Skip to main content

Showing 1–17 of 17 results for author: Karstensen, S

.
  1. arXiv:2010.12076  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Conceptual Design of BabyIAXO, the intermediate stage towards the International Axion Observatory

    Authors: A. Abeln, K. Altenmüller, S. Arguedas Cuendis, E. Armengaud, D. Attié, S. Aune, S. Basso, L. Bergé, B. Biasuzzi, P. T. C. Borges De Sousa, P. Brun, N. Bykovskiy, D. Calvet, J. M. Carmona, J. F. Castel, S. Cebrián, V. Chernov, F. E. Christensen, M. M. Civitani, C. Cogollos, T. Dafní, A. Derbin, K. Desch, D. Díez, M. Dinter , et al. (101 additional authors not shown)

    Abstract: This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for… ▽ More

    Submitted 4 March, 2021; v1 submitted 22 October, 2020; originally announced October 2020.

    Comments: 77 pages, 49 figures. Prepared for submission to JHEP. Third version after referees comments

  2. Tunable and precise two-bunch generation at FLASHForward

    Authors: S. Schröder, K. Ludwig, A. Aschikhin, R. D'Arcy, M. Dinter, P. Gonzalez, S. Karstensen, A. Knetsch, V. Libov, C. A. Lindstrøm, F. Marutzky, P. Niknejadi, A. Rahali, L. Schaper, A. Schleiermacher, B. Schmidt, S. Thiele, A. de Zubiaurre Wagner, S. Wesch, J. Osterhoff

    Abstract: Beam-driven plasma-wakefield acceleration based on external injection has the potential to significantly reduce the size of future accelerators. Stability and quality of the acceleration process substantially depends on the incoming bunch parameters. Precise control of the current profile is essential for optimising energy-transfer efficiency and preserving energy spread. At the FLASHForward facil… ▽ More

    Submitted 25 May, 2020; originally announced May 2020.

    Comments: 7 pages, 5 figures, to be published in the proceedings of the 4th European Advanced Accelerator Concepts Workshop, 15-21 September 2019, La Biodola Bay, Isola d'Elba, Italy

    Report number: DESY 20-039

    Journal ref: J. Phys.: Conf. Ser. 1596, 012002 (2020)

  3. arXiv:1905.03693  [pdf, other

    physics.acc-ph physics.plasm-ph

    FLASHForward: Plasma-wakefield accelerator science for high-average-power applications

    Authors: R. D'Arcy, A. Aschikhin, S. Bohlen, G. Boyle, T. Brümmer, J. Chappell, S. Diederichs, B. Foster, M. J. Garland, L. Goldberg, P. Gonzalez, S. Karstensen, A. Knetsch, P. Kuang, V. Libov, K. Ludwig, A. Martinez de la Ossa, F. Marutzky, M. Meisel, T. J. Mehrling, P. Niknejadi, K. Poder, P. Pourmoussavi, M. Quast, J. -H. Röckemann , et al. (11 additional authors not shown)

    Abstract: The FLASHForward experimental facility is a high-performance test-bed for precision plasma-wakefield research, aiming to accelerate high-quality electron beams to GeV-levels in a few centimetres of ionised gas. The plasma is created by ionising gas in a gas cell either by a high-voltage discharge or a high-intensity laser pulse. The electrons to be accelerated will either be injected internally fr… ▽ More

    Submitted 9 May, 2019; originally announced May 2019.

