Universal Sampling Denoising (USD) for noise map** and noise removal of non-Cartesian MRI
Authors:
Hong-Hsi Lee,
Mahesh Bharath Keerthivasan,
Gregory Lemberskiy,
Jiangyang Zhang,
Els Fieremans,
Dmitry S Novikov
Abstract:
Random matrix theory (RMT) combined with principal component analysis has resulted in a widely used MPPCA noise map** and denoising algorithm, that utilizes the redundancy in multiple acquisitions and in local image patches. RMT-based denoising relies on the uncorrelated identically distributed noise. This assumption breaks down after regridding of non-Cartesian sampling. Here we propose a Unive…
▽ More
Random matrix theory (RMT) combined with principal component analysis has resulted in a widely used MPPCA noise map** and denoising algorithm, that utilizes the redundancy in multiple acquisitions and in local image patches. RMT-based denoising relies on the uncorrelated identically distributed noise. This assumption breaks down after regridding of non-Cartesian sampling. Here we propose a Universal Sampling Denoising (USD) pipeline to homogenize the noise level and decorrelate the noise in non-Cartesian sampled k-space data after resampling to a Cartesian grid. In this way, the RMT approaches become applicable to MRI of any non-Cartesian k-space sampling. We demonstrate the denoising pipeline on MRI data acquired using radial trajectories, including diffusion MRI of a numerical phantom and ex vivo mouse brains, as well as in vivo $T_2$ MRI of a healthy subject. The proposed pipeline robustly estimates noise level, performs noise removal, and corrects bias in parametric maps, such as diffusivity and kurtosis metrics, and $T_2$ relaxation time. USD stabilizes the variance, decorrelates the noise, and thereby enables the application of RMT-based denoising approaches to MR images reconstructed from any non-Cartesian data. In addition to MRI, USD may also apply to other medical imaging techniques involving non-Cartesian acquisition, such as PET, CT, and SPECT.
△ Less
Submitted 27 November, 2023;
originally announced November 2023.
-
FastMRI Prostate: A Publicly Available, Biparametric MRI Dataset to Advance Machine Learning for Prostate Cancer Imaging
Authors:
Radhika Tibrewala,
Tarun Dutt,
Angela Tong,
Luke Ginocchio,
Mahesh B Keerthivasan,
Steven H Baete,
Sumit Chopra,
Yvonne W Lui,
Daniel K Sodickson,
Hersh Chandarana,
Patricia M Johnson
Abstract:
The fastMRI brain and knee dataset has enabled significant advances in exploring reconstruction methods for improving speed and image quality for Magnetic Resonance Imaging (MRI) via novel, clinically relevant reconstruction approaches. In this study, we describe the April 2023 expansion of the fastMRI dataset to include biparametric prostate MRI data acquired on a clinical population. The dataset…
▽ More
The fastMRI brain and knee dataset has enabled significant advances in exploring reconstruction methods for improving speed and image quality for Magnetic Resonance Imaging (MRI) via novel, clinically relevant reconstruction approaches. In this study, we describe the April 2023 expansion of the fastMRI dataset to include biparametric prostate MRI data acquired on a clinical population. The dataset consists of raw k-space and reconstructed images for T2-weighted and diffusion-weighted sequences along with slice-level labels that indicate the presence and grade of prostate cancer. As has been the case with fastMRI, increasing accessibility to raw prostate MRI data will further facilitate research in MR image reconstruction and evaluation with the larger goal of improving the utility of MRI for prostate cancer detection and evaluation. The dataset is available at https://fastmri.med.nyu.edu.
△ Less
Submitted 18 April, 2023;
originally announced April 2023.
-
Optimizing Variable Flip-Angles in Magnetization-Prepared Gradient Echo Sequences for Efficient 3D-T1rho Map**
Authors:
Marcelo V W Zibetti,
Hector L. De Moura,
Mahesh B. Keerthivasan,
Ravinder R Regatte
Abstract:
Purpose: To optimize the choice of the flip-angles of magnetization-prepared gradient echo (MP-GRE) sequences for improved accuracy, precision, and speed of 3D-T1rho map**. Methods: We propose a new optimization approach for finding variable flip-angle (VFA) values that improve MP-GRE sequences used for 3D-T1\r{ho} map**. This new approach can simultaneously improve the accuracy and signal-to-…
▽ More
Purpose: To optimize the choice of the flip-angles of magnetization-prepared gradient echo (MP-GRE) sequences for improved accuracy, precision, and speed of 3D-T1rho map**. Methods: We propose a new optimization approach for finding variable flip-angle (VFA) values that improve MP-GRE sequences used for 3D-T1\r{ho} map**. This new approach can simultaneously improve the accuracy and signal-to-noise ratio (SNR) while reducing filtering effects. We demonstrate the concept in the three different versions of the MP-GRE sequences that are typically used for 3D-T1rho map** and evaluate their performance in model agarose phantoms (n=6) and healthy volunteers (n=5) for knee joint imaging. We also tested the optimization with sequence parameters targeting faster acquisitions. Results: Our results show that optimized VFA can improve the accuracy and the precision of the sequences, seen as a reduction of the mean of normalized absolute difference (MNAD) from 6~8% to 4~5% in model phantoms and from 14~22% to 12~14% in the knee joint, and improving SNR from 12~27 to 24~35 in agarose phantoms and 5~13 to 11~16 in healthy volunteers. The optimization can also compensate for the loss in quality caused by making the sequence faster. This results in sequence configurations that acquire nearly twice more data per unit of time with similar SNR and MNAD measurements as compared to its slower versions. Conclusion: The optimization of the VFA can be used to increase accuracy and precision, and improve the speed of the typical imaging sequences used for quantitative 3D-T1rho map** of the knee joint.
