Beam test measurements of Low Gain Avalanche Detector single pads and arrays for the ATLAS High Granularity Timing Detector
Authors:
C. Allaire,
J. Benitez,
M. Bomben,
G. Calderini,
M. Carulla,
E. Cavallaro,
A. Falou,
D. Flores,
P. Freeman,
Z. Galloway,
E. L. Gkougkousis,
H. Grabas,
S. Grinstein,
B. Gruey,
S. Guindon,
A. M. Henriques Correia,
S. Hidalgo,
A. Kastanas,
C. Labitan,
D. Lacour,
J. Lange,
F. Lanni,
B. Lenzi,
Z. Luce,
N. Makovec
, et al. (19 additional authors not shown)
Abstract:
For the high luminosity upgrade of the LHC at CERN, ATLAS is considering the addition of a High Granularity Timing Detector (HGTD) in front of the end cap and forward calorimeters at |z| = 3.5 m and covering the region 2.4 < |η| < 4 to help reducing the effect of pile-up. The chosen sensors are arrays of 50 μm thin Low Gain Avalanche Detectors (LGAD). This paper presents results on single LGAD sen…
▽ More
For the high luminosity upgrade of the LHC at CERN, ATLAS is considering the addition of a High Granularity Timing Detector (HGTD) in front of the end cap and forward calorimeters at |z| = 3.5 m and covering the region 2.4 < |η| < 4 to help reducing the effect of pile-up. The chosen sensors are arrays of 50 μm thin Low Gain Avalanche Detectors (LGAD). This paper presents results on single LGAD sensors with a surface area of 1.3x1.3 mm2 and arrays with 2x2 pads with a surface area of 2x2 mm^2 or 3x3 mm^2 each and different implant doses of the p+ multiplication layer. They are obtained from data collected during a beam test campaign in Autumn 2016 with a pion beam of 120 GeV energy at the CERN SPS. In addition to several quantities measured inclusively for each pad, the gain, efficiency and time resolution have been estimated as a function of the position of the incident particle inside the pad by using a beam telescope with a position resolution of few μm. Different methods to measure the time resolution are compared, yielding consistent results. The sensors with a surface area of 1.3x1.3 mm^2 have a time resolution of about 40 ps for a gain of 20 and of about 27 ps for a gain of 50 and fulfill the HGTD requirements. Larger sensors have, as expected, a degraded time resolution. All sensors show very good efficiency and time resolution uniformity.
△ Less
Submitted 9 August, 2018; v1 submitted 2 April, 2018;
originally announced April 2018.
Production and Integration of the ATLAS Insertable B-Layer
Authors:
B. Abbott,
J. Albert,
F. Alberti,
M. Alex,
G. Alimonti,
S. Alkire,
P. Allport,
S. Altenheiner,
L. Ancu,
E. Anderssen,
A. Andreani,
A. Andreazza,
B. Axen,
J. Arguin,
M. Backhaus,
G. Balbi,
J. Ballansat,
M. Barbero,
G. Barbier,
A. Bassalat,
R. Bates,
P. Baudin,
M. Battaglia,
T. Beau,
R. Beccherle
, et al. (352 additional authors not shown)
Abstract:
During the shutdown of the CERN Large Hadron Collider in 2013-2014, an additional pixel layer was installed between the existing Pixel detector of the ATLAS experiment and a new, smaller radius beam pipe. The motivation for this new pixel layer, the Insertable B-Layer (IBL), was to maintain or improve the robustness and performance of the ATLAS tracking system, given the higher instantaneous and i…
▽ More
During the shutdown of the CERN Large Hadron Collider in 2013-2014, an additional pixel layer was installed between the existing Pixel detector of the ATLAS experiment and a new, smaller radius beam pipe. The motivation for this new pixel layer, the Insertable B-Layer (IBL), was to maintain or improve the robustness and performance of the ATLAS tracking system, given the higher instantaneous and integrated luminosities realised following the shutdown. Because of the extreme radiation and collision rate environment, several new radiation-tolerant sensor and electronic technologies were utilised for this layer. This paper reports on the IBL construction and integration prior to its operation in the ATLAS detector.
△ Less
Submitted 6 June, 2018; v1 submitted 2 March, 2018;
originally announced March 2018.