-
Bounding Box Annotation with Visible Status
Authors:
Takuya Kiyokawa,
Naoki Shirakura,
Hiroki Katayama,
Keita Tomochika,
Jun Takamatsu
Abstract:
Training deep-learning-based vision systems requires the manual annotation of a significant amount of data to optimize several parameters of the deep convolutional neural networks. Such manual annotation is highly time-consuming and labor-intensive. To reduce this burden, a previous study presented a fully automated annotation approach that does not require any manual intervention. The proposed me…
▽ More
Training deep-learning-based vision systems requires the manual annotation of a significant amount of data to optimize several parameters of the deep convolutional neural networks. Such manual annotation is highly time-consuming and labor-intensive. To reduce this burden, a previous study presented a fully automated annotation approach that does not require any manual intervention. The proposed method associates a visual marker with an object and captures it in the same image. However, because the previous method relied on moving the object within the capturing range using a fixed-point camera, the collected image dataset was limited in terms of capturing viewpoints. To overcome this limitation, this study presents a mobile application-based free-viewpoint image-capturing method. With the proposed application, users can collect multi-view image datasets automatically that are annotated with bounding boxes by moving the camera. However, capturing images through human involvement is laborious and monotonous. Therefore, we propose gamified application features to track the progress of the collection status. Our experiments demonstrated that using the gamified mobile application for bounding box annotation, with visible collection progress status, can motivate users to collect multi-view object image datasets with less mental workload and time pressure in an enjoyable manner, leading to increased engagement.
△ Less
Submitted 10 April, 2023;
originally announced April 2023.
-
Analogue black-white hole solitons in travelling wave parametric amplifiers with superconducting nonlinear asymmetric inductive elements
Authors:
Haruna Katayama,
Noriyuki Hatakenaka,
Toshiyuki Fujii,
Miles P. Blencowe
Abstract:
We show that existing travelling wave parametric amplifier (TWPA) setups, using superconducting nonlinear asymmetric inductive elements (SNAILs), admit soliton solutions that act as analogue event horizons. The SNAIL-TWPA circuit dynamics are described by the Korteweg-de Vries (KdV) or modified Korteweg-de Vries (mKdV) equations in the continuum field approximation, depending on the external magne…
▽ More
We show that existing travelling wave parametric amplifier (TWPA) setups, using superconducting nonlinear asymmetric inductive elements (SNAILs), admit soliton solutions that act as analogue event horizons. The SNAIL-TWPA circuit dynamics are described by the Korteweg-de Vries (KdV) or modified Korteweg-de Vries (mKdV) equations in the continuum field approximation, depending on the external magnetic flux bias, and validated numerically. The soliton spatially modulates the velocity for weak probes, resulting in the effective realization of analogue black hole and white hole event horizon pairs. The SNAIL external magnetic flux bias tunability facilitates a three-wave mixing process, which enhances the prospects for observing Hawking photon radiation.
△ Less
Submitted 9 December, 2023; v1 submitted 23 December, 2022;
originally announced December 2022.
-
Active Vapor-Based Robotic Wiper
Authors:
Takuya Kiyokawa,
Hiroki Katayama,
Jun Takamatsu
Abstract:
This paper presents a method for the normal estimation of mirrors and transparent objects that are difficult to recognize with a camera. To create a diffuse reflective surface, we propose spraying water vapor onto transparent or mirror surfaces. In the proposed method, we move an ultrasonic humidifier equipped on the tip of a robotic arm to apply sprayed water vapor onto the plane of a target obje…
▽ More
This paper presents a method for the normal estimation of mirrors and transparent objects that are difficult to recognize with a camera. To create a diffuse reflective surface, we propose spraying water vapor onto transparent or mirror surfaces. In the proposed method, we move an ultrasonic humidifier equipped on the tip of a robotic arm to apply sprayed water vapor onto the plane of a target object to form a cross-shaped misted area. Diffuse reflective surfaces are partially generated as misted areas, which allows the camera to detect the surface of the target object. The viewpoint of the gripper-mounted camera is adjusted such that the extracted misted area appears to be the largest in the image, and finally, the plane normal of the target object surface is estimated. Normal estimation experiments were conducted to evaluate the effectiveness of the proposed method. The RMSEs of the azimuth estimation for the mirror and transparent glass were approximately 4.2 and 5.8 degrees, respectively. Consequently, our robot experiments demonstrate that our robotic wiper can perform contact-force-regulated wi** motions to clean a transparent window, as humans do.
