Showing 1–6 of 6 results for author: Karns, P

.
  1. arXiv:1805.03049  [pdf

    physics.acc-ph

    Implementation of Design Changes Towards a More Reliable, Hands-off Magnetron Ion Source

    Authors: A. Sosa, D. S. Bollinger, P. R. Karns, C. Y. Tan

    Abstract: As the main $H^{-}$ ion source for the accelerator complex, magnetron ion sources have been used at Fermilab since the 1970s. At the offline test stand, new R&D is carried out to develop and upgrade the present magnetron-type sources of $H^{-}$ ions of up to 80 mA and 35 keV beam energy in the context of the Proton Improvement Plan. The aim of this plan is to provide high-power proton beams for th… ▽ More

    Submitted 4 May, 2018; originally announced May 2018.

    Comments: 4 pp. arXiv admin note: substantial text overlap with arXiv:1701.01757

    Report number: Fermilab-Conf-17-575-AD

  2. arXiv:1704.08177  [pdf

    physics.acc-ph

    Recent Operation of the FNAL Magnetron $H^{-}$ Ion Source

    Authors: P. R. Karns, D. S. Bollinger, A. Sosa

    Abstract: This paper will detail changes in the operational paradigm of the Fermi National Accelerator Laboratory (FNAL) magnetron $H^{-}$ ion source due to upgrades in the accelerator system. Prior to November of 2012 the $H^{-}$ ions for High Energy Physics (HEP) experiments were extracted at ~18 keV vertically downward into a 90 degree bending magnet and accelerated through a Cockcroft-Walton acceleratin… ▽ More

    Submitted 26 April, 2017; originally announced April 2017.

    Comments: 8 pp

    Report number: Fermilab-Conf-16-351-AD

  3. arXiv:1704.08170  [pdf

    physics.acc-ph

    Performance Characterization of a Solenoid-type Gas Valve for the $H^{-}$ Magnetron Source at FNAL

    Authors: A. Sosa, D. S. Bollinger, P. R. Karns

    Abstract: The magnetron-style $H^{-}$ ion sources currently in operation at Fermilab use piezoelectric gas valves to function. This kind of gas valve is sensitive to small changes in ambient temperature, which affect the stability and performance of the ion source. This motivates the need to find an alternative way of feeding H2 gas into the source. A solenoid-type gas valve has been characterized in a dedi… ▽ More

    Submitted 26 April, 2017; originally announced April 2017.

    Comments: 4 pp. arXiv admin note: text overlap with arXiv:1701.01757

    Report number: Fermilab-Conf-16-348-AD

  4. Improvements on the Stability and Operation of a Magnetron H- Ion Source

    Authors: A. Sosa, D. S. Bollinger, P. R. Karns, C. Y. Tan

    Abstract: The magnetron H- ion sources developed in the 1970s currently in operation at Fermilab provide beam to the rest of the accelerator complex. A series of modifications to these sources have been tested in a dedicated offline test stand with the aim of improving different operational issues. The solenoid type gas valve was tested as an alternative to the piezoelectric gas valve in order to avoid its… ▽ More

    Submitted 6 January, 2017; originally announced January 2017.

    Comments: 8 pages, 19 figures

  5. arXiv:1511.01924  [pdf

    physics.acc-ph

    An Overview of the New Test Stand for H- Ion Sources at FNAL

    Authors: A. Sosa, D. S. Bollinger, K. Duel, P. Karns, W. Pellico, C. Y. Tan

    Abstract: A new test stand at FNAL is being constructed to carry out experiments to develop and upgrade the present magnetron-type sources of H- ions of up to 80 mA at 35 keV in the context of the Proton Improvement Plan (PIP). The aim of this plan is to provide high-power proton beams for the experiments at FNAL. The technical details of the construction and layout of this test stand are presented, along w… ▽ More

    Submitted 5 November, 2015; originally announced November 2015.

    Comments: 3 pp. Contributed paper, published as part of the Proceedings of the 16th International Conference on Ion Sources (ICIS 2015), New York City, NY, August 2015

    Report number: FERMILAB-CONF-15-233-AD

  6. arXiv:1408.7108  [pdf

    physics.acc-ph

    Instrumentation Developments and Beam Studies for the Fermilab Proton Improvement Plan LINAC Upgrade and New RFQ Front-End

    Authors: Victor E. Scarpine, Cheng-Yang Tan, Pat R. Karns, Daniel S. Bollinger, Kevin L. Duel, Nathan Eddy, Ning Lui, Alexei Semenov, Raymond E. Tomlin, William A. Pellico

    Abstract: Fermilab is develo** a Proton Improvement Plan (PIP) to increase throughput of its proton source. The plan addresses hardware modifications to increase repetition rate and improve beam loss while ensuring viable operation of the proton source through 2025. The first phase of the PIP will enable the Fermilab proton source to deliver 1.8e17 protons per hour by mid-2013. As part of this initial upg… ▽ More

    Submitted 29 August, 2014; originally announced August 2014.

    Comments: 5 p

    Report number: FERMILAB-CONF-12-575-AD