  4. arXiv:1509.00617  [pdf, other

    physics.ins-det hep-ex

    Shower development of particles with momenta from 15 GeV to 150 GeV in the CALICE scintillator-tungsten hadronic calorimeter

    Authors: The CALICE collaboration, M. Chefdeville, Y. Karyotakis, J. Repond, J. Schlereth, L. Xia, G. Eigen, J. S. Marshall, M. A. Thomson, D. R. Ward, N. Alipour Tehrani, J. Apostolakis, D. Dannheim, K. Elsener, G. Folger, C. Grefe, V. Ivantchenko, M. Killenberg, W. Klempt, E. van der Kraaij, L. Linssen, A. -I. Lucaci-Timoce, A. Münnich, S. Poss, A. Ribon , et al. (158 additional authors not shown)

    Abstract: We present a study of showers initiated by electrons, pions, kaons, and protons with momenta from 15 GeV to 150 GeV in the highly granular CALICE scintillator-tungsten analogue hadronic calorimeter. The data were recorded at the CERN Super Proton Synchrotron in 2011. The analysis includes measurements of the calorimeter response to each particle type as well as measurements of the energy resolutio… ▽ More

    Submitted 11 December, 2015; v1 submitted 2 September, 2015; originally announced September 2015.

    Comments: 35 pages, 21 figures, 8 tables

    Journal ref: 2015 JINST 10 P12006

  5. The FLASHForward Facility at DESY

    Authors: A. Aschikhin, C. Behrens, S. Bohlen, J. Dale, N. Delbos, L. di Lucchio, E. Elsen, J. -H. Erbe, M. Felber, B. Foster, L. Goldberg, J. Grebenyuk, J. -N. Gruse, B. Hidding, Zhanghu Hu, S. Karstensen, A. Knetsch, O. Kononenko, V. Libov, K. Ludwig, A. R. Maier, A. Martinez de la Ossa, T. Mehrling, C. A. J. Palmer, F. Pannek , et al. (13 additional authors not shown)

    Abstract: The FLASHForward project at DESY is a pioneering plasma-wakefield acceleration experiment that aims to produce, in a few centimetres of ionised hydrogen, beams with energy of order GeV that are of quality sufficient to be used in a free-electron laser. The plasma wave will be driven by high-current density electron beams from the FLASH linear accelerator and will explore both external and internal… ▽ More

    Submitted 18 August, 2015; v1 submitted 13 August, 2015; originally announced August 2015.

    Comments: 19 pages, 9 figures

    Report number: DESY 15-143

  6. arXiv:1412.2653  [pdf, other

    physics.ins-det hep-ex

    Pion and proton showers in the CALICE scintillator-steel analogue hadron calorimeter

    Authors: The CALICE Collaboration, B. Bilki, J. Repond, L. Xia, G. Eigen, M. A. Thomson, D. R. Ward, D. Benchekroun, A. Hoummada, Y. Khoulaki, S. Chang, A. Khan, D. H. Kim, D. J. Kong, Y. D. Oh, G. C. Blazey, A. Dyshkant, K. Francis, J. G. R. Lima, R. Salcido, V. Zutshi, F. Salvatore, K. Kawagoe, Y. Miyazaki, Y. Sudo , et al. (147 additional authors not shown)

    Abstract: Showers produced by positive hadrons in the highly granular CALICE scintillator-steel analogue hadron calorimeter were studied. The experimental data were collected at CERN and FNAL for single particles with initial momenta from 10 to 80 GeV/c. The calorimeter response and resolution and spatial characteristics of shower development for proton- and pion-induced showers for test beam data and simul… ▽ More

    Submitted 15 March, 2015; v1 submitted 8 December, 2014; originally announced December 2014.

    Comments: 26 pages, 16 figures, JINST style, changes in the author list, typos corrected, new section added, figures regrouped. Accepted for publication in JINST

  7. arXiv:1404.6454  [pdf, other

    physics.ins-det hep-ex

    The Time Structure of Hadronic Showers in highly granular Calorimeters with Tungsten and Steel Absorbers

    Authors: C. Adloff, J. -J. Blaising, M. Chefdeville, C. Drancourt, R. Gaglione, N. Geffroy, Y. Karyotakis, I. Koletsou, J. Prast, G. Vouters J. Repond, J. Schlereth, L. Xia E. Baldolemar, J. Li, S. T. Park, M. Sosebee, A. P. White, J. Yu, G. Eigen, M. A. Thomson, D. R. Ward, D. Benchekroun, A. Hoummada, Y. Khoulaki J. Apostolakis, S. Arfaoui, M. Benoit , et al. (188 additional authors not shown)

    Abstract: The intrinsic time structure of hadronic showers influences the timing capability and the required integration time of hadronic calorimeters in particle physics experiments, and depends on the active medium and on the absorber of the calorimeter. With the CALICE T3B experiment, a setup of 15 small plastic scintillator tiles read out with Silicon Photomultipliers, the time structure of showers is m… ▽ More

    Submitted 21 July, 2014; v1 submitted 25 April, 2014; originally announced April 2014.

