-
The large scale polarization explorer (LSPE) for CMB measurements: performance forecast
Authors:
The LSPE collaboration,
G. Addamo,
P. A. R. Ade,
C. Baccigalupi,
A. M. Baldini,
P. M. Battaglia,
E. S. Battistelli,
A. Baù,
P. de Bernardis,
M. Bersanelli,
M. Biasotti,
A. Boscaleri,
B. Caccianiga,
S. Caprioli,
F. Cavaliere,
F. Cei,
K. A. Cleary,
F. Columbro,
G. Coppi,
A. Coppolecchia,
F. Cuttaia,
G. D'Alessandro,
G. De Gasperis,
M. De Petris,
V. Fafone
, et al. (80 additional authors not shown)
Abstract:
[Abridged] The measurement of the polarization of the Cosmic Microwave Background radiation is one of the current frontiers in cosmology. In particular, the detection of the primordial B-modes, could reveal the presence of gravitational waves in the early Universe. The detection of such component is at the moment the most promising technique to probe the inflationary theory describing the very ear…
▽ More
[Abridged] The measurement of the polarization of the Cosmic Microwave Background radiation is one of the current frontiers in cosmology. In particular, the detection of the primordial B-modes, could reveal the presence of gravitational waves in the early Universe. The detection of such component is at the moment the most promising technique to probe the inflationary theory describing the very early evolution of the Universe. We present the updated performance forecast of the Large Scale Polarization Explorer (LSPE), a program dedicated to the measurement of the CMB polarization. LSPE is composed of two instruments: Strip, a radiometer-based telescope on the ground in Tenerife, and SWIPE (Short-Wavelength Instrument for the Polarization Explorer) a bolometer-based instrument designed to fly on a winter arctic stratospheric long-duration balloon. The program is among the few dedicated to observation of the Northern Hemisphere, while most of the international effort is focused into ground-based observation in the Southern Hemisphere. Measurements are currently scheduled in Winter 2021/22 for SWIPE, with a flight duration up to 15 days, and in Summer 2021 with two years observations for Strip. We describe the main features of the two instruments, identifying the most critical aspects of the design, in terms of impact into performance forecast. We estimate the expected sensitivity of each instrument and propagate their combined observing power to the sensitivity to cosmological parameters, including the effect of scanning strategy, component separation, residual foregrounds and partial sky coverage. We also set requirements on the control of the most critical systematic effects and describe techniques to mitigate their impact. LSPE can reach a sensitivity in tensor-to-scalar ratio of $σ_r<0.01$, and improve constrains on other cosmological parameters.
△ Less
Submitted 9 August, 2021; v1 submitted 25 August, 2020;
originally announced August 2020.
-
Progress report on the Large Scale Polarization Explorer
Authors:
L. Lamagna,
G. Addamo,
P. A. R. Ade,
C. Baccigalupi,
A. M. Baldini,
P. M. Battaglia,
E. Battistelli,
A. Baù,
M. Bersanelli,
M. Biasotti,
C. Boragno,
A. Boscaleri,
B. Caccianiga,
S. Caprioli,
F. Cavaliere,
F. Cei,
K. A. Cleary,
F. Columbro,
G. Coppi,
A. Coppolecchia,
D. Corsini,
F. Cuttaia,
G. D'Alessandro,
P. de Bernardis,
G. De Gasperis
, et al. (74 additional authors not shown)
Abstract:
The Large Scale Polarization Explorer (LSPE) is a cosmology program for the measurement of large scale curl-like features (B-modes) in the polarization of the Cosmic Microwave Background. Its goal is to constrain the background of inflationary gravity waves traveling through the universe at the time of matter-radiation decoupling. The two instruments of LSPE are meant to synergically operate by co…
▽ More
The Large Scale Polarization Explorer (LSPE) is a cosmology program for the measurement of large scale curl-like features (B-modes) in the polarization of the Cosmic Microwave Background. Its goal is to constrain the background of inflationary gravity waves traveling through the universe at the time of matter-radiation decoupling. The two instruments of LSPE are meant to synergically operate by covering a large portion of the northern microwave sky. LSPE/STRIP is a coherent array of receivers planned to be operated from the Teide Observatory in Tenerife, for the control and characterization of the low-frequency polarized signals of galactic origin; LSPE/SWIPE is a balloon-borne bolometric polarimeter based on 330 large throughput multi-moded detectors, designed to measure the CMB polarization at 150 GHz and to monitor the polarized emission by galactic dust above 200 GHz. The combined performance and the expected level of systematics mitigation will allow LSPE to constrain primordial B-modes down to a tensor/scalar ratio of $10^{-2}$. We here report the status of the STRIP pre-commissioning phase and the progress in the characterization of the key subsystems of the SWIPE payload (namely the cryogenic polarization modulation unit and the multi-moded TES pixels) prior to receiver integration.
△ Less
Submitted 5 May, 2020; v1 submitted 3 May, 2020;
originally announced May 2020.
