-
An Improved Method of Total Variation Superiorization Applied to Reconstruction in Proton Computed Tomography
Authors:
Blake Schultze,
Yair Censor,
Paniz Karbasi,
Keith E. Schubert,
Reinhard W. Schulte
Abstract:
Previous work showed that total variation superiorization (TVS) improves reconstructed image quality in proton computed tomography (pCT). The structure of the TVS algorithm has evolved since then and this work investigated if this new algorithmic structure provides additional benefits to pCT image quality. Structural and parametric changes introduced to the original TVS algorithm included: (1) inc…
▽ More
Previous work showed that total variation superiorization (TVS) improves reconstructed image quality in proton computed tomography (pCT). The structure of the TVS algorithm has evolved since then and this work investigated if this new algorithmic structure provides additional benefits to pCT image quality. Structural and parametric changes introduced to the original TVS algorithm included: (1) inclusion or exclusion of TV reduction requirement, (2) a variable number, $N$, of TV perturbation steps per feasibility-seeking iteration, and (3) introduction of a perturbation kernel $0<α<1$. The structural change of excluding the TV reduction requirement check tended to have a beneficial effect for $3\le N\le 6$ and allows full parallelization of the TVS algorithm. Repeated perturbations per feasibility-seeking iterations reduced total variation (TV) and material dependent standard deviations for $3\le N\le 6$. The perturbation kernel $α$, equivalent to $α=0.5$ in the original TVS algorithm, reduced TV and standard deviations as $α$ was increased beyond $α=0.5$, but negatively impacted reconstructed relative stop** power (RSP) values for $α>0.75$. The reductions in TV and standard deviations allowed feasibility-seeking with a larger relaxation parameter $λ$ than previously used, without the corresponding increases in standard deviations experienced with the original TVS algorithm. This work demonstrates that the modifications related to the evolution of the original TVS algorithm provide benefits in terms of both pCT image quality and computational efficiency for appropriately chosen parameter values.
△ Less
Submitted 17 January, 2019; v1 submitted 3 March, 2018;
originally announced March 2018.
-
A Highly Accelerated Parallel Multi-GPU based Reconstruction Algorithm for Generating Accurate Relative Stop** Powers
Authors:
Paniz Karbasi,
Ritchie Cai,
Blake Schultze,
Hanh Nguyen,
Jones Reed,
Patrick Hall,
Valentina Giacometti,
Vladimir Bashkirov,
Robert Johnson,
Nick Karonis,
Jeffrey Olafsen,
Caesar Ordonez,
Keith E. Schubert,
Reinhard W. Schulte
Abstract:
Low-dose Proton Computed Tomography (pCT) is an evolving imaging modality that is used in proton therapy planning which addresses the range uncertainty problem. The goal of pCT is generating a 3D map of Relative Stop** Power (RSP) measurements with high accuracy within clinically required time frames. Generating accurate RSP values within the shortest amount of time is considered a key goal when…
▽ More
Low-dose Proton Computed Tomography (pCT) is an evolving imaging modality that is used in proton therapy planning which addresses the range uncertainty problem. The goal of pCT is generating a 3D map of Relative Stop** Power (RSP) measurements with high accuracy within clinically required time frames. Generating accurate RSP values within the shortest amount of time is considered a key goal when develo** a pCT software. The existing pCT softwares have successfully met this time frame and even succeeded this time goal, but requiring clusters with hundreds of processors.
This paper describes a novel reconstruction technique using two Graphics Processing Unit (GPU) cores, such as is available on a single Nvidia P100. The proposed reconstruction technique is tested on both simulated and experimental datasets and on two different systems namely Nvidia K40 and P100 GPUs from IBM and Cray. The experimental results demonstrate that our proposed reconstruction method meets both the timing and accuracy with the benefit of having reasonable cost, and efficient use of power.
△ Less
Submitted 3 February, 2018;
originally announced February 2018.
-
Results from a Prototype Proton-CT Head Scanner
Authors:
R. P. Johnson,
V. A. Bashkirov,
G. Coutrakon,
V. Giacometti,
P. Karbasi,
N. T. Karonis,
C. E. Ordoñez,
M. Pankuch,
H. F. -W. Sadrozinski,
K. E. Schubert,
R. W. Schulte
Abstract:
We are exploring low-dose proton radiography and computed tomography (pCT) as techniques to improve the accuracy of proton treatment planning and to provide artifact-free images for verification and adaptive therapy at the time of treatment. Here we report on comprehensive beam test results with our prototype pCT head scanner. The detector system and data acquisition attain a sustained rate of mor…
▽ More
We are exploring low-dose proton radiography and computed tomography (pCT) as techniques to improve the accuracy of proton treatment planning and to provide artifact-free images for verification and adaptive therapy at the time of treatment. Here we report on comprehensive beam test results with our prototype pCT head scanner. The detector system and data acquisition attain a sustained rate of more than a million protons individually measured per second, allowing a full CT scan to be completed in six minutes or less of beam time. In order to assess the performance of the scanner for proton radiography as well as computed tomography, we have performed numerous scans of phantoms at the Northwestern Medicine Chicago Proton Center including a custom phantom designed to assess the spatial resolution, a phantom to assess the measurement of relative stop** power, and a dosimetry phantom. Some images, performance, and dosimetry results from those phantom scans are presented together with a description of the instrument, the data acquisition system, and the calibration methods.
△ Less
Submitted 5 July, 2017;
originally announced July 2017.