△ Less
Submitted 18 April, 2023; v1 submitted 16 November, 2021;
originally announced November 2021.
-
Robotic Waste Sorter with Agile Manipulation and Quickly Trainable Detector
Authors:
Takuya Kiyokawa,
Hiroki Katayama,
Yuya Tatsuta,
Jun Takamatsu,
Tsukasa Ogasawara
Abstract:
Owing to human labor shortages, the automation of labor-intensive manual waste-sorting is needed. The goal of automating waste-sorting is to replace the human role of robust detection and agile manipulation of waste items with robots. To achieve this, we propose three methods. First, we provide a combined manipulation method using graspless push-and-drop and pick-and-release manipulation. Second,…
▽ More
Owing to human labor shortages, the automation of labor-intensive manual waste-sorting is needed. The goal of automating waste-sorting is to replace the human role of robust detection and agile manipulation of waste items with robots. To achieve this, we propose three methods. First, we provide a combined manipulation method using graspless push-and-drop and pick-and-release manipulation. Second, we provide a robotic system that can automatically collect object images to quickly train a deep neural-network model. Third, we provide a method to mitigate the differences in the appearance of target objects from two scenes: one for dataset collection and the other for waste sorting in a recycling factory. If differences exist, the performance of a trained waste detector may decrease. We address differences in illumination and background by applying object scaling, histogram matching with histogram equalization, and background synthesis to the source target-object images. Via experiments in an indoor experimental workplace for waste-sorting, we confirm that the proposed methods enable quick collection of the training image sets for three classes of waste items (i.e., aluminum can, glass bottle, and plastic bottle) and detection with higher performance than the methods that do not consider the differences. We also confirm that the proposed method enables the robot quickly manipulate the objects.
△ Less
Submitted 4 September, 2021; v1 submitted 2 April, 2021;
originally announced April 2021.
-
Theoretical Studies on Quantum Walks with a Time-varying Coin
Authors:
Haruna Katayama,
Noriyuki Hatakenaka,
Toshiyuki Fujii
Abstract:
Quantum walks can reconstruct quantum algorithms for quantum computation, where the precise controls of quantum state transfers between arbitrary distant sites are required. Here, we investigate quantum walks using a periodically time-varying coin both numerically and analytically, in order to explore the controllability of quantum walks while preserving its random nature.
Quantum walks can reconstruct quantum algorithms for quantum computation, where the precise controls of quantum state transfers between arbitrary distant sites are required. Here, we investigate quantum walks using a periodically time-varying coin both numerically and analytically, in order to explore the controllability of quantum walks while preserving its random nature.
△ Less
Submitted 2 April, 2020;
originally announced April 2020.
-
COMET Phase-I Technical Design Report
Authors:
The COMET Collaboration,
R. Abramishvili,
G. Adamov,
R. R. Akhmetshin,
A. Allin,
J. C. Angélique,
V. Anishchik,
M. Aoki,
D. Aznabayev,
I. Bagaturia,
G. Ban,
Y. Ban,
D. Bauer,
D. Baygarashev,
A. E. Bondar,
C. Cârloganu,
B. Carniol,
T. T. Chau,
J. K. Chen,
S. J. Chen,
Y. E. Cheung,
W. da Silva,
P. D. Dauncey,
C. Densham,
G. Devidze
, et al. (170 additional authors not shown)
Abstract:
The Technical Design for the COMET Phase-I experiment is presented in this paper. COMET is an experiment at J-PARC, Japan, which will search for neutrinoless conversion of muons into electrons in the field of an aluminium nucleus ($μ-e$ conversion, $μ^- N \to e^- N$); a lepton flavor violating process. The experimental sensitivity goal for this process in the Phase-I experiment is…
▽ More
The Technical Design for the COMET Phase-I experiment is presented in this paper. COMET is an experiment at J-PARC, Japan, which will search for neutrinoless conversion of muons into electrons in the field of an aluminium nucleus ($μ-e$ conversion, $μ^- N \to e^- N$); a lepton flavor violating process. The experimental sensitivity goal for this process in the Phase-I experiment is $3.1\times10^{-15}$, or 90 % upper limit of branching ratio of $7\times 10^{-15}$, which is a factor of 100 improvement over the existing limit. The expected number of background events is 0.032. To achieve the target sensitivity and background level, the 3.2 kW 8 GeV proton beam from J-PARC will be used. Two types of detectors, CyDet and StrECAL, will be used for detecting the \mue conversion events, and for measuring the beam-related background events in view of the Phase-II experiment, respectively. Results from simulation on signal and background estimations are also described.