-
An Ammonia Spectral Map of the L1495-B218 Filaments in the Taurus Molecular Cloud: II CCS & HC$_7$N Chemistry and Three Modes of Star Formation in the Filaments
Authors:
Young Min Seo,
Liton Majumdar,
Paul F. Goldsmith,
Yancy L. Shirley,
Karen Willacy,
Derek Ward-Thompson,
Rachel Friesen,
David Frayer,
Sarah E. Church,
Dongwoo Chung,
Kieran Cleary,
Nichol Cunningham,
Kiruthika Devaraj,
Dennis Egan,
Todd Gaier,
Rohit Gawande,
Joshua O. Gundersen,
Andrew I. Harris,
Pekka Kangaslahti,
Anthony C. S. Readhead,
Lorene Samoska,
Matthew Sieth,
Michael Stennes,
Patricia Voll,
Steve White
Abstract:
We present deep CCS and HC$_7$N observations of the L1495-B218 filaments in the Taurus molecular cloud obtained using the K-band focal plane array on the 100m Green Bank Telescope. We observed the L1495-B218 filaments in CCS $J_N$ = 2$_1$$-$1$_0$ and HC$_7$N $J$ = 21$-$20 with a spectral resolution of 0.038 km s$^{-1}$ and an angular resolution of 31$''$. We observed strong CCS emission in both ev…
▽ More
We present deep CCS and HC$_7$N observations of the L1495-B218 filaments in the Taurus molecular cloud obtained using the K-band focal plane array on the 100m Green Bank Telescope. We observed the L1495-B218 filaments in CCS $J_N$ = 2$_1$$-$1$_0$ and HC$_7$N $J$ = 21$-$20 with a spectral resolution of 0.038 km s$^{-1}$ and an angular resolution of 31$''$. We observed strong CCS emission in both evolved and young regions and weak emission in two evolved regions. HC$_7$N emission is observed only in L1495A-N and L1521D. We find that CCS and HC$_7$N intensity peaks do not coincide with NH$_3$ or dust continuum intensity peaks. We also find that the fractional abundance of CCS does not show a clear correlation with the dynamical evolutionary stage of dense cores. Our findings and chemical modeling indicate that the fractional abundances of CCS and HC$_7$N are sensitive to the initial gas-phase C/O ratio, and they are good tracers of young condensed gas only when the initial C/O is close to solar value. Kinematic analysis using multiple lines including NH$_3$, HC$_7$N, CCS, CO, HCN, \& HCO$^+$ suggests that there may be three different star formation modes in the L1495-B218 filaments. At the hub of the filaments, L1495A/B7N has formed a stellar cluster with large-scale inward flows (fast mode), while L1521D, a core embedded in a filament, is slowly contracting due to its self-gravity (slow mode). There is also one isolated core that appears to be marginally stable and may undergo quasi-static evolution (isolated mode).
△ Less
Submitted 14 December, 2018;
originally announced December 2018.
-
The STRIP instrument of the Large Scale Polarization Explorer: microwave eyes to map the Galactic polarized foregrounds
Authors:
C. Franceschet,
S. Realini,
A. Mennella,
G. Addamo,
A. Baù,
P. M. Battaglia,
M. Bersanelli,
B. Caccianiga,
S. Caprioli,
F. Cavaliere,
K. A. Cleary,
F. Cuttaia,
F. Del Torto,
V. Fafone,
Z. Farooqui,
R. T. Génova Santos,
T. C. Gaier,
M. Gervasi,
T. Ghigna,
F. Incardona,
S. Iovenitti,
M. Jones,
P. Kangaslahti,
R. Mainini,
D. Maino
, et al. (26 additional authors not shown)
Abstract:
In this paper we discuss the latest developments of the STRIP instrument of the "Large Scale Polarization Explorer" (LSPE) experiment. LSPE is a novel project that combines ground-based (STRIP) and balloon-borne (SWIPE) polarization measurements of the microwave sky on large angular scales to attempt a detection of the "B-modes" of the Cosmic Microwave Background polarization. STRIP will observe a…
▽ More
In this paper we discuss the latest developments of the STRIP instrument of the "Large Scale Polarization Explorer" (LSPE) experiment. LSPE is a novel project that combines ground-based (STRIP) and balloon-borne (SWIPE) polarization measurements of the microwave sky on large angular scales to attempt a detection of the "B-modes" of the Cosmic Microwave Background polarization. STRIP will observe approximately 25% of the Northern sky from the "Observatorio del Teide" in Tenerife, using an array of forty-nine coherent polarimeters at 43 GHz, coupled to a 1.5 m fully rotating crossed-Dragone telescope. A second frequency channel with six-elements at 95 GHz will be exploited as an atmospheric monitor. At present, most of the hardware of the STRIP instrument has been developed and tested at sub-system level. System-level characterization, starting in July 2018, will lead STRIP to be shipped and installed at the observation site within the end of the year. The on-site verification and calibration of the whole instrument will prepare STRIP for a 2-years campaign for the observation of the CMB polarization.
△ Less
Submitted 10 December, 2018;
originally announced December 2018.