    Comments: 24 pages including author list, 9 figures, published in JINST

    Report number: MPP-2014-147

    Journal ref: JINST 9 (2014) P07022

  8. arXiv:1311.3761  [pdf, ps, other

    physics.ins-det hep-ex

    Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter

    Authors: CALICE Collaboration, K. Francis, J. Repond, J. Schlereth, J. Smith, L. Xia, E. Baldolemar, J. Li, S. T. Park, M. Sosebee, A. P. White, J. Yu, G. Eigen, Y. Mikami, N. K. Watson, M. A. Thomson, D. R. Ward, D. Benchekroun, A. Hoummada, Y. Khoulaki, J. Apostolakis, A. Dotti, G. Folger, V. Ivantchenko, A. Ribon , et al. (169 additional authors not shown)

    Abstract: A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype's performance is presented in terms of the linearity and resolution of the energy measur… ▽ More

    Submitted 11 June, 2014; v1 submitted 15 November, 2013; originally announced November 2013.

    Journal ref: Nuclear Inst. and Methods in Physics Research, A (2014), pp. 278-289

  9. Shower development of particles with momenta from 1 to 10 GeV in the CALICE Scintillator-Tungsten HCAL

    Authors: C. Adloff, J. -J. Blaising, M. Chefdeville, C. Drancourt, R. Gaglione, N. Geffroy, Y. Karyotakis, I. Koletsou, J. Prast, G. Vouters, J. Repond, J. Schlereth, J. Smith, L. Xia, E. Baldolemar, J. Li, S. T. Park, M. Sosebee, A. P. White, J. Yu, G. Eigen, M. A. Thomson, D. R. Ward, D. Benchekroun, A. Hoummada , et al. (194 additional authors not shown)

    Abstract: Lepton colliders are considered as options to complement and to extend the physics programme at the Large Hadron Collider. The Compact Linear Collider (CLIC) is an $e^+e^-$ collider under development aiming at centre-of-mass energies of up to 3 TeV. For experiments at CLIC, a hadron sampling calorimeter with tungsten absorber is proposed. Such a calorimeter provides sufficient depth to contain hig… ▽ More

    Submitted 13 January, 2014; v1 submitted 14 November, 2013; originally announced November 2013.

    Comments: 28 pages, 23 figures, 3 tables

    Journal ref: JINST 9 P01004 January 2014

  10. arXiv:1306.3037  [pdf, ps, other

    physics.ins-det hep-ex

    Validation of GEANT4 Monte Carlo Models with a Highly Granular Scintillator-Steel Hadron Calorimeter

    Authors: C. Adloff, J. Blaha, J. -J. Blaising, C. Drancourt, A. Espargilière, R. Gaglione, N. Geffroy, Y. Karyotakis, J. Prast, G. Vouters, K. Francis, J. Repond, J. Schlereth, J. Smith, L. Xia, E. Baldolemar, J. Li, S. T. Park, M. Sosebee, A. P. White, J. Yu, T. Buanes, G. Eigen, Y. Mikami, N. K. Watson , et al. (148 additional authors not shown)

    Abstract: Calorimeters with a high granularity are a fundamental requirement of the Particle Flow paradigm. This paper focuses on the prototype of a hadron calorimeter with analog readout, consisting of thirty-eight scintillator layers alternating with steel absorber planes. The scintillator plates are finely segmented into tiles individually read out via Silicon Photomultipliers. The presented results are… ▽ More

    Submitted 15 June, 2014; v1 submitted 13 June, 2013; originally announced June 2013.

