-
First demonstration of a TES based cryogenic Li$_2$MoO$_4$detector for neutrinoless double beta decay search
Authors:
G. Bratrud,
C. L. Chang,
R. Chen,
E. Cudmore,
E. Figueroa-Feliciano,
Z. Hong,
K. T. Kennard,
S. Lewis,
M. Lisovenko,
L. O. Mateo,
V. Novati,
V. Novosad,
E. Oliveri,
R. Ren,
J. A. Scarpaci,
B. Schmidt,
G. Wang,
L. Winslow,
V. G. Yefremenko,
J. Zhang,
D. Baxter,
M. Hollister,
C. James,
P. Lukens,
D. J. Temples
Abstract:
Cryogenic calorimetric experiments to search for neutrinoless double-beta decay ($0νββ$) are highly competitive, scalable and versatile in isotope. The largest planned detector array, CUPID, is comprised of about 1500 individual Li$_2^{100}$MoO$_{4}$ detector modules with a further scale up envisioned for a follow up experiment (CUPID-1T). In this article, we present a novel detector concept targe…
▽ More
Cryogenic calorimetric experiments to search for neutrinoless double-beta decay ($0νββ$) are highly competitive, scalable and versatile in isotope. The largest planned detector array, CUPID, is comprised of about 1500 individual Li$_2^{100}$MoO$_{4}$ detector modules with a further scale up envisioned for a follow up experiment (CUPID-1T). In this article, we present a novel detector concept targeting this second stage with a low impedance TES based readout for the Li$_2$MoO$_{4}$ absorber that is easily mass-produced and lends itself to a multiplexed readout. We present the detector design and results from a first prototype detector operated at the NEXUS shallow underground facility at Fermilab. The detector is a 2-cm-side cube with 21$\,$g mass that is strongly thermally coupled to its readout chip to allow rise-times of $\sim$0.5$\,$ms. This design is more than one order of magnitude faster than present NTD based detectors and is hence expected to effectively mitigate backgrounds generated through the pile-up of two independent two neutrino decay events coinciding close in time. Together with a baseline resolution of 1.95$\,$keV (FWHM) these performance parameters extrapolate to a background index from pile-up as low as $5\cdot 10^{-6}\,$counts/keV/kg/yr in CUPID size crystals. The detector was calibrated up to the MeV region showing sufficient dynamic range for $0νββ$ searches. In combination with a SuperCDMS HVeV detector this setup also allowed us to perform a precision measurement of the scintillation time constants of Li$_2$MoO$_{4}$. The crystal showed a significant fast scintillation emission with O(10$\,μ$s) time-scale, more than an order below the detector response of presently considered light detectors suggesting the possibility of further progress in pile-up rejection through better light detectors in the future.
△ Less
Submitted 4 June, 2024;
originally announced June 2024.
-
First Measurement of Correlated Charge Noise in Superconducting Qubits at an Underground Facility
Authors:
G. Bratrud,
S. Lewis,
K. Anyang,
A. Colón Cesaní,
T. Dyson,
H. Magoon,
D. Sabhari,
G. Spahn,
G. Wagner,
R. Gualtieri,
N. A. Kurinsky,
R. Linehan,
R. McDermott,
S. Sussman,
D. J. Temples,
S. Uemura,
C. Bathurst,
G. Cancelo,
R. Chen,
A. Chou,
I. Hernandez,
M. Hollister,
L. Hsu,
C. James,
K. Kennard
, et al. (13 additional authors not shown)
Abstract:
We measure space- and time-correlated charge jumps on a four-qubit device, operating 107 meters below the Earth's surface in a low-radiation, cryogenic facility designed for the characterization of low-threshold particle detectors. The rock overburden of this facility reduces the cosmic ray muon flux by over 99% compared to laboratories at sea level. Combined with 4$π$ coverage of a movable lead s…
▽ More
We measure space- and time-correlated charge jumps on a four-qubit device, operating 107 meters below the Earth's surface in a low-radiation, cryogenic facility designed for the characterization of low-threshold particle detectors. The rock overburden of this facility reduces the cosmic ray muon flux by over 99% compared to laboratories at sea level. Combined with 4$π$ coverage of a movable lead shield, this facility enables quantifiable control over the flux of ionizing radiation on the qubit device. Long-time-series charge tomography measurements on these weakly charge-sensitive qubits capture discontinuous jumps in the induced charge on the qubit islands, corresponding to the interaction of ionizing radiation with the qubit substrate. The rate of these charge jumps scales with the flux of ionizing radiation on the qubit package, as characterized by a series of independent measurements on another energy-resolving detector operating simultaneously in the same cryostat with the qubits. Using lead shielding, we achieve a minimum charge jump rate of 0.19$^{+0.04}_{-0.03}$ mHz, almost an order of magnitude lower than that measured in surface tests, but a factor of roughly eight higher than expected based on reduction of ambient gammas alone. We operate four qubits for over 22 consecutive hours with zero correlated charge jumps at length scales above three millimeters.
△ Less
Submitted 27 June, 2024; v1 submitted 7 May, 2024;
originally announced May 2024.