-
Planck 2013 results. V. LFI calibration
Authors:
Planck Collaboration,
N. Aghanim,
C. Armitage-Caplan,
M. Arnaud,
M. Ashdown,
F. Atrio-Barandela,
J. Aumont,
C. Baccigalupi,
A. J. Banday,
R. B. Barreiro,
E. Battaner,
K. Benabed,
A. Benoît,
A. Benoit-Lévy,
J. -P. Bernard,
M. Bersanelli,
P. Bielewicz,
J. Bobin,
J. J. Bock,
A. Bonaldi,
L. Bonavera,
J. R. Bond,
J. Borrill,
F. R. Bouchet,
M. Bridges
, et al. (195 additional authors not shown)
Abstract:
We discuss the methods employed to photometrically calibrate the data acquired by the Low Frequency Instrument on Planck. Our calibration is based on a combination of the Orbital Dipole plus the Solar Dipole, caused respectively by the motion of the Planck spacecraft with respect to the Sun and by motion of the Solar System with respect to the CMB rest frame. The latter provides a signal of a few…
▽ More
We discuss the methods employed to photometrically calibrate the data acquired by the Low Frequency Instrument on Planck. Our calibration is based on a combination of the Orbital Dipole plus the Solar Dipole, caused respectively by the motion of the Planck spacecraft with respect to the Sun and by motion of the Solar System with respect to the CMB rest frame. The latter provides a signal of a few mK with the same spectrum as the CMB anisotropies and is visible throughout the mission. In this data release we rely on the characterization of the Solar Dipole as measured by WMAP. We also present preliminary results (at 44GHz only) on the study of the Orbital Dipole, which agree with the WMAP value of the Solar System speed within our uncertainties. We compute the calibration constant for each radiometer roughly once per hour, in order to keep track of changes in the detectors' gain. Since non-idealities in the optical response of the beams proved to be important, we implemented a fast convolution algorithm which considers the full beam response in estimating the signal generated by the dipole. Moreover, in order to further reduce the impact of residual systematics due to sidelobes, we estimated time variations in the calibration constant of the 30GHz radiometers (the ones with the largest sidelobes) using the signal of a reference load. We have estimated the calibration accuracy in two ways: we have run a set of simulations to assess the impact of statistical errors and systematic effects in the instrument and in the calibration procedure, and we have performed a number of consistency checks on the data and on the brightness temperature of Jupiter. Calibration errors for this data release are expected to be about 0.6% at 44 and 70 GHz, and 0.8% at 30 GHz. (Abriged.)
△ Less
Submitted 20 August, 2014; v1 submitted 20 March, 2013;
originally announced March 2013.
-
Planck 2013 results. IV. Low Frequency Instrument beams and window functions
Authors:
Planck Collaboration,
N. Aghanim,
C. Armitage-Caplan,
M. Arnaud,
M. Ashdown,
F. Atrio-Barandela,
J. Aumont,
C. Baccigalupi,
A. J. Banday,
R. B. Barreiro,
E. Battaner,
K. Benabed,
A. Benoît,
A. Benoit-Lévy,
J. -P. Bernard,
M. Bersanelli,
P. Bielewicz,
J. Bobin,
J. J. Bock,
A. Bonaldi,
J. R. Bond,
J. Borrill,
F. R. Bouchet,
M. Bridges,
M. Bucher
, et al. (185 additional authors not shown)
Abstract:
This paper presents the characterization of the in-flight beams, the beam window functions and the associated uncertainties for the Planck Low Frequency Instrument (LFI). Knowledge of the beam profiles is necessary for determining the transfer function to go from the observed to the actual sky anisotropy power spectrum. The main beam distortions affect the beam window function, complicating the re…
▽ More
This paper presents the characterization of the in-flight beams, the beam window functions and the associated uncertainties for the Planck Low Frequency Instrument (LFI). Knowledge of the beam profiles is necessary for determining the transfer function to go from the observed to the actual sky anisotropy power spectrum. The main beam distortions affect the beam window function, complicating the reconstruction of the anisotropy power spectrum at high multipoles, whereas the sidelobes affect the low and intermediate multipoles. The in-flight assessment of the LFI main beams relies on the measurements performed during Jupiter observations. By stacking the data from multiple Jupiter transits, the main beam profiles are measured down to -20 dB at 30 and 44 GHz, and down to -25 dB at 70 GHz. The main beam solid angles are determined to better than 0.2% at each LFI frequency band. The Planck pre-launch optical model is conveniently tuned to characterize the main beams independently of any noise effects. This approach provides an optical model whose beams fully reproduce the measurements in the main beam region, but also allows a description of the beams at power levels lower than can be achieved by the Jupiter measurements themselves. The agreement between the simulated beams and the measured beams is better than 1% at each LFI frequency band. The simulated beams are used for the computation of the window functions for the effective beams. The error budget for the window functions is estimated from both main beam and sidelobe contributions, and accounts for the radiometer bandshapes. The total uncertainties in the effective beam window functions are: 2% and 1.2% at 30 and 44 GHz, respectively (at $\ell \approx 600$), and 0.7% at 70 GHz (at $\ell \approx 1000$).
△ Less
Submitted 28 February, 2014; v1 submitted 20 March, 2013;
originally announced March 2013.