△ Less
Submitted 19 May, 2020; v1 submitted 21 December, 2018;
originally announced December 2018.
-
High-precision CTE measurement of hybrid C/SiC composite for cryogenic space telescopes
Authors:
K. Enya,
N. Yamada,
T. Imai,
Y. Tange,
H. Kaneda,
H. Katayama,
M. Kotani,
K. Maruyama,
M. Naitoh,
T. Nakagawa,
T. Onaka,
M. Suganuma,
T. Ozaki,
M. Kume,
M. R. Krodel
Abstract:
This paper presents highly precise measurements of thermal expansion of a "hybrid" carbon-fiber reinforced silicon carbide composite, HB-Cesic\textregistered - a trademark of ECM, in the temperature region of \sim310-10K. Whilst C/SiC composites have been considered to be promising for the mirrors and other structures of space-borne cryogenic telescopes, the anisotropic thermal expansion has been…
▽ More
This paper presents highly precise measurements of thermal expansion of a "hybrid" carbon-fiber reinforced silicon carbide composite, HB-Cesic\textregistered - a trademark of ECM, in the temperature region of \sim310-10K. Whilst C/SiC composites have been considered to be promising for the mirrors and other structures of space-borne cryogenic telescopes, the anisotropic thermal expansion has been a potential disadvantage of this material. HB-Cesic\textregistered is a newly developed composite using a mixture of different types of chopped, short carbon-fiber, in which one of the important aims of the development was to reduce the anisotropy. The measurements indicate that the anisotropy was much reduced down to 4% as a result of hybridization. The thermal expansion data obtained are presented as functions of temperature using eighth-order polynomials separately for the horizontal (XY-) and vertical (Z-) directions of the fabrication process. The average CTEs and their dispersion (1σ) in the range 293-10K derived from the data for the XY- and Z-directions were 0.805$\pm$0.003\times10$^{-6}$ K$^{-1}$ and 0.837\pm0.001\times10$^{-6}$ K$^{-1}$, respectively. The absolute accuracy and the reproducibility of the present measurements are suggested to be better than 0.01\times10$^{-6}$ K$^{-1}$ and 0.001\times(10)^{-6} K^{-1}, respectively. The residual anisotropy of the thermal expansion was consistent with our previous speculation regarding carbon-fiber, in which the residual anisotropy tended to lie mainly in the horizontal plane.
△ Less
Submitted 12 October, 2011;
originally announced October 2011.
-
Development of the analog ASIC for multi-channel readout X-ray CCD camera
Authors:
Hiroshi Nakajima,
Daisuke Matsuura,
Toshihiro Idehara,
Naohisa Anabuki,
Hiroshi Tsunemi,
John P. Doty,
Hirokazu Ikeda,
Haruyoshi Katayama,
Hisashi Kitamura,
Yukio Uchihori
Abstract:
We report on the performance of an analog application-specific integrated circuit (ASIC) developed aiming for the front-end electronics of the X-ray CCDcamera system onboard the next X-ray astronomical satellite, ASTRO-H. It has four identical channels that simultaneously process the CCD signals. Distinctive capability of analog-to-digital conversion enables us to construct a CCD camera body that…
▽ More
We report on the performance of an analog application-specific integrated circuit (ASIC) developed aiming for the front-end electronics of the X-ray CCDcamera system onboard the next X-ray astronomical satellite, ASTRO-H. It has four identical channels that simultaneously process the CCD signals. Distinctive capability of analog-to-digital conversion enables us to construct a CCD camera body that outputs only digital signals. As the result of the front-end electronics test, it works properly with low input noise of =<30 uV at the pixel rate below 100 kHz. The power consumption is sufficiently low of about 150 mW/chip. The input signal range of 720 mV covers the effective energy range of the typical X-ray photon counting CCD (up to 20 keV). The integrated non-linearity is 0.2% that is similar as those of the conventional CCDs in orbit. We also performed a radiation tolerance test against the total ionizing dose (TID) effect and the single event effect. The irradiation test using 60Co and proton beam showed that the ASIC has the sufficient tolerance against TID up to 200 krad, which absolutely exceeds the expected amount of dose during the period of operating in a low-inclination low-earth orbit. The irradiation of Fe ions with the fluence of 5.2x10^8 Ion/cm2 resulted in no single event latchup (SEL), although there were some possible single event upsets. The threshold against SEL is higher than 1.68 MeV cm^2/mg, which is sufficiently high enough that the SEL event should not be one of major causes of instrument downtime in orbit.