-
Improved Modelling of Detector Response Effects in Phonon-based Crystal Detectors used for Dark Matter Searches
Authors:
M. J. Wilson,
A. Zaytsev,
B. von Krosigk,
I. Alkhatib,
M. Buchanan,
R. Chen,
M. D. Diamond,
E. Figueroa-Feliciano,
S. A. S. Harms,
Z. Hong,
K. T. Kennard,
N. A. Kurinsky,
R. Mahapatra,
N. Mirabolfathi,
V. Novati,
M. Platt,
R. Ren,
A. Sattari,
B. Schmidt,
Y. Wang,
S. Zatschler,
E. Zhang,
A. Zuniga
Abstract:
Various dark matter search experiments employ phonon-based crystal detectors operated at cryogenic temperatures. Some of these detectors, including certain silicon detectors used by the SuperCDMS Collaboration, are able to achieve single-charge sensitivity when a voltage bias is applied across the detector. The total amount of phonon energy measured by such a detector is proportional to the number…
▽ More
Various dark matter search experiments employ phonon-based crystal detectors operated at cryogenic temperatures. Some of these detectors, including certain silicon detectors used by the SuperCDMS Collaboration, are able to achieve single-charge sensitivity when a voltage bias is applied across the detector. The total amount of phonon energy measured by such a detector is proportional to the number of electron-hole pairs created by the interaction. However, crystal impurities and surface effects can cause propagating charges to either become trapped inside the crystal or create additional unpaired charges, producing non-quantized measured energy as a result. A new analytical model for describing these detector response effects in phonon-based crystal detectors is presented. This model improves upon previous versions by demonstrating how the detector response, and thus the measured energy spectrum, is expected to differ depending on the source of events. We use this model to extract detector response parameters for SuperCDMS HVeV detectors, and illustrate how this robust modelling can help statistically discriminate between sources of events in order to improve the sensitivity of dark matter search experiments.
△ Less
Submitted 24 June, 2024; v1 submitted 2 March, 2024;
originally announced March 2024.
-
Performance of a Kinetic Inductance Phonon-Mediated Detector at the NEXUS Cryogenic Facility
Authors:
Dylan J Temples,
Osmond Wen,
Karthik Ramanathan,
Taylor Aralis,
Yen-Yung Chang,
Sunil Golwala,
Lauren Hsu,
Corey Bathurst,
Daniel Baxter,
Daniel Bowring,
Ran Chen,
Enectali Figueroa-Feliciano,
Matthew Hollister,
Christopher James,
Kyle Kennard,
Noah Kurinsky,
Samantha Lewis,
Patrick Lukens,
Valentina Novati,
Runze Ren,
Benjamin Schmidt
Abstract:
Microcalorimeters that leverage microwave kinetic inductance detectors to read out phonon signals in the particle-absorbing target, referred to as kinetic inductance phonon-mediated (KIPM) detectors, offer an attractive detector architecture to probe dark matter (DM) down to the fermionic thermal relic mass limit. A prototype KIPM detector featuring a single aluminum resonator patterned onto a 1-g…
▽ More
Microcalorimeters that leverage microwave kinetic inductance detectors to read out phonon signals in the particle-absorbing target, referred to as kinetic inductance phonon-mediated (KIPM) detectors, offer an attractive detector architecture to probe dark matter (DM) down to the fermionic thermal relic mass limit. A prototype KIPM detector featuring a single aluminum resonator patterned onto a 1-gram silicon substrate was operated in the NEXUS low-background facility at Fermilab for characterization and evaluation of this detector architecture's efficacy for a dark matter search. An energy calibration was performed by exposing the bare substrate to a pulsed source of 470 nm photons, resulting in a baseline resolution on the energy absorbed by the phonon sensor of $2.1\pm0.2$ eV, a factor of two better than the current state-of-the-art, enabled by millisecond-scale quasiparticle lifetimes. However, due to the sub-percent phonon collection efficiency, the resolution on energy deposited in the substrate is limited to $σ_E=318 \pm 28$ eV. We further model the signal pulse shape as a function of device temperature to extract quasiparticle lifetimes, as well as the observed noise spectra, both of which impact the baseline resolution of the sensor.
△ Less
Submitted 6 February, 2024;
originally announced February 2024.
-
Modeling and characterization of TES-based detectors for the Ricochet experiment
Authors:
R. Chen,
E. Figueroa-Feliciano,
G. Bratrud,
C. L. Chang,
L. Chaplinsky,
E. Cudmore,
W. Van De Pontseele,
J. A. Formaggio,
P. Harrington,
S. A. Hertel,
Z. Hong,
K. T. Kennard,
M. Li,
M. Lisovenko,
L. O. Mateo,
D. W. Mayer,
V. Novati,
P. K. Patel,
H. D. Pinckney,
N. Raha,
F. C. Reyes,
A. Rodriguez,
B. Schmidt,
J. Stachurska,
C. Veihmeyer
, et al. (4 additional authors not shown)
Abstract:
Coherent elastic neutrino-nucleus scattering (CE$ν$NS) offers a valuable approach in searching for physics beyond the Standard Model. The Ricochet experiment aims to perform a precision measurement of the CE$ν$NS spectrum at the Institut Laue-Langevin nuclear reactor with cryogenic solid-state detectors. The experiment plans to employ an array of cryogenic thermal detectors, each with a mass aroun…
▽ More
Coherent elastic neutrino-nucleus scattering (CE$ν$NS) offers a valuable approach in searching for physics beyond the Standard Model. The Ricochet experiment aims to perform a precision measurement of the CE$ν$NS spectrum at the Institut Laue-Langevin nuclear reactor with cryogenic solid-state detectors. The experiment plans to employ an array of cryogenic thermal detectors, each with a mass around 30 g and an energy threshold of sub-100 eV. The array includes nine detectors read out by Transition-Edge Sensors (TES). These TES based detectors will also serve as demonstrators for future neutrino experiments with thousands of detectors. In this article we present an update in the characterization and modeling of a prototype TES detector.
△ Less
Submitted 21 November, 2023;
originally announced November 2023.