Implementation of Design Changes Towards a More Reliable, Hands-off Magnetron Ion Source
Authors:
A. Sosa,
D. S. Bollinger,
P. R. Karns,
C. Y. Tan
Abstract:
As the main $H^{-}$ ion source for the accelerator complex, magnetron ion sources have been used at Fermilab since the 1970s. At the offline test stand, new R&D is carried out to develop and upgrade the present magnetron-type sources of $H^{-}$ ions of up to 80 mA and 35 keV beam energy in the context of the Proton Improvement Plan. The aim of this plan is to provide high-power proton beams for th…
▽ More
As the main $H^{-}$ ion source for the accelerator complex, magnetron ion sources have been used at Fermilab since the 1970s. At the offline test stand, new R&D is carried out to develop and upgrade the present magnetron-type sources of $H^{-}$ ions of up to 80 mA and 35 keV beam energy in the context of the Proton Improvement Plan. The aim of this plan is to provide high-power proton beams for the experiments at FNAL. In order to reduce the amount of tuning and monitoring of these ion sources, a new electronic system consisting of a current-regulated arc discharge modulator allow the ion source to run at a constant arc current for improved beam output and operation. A solenoid-type gas valve feeds $H_{2}$ gas into the source precisely and independently of ambient temperature. This summary will cover several studies and design changes that have been tested and will eventually be implemented on the operational magnetron sources at Fermilab. Innovative results for this type of ion source include cathode geometries, solenoid gas valves, current controlled arc pulser, cesium boiler redesign, gas mixtures of hydrogen and nitrogen, and duty factor reduction, with the aim to improve source lifetime, stability, and reducing the amount of tuning needed. In this summary, I will highlight the advances made in ion sources at Fermilab and will outline the directions of the continuing R&D effort.
△ Less
Submitted 4 May, 2018;
originally announced May 2018.
-
Recent Operation of the FNAL Magnetron $H^{-}$ Ion Source
Authors:
P. R. Karns,
D. S. Bollinger,
A. Sosa
Abstract:
This paper will detail changes in the operational paradigm of the Fermi National Accelerator Laboratory (FNAL) magnetron $H^{-}$ ion source due to upgrades in the accelerator system. Prior to November of 2012 the $H^{-}$ ions for High Energy Physics (HEP) experiments were extracted at ~18 keV vertically downward into a 90 degree bending magnet and accelerated through a Cockcroft-Walton acceleratin…
▽ More
This paper will detail changes in the operational paradigm of the Fermi National Accelerator Laboratory (FNAL) magnetron $H^{-}$ ion source due to upgrades in the accelerator system. Prior to November of 2012 the $H^{-}$ ions for High Energy Physics (HEP) experiments were extracted at ~18 keV vertically downward into a 90 degree bending magnet and accelerated through a Cockcroft-Walton accelerating column to 750 keV. Following the upgrade in the fall of 2012 the $H^{-}$ ions are now directly extracted from a magnetron at 35 keV and accelerated to 750 keV by a Radio Frequency Quadrupole (RFQ). This change in extraction energy as well as the orientation of the ion source required not only a redesign of the ion source, but an updated understanding of its operation at these new values. Discussed in detail are the changes to the ion source timing, arc discharge current, hydrogen gas pressure, and cesium delivery system that were needed to maintain consistent operation at >99% uptime for HEP, with an increased ion source lifetime of over 9 months.
△ Less
Submitted 26 April, 2017;
originally announced April 2017.
-
Performance Characterization of a Solenoid-type Gas Valve for the $H^{-}$ Magnetron Source at FNAL
Authors:
A. Sosa,
D. S. Bollinger,
P. R. Karns
Abstract:
The magnetron-style $H^{-}$ ion sources currently in operation at Fermilab use piezoelectric gas valves to function. This kind of gas valve is sensitive to small changes in ambient temperature, which affect the stability and performance of the ion source. This motivates the need to find an alternative way of feeding H2 gas into the source. A solenoid-type gas valve has been characterized in a dedi…
▽ More
The magnetron-style $H^{-}$ ion sources currently in operation at Fermilab use piezoelectric gas valves to function. This kind of gas valve is sensitive to small changes in ambient temperature, which affect the stability and performance of the ion source. This motivates the need to find an alternative way of feeding H2 gas into the source. A solenoid-type gas valve has been characterized in a dedicated off-line test stand to assess the feasibility of its use in the operational ion sources. $H^{-}$ ion beams have been extracted at 35 keV using this valve. In this study, the performance of the solenoid gas valve has been characterized measuring the beam current output of the magnetron source with respect to the voltage and pulse width of the signal applied to the gas valve.