△ Less
Submitted 11 February, 2011;
originally announced February 2011.
-
In Orbit Performance of the MAXI/SSC onboard the ISS
Authors:
Hiroshi Tsunemi,
Hiroshi Tomida,
Haruyoshi Katayama,
Masashi Kimura,
Arata Daikyuji,
Kazuhisa Miyaguchi,
Kentaro Maeda
Abstract:
We report here the in orbit performance of the CCD camera (MAXI/SSC) onboard the International Space Station (ISS). It was commissioned in August, 2009. This is the first all-sky survey mission employing X-ray CCDs. It consists of 32 CCDs each of which is 1 inch square. It is a slit camera with a field of view of 1deg.5x 90deg and scans the sky as the rotation of the ISS. The CCD on the SSC is co…
▽ More
We report here the in orbit performance of the CCD camera (MAXI/SSC) onboard the International Space Station (ISS). It was commissioned in August, 2009. This is the first all-sky survey mission employing X-ray CCDs. It consists of 32 CCDs each of which is 1 inch square. It is a slit camera with a field of view of 1deg.5x 90deg and scans the sky as the rotation of the ISS. The CCD on the SSC is cooled down to the working temperature around -60degC by the combination of the peltier cooler, a loop heat pipe and a radiator. The standard observation mode of the CCD is in a parallel sum mode (64-binning). The CCD functions properly although it suffers an edge glow when the Sun is near the field of view (FOV) which reduces the observation efficiency of the SSC down to about 30%. The performance of the CCD is continuously monitored both by the Mn-K X-rays and by the Cu-K X-rays. There are many sources detected, not only point sources but extended sources. Due to the lack of the effective observation time, we need more observation time to obtain an extended emission analysis extraction process.
△ Less
Submitted 29 January, 2011;
originally announced January 2011.
-
Solid-state Slit Camera (SSC) on Board MAXI
Authors:
Hiroshi Tomida,
Hiroshi Tsunemi,
Masashi Kimura,
Hiroki Kitayama,
Masaru Matsuoka,
Shiro Ueno,
Kazuyoshi Kawasaki,
Haruyoshi Katayama,
Kazuhisa Miyaguchi,
Kentaro Maeda,
Arata Daikyuji,
Naoki Isobe
Abstract:
Solid-state Slit Camera (SSC) is an X-ray camera onboard the MAXI mission of the International Space Station. Two sets of SSC sensors view X-ray sky using charge-coupled devices (CCDs) in 0.5--12\,keV band. The total area for the X-ray detection is about 200\,cm$\rm ^2$ which is the largest among the missions of X-ray astronomy. The energy resolution at the CCD temperature of $-$70 \degc is 145\,e…
▽ More
Solid-state Slit Camera (SSC) is an X-ray camera onboard the MAXI mission of the International Space Station. Two sets of SSC sensors view X-ray sky using charge-coupled devices (CCDs) in 0.5--12\,keV band. The total area for the X-ray detection is about 200\,cm$\rm ^2$ which is the largest among the missions of X-ray astronomy. The energy resolution at the CCD temperature of $-$70 \degc is 145\,eV in full width at the half maximum (FWHM) at 5.9\,keV, and the field of view is 1°.5 (FWHM) $\times$ 90°for each sensor. The SSC could make a whole-sky image with the energy resolution good enough to resolve line emissions, and monitor the whole-sky at the energy band of $<$ 2\,keV for the first time in these decades.
△ Less
Submitted 19 January, 2011;
originally announced January 2011.