    Journal ref: JINST 8 P07005 2013

  11. arXiv:1305.7027  [pdf, other

    physics.ins-det hep-ex

    Track segments in hadronic showers in a highly granular scintillator-steel hadron calorimeter

    Authors: CALICE Collaboration, C. Adloff, J. -J. Blaising, M. Chefdeville, C. Drancourt, R. Gaglione, N. Geffroy, Y. Karyotakis, I. Koletsou, J. Prast, G. Vouters, K. Francis, J. Repond, J. Schlereth, J. Smith, L. Xia, E. Baldolemar, J. Li, S. T. Park, M. Sosebee, A. P. White, J. Yu, G. Eigen, Y. Mikami, N. K. Watson , et al. (184 additional authors not shown)

    Abstract: We investigate the three dimensional substructure of hadronic showers in the CALICE scintillator-steel hadronic calorimeter. The high granularity of the detector is used to find track segments of minimum ionising particles within hadronic showers, providing sensitivity to the spatial structure and the details of secondary particle production in hadronic cascades. The multiplicity, length and angul… ▽ More

    Submitted 29 July, 2013; v1 submitted 30 May, 2013; originally announced May 2013.

    Comments: 27 pages, 17 figures, accepted for publication in JINST

    Report number: MPP-2013-143

  12. arXiv:1207.4210  [pdf, other

    physics.ins-det hep-ex

    Hadronic energy resolution of a highly granular scintillator-steel hadron calorimeter using software compensation techniques

    Authors: CALICE Collaboration, C. Adloff, J. Blaha, J. -J. Blaising, C. Drancourt, A. Espargilière, R. Gaglione, N. Geffroy, Y. Karyotakis, J. Prast, G. Vouters, K. Francis, J. Repond, J. Smith, L. Xia, E. Baldolemar, J. Li, S. T. Park, M. Sosebee, A. P. White, J. Yu, T. Buanes, G. Eigen, Y. Mikami, N. K. Watson , et al. (142 additional authors not shown)

    Abstract: The energy resolution of a highly granular 1 m3 analogue scintillator-steel hadronic calorimeter is studied using charged pions with energies from 10 GeV to 80 GeV at the CERN SPS. The energy resolution for single hadrons is determined to be approximately 58%/sqrt(E/GeV}. This resolution is improved to approximately 45%/sqrt(E/GeV) with software compensation techniques. These techniques take advan… ▽ More

    Submitted 27 September, 2012; v1 submitted 17 July, 2012; originally announced July 2012.

    Comments: 26 pages, 14 figures

    Report number: MPP-2012-116

    Journal ref: JINST 7 P09017 (2012)

  13. Electromagnetic response of a highly granular hadronic calorimeter

    Authors: C. Adloff, J. Blaha, J. -J. Blaising, C. Drancourt, A. Espargilière, R. Gaglione, N. Geffroy, Y. Karyotakis, J. Prast, G. Vouters, K. Francis, J. Repond, J. Smith, L. Xia, E. Baldolemar, J. Li, S. T. Park, M. Sosebee, A. P. White, J. Yu, Y. Mikami, N. K. Watson T. Goto, G. Mavromanolakis, M. A. Thomson, D. R. Ward W. Yan , et al. (142 additional authors not shown)

    Abstract: The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic calorimeter, one option is a highly granular sampling calorimeter with steel as absorber and scintillator layers as active material. High granularity is obtained by segmenting the scintillator into small tiles individuall… ▽ More

    Submitted 8 June, 2011; v1 submitted 20 December, 2010; originally announced December 2010.