△ Less
Submitted 26 April, 2017;
originally announced April 2017.
-
Improvements on the Stability and Operation of a Magnetron H- Ion Source
Authors:
A. Sosa,
D. S. Bollinger,
P. R. Karns,
C. Y. Tan
Abstract:
The magnetron H- ion sources developed in the 1970s currently in operation at Fermilab provide beam to the rest of the accelerator complex. A series of modifications to these sources have been tested in a dedicated offline test stand with the aim of improving different operational issues. The solenoid type gas valve was tested as an alternative to the piezoelectric gas valve in order to avoid its…
▽ More
The magnetron H- ion sources developed in the 1970s currently in operation at Fermilab provide beam to the rest of the accelerator complex. A series of modifications to these sources have been tested in a dedicated offline test stand with the aim of improving different operational issues. The solenoid type gas valve was tested as an alternative to the piezoelectric gas valve in order to avoid its temperature dependence. A new cesium oven was designed and tested in order to avoid glass pieces that were present with the previous oven, improve thermal insulation and fine tune its temperature. A current-regulated arc modulator was developed to run the ion source at a constant arc current, providing very stable beam outputs during operations. In order to reduce beam noise, the addition of small amounts of N2 gas was explored, as well as testing different cathode shapes with increasing plasma volume. This paper summarizes the studies and modifications done in the source over the last three years with the aim of improving its stability, reliability and overall performance.
△ Less
Submitted 6 January, 2017;
originally announced January 2017.
-
An Overview of the New Test Stand for H- Ion Sources at FNAL
Authors:
A. Sosa,
D. S. Bollinger,
K. Duel,
P. Karns,
W. Pellico,
C. Y. Tan
Abstract:
A new test stand at FNAL is being constructed to carry out experiments to develop and upgrade the present magnetron-type sources of H- ions of up to 80 mA at 35 keV in the context of the Proton Improvement Plan (PIP). The aim of this plan is to provide high-power proton beams for the experiments at FNAL. The technical details of the construction and layout of this test stand are presented, along w…
▽ More
A new test stand at FNAL is being constructed to carry out experiments to develop and upgrade the present magnetron-type sources of H- ions of up to 80 mA at 35 keV in the context of the Proton Improvement Plan (PIP). The aim of this plan is to provide high-power proton beams for the experiments at FNAL. The technical details of the construction and layout of this test stand are presented, along with a prospective set of diagnostics to monitor the sources.
△ Less
Submitted 5 November, 2015;
originally announced November 2015.
-
Instrumentation Developments and Beam Studies for the Fermilab Proton Improvement Plan LINAC Upgrade and New RFQ Front-End
Authors:
Victor E. Scarpine,
Cheng-Yang Tan,
Pat R. Karns,
Daniel S. Bollinger,
Kevin L. Duel,
Nathan Eddy,
Ning Lui,
Alexei Semenov,
Raymond E. Tomlin,
William A. Pellico
Abstract:
Fermilab is develo** a Proton Improvement Plan (PIP) to increase throughput of its proton source. The plan addresses hardware modifications to increase repetition rate and improve beam loss while ensuring viable operation of the proton source through 2025. The first phase of the PIP will enable the Fermilab proton source to deliver 1.8e17 protons per hour by mid-2013. As part of this initial upg…
▽ More
Fermilab is develo** a Proton Improvement Plan (PIP) to increase throughput of its proton source. The plan addresses hardware modifications to increase repetition rate and improve beam loss while ensuring viable operation of the proton source through 2025. The first phase of the PIP will enable the Fermilab proton source to deliver 1.8e17 protons per hour by mid-2013. As part of this initial upgrade, Fermilab plans to install a new front-end consisting of dual H- ion sources and a 201 MHz pulsed RFQ. This paper will present beam studies measurements of this new front-end and discuss new beam instrumentation upgrades for the Fermilab linac.
△ Less
Submitted 29 August, 2014;
originally announced August 2014.