-
The MAXI Mission on the ISS: Science and Instruments for Monitoring All Sky X-Ray Images
Authors:
Masaru Matsuoka,
Kazuyoshi Kawasaki,
Shiro Ueno,
Hiroshi Tomida,
Mitsuhiro Kohama,
Motoko Suzuki,
Yasuki Adachi,
Masaki Ishikawa,
Tatehiro Mihara,
Mutsumi Sugizaki,
Naoki Isobe,
Yu** Nakagawa,
Hiroshi Tsunemi,
Emi Miyata,
Nobuyuki Kawai,
Jun Kataoka,
Mikio Morii,
Atsumasa Yoshida,
Hitoshi Negoro,
Motoki Nakajima,
Yoshihiro Ueda,
Hirotaka Chujo,
Kazutaka Yamaoka,
Osamu Yamazaki,
Satoshi Nakahira
, et al. (7 additional authors not shown)
Abstract:
The MAXI (Monitor of All-sky X-ray Image) mission is the first astronomical payload to be installed on the Japanese Experiment Module-Exposed Facility (JEM-EF) on the ISS. It is scheduled for launch in the middle of 2009 to monitor all-sky X-ray objects on every ISS orbit. MAXI will be more powerful than any previous X-ray All Sky Monitor (ASM) payloads, being able to monitor hundreds of AGN. MA…
▽ More
The MAXI (Monitor of All-sky X-ray Image) mission is the first astronomical payload to be installed on the Japanese Experiment Module-Exposed Facility (JEM-EF) on the ISS. It is scheduled for launch in the middle of 2009 to monitor all-sky X-ray objects on every ISS orbit. MAXI will be more powerful than any previous X-ray All Sky Monitor (ASM) payloads, being able to monitor hundreds of AGN. MAXI will provide all sky images of X-ray sources of about 20 mCrab in the energy band of 2-30 keV from observation on one ISS orbit (90 min), about 4.5 mCrab for one day, and about 1 mCrab for one month. A final detectability of MAXI could be 0.2 mCrab for 2 year observations.
△ Less
Submitted 2 June, 2009;
originally announced June 2009.
-
Reproducibility of Non-X-ray Background for the X-ray Imaging Spectrometer aboard Suzaku
Authors:
Noriaki Tawa,
Kiyoshi Hayashida,
Masaaki Nagai,
Hajime Nakamoto,
Hiroshi Tsunemi,
Hiroya Yamaguchi,
Yoshitaka Ishisaki,
Eric Miller,
Tsunefumi Mizuno,
Tadayasu Dotani,
Masanobu Ozaki,
Haruyoshi Katayama
Abstract:
One of the advantages of the X-ray Imaging Spectrometer (XIS) system on board Suzaku is its low and stable non-X-ray background (NXB). In order to make the best use of this advantage, modeling the NXB spectra with high accuracy is important to subtract them from the spectra of on-source observations. We construct an NXB database by collecting XIS events when the dark Earth covers the XIS FOV. Th…
▽ More
One of the advantages of the X-ray Imaging Spectrometer (XIS) system on board Suzaku is its low and stable non-X-ray background (NXB). In order to make the best use of this advantage, modeling the NXB spectra with high accuracy is important to subtract them from the spectra of on-source observations. We construct an NXB database by collecting XIS events when the dark Earth covers the XIS FOV. The total exposure time of the NXB data is about 785 ks for each XIS. It is found that the count rate of the NXB anti-correlates with the cut-off-rigidity and correlates with the count rate of the PIN upper discriminator (PIN-UD) in Hard X-ray Detector on board Suzaku. We thus model the NXB spectrum for a given on-source observation by employing either of these parameters and obtain a better reproducibility of the NXB for the model with PIN-UD than that with the cut-off-rigidity. The reproducibility of the NXB model with PIN-UD is 4.55-5.63% for each XIS NXB in the 1-7 keV band and 2.79-4.36% for each XIS NXB in the 5-12 keV band for each 5 ks exposure of the NXB data. This NXB reproducibility is much smaller than the spatial fluctuation of the cosmic X-ray background in the 1-7 keV band, and is almost comparable to that in the 5-12 keV band.
△ Less
Submitted 5 March, 2008;
originally announced March 2008.
-
X-ray Study of the Dark Matter Distribution in Clusters of Galaxies with Chandra
Authors:
Haruyoshi Katayama,
Kiyoshi Hayashida
Abstract:
We study the total gravitating mass distribution in the central region of 23 clusters of galaxies with Chandra. Using a new deprojection technique, we measure the temperature and gas density in the very central region of the clusters as a function of radius without assuming any particular models. Under the assumptions of hydrostatic equilibrium and spherical symmetry, we obtain the deprojected m…
▽ More
We study the total gravitating mass distribution in the central region of 23 clusters of galaxies with Chandra. Using a new deprojection technique, we measure the temperature and gas density in the very central region of the clusters as a function of radius without assuming any particular models. Under the assumptions of hydrostatic equilibrium and spherical symmetry, we obtain the deprojected mass profiles of these clusters.