-
Planck 2013 results. III. LFI systematic uncertainties
Authors:
Planck Collaboration,
N. Aghanim,
C. Armitage-Caplan,
M. Arnaud,
M. Ashdown,
F. Atrio-Barandela,
J. Aumont,
C. Baccigalupi,
A. J. Banday,
R. B. Barreiro,
E. Battaner,
K. Benabed,
A. Benoît,
A. Benoit-Lévy,
J. -P. Bernard,
M. Bersanelli,
P. Bielewicz,
J. Bobin,
J. J. Bock,
A. Bonaldi,
L. Bonavera,
J. R. Bond,
J. Borrill,
F. R. Bouchet,
M. Bridges
, et al. (195 additional authors not shown)
Abstract:
We present the current estimate of instrumental and systematic effect uncertainties for the Planck-Low Frequency Instrument relevant to the first release of the Planck cosmological results. We give an overview of the main effects and of the tools and methods applied to assess residuals in maps and power spectra. We also present an overall budget of known systematic effect uncertainties, which are…
▽ More
We present the current estimate of instrumental and systematic effect uncertainties for the Planck-Low Frequency Instrument relevant to the first release of the Planck cosmological results. We give an overview of the main effects and of the tools and methods applied to assess residuals in maps and power spectra. We also present an overall budget of known systematic effect uncertainties, which are dominated sidelobe straylight pick-up and imperfect calibration. However, even these two effects are at least two orders of magnitude weaker than the cosmic microwave background (CMB) fluctuations as measured in terms of the angular temperature power spectrum. A residual signal above the noise level is present in the multipole range $\ell<20$, most notably at 30 GHz, and is likely caused by residual Galactic straylight contamination. Current analysis aims to further reduce the level of spurious signals in the data and to improve the systematic effects modelling, in particular with respect to straylight and calibration uncertainties.
△ Less
Submitted 27 March, 2014; v1 submitted 20 March, 2013;
originally announced March 2013.
-
Planck 2013 results. II. Low Frequency Instrument data processing
Authors:
Planck Collaboration,
N. Aghanim,
C. Armitage-Caplan,
M. Arnaud,
M. Ashdown,
F. Atrio-Barandela,
J. Aumont,
C. Baccigalupi,
A. J. Banday,
R. B. Barreiro,
E. Battaner,
K. Benabed,
A. Benoît,
A. Benoit-Lévy,
J. -P. Bernard,
M. Bersanelli,
P. Bielewicz,
J. Bobin,
J. J. Bock,
A. Bonaldi,
L. Bonavera,
J. R. Bond,
J. Borrill,
F. R. Bouchet,
M. Bridges
, et al. (207 additional authors not shown)
Abstract:
We describe the data processing pipeline of the Planck Low Frequency Instrument (LFI) data processing centre (DPC) to create and characterize full-sky maps based on the first 15.5 months of operations at 30, 44 and 70 GHz. In particular, we discuss the various steps involved in reducing the data, starting from telemetry packets through to the production of cleaned, calibrated timelines and calibra…
▽ More
We describe the data processing pipeline of the Planck Low Frequency Instrument (LFI) data processing centre (DPC) to create and characterize full-sky maps based on the first 15.5 months of operations at 30, 44 and 70 GHz. In particular, we discuss the various steps involved in reducing the data, starting from telemetry packets through to the production of cleaned, calibrated timelines and calibrated frequency maps. Data are continuously calibrated using the modulation induced on the mean temperature of the cosmic microwave background radiation by the proper motion of the spacecraft. Sky signals other than the dipole are removed by an iterative procedure based on simultaneous fitting of calibration parameters and sky maps. Noise properties are estimated from time-ordered data after the sky signal has been removed, using a generalized least square map-making algorithm. A destri** code (Madam) is employed to combine radiometric data and pointing information into sky maps, minimizing the variance of correlated noise. Noise covariance matrices, required to compute statistical uncertainties on LFI and Planck products, are also produced. Main beams are estimated down to the -20 dB level using Jupiter transits, which are also used for the geometrical calibration of the focal plane.
△ Less
Submitted 2 February, 2014; v1 submitted 20 March, 2013;
originally announced March 2013.
