-
Kinetic inductance and voltage response dependence on temperature: Asymmetric dc SQUID case study
Authors:
M. A. Gali Labarias,
O. A. Nieves,
S. T. Keenan,
E. E. Mitchell
Abstract:
Inductance plays a crucial role in the design and optimization of superconducting quantum interference devices (SQUIDs) for quantum sensing applications, since it dictates the sensitivity and coupling ratio with other circuit elements. In high-temperature superconductors the kinetic inductance, which depends on both geometry and temperature, becomes a dominant part of the device's total self-induc…
▽ More
Inductance plays a crucial role in the design and optimization of superconducting quantum interference devices (SQUIDs) for quantum sensing applications, since it dictates the sensitivity and coupling ratio with other circuit elements. In high-temperature superconductors the kinetic inductance, which depends on both geometry and temperature, becomes a dominant part of the device's total self-inductance, since their London penetration depth is considerably larger compared to low-temperature superconductors. In this work, we use an asymmetric SQUID to investigate the kinetic self-inductance ratio and voltage modulation depth at different operating temperatures, device geometries and bias currents. We first validate our approach by comparing our modelled data with experimental measurements. Then, through numerical simulations, we show: (i) kinetic inductance dominates for thin superconducting films, while for thicker films the inductance is less sensitive to temperature changes; (ii) the voltage modulation depth decreases exponentially with the total inductance independent of the asymmetry ratio; (iii) narrower superconducting tracks lead to a broader temperature operation range, $ΔT \sim 30 K$, while wider tracks operate in a smaller temperature range, $ΔT \sim 10 K$, but are more sensitive to temperature changes; and (iv) the device performance versus temperature strongly depends on the bias current used.
△ Less
Submitted 4 July, 2023;
originally announced July 2023.
-
Determining the temperature-dependent London penetration depth in HTS thin films and its effect on SQUID performance
Authors:
Shane Keenan,
Colin Pegrum,
Marc Gali Labarias,
Emma E Mitchell
Abstract:
The optimum design of high-sensitivity Superconducting Quantum Interference Devices (SQUIDs) and other devices based on thin HTS films requires accurate inductance modeling. This needs the London penetration depth $λ$ to be well defined, not only at 77 K, but also for any operating temperature, given the increasingly widespread use of miniature low-noise single-stage cryocoolers. Temperature signi…
▽ More
The optimum design of high-sensitivity Superconducting Quantum Interference Devices (SQUIDs) and other devices based on thin HTS films requires accurate inductance modeling. This needs the London penetration depth $λ$ to be well defined, not only at 77 K, but also for any operating temperature, given the increasingly widespread use of miniature low-noise single-stage cryocoolers. Temperature significantly affects all inductances in any active superconducting device and cooling below 77 K can greatly improve device performance, however accurate data for the temperature dependence of inductance and $λ(T)$ for HTS devices is largely missing in the literature. We report here inductance measurements on a set of 20 different thin-film YBCO SQUIDs at 77 K with thickness $t = 220$ or 113 nm. By combining experimental data and inductance modeling we find an average penetration depth $λ(77) = 391$ nm at 77 K, which was independent of $t$. Using the same methods we derive an empirical expression for $λ(T)$ for a further three SQUIDs measured on a cryocooler from 50 to 79 K. Our measured value of $λ(77)$ and our inductance extraction procedures were then used to estimate the inductances and the effective areas of directly coupled SQUID magnetometers with large washer-style pick-up loops. The latter agree to better than 7% with experimentally-measured values, validating our measured value of $λ(77)$ and our inductance extraction methods.
△ Less
Submitted 28 September, 2021;
originally announced September 2021.
-
Mechanics of Stabbing: Biaxial Measurement of Knife Stab Penetration of Skin Simulant
Authors:
Michael D. Gilchrist,
Stephen Keenan,
Michael Curtis,
Mary Cassidy,
Greg Byrne,
Michel Destrade
Abstract:
In medicolegal situations, the consequences of a stabbing incident are described in terms that are qualitative without being quantitative. Here, the mechanical variables involved in knife-tissue penetration events are used to determine the parameters needed to be controlled in a measurement device. They include knife geometry, in-plane mechanical stress state of skin, angle and speed of knife pe…
▽ More
In medicolegal situations, the consequences of a stabbing incident are described in terms that are qualitative without being quantitative. Here, the mechanical variables involved in knife-tissue penetration events are used to determine the parameters needed to be controlled in a measurement device. They include knife geometry, in-plane mechanical stress state of skin, angle and speed of knife penetration, and underlying fascia. Four household knives with different geometries were used. Synthetic materials were used to simulate the response of skin, fat and cartilage: polyurethane, foam, and ballistic soap, respectively. The force and energy applied by the blade and the skin displacement were used to identify skin penetration. The skin tension is shown to have a direct effect on the force and energy for knife penetration and on the depth of displacement of the simulant prior to penetration: larger levels of in-plane tension in the skin are associated with lower penetration forces, energies and displacements. Less force and energy are required for puncture when the blade is parallel to a direction of greater skin tension than when perpendicular. Surprisingly, evidence suggests that the quality control processes used to manufacture knives fail to produce consistently uniform blade points in nominally identical knives, leading to penetration forces which can vary widely.
△ Less
Submitted 24 November, 2008;
originally announced November 2008.