The mass profiles are nicely scalable with a characteristic radius ($r_{200}$) and mass ($M_{200}$) on the large scale of $r>0.1r_{200}$. In contrast, the central ($r<0.1r_{200}$) mass profiles have a large scatter even after the scaling. The inner slope $α$ of the total mass density profile ($ρ(r) \propto r^{-α}$) is derived from the slope of the integrated mass profile. The values of the inner slope $α$ at the radius of $0.02r_{200}$ ($α_0$) span a wide range from 0 to 1.2. For 6 out of 20 clusters, $α_0$ is lower than unity at a 90 % confidence level. CDM simulations predict that the inner slope $α$ is in the range $1<α<2$, which is inconsistent with our results. We also found that the gas fraction near the center of a cluster has a negative correlation with $α_0$. Our result suggests that the gas-rich clusters in the central region tend to have a flat core.
△ Less
Submitted 19 May, 2004;
originally announced May 2004.
-
An X-ray measurement of Titan's atmospheric extent from its transit of the Crab Nebula
Authors:
K. Mori,
H. Tsunemi,
H. Katayama,
D. N. Burrows,
G. P. Garmire,
A. E. Metzger
Abstract:
Saturn's largest satellite, Titan, transited the Crab Nebula on 5 January 2003. We observed this astronomical event with the {\it Chandra} X-ray Observatory. An ``occultation shadow'' has clearly been detected and is found to be larger than the diameter of Titan's solid surface. The difference gives a thickness for Titan's atmosphere of 880 $\pm$ 60 km. This is the first measurement of Titan's a…
▽ More
Saturn's largest satellite, Titan, transited the Crab Nebula on 5 January 2003. We observed this astronomical event with the {\it Chandra} X-ray Observatory. An ``occultation shadow'' has clearly been detected and is found to be larger than the diameter of Titan's solid surface. The difference gives a thickness for Titan's atmosphere of 880 $\pm$ 60 km. This is the first measurement of Titan's atmospheric extent at X-ray wavelengths. The value measured is consistent with or slightly larger than those estimated from earlier Voyager observations at other wavelengths. We discuss the possibility of temporal variations in the thickness of Titan's atmosphere.
△ Less
Submitted 11 March, 2004;
originally announced March 2004.
-
Properties of the Brightest Cluster Galaxy and Its Host Cluster
Authors:
Haruyoshi Katayama,
Kiyoshi Hayashida,
Fumio Takahara,
Yutaka Fujita
Abstract:
We investigate the relation between the properties of Brightest Cluster Galaxies (BCGs) and those of their host clusters. To quantify the properties of cluster hot gas, we employ the parameter $Z$ of the fundamental plane of X-ray clusters. It is found that the offset of the BCG from the peak of cluster X-ray emission is larger for smaller $Z$ clusters. The parameter $Z$ (not the redshift {\it z…
▽ More
We investigate the relation between the properties of Brightest Cluster Galaxies (BCGs) and those of their host clusters. To quantify the properties of cluster hot gas, we employ the parameter $Z$ of the fundamental plane of X-ray clusters. It is found that the offset of the BCG from the peak of cluster X-ray emission is larger for smaller $Z$ clusters. The parameter $Z$ (not the redshift {\it z}), which mainly depends on virial density $ρ_{\rm {vir}}$, is considered to represent the formation epoch of a cluster. We thus consider that the offset of the BCG is correlated with the dynamical equilibrium state of its host cluster. On the contrary, no significant correlation is found between the absolute optical magnitude of the BCG and the parameter $Z$. If the extreme brightness of the BCG is mainly acquired in the course of cluster evolution by environmental effect, BCGs are expected to be brighter in large $Z$ clusters. Our result is not consistent with this simplified view. On the contrary, it is possible that the extreme brightness of the BCG is likely to be determined in the early history of cluster collapse.
△ Less
Submitted 13 November, 2002;
originally announced November 2002.