-
Planck 2013 results. I. Overview of products and scientific results
Authors:
Planck Collaboration,
P. A. R. Ade,
N. Aghanim,
M. I. R. Alves,
C. Armitage-Caplan,
M. Arnaud,
M. Ashdown,
F. Atrio-Barandela,
J. Aumont,
H. Aussel,
C. Baccigalupi,
A. J. Banday,
R. B. Barreiro,
R. Barrena,
M. Bartelmann,
J. G. Bartlett,
N. Bartolo,
S. Basak,
E. Battaner,
R. Battye,
K. Benabed,
A. Benoît,
A. Benoit-Lévy,
J. -P. Bernard,
M. Bersanelli
, et al. (376 additional authors not shown)
Abstract:
The ESA's Planck satellite, dedicated to studying the early Universe and its subsequent evolution, was launched 14 May 2009 and has been scanning the microwave and submillimetre sky continuously since 12 August 2009. This paper gives an overview of the mission and its performance, the processing, analysis, and characteristics of the data, the scientific results, and the science data products and p…
▽ More
The ESA's Planck satellite, dedicated to studying the early Universe and its subsequent evolution, was launched 14 May 2009 and has been scanning the microwave and submillimetre sky continuously since 12 August 2009. This paper gives an overview of the mission and its performance, the processing, analysis, and characteristics of the data, the scientific results, and the science data products and papers in the release. The science products include maps of the CMB and diffuse extragalactic foregrounds, a catalogue of compact Galactic and extragalactic sources, and a list of sources detected through the SZ effect. The likelihood code used to assess cosmological models against the Planck data and a lensing likelihood are described. Scientific results include robust support for the standard six-parameter LCDM model of cosmology and improved measurements of its parameters, including a highly significant deviation from scale invariance of the primordial power spectrum. The Planck values for these parameters and others derived from them are significantly different from those previously determined. Several large-scale anomalies in the temperature distribution of the CMB, first detected by WMAP, are confirmed with higher confidence. Planck sets new limits on the number and mass of neutrinos, and has measured gravitational lensing of CMB anisotropies at greater than 25 sigma. Planck finds no evidence for non-Gaussianity in the CMB. Planck's results agree well with results from the measurements of baryon acoustic oscillations. Planck finds a lower Hubble constant than found in some more local measures. Some tension is also present between the amplitude of matter fluctuations derived from CMB data and that derived from SZ data. The Planck and WMAP power spectra are offset from each other by an average level of about 2% around the first acoustic peak.
△ Less
Submitted 5 June, 2014; v1 submitted 20 March, 2013;
originally announced March 2013.
-
A coherent polarimeter array for the Large Scale Polarization Explorer balloon experiment
Authors:
M. Bersanelli,
A. Mennella,
G. Morgante,
M. Zannoni,
G. Addamo,
A. Baschirotto,
P. Battaglia,
A. Baù,
B. Cappellini,
F. Cavaliere,
F. Cuttaia,
F. Del Torto,
S. Donzelli,
Z. Farooqui,
M. Frailis,
C. Franceschet,
E. Franceschi,
T. Gaier,
S. Galeotta,
M. Gervasi,
A. Gregorio,
P. Kangaslahti,
N. Krachmalnicoff,
C. Lawrence,
G. Maggio
, et al. (21 additional authors not shown)
Abstract:
We discuss the design and expected performance of STRIP (STRatospheric Italian Polarimeter), an array of coherent receivers designed to fly on board the LSPE (Large Scale Polarization Explorer) balloon experiment. The STRIP focal plane array comprises 49 elements in Q band and 7 elements in W-band using cryogenic HEMT low noise amplifiers and high performance waveguide components. In operation, th…
▽ More
We discuss the design and expected performance of STRIP (STRatospheric Italian Polarimeter), an array of coherent receivers designed to fly on board the LSPE (Large Scale Polarization Explorer) balloon experiment. The STRIP focal plane array comprises 49 elements in Q band and 7 elements in W-band using cryogenic HEMT low noise amplifiers and high performance waveguide components. In operation, the array will be cooled to 20 K and placed in the focal plane of a $\sim 0.6$ meter telescope providing an angular resolution of $\sim1.5$ degrees. The LSPE experiment aims at large scale, high sensitivity measurements of CMB polarization, with multi-frequency deep measurements to optimize component separation. The STRIP Q-band channel is crucial to accurately measure and remove the synchrotron polarized component, while the W-band channel, together with a bolometric channel at the same frequency, provides a crucial cross-check for systematic effects.
△ Less
Submitted 1 August, 2012;
originally announced August 2012.
-
The QUIET Instrument
Authors:
QUIET Collaboration,
C. Bischoff,
A. Brizius,
I. Buder,
Y. Chinone,
K. Cleary,
R. N. Dumoulin,
A. Kusaka,
R. Monsalve,
S. K. Naess,
L. B. Newburgh,
G. Nixon,
R. Reeves,
K. M. Smith,
K. Vanderlinde,
I. K. Wehus,
M. Bogdan,
R. Bustos,
S. E. Church,
R. Davis,
C. Dickinson,
H. K. Eriksen,
T. Gaier,
J. O. Gundersen,
M. Hasegawa
, et al. (30 additional authors not shown)
Abstract:
The Q/U Imaging ExperimenT (QUIET) is designed to measure polarization in the Cosmic Microwave Background, targeting the imprint of inflationary gravitational waves at large angular scales (~ 1 degree). Between 2008 October and 2010 December, two independent receiver arrays were deployed sequentially on a 1.4 m side-fed Dragonian telescope. The polarimeters which form the focal planes use a highly…
▽ More
The Q/U Imaging ExperimenT (QUIET) is designed to measure polarization in the Cosmic Microwave Background, targeting the imprint of inflationary gravitational waves at large angular scales (~ 1 degree). Between 2008 October and 2010 December, two independent receiver arrays were deployed sequentially on a 1.4 m side-fed Dragonian telescope. The polarimeters which form the focal planes use a highly compact design based on High Electron Mobility Transistors (HEMTs) that provides simultaneous measurements of the Stokes parameters Q, U, and I in a single module. The 17-element Q-band polarimeter array, with a central frequency of 43.1 GHz, has the best sensitivity (69 uK sqrt(s)) and the lowest instrumental systematic errors ever achieved in this band, contributing to the tensor-to-scalar ratio at r < 0.1. The 84-element W-band polarimeter array has a sensitivity of 87 uK sqrt(s) at a central frequency of 94.5 GHz. It has the lowest systematic errors to date, contributing at r < 0.01. The two arrays together cover multipoles in the range l= 25-975. These are the largest HEMT-based arrays deployed to date. This article describes the design, calibration, performance of, and sources of systematic error for the instrument.