△ Less
Submitted 16 November, 2022;
originally announced November 2022.
-
A Contrast Synthesized Thalamic Nuclei Segmentation Scheme using Convolutional Neural Networks
Authors:
Lavanya Umapathy,
Mahesh Bharath Keerthivasan,
Natalie M. Zahr,
Ali Bilgin,
Manojkumar Saranathan
Abstract:
Thalamic nuclei have been implicated in several neurological diseases. WMn-MPRAGE images have been shown to provide better intra-thalamic nuclear contrast compared to conventional MPRAGE images but the additional acquisition results in increased examination times. In this work, we investigated 3D Convolutional Neural Network (CNN) based techniques for thalamic nuclei parcellation from conventional…
▽ More
Thalamic nuclei have been implicated in several neurological diseases. WMn-MPRAGE images have been shown to provide better intra-thalamic nuclear contrast compared to conventional MPRAGE images but the additional acquisition results in increased examination times. In this work, we investigated 3D Convolutional Neural Network (CNN) based techniques for thalamic nuclei parcellation from conventional MPRAGE images. Two 3D CNNs were developed and compared for thalamic nuclei parcellation using MPRAGE images: a) a native contrast segmentation (NCS) and b) a synthesized contrast segmentation (SCS) using WMn-MPRAGE images synthesized from MPRAGE images. We trained the two segmentation frameworks using MPRAGE images (n=35) and thalamic nuclei labels generated on WMn-MPRAGE images using a multi-atlas based parcellation technique. The segmentation accuracy and clinical utility were evaluated on a cohort comprising of healthy subjects and patients with alcohol use disorder (AUD) (n=45). The SCS network yielded higher Dice scores in the Medial geniculate nucleus (P=.003) and Centromedian nucleus (P=.01) with lower volume differences for Ventral anterior (P=.001) and Ventral posterior lateral (P=.01) nuclei when compared to the NCS network. A Bland-Altman analysis revealed tighter limits of agreement with lower coefficient of variation between true volumes and those predicted by the SCS network. The SCS network demonstrated a significant atrophy in Ventral lateral posterior nucleus in AUD patients compared to healthy age-matched controls (P=0.01), agreeing with previous studies on thalamic atrophy in alcoholism, whereas the NCS network showed spurious atrophy of the Ventral posterior lateral nucleus. CNN-based contrast synthesis prior to segmentation can provide fast and accurate thalamic nuclei segmentation from conventional MPRAGE images.
△ Less
Submitted 16 December, 2020;
originally announced December 2020.
-
A Comparison of Deep Learning Convolution Neural Networks for Liver Segmentation in Radial Turbo Spin Echo Images
Authors:
Lavanya Umapathy,
Mahesh Bharath Keerthivasan,
Jean-Phillipe Galons,
Wyatt Unger,
Diego Martin,
Maria I Altbach,
Ali Bilgin
Abstract:
Motion-robust 2D Radial Turbo Spin Echo (RADTSE) pulse sequence can provide a high-resolution composite image, T2-weighted images at multiple echo times (TEs), and a quantitative T2 map, all from a single k-space acquisition. In this work, we use a deep-learning convolutional neural network (CNN) for the segmentation of liver in abdominal RADTSE images. A modified UNET architecture with generalize…
▽ More
Motion-robust 2D Radial Turbo Spin Echo (RADTSE) pulse sequence can provide a high-resolution composite image, T2-weighted images at multiple echo times (TEs), and a quantitative T2 map, all from a single k-space acquisition. In this work, we use a deep-learning convolutional neural network (CNN) for the segmentation of liver in abdominal RADTSE images. A modified UNET architecture with generalized dice loss objective function was implemented. Three 2D CNNs were trained, one for each image type obtained from the RADTSE sequence. On evaluating the performance of the CNNs on the validation set, we found that CNNs trained on TE images or the T2 maps had higher average dice scores than the composite images. This, in turn, implies that the information regarding T2 variation in tissues aids in improving the segmentation performance.
△ Less
Submitted 12 April, 2020;
originally announced April 2020.