-
Properties of the background of EPIC-pn onboard XMM-Newton
Authors:
H. Katayama,
I. Takahashi,
Y. Ikebe,
K. Matsushita,
M. J. Freyberg
Abstract:
We have investigated the background properties of EPIC-pn onboard XMM-Newton to establish the background subtraction method. Count rates of the background vary violently by two orders of magnitude at the maximum, while during the most quiet period, these are stable within 8 % at a 1 $σ$ level. The overall spectrum is dominated by particle events above 5 keV, and its spatial variation is also fou…
▽ More
We have investigated the background properties of EPIC-pn onboard XMM-Newton to establish the background subtraction method. Count rates of the background vary violently by two orders of magnitude at the maximum, while during the most quiet period, these are stable within 8 % at a 1 $σ$ level. The overall spectrum is dominated by particle events above 5 keV, and its spatial variation is also found. The long-term variation of the background is also investigated with CAL CLOSED data, where the filter wheel was in closed position with the internal calibration source illuminating the sensitive area. The average background count rate decreased by 20 % from March 2000 to January 2001, but it regained in February 2001. For the modeling of the background spectrum, we investigate relations between the 2.0--7.0 keV count rate and some characteristic parameters. The 2.0--7.0 keV background count rate shows a good correlation with the count rate of events outside the field of view. This correlation is usable for the modeling of the background.
△ Less
Submitted 6 October, 2002;
originally announced October 2002.
-
Properties of the background of EPIC onboard XMM-Newton
Authors:
H. Katayama,
I. Takahashi,
Y. Ikebe,
K. Matsushita,
Y. Tanaka,
M. Freyberg
Abstract:
Understanding a background is crucial in particular for a study of low surface brightness objects. In order to establish the background subtraction method, we have studied properties of the EPIC background.
Count rates of the background vary violently by two order of magnitude at the maximum, while during the most quiet period, these are stable within 8 % at a 1 $σ$ level. The overall spectrum…
▽ More
Understanding a background is crucial in particular for a study of low surface brightness objects. In order to establish the background subtraction method, we have studied properties of the EPIC background.
Count rates of the background vary violently by two order of magnitude at the maximum, while during the most quiet period, these are stable within 8 % at a 1 $σ$ level. The overall spectrum is dominated by particle events above 5 keV, and its spatial variation is also found.
The long-term variation of the background is also investigated with CAL CLOSED data, which is the data of calibration source with filter closed. The average background count rate decreased by 20 % from March 2000 to January 2001, but it regained in February 2001.
For the modeling of the background spectrum, we investigate correlations between the 2-10 keV count rate and some characteristic parameters. The PN background shows a good correlation with some parameters. On the other hands, the MOS background does not shows a clear correlation. Further investigation is needed for the MOS background.
Our final goal is to establish a method to predict the background, for which these results will be reflected in the background generator.
△ Less
Submitted 27 January, 2002;
originally announced January 2002.
-
ASCA Observation of the Nearest Gravitational Lensing Cluster Candidate -- A 3408
Authors:
Haruyoshi Katayama,
Kiyoshi Hayashida,
Kiyoshi Hashimotodani
Abstract:
We observed the nearest gravitational lensing cluster candidate, A 3408 (${\it z}=0.042$), with ASCA. The projected mass profile of A 3408 was determined from the ICM temperature and the $β$-model parameters obtained with ASCA, assuming that the hot gas is spherically symmetric and in hydrostatic equilibrium. The projected mass within an arc radius, $r_{\rm arc}$, of 110 kpc is…
▽ More
We observed the nearest gravitational lensing cluster candidate, A 3408 (${\it z}=0.042$), with ASCA. The projected mass profile of A 3408 was determined from the ICM temperature and the $β$-model parameters obtained with ASCA, assuming that the hot gas is spherically symmetric and in hydrostatic equilibrium. The projected mass within an arc radius, $r_{\rm arc}$, of 110 kpc is $M(r_{\rm arc})=1.2^{+0.8}_{-0.4} \times10^{13} \MO$. This is 18 -- 45% of the mass previously derived from a lensing analysis by Campusano et al. (1998, AAA 069.160.189) without any X-ray information.
The primary cause of this discrepancy is in their assumption that the center of the cluster potential coincides with the position of the brightest cluster galaxy (BCG), while we reveal the BCG position to be 60$''$ outside of the X-ray center. We further calculated a model for the source galaxy position and the gravitational potential that can reproduce both the X-ray data and the arc image. In this model, the magnification factor of the lens for the source galaxy was evaluated to be $Δm=$ 0.07$\pm$0.03 mag; i.e., the source galaxy is slightly magnified by the lens cluster A 3408.
△ Less
Submitted 1 November, 2001;
originally announced November 2001.