△ Less
Submitted 31 July, 2012; v1 submitted 23 July, 2012;
originally announced July 2012.
-
Second Season QUIET Observations: Measurements of the CMB Polarization Power Spectrum at 95 GHz
Authors:
QUIET Collaboration,
D. Araujo,
C. Bischoff,
A. Brizius,
I. Buder,
Y. Chinone,
K. Cleary,
R. N. Dumoulin,
A. Kusaka,
R. Monsalve,
S. K. Næss,
L. B. Newburgh,
R. Reeves,
I. K. Wehus,
J. T. L. Zwart,
L. Bronfman,
R. Bustos,
S. E. Church,
C. Dickinson,
H. K. Eriksen,
T. Gaier,
J. O. Gundersen,
M. Hasegawa,
M. Hazumi,
K. M. Huffenberger
, et al. (26 additional authors not shown)
Abstract:
The Q/U Imaging ExperimenT (QUIET) has observed the cosmic microwave background (CMB) at 43 and 95GHz. The 43-GHz results have been published in QUIET Collaboration et al. (2011), and here we report the measurement of CMB polarization power spectra using the 95-GHz data. This data set comprises 5337 hours of observations recorded by an array of 84 polarized coherent receivers with a total array se…
▽ More
The Q/U Imaging ExperimenT (QUIET) has observed the cosmic microwave background (CMB) at 43 and 95GHz. The 43-GHz results have been published in QUIET Collaboration et al. (2011), and here we report the measurement of CMB polarization power spectra using the 95-GHz data. This data set comprises 5337 hours of observations recorded by an array of 84 polarized coherent receivers with a total array sensitivity of 87 uK sqrt(s). Four low-foreground fields were observed, covering a total of ~1000 square degrees with an effective angular resolution of 12.8', allowing for constraints on primordial gravitational waves and high-signal-to-noise measurements of the E-modes across three acoustic peaks. The data reduction was performed using two independent analysis pipelines, one based on a pseudo-Cl (PCL) cross-correlation approach, and the other on a maximum-likelihood (ML) approach. All data selection criteria and filters were modified until a predefined set of null tests had been satisfied before inspecting any non-null power spectrum. The results derived by the two pipelines are in good agreement. We characterize the EE, EB and BB power spectra between l=25 and 975 and find that the EE spectrum is consistent with LCDM, while the BB power spectrum is consistent with zero. Based on these measurements, we constrain the tensor-to-scalar ratio to r=1.1+0.9-0.8 (r<2.8 at 95% C.L.) as derived by the ML pipeline, and r=1.2+0.9-0.8 (r<2.7 at 95% C.L.) as derived by the PCL pipeline. In one of the fields, we find a correlation with the dust component of the Planck Sky Model, though the corresponding excess power is small compared to statistical errors. Finally, we derive limits on all known systematic errors, and demonstrate that these correspond to a tensor-to-scalar ratio smaller than r=0.01, the lowest level yet reported in the literature.
△ Less
Submitted 30 January, 2013; v1 submitted 20 July, 2012;
originally announced July 2012.
-
Technology developments for a scalable heterodyne MMIC array at W-band
Authors:
Matthew Sieth,
Sarah Church,
Judy M. Lau,
Patricia Voll,
Todd Gaier,
Pekka Kangaslahti,
Lorene Samoska,
Mary Soria,
Kieran Cleary,
Rohit Gawande,
Anthony C. S. Readhead,
Rodrigo Reeves,
Andrew Harris,
Jeffrey Neilson,
Sami Tantawi,
Dan Van Winkle
Abstract:
We report on the development of W-band (75-110 GHz) heterodyne receiver technology for large-format astronomical arrays. The receiver system is designed to be both mass-producible, so that the designs could be scaled to thousands of receiver elements, and modular. Most of the receiver function- ality is integrated into compact Monolithic Microwave Integrated Circuit (MMIC) amplifier-based multichi…
▽ More
We report on the development of W-band (75-110 GHz) heterodyne receiver technology for large-format astronomical arrays. The receiver system is designed to be both mass-producible, so that the designs could be scaled to thousands of receiver elements, and modular. Most of the receiver function- ality is integrated into compact Monolithic Microwave Integrated Circuit (MMIC) amplifier-based multichip modules. The MMIC modules include a chain of InP MMIC low-noise amplifiers, coupled-line bandpass filters and sub-harmonic Schottky diode mixers. The receiver signals will be routed to and from the MMIC modules on a multilayer high frequency laminate, which includes splitters, amplifiers, and frequency doublers. A prototype MMIC module has exhibited a band-averaged noise temperature of 41 K from 82-100 GHz and a gain of 29 dB at 15 K, which is the state- of-the-art for heterodyne multi-chip modules.
