Dynamic Versus Static Oxidation of Nb/Al-AlO$_x$/Nb Trilayer
Authors:
Tannaz Farrahi,
Alan W. Kleinsasser,
Michael Cyberey,
Jie Wang,
Micahel B. Eller,
Jian Z. Zhang,
Anthony R. Kerr,
Joseph G. Lambert,
Robert M. Weikle,
Arthur W. Lichtenberger
Abstract:
High quality Nb-based superconductor-insulator-superconductor (SIS) junctions with Al oxide (AlO$_x$) tunnel barriers grown from Al overlayers are widely reported in the literature. However, the thin barriers required for high critical current density (J$_c$) junctions exhibit defects that result in significant subgap leakage current that is detrimental for many applications. High quality, high-J…
▽ More
High quality Nb-based superconductor-insulator-superconductor (SIS) junctions with Al oxide (AlO$_x$) tunnel barriers grown from Al overlayers are widely reported in the literature. However, the thin barriers required for high critical current density (J$_c$) junctions exhibit defects that result in significant subgap leakage current that is detrimental for many applications. High quality, high-J$_c$ junctions can be realized with AlN$_x$ barriers, but control of J$_c$ is more difficult than with AlO$_x$. It is therefore of interest to study the growth of thin AlO$_x$ barriers with the ultimate goal of achieving high quality, high-J$_c$ AlO$_x$ junctions. In this work, 100\%\ O$_2$ and 2\%\ O$_2$ in Ar gas mixtures are used both statically and dynamically to grow AlO$_x$ tunnel barriers over a large range of oxygen exposures. In situ ellipsometry is used for the first time to extensively measure AlO$_x$ tunnel barrier growth in real time, revealing a number of unexpected patterns. Finally, a set of test junction wafers was fabricated that exhibited the well-known dependence of J$_c$ on oxygen exposure (E) in order to further validate the experimental setup.
△ Less
Submitted 22 June, 2023;
originally announced June 2023.
-
Room Temperature, Quantum-Limited THz Heterodyne Detection? Not Yet
Authors:
J. Zmuidzinas,
B. Karasik,
A. R. Kerr,
M. Pospieszalski
Abstract:
In their article, Wang et al. [1] report a new scheme for THz heterodyne detection using a laser-driven LTG-GaAs photomixer [2, 3] and make the impressive claim of achieving near quantum-limited sensitivity at room temperature. Unfortunately, their experimental methodology is incorrect, and furthermore the paper provides no information on the mixer conversion loss, an important quantity that could…
▽ More
In their article, Wang et al. [1] report a new scheme for THz heterodyne detection using a laser-driven LTG-GaAs photomixer [2, 3] and make the impressive claim of achieving near quantum-limited sensitivity at room temperature. Unfortunately, their experimental methodology is incorrect, and furthermore the paper provides no information on the mixer conversion loss, an important quantity that could readily have been measured and reported as a consistency check. The paper thus offers no reliable experimental evidence that substantiates the claimed sensitivities. To the contrary, the very high value reported for their photomixer impedance strongly suggests that the conversion loss is quite poor and that the actual sensitivity is far worse than claimed.
△ Less
Submitted 30 July, 2019;
originally announced July 2019.
-
Microwave Loss Reduction in Cryogenically Cooled Conductors
Authors:
R. Finger,
A. R. Kerr
Abstract:
Measurements of microwave attenuation at room temperature and 4.2 K have been performed on some conductors commonly used in receiver input circuits. The reduction in loss on cooling is substantial, particularly for copper and plated gold, both of which showed a factor of 3 loss reduction. Copper passivated with benzotriazole shows the same loss as without passivation. The residual resistivity rati…
▽ More
Measurements of microwave attenuation at room temperature and 4.2 K have been performed on some conductors commonly used in receiver input circuits. The reduction in loss on cooling is substantial, particularly for copper and plated gold, both of which showed a factor of 3 loss reduction. Copper passivated with benzotriazole shows the same loss as without passivation. The residual resistivity ratio between room temperature and 4.2 K, deduced from the measurements using the classical skin effect formula, was smaller than the measured DC value to a degree consistent with conduction in the extreme anomalous skin effect regime at cryogenic temperatures. The measurements were made in the 5-10 GHz range. The materials tested were: aluminum alloys 1100-T6 and 6061-O, C101 copper, benzotriazole treated C101 copper, and brass plated with electroformed copper, Pur-A-Gold 125-Au soft gold, and BDT200 bright gold.
△ Less
Submitted 17 September, 2015;
originally announced September 2015.
-
Development of the ALMA-North America Sideband-Separating SIS Mixers
Authors:
Anthony R. Kerr,
Shing-Kuo Pan,
Stéphane M. X. Claude,
Philip Dindo,
Arthur W. Lichtenberger,
Eugene F. Lauria
Abstract:
As the Atacama Large Millimeter/submillimeter Array (ALMA) nears completion, 73 dual-polarization receivers have been delivered for each of Bands 3 (84-116 GHz) and 6 (211-275 GHz). The receivers use sideband-separating superconducting Nb/Al-AlOx/Nb tunnel-junction (SIS) mixers, developed for ALMA to suppress atmospheric noise in the image band. The mixers were designed taking into account dynamic…
▽ More
As the Atacama Large Millimeter/submillimeter Array (ALMA) nears completion, 73 dual-polarization receivers have been delivered for each of Bands 3 (84-116 GHz) and 6 (211-275 GHz). The receivers use sideband-separating superconducting Nb/Al-AlOx/Nb tunnel-junction (SIS) mixers, developed for ALMA to suppress atmospheric noise in the image band. The mixers were designed taking into account dynamic range, input return loss, and signal-to-image conversion (which can be significant in SIS mixers). Typical SSB receiver noise temperatures in Bands 3 and 6 are 30 K and 60 K, resp., and the image rejection is typically 15 dB.
△ Less
Submitted 25 June, 2013;
originally announced June 2013.
-
Large Instrument Development for Radio Astronomy
Authors:
J. R. Fisher,
R. F. Bradley,
W. F. Brisken,
W. D. Cotton,
D. T. Emerson,
A. R. Kerr,
R. J. Lacasse,
M. A. Morgan,
P. J. Napier,
R. D. Norrod,
J. M. Payne,
M. W. Pospieszalski,
A. Symmes,
A. R. Thompson,
J. C. Webber
Abstract:
This white paper offers cautionary observations about the planning and development of new, large radio astronomy instruments. Complexity is a strong cost driver so every effort should be made to assign differing science requirements to different instruments and probably different sites. The appeal of shared resources is generally not realized in practice and can often be counterproductive. Instr…
▽ More
This white paper offers cautionary observations about the planning and development of new, large radio astronomy instruments. Complexity is a strong cost driver so every effort should be made to assign differing science requirements to different instruments and probably different sites. The appeal of shared resources is generally not realized in practice and can often be counterproductive. Instrument optimization is much more difficult with longer lists of requirements, and the development process is longer and less efficient. More complex instruments are necessarily further behind the technology state of the art because of longer development times. Including technology R&D in the construction phase of projects is a growing trend that leads to higher risks, cost overruns, schedule delays, and project de-sco**. There are no technology breakthroughs just over the horizon that will suddenly bring down the cost of collecting area. Advances come largely through careful attention to detail in the adoption of new technology provided by industry and the commercial market. Radio astronomy instrumentation has a very bright future, but a vigorous long-term R&D program not tied directly to specific projects needs to be restored, fostered, and preserved.
△ Less
Submitted 26 August, 2009;
originally announced August 2009.