-
Automated Thalamic Nuclei Segmentation Using Multi-Planar Cascaded Convolutional Neural Networks
Authors:
Mohammad S Majdi,
Mahesh B Keerthivasan,
Brian K Rutt,
Natalie M Zahr,
Jeffrey J Rodriguez,
Manojkumar Saranathan
Abstract:
A cascaded multi-planar scheme with a modified residual U-Net architecture was used to segment thalamic nuclei on conventional and white-matter-nulled (WMn) magnetization prepared rapid gradient echo (MPRAGE) data. A single network was optimized to work with images from healthy controls and patients with multiple sclerosis (MS) and essential tremor (ET), acquired at both 3T and 7T field strengths.…
▽ More
A cascaded multi-planar scheme with a modified residual U-Net architecture was used to segment thalamic nuclei on conventional and white-matter-nulled (WMn) magnetization prepared rapid gradient echo (MPRAGE) data. A single network was optimized to work with images from healthy controls and patients with multiple sclerosis (MS) and essential tremor (ET), acquired at both 3T and 7T field strengths. Dice similarity coefficient and volume similarity index (VSI) were used to evaluate performance. Clinical utility was demonstrated by applying this method to study the effect of MS on thalamic nuclei atrophy. Segmentation of each thalamus into twelve nuclei was achieved in under a minute. For 7T WMn-MPRAGE, the proposed method outperforms current state-of-the-art on patients with ET with statistically significant improvements in Dice for five nuclei (increase in the range of 0.05-0.18) and VSI for four nuclei (increase in the range of 0.05-0.19), while performing comparably for healthy and MS subjects. Dice and VSI achieved using 7T WMn-MPRAGE data are comparable to those using 3T WMn-MPRAGE data. For conventional MPRAGE, the proposed method shows a statistically significant Dice improvement in the range of 0.14-0.63 over FreeSurfer for all nuclei and disease types. Effect of noise on network performance shows robustness to images with SNR as low as half the baseline SNR. Atrophy of four thalamic nuclei and whole thalamus was observed for MS patients compared to healthy control subjects, after controlling for the effect of parallel imaging, intracranial volume, gender, and age (p<0.004). The proposed segmentation method is fast, accurate, performs well across disease types and field strengths, and shows great potential for improving our understanding of thalamic nuclei involvement in neurological diseases.
△ Less
Submitted 17 June, 2020; v1 submitted 16 December, 2019;
originally announced December 2019.
-
Quantitative T2 Estimation Using Radial Turbo Spin Echo Imaging
Authors:
Mahesh B Keerthivasan,
Ali Bilgin,
Maria I Altbach
Abstract:
There has been increased interest in the quantitative characterization of tissues based on T2 in abdominal imaging. Techniques based on spin-echo or turbo spin-echo sequences are time consuming because they require multiple acquisitions for obtaining an adequate number of TE images for accurate T2 map**. Radial turbo spin echo (RADTSE) based methods have been shown to generate accurate T2 maps f…
▽ More
There has been increased interest in the quantitative characterization of tissues based on T2 in abdominal imaging. Techniques based on spin-echo or turbo spin-echo sequences are time consuming because they require multiple acquisitions for obtaining an adequate number of TE images for accurate T2 map**. Radial turbo spin echo (RADTSE) based methods have been shown to generate accurate T2 maps from a single acquisition using highly undersampled data. In this work, we present details of the RADTSE technique, summarizing developments related to the design of pulse sequence and reconstruction algorithms. Results from phantom and in vivo imaging experiments are also presented.
△ Less
Submitted 10 November, 2019;
originally announced November 2019.
-
T2-weighted Spine Imaging using a Single-Shot Turbo Spin Echo Pulse Sequence
Authors:
Mahesh Bharath Keerthivasan,
Blair Winegar,
Jennifer L Becker,
Manojkumar Saranathan
Abstract:
T2 weighted imaging of the spine is commonly performed using fast spin echo (FSE/TSE) based sequences, resulting in long scan times and vulnerability to motion artifacts. While single shot fast spin echo sequences have been attempted, their adoption has been limited by poor spatial resolution and specific absorption rate (SAR) limitations. We investigate the use of a half-Fourier acquisition singl…
▽ More
T2 weighted imaging of the spine is commonly performed using fast spin echo (FSE/TSE) based sequences, resulting in long scan times and vulnerability to motion artifacts. While single shot fast spin echo sequences have been attempted, their adoption has been limited by poor spatial resolution and specific absorption rate (SAR) limitations. We investigate the use of a half-Fourier acquisition single-shot turbo spin-echo variable flip angle (HASTE-VFA) sequence for T2 weighted spine imaging. A variable refocusing flip angle echo train was first optimized for the spine to improve the point spread function (PSF) and minimize SAR, yielding images with improved spatial resolution and signal-to-noise ratio compared to the constant flip angle sequence. Data was acquired from 29 patients (20 lumbar and thoracolumbar, 9 whole-spine) using conventional fast spin echo and the proposed variable flip angle single-shot sequences. All images were graded by two experienced neuroradiologists in a blinded fashion and scores were assigned based on blurring, motion, artifacts, and noise as well as appearance of disks, facet joints, end plates, nerve roots and the spinal cord.
△ Less
Submitted 8 November, 2019;
originally announced November 2019.