    Report number: DESY 10-241

    Journal ref: JINST 6 (2011) P04003

  14. arXiv:1004.4996  [pdf, ps, other

    physics.ins-det hep-ex

    Study of the interactions of pions in the CALICE silicon-tungsten calorimeter prototype

    Authors: C. Adloff, Y. Karyotakis, J. Repond, J. Yu, G. Eigen, Y. Mikami, N. K. Watson, J. A. Wilson, T. Goto, G. Mavromanolakis, M. A. Thomson, D. R. Ward, W. Yan, D. Benchekroun, A. Hoummada, Y. Khoulaki, J. Apostolakis, A. Ribon, V. Uzhinskiy, M. Benyamna, C. Cârloganu, F. Fehr, P. Gay, G. C. Blazey, D. Chakraborty , et al. (133 additional authors not shown)

    Abstract: A prototype silicon-tungsten electromagnetic calorimeter for an ILC detector was tested in 2007 at the CERN SPS test beam. Data were collected with electron and hadron beams in the energy range 8 to 80 GeV. The analysis described here focuses on the interactions of pions in the calorimeter. One of the main objectives of the CALICE program is to validate the Monte Carlo tools available for the… ▽ More

    Submitted 28 April, 2010; originally announced April 2010.

    Journal ref: JINST 5:P05007,2010

  15. arXiv:1003.2662  [pdf, other

    physics.ins-det hep-ex

    Construction and Commissioning of the CALICE Analog Hadron Calorimeter Prototype

    Authors: C. Adloff, Y. Karyotakis, J. Repond, A. Brandt, H. Brown, K. De, C. Medina, J. Smith, J. Li, M. Sosebee, A. White, J. Yu, T. Buanes, G. Eigen, Y. Mikami, O. Miller, N. K. Watson, J. A. Wilson, T. Goto, G. Mavromanolakis, M. A. Thomson, D. R. Ward, W. Yan, D. Benchekroun, A. Hoummada , et al. (205 additional authors not shown)

    Abstract: An analog hadron calorimeter (AHCAL) prototype of 5.3 nuclear interaction lengths thickness has been constructed by members of the CALICE Collaboration. The AHCAL prototype consists of a 38-layer sandwich structure of steel plates and highly-segmented scintillator tiles that are read out by wavelength-shifting fibers coupled to SiPMs. The signal is amplified and shaped with a custom-designed ASIC.… ▽ More

    Submitted 12 March, 2010; originally announced March 2010.

    Comments: 36 pages, 32 figures

    Report number: DESY 10-032

    Journal ref: JINST 5 (2010) P05004

  16. arXiv:0811.3228  [pdf

    physics.ins-det hep-ex

    Fast and reasonable Installation, Experience and Acceptance of a Remote Control Room

    Authors: R. Eisberg, E. Garutti, R. Kammering, A. Kaplan, S. Karstensen, B. Lutz, N. Meyer, R. Poeschl, B. Warmbein

    Abstract: Remote control systems are becoming more and more important to give us the flexibility to control facilities, provide assistance and intervene in case of problems at any time and from every place. As a global operating group CALICE [2] with approx. 220 members worldwide is dependent on using a remote control system for shifts and monitoring of the data taking. CALICE has at present installed its… ▽ More

    Submitted 19 November, 2008; originally announced November 2008.

    Comments: 4 pages

  17. Test Results on the Silicon Pixel Detector for the TTF-FEL Beam Trajectory Monitor

    Authors: S. Hillert, R. Ischebeck, U. C. Müller, S. Roth, K. Hansen, P. Holl, S. Karstensen, J. Kemmer, R. Klanner, P. Lechner, M. Leenen, J. S. T. Ng, P. Schmüser, L. Strüder

    Abstract: Test measurements on the silicon pixel detector for the beam trajectory monitor at the free electron laser of the TESLA test facility are presented. To determine the electronic noise of detector and read-out and to calibrate the signal amplitude of different pixels the 6 keV photons of the manganese K line are used. Two different methods determine the spatial accuracy of the detector: In one set… ▽ More

    Submitted 25 April, 2000; originally announced April 2000.

    Comments: 14 pages (Latex), 13 figures (Postscript), submitted to Nuclear Instruments and Methods A

    Report number: DESY 00-065

    Journal ref: Nucl.Instrum.Meth.A458:710-719,2001