△ Less
Submitted 13 April, 2012;
originally announced April 2012.
-
Planck early results. III. First assessment of the Low Frequency Instrument in-flight performance
Authors:
A. Mennella,
M. Bersanelli,
R. C. Butler,
A. Curto,
F. Cuttaia,
R. J. Davis,
J. Dick,
M. Frailis,
S. Galeotta,
A. Gregorio,
H. Kurki-Suonio,
C. R. Lawrence,
S. Leach,
J. P. Leahy,
S. Lowe,
D. Maino,
N. Mandolesi,
M. Maris,
E. Martínez-González,
P. R. Meinhold,
G. Morgante,
D. Pearson,
F. Perrotta,
G. Polenta,
T. Poutanen
, et al. (136 additional authors not shown)
Abstract:
The scientific performance of the Planck Low Frequency Instrument (LFI) after one year of in-orbit operation is presented. We describe the main optical parameters and discuss photometric calibration, white noise sensitivity, and noise properties. A preliminary evaluation of the impact of the main systematic effects is presented. For each of the performance parameters, we outline the methods used t…
▽ More
The scientific performance of the Planck Low Frequency Instrument (LFI) after one year of in-orbit operation is presented. We describe the main optical parameters and discuss photometric calibration, white noise sensitivity, and noise properties. A preliminary evaluation of the impact of the main systematic effects is presented. For each of the performance parameters, we outline the methods used to obtain them from the flight data and provide a comparison with pre-launch ground assessments, which are essentially confirmed in flight.
△ Less
Submitted 19 December, 2011; v1 submitted 11 January, 2011;
originally announced January 2011.
-
Planck Early Results: The Planck mission
Authors:
Planck Collaboration,
P. A. R. Ade,
N. Aghanim,
M. Arnaud,
M. Ashdown,
J. Aumont,
C. Baccigalupi,
M. Baker,
A. Balbi,
A. J. Banday,
R. B. Barreiro,
J. G. Bartlett,
E. Battaner,
K. Benabed,
K. Bennett,
A. Benoît,
J. -P. Bernard,
M. Bersanelli,
R. Bhatia,
J. J. Bock,
A. Bonaldi,
J. R. Bond,
J. Borrill,
F. R. Bouchet,
T. Bradshaw
, et al. (250 additional authors not shown)
Abstract:
The European Space Agency's Planck satellite was launched on 14 May 2009, and has been surveying the sky stably and continuously since 13 August 2009. Its performance is well in line with expectations, and it will continue to gather scientific data until the end of its cryogenic lifetime. We give an overview of the history of Planck in its first year of operations, and describe some of the key per…
▽ More
The European Space Agency's Planck satellite was launched on 14 May 2009, and has been surveying the sky stably and continuously since 13 August 2009. Its performance is well in line with expectations, and it will continue to gather scientific data until the end of its cryogenic lifetime. We give an overview of the history of Planck in its first year of operations, and describe some of the key performance aspects of the satellite. This paper is part of a package submitted in conjunction with Planck's Early Release Compact Source Catalogue, the first data product based on Planck to be released publicly. The package describes the scientific performance of the Planck payload, and presents results on a variety of astrophysical topics related to the sources included in the Catalogue, as well as selected topics on diffuse emission.
△ Less
Submitted 16 June, 2011; v1 submitted 11 January, 2011;
originally announced January 2011.
-
First Season QUIET Observations: Measurements of CMB Polarization Power Spectra at 43 GHz in the Multipole Range 25 <= ell <= 475
Authors:
QUIET Collaboration,
C. Bischoff,
A. Brizius,
I. Buder,
Y. Chinone,
K. Cleary,
R. N. Dumoulin,
A. Kusaka,
R. Monsalve,
S. K. Næss,
L. B. Newburgh,
R. Reeves,
K. M. Smith,
I. K. Wehus,
J. A. Zuntz,
J. T. L. Zwart,
L. Bronfman,
R. Bustos,
S. E. Church,
C. Dickinson,
H. K. Eriksen,
P. G. Ferreira,
T. Gaier,
J. O. Gundersen,
M. Hasegawa
, et al. (26 additional authors not shown)
Abstract:
The Q/U Imaging ExperimenT (QUIET) employs coherent receivers at 43GHz and 95GHz, operating on the Chajnantor plateau in the Atacama Desert in Chile, to measure the anisotropy in the polarization of the CMB. QUIET primarily targets the B modes from primordial gravitational waves. The combination of these frequencies gives sensitivity to foreground contributions from diffuse Galactic synchrotron ra…
▽ More
The Q/U Imaging ExperimenT (QUIET) employs coherent receivers at 43GHz and 95GHz, operating on the Chajnantor plateau in the Atacama Desert in Chile, to measure the anisotropy in the polarization of the CMB. QUIET primarily targets the B modes from primordial gravitational waves. The combination of these frequencies gives sensitivity to foreground contributions from diffuse Galactic synchrotron radiation. Between 2008 October and 2010 December, >10,000hours of data were collected, first with the 19-element 43GHz array (3458hours) and then with the 90-element 95GHz array. Each array observes the same four fields, selected for low foregrounds, together covering ~1000deg^2. This paper reports initial results from the 43GHz receiver which has an array sensitivity to CMB fluctuations of 69uK sqrt(s). The data were extensively studied with a large suite of null tests before the power spectra, determined with two independent pipelines, were examined. Analysis choices, including data selection, were modified until the null tests passed. Cross correlating maps with different telescope pointings is used to eliminate a bias. This paper reports the EE, BB and EB power spectra in the multipole range ell=25-475. With the exception of the lowest multipole bin for one of the fields, where a polarized foreground, consistent with Galactic synchrotron radiation, is detected with 3sigma significance, the E-mode spectrum is consistent with the LCDM model, confirming the only previous detection of the first acoustic peak. The B-mode spectrum is consistent with zero, leading to a measurement of the tensor-to-scalar ratio of r=0.35+1.06-0.87. The combination of a new time-stream double-demodulation technique, Mizuguchi-Dragone optics, natural sky rotation, and frequent boresight rotation leads to the lowest level of systematic contamination in the B-mode power so far reported, below the level of r=0.1
△ Less
Submitted 20 July, 2012; v1 submitted 14 December, 2010;
originally announced December 2010.
