models are needed to determine the mechanisms of SLT and could eventually predict which patients will develop SLT. To this end, we develop methods to simulate leaflet thrombosis that combine fluid-structure interaction and a simplified thrombosis model that allows for deposition along the moving leaflets. Additionally, this model can be adapted to model deposition or absorption along other moving boundaries. We present convergence results and quantify the model's ability to realize changes in valve opening and pressures. These new approaches are an important advancement in our tools for modeling thrombosis in which they incorporate both adhesion to the surface of the moving leaflets and feedback to the fluid-structure interaction.
△ Less
Submitted 7 February, 2023; v1 submitted 3 May, 2022;
originally announced May 2022.
-
A Combined Deep-Learning and Deformable-Model Approach to Fully Automatic Segmentation of the Left Ventricle in Cardiac MRI
Authors:
M. R. Avendi,
A. Kheradvar,
H. Jafarkhani
Abstract:
Segmentation of the left ventricle (LV) from cardiac magnetic resonance imaging (MRI) datasets is an essential step for calculation of clinical indices such as ventricular volume and ejection fraction. In this work, we employ deep learning algorithms combined with deformable models to develop and evaluate a fully automatic segmentation tool for the LV from short-axis cardiac MRI datasets. The meth…
▽ More
Segmentation of the left ventricle (LV) from cardiac magnetic resonance imaging (MRI) datasets is an essential step for calculation of clinical indices such as ventricular volume and ejection fraction. In this work, we employ deep learning algorithms combined with deformable models to develop and evaluate a fully automatic segmentation tool for the LV from short-axis cardiac MRI datasets. The method employs deep learning algorithms to learn the segmentation task from the ground true data. Convolutional networks are employed to automatically detect the LV chamber in MRI dataset. Stacked autoencoders are utilized to infer the shape of the LV. The inferred shape is incorporated into deformable models to improve the accuracy and robustness of the segmentation. We validated our method using 45 cardiac MR datasets taken from the MICCAI 2009 LV segmentation challenge and showed that it outperforms the state-of-the art methods. Excellent agreement with the ground truth was achieved. Validation metrics, percentage of good contours, Dice metric, average perpendicular distance and conformity, were computed as 96.69%, 0.94, 1.81mm and 0.86, versus those of 79.2%-95.62%, 0.87-0.9, 1.76-2.97mm and 0.67-0.78, obtained by other methods, respectively.
△ Less
Submitted 24 December, 2015;
originally announced December 2015.
-
High-Speed Acquisition of Free Vortex Formation
Authors:
Ahmad Falahatpisheh,
Arash Kheradvar
Abstract:
The formation of a free-vortex has been captured by using a high-speed camera (Y3, IDTVision, Inc.). The experiment is conducted using a rectangular tank, which is filled with tap water. The water free surface is open to atmospheric pressure and is at room temperature, 25\textcelsius. Water occupies a volume of $25\times 25\times 10$cm$^3$. By using a stirring-spoon, the stagnant water is forced t…
▽ More
The formation of a free-vortex has been captured by using a high-speed camera (Y3, IDTVision, Inc.). The experiment is conducted using a rectangular tank, which is filled with tap water. The water free surface is open to atmospheric pressure and is at room temperature, 25\textcelsius. Water occupies a volume of $25\times 25\times 10$cm$^3$. By using a stirring-spoon, the stagnant water is forced to rotate at a rate of $2π$/sec. Once all the points in the water is rotating, it will be drained from a ball valve, with a diameter of 5mm, from the bottom of the tank and the acquisition starts. The formation of the vortex is captured with a resolution of $352\times 824$ pixels at 200 frames per seconds (fps) and is exported at 5fps and with a resolution of $1280\times 720$ in a "fluid dynamics video". The duration of the video in real time is 3.9 seconds. The slow motion video is 160 seconds. The height of the water remains almost unchanged while acquiring the images.
△ Less
Submitted 15 October, 2012;
originally announced October 2012.