-
Design, development, and verification of the Planck Low Frequency Instrument 70 GHz Front-End and Back-End Modules
Authors:
J. Varis,
N. J. Hughes,
M. Laaninen,
V. -H. Kilpia,
P. Jukkala,
J. Tuovinen,
S. Ovaska,
P. Sjoman,
P. Kangaslahti,
T. Gaier,
R. Hoyland,
P. Meinhold,
A. Mennella,
M. Bersanelli,
R. C. Butler,
F. Cuttaia,
E. Franceschi,
R. Leonardi,
P. Leutenegger,
M. Malaspina,
N. Mandolesi,
M. Miccolis,
T. Poutanen,
H. Kurki-Suonio,
M. Sandri
, et al. (4 additional authors not shown)
Abstract:
70 GHz radiometer front-end and back-end modules for the Low Frequency Instrument of the European Space Agencys Planck Mission were built and tested. The operating principles and the design details of the mechanical structures are described along with the key InP MMIC low noise amplifiers and phase switches of the units. The units were tested in specially designed cryogenic vacuum chambers capab…
▽ More
70 GHz radiometer front-end and back-end modules for the Low Frequency Instrument of the European Space Agencys Planck Mission were built and tested. The operating principles and the design details of the mechanical structures are described along with the key InP MMIC low noise amplifiers and phase switches of the units. The units were tested in specially designed cryogenic vacuum chambers capable of producing the operating conditions required for Planck radiometers, specifically, a physical temperature of 20 K for the front-end modules, 300 K for the back-end modules and 4 K for the reference signal sources. Test results of the low noise amplifiers and phase switches, the front and back-end modules, and the combined results of both modules are discussed.
At 70 GHz frequency, the system noise temperature of the front and back end is 28 K; the effective bandwidth 16 GHz, and the 1/f spectrum knee frequency is 38 mHz. The test results indicate state-of-the-art performance at 70 GHz frequency and fulfil the Planck performance requirements.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Advanced pseudo-correlation radiometers for the Planck-LFI instrument
Authors:
A. Mennella,
M. Bersanelli,
R. C. Butler,
D. Maino,
N. Mandolesi,
G. Morgante,
L. Valenziano,
F. Villa,
T. Gaier,
M. Seiffert,
S. Levin,
C. Lawrence,
P. Meinhold,
P. Lubin,
J. Tuovinen,
J. Varis,
T. Karttaavi,
N. Hughes,
P. Jukkala,
P. Sjman,
P. Kangaslahti,
N. Roddis,
D. Kettle,
F. Winder,
E. Blackhurst
, et al. (12 additional authors not shown)
Abstract:
The LFI (Low Frequency Instrument) on board the ESA Planck satellite is constituted by an array of radiometric detectors actively cooled at 20 K in the 30-70 GHz frequency range in the focal plane of the Planck telescope. In this paper we present an overview of the LFI instrument, with a particular focus on the radiometer design. The adopted pseudo-correlation scheme uses a software balancing te…
▽ More
The LFI (Low Frequency Instrument) on board the ESA Planck satellite is constituted by an array of radiometric detectors actively cooled at 20 K in the 30-70 GHz frequency range in the focal plane of the Planck telescope. In this paper we present an overview of the LFI instrument, with a particular focus on the radiometer design. The adopted pseudo-correlation scheme uses a software balancing technique (with a tunable parameter called gain modulation factor) which is effective in reducing the radiometer susceptibility to amplifier instabilities also in presence of small non-idealities in the radiometric chain components, provided that the gain modulation factor is estimated with an accuracy of the order of 0.2%. These results have been recently confirmed by experimental laboratory measurements conducted on the LFI prototype radiometers at 30, 70 and 100 GHz.
△ Less
Submitted 7 July, 2003;
originally announced July 2003.