-
Measurement of the branching fraction of $J/ψ\rightarrowρπ$ at KEDR
Authors:
V. V. Anashin,
O. V. Anchugov,
A. V. Andrianov,
K. V. Astrelina,
V. M. Aulchenko,
E. M. Baldin,
G. N. Baranov,
A. K. Barladyan,
A. Yu. Barnyakov,
M. Yu. Barnyakov,
I. Yu. Basok,
A. M. Batrakov,
E. A. Bekhtenev,
O. V. Belikov,
D. E. Berkaev,
A. E. Blinov,
V. E. Blinov,
M. F. Blinov,
A. V. Bobrov,
V. S. Bobrovnikov,
A. V. Bogomyagkov,
D. Yu. Bolkhovityanov,
A. E. Bondar,
A. R. Buzykaev,
P. B. Cheblakov
, et al. (69 additional authors not shown)
Abstract:
We present the study of the decay $J/ψ\rightarrow ρπ$. The results are based on of 5.2~million $J/ψ$ events collected by the KEDR detector at the VEPP-4M collider. The branching fractions are measured to be $\B(J/ψ\rightarrow ρπ) = \big(2.072\pm 0.017 \pm 0.062 \big)\cdot 10^{-2}$ and $\B(J/ψ\rightarrow π^+π^-π^0) = \big(1.878 \pm 0.013 \pm 0.051 \big)\cdot 10^{-2}$, where the first uncertainties…
▽ More
We present the study of the decay $J/ψ\rightarrow ρπ$. The results are based on of 5.2~million $J/ψ$ events collected by the KEDR detector at the VEPP-4M collider. The branching fractions are measured to be $\B(J/ψ\rightarrow ρπ) = \big(2.072\pm 0.017 \pm 0.062 \big)\cdot 10^{-2}$ and $\B(J/ψ\rightarrow π^+π^-π^0) = \big(1.878 \pm 0.013 \pm 0.051 \big)\cdot 10^{-2}$, where the first uncertainties are statistical and the second systematic. Our results are more precise than the previous relative measurements.
△ Less
Submitted 8 June, 2023; v1 submitted 24 November, 2022;
originally announced November 2022.
-
Precise measurement of $R_{\text{uds}}$ and $R$ between 1.84 and 3.72 GeV at the KEDR detector
Authors:
V. V. Anashin,
O. V. Anchugov,
V. M. Aulchenko,
E. M. Baldin,
G. N. Baranov,
A. K. Barladyan,
A. Yu. Barnyakov,
M. Yu. Barnyakov,
S. E. Baru,
I. Yu. Basok,
A. M. Batrakov,
E. A. Bekhtenev,
A. E. Blinov,
V. E. Blinov,
A. V. Bobrov,
V. S. Bobrovnikov,
A. V. Bogomyagkov,
A. E. Bondar,
A. R. Buzykaev,
P. B. Cheblakov,
V. L. Dorohov,
S. I. Eidelman,
D. N. Grigoriev,
S. A. Glukhov,
V. V. Kaminskiy
, et al. (64 additional authors not shown)
Abstract:
The present work continues a series of the KEDR measurements of the $R$ value that started in 2010 at the VEPP-4M $e^+e^-$ collider. By combining new data with our previous results in this energy range we measured the values of $R_{\text{uds}}$ and $R$ at nine center-of-mass energies between 3.08 and 3.72 GeV. The total accuracy is about or better than $2.6\%$ at most of energy points with a syste…
▽ More
The present work continues a series of the KEDR measurements of the $R$ value that started in 2010 at the VEPP-4M $e^+e^-$ collider. By combining new data with our previous results in this energy range we measured the values of $R_{\text{uds}}$ and $R$ at nine center-of-mass energies between 3.08 and 3.72 GeV. The total accuracy is about or better than $2.6\%$ at most of energy points with a systematic uncertainty of about $1.9\%$. Together with the previous precise $R$ measurement at KEDR in the energy range 1.84-3.05 GeV, it constitutes the most detailed high-precision $R$ measurement near the charmonium production threshold.
△ Less
Submitted 8 November, 2018; v1 submitted 16 May, 2018;
originally announced May 2018.
-
Energy scale calibration of KEDR detector tagging system
Authors:
V. V. Kaminskiy,
N. Yu. Muchnoi,
V. N. Zhilich
Abstract:
The tagging system of the KEDR detector is a symmetrical focusing magnetic spectrometer for electrons and positrons scattered at small angles; it is embedded into the lattice of the VEPP-4M collider and intended for two-photon processes study. It measures scattered electron energy with resolution $ΔE/E_0=0.03\%...0.6\%$ ($E_0$ is the beam energy). For precise energy scale calibration two methods a…
▽ More
The tagging system of the KEDR detector is a symmetrical focusing magnetic spectrometer for electrons and positrons scattered at small angles; it is embedded into the lattice of the VEPP-4M collider and intended for two-photon processes study. It measures scattered electron energy with resolution $ΔE/E_0=0.03\%...0.6\%$ ($E_0$ is the beam energy). For precise energy scale calibration two methods are used: tagging of bremsstrahlung electron/positron by the photon energy measured by BGO calorimeter, and direct calibration using Compton backscattering spectrum edge. This report covers design and current status of the calibration system.
△ Less
Submitted 2 July, 2017; v1 submitted 29 May, 2017;
originally announced May 2017.
-
Proposal for VEPP-4M beam energy measurement using magnetic spectrometer with Compton calibration and photon detector
Authors:
V. V. Kaminskiy,
N. Yu. Muchnoi,
V. N. Zhilich
Abstract:
A method for circular e$^-$/e$^+$ accelerator beam energy measurement is proposed. Coordinate of an electron (or a positron) in a focusing magnetic spectrometer built in a circular accelerator depends on its energy, two spectrometer parameters, and the circulating beam energy. The spectrometer parameters can be defined using minimum electron energies from Compton backscattering with two laser wave…
▽ More
A method for circular e$^-$/e$^+$ accelerator beam energy measurement is proposed. Coordinate of an electron (or a positron) in a focusing magnetic spectrometer built in a circular accelerator depends on its energy, two spectrometer parameters, and the circulating beam energy. The spectrometer parameters can be defined using minimum electron energies from Compton backscattering with two laser wavelengths, and an additional photon coordinate detector. The photon detector is calibrated at once at well-known beam energy. The VEPP-4M collider has appropriate equipment for the method implementation: built-in focusing magnetic spectrometer, Compton calibration system with two lasers and a photon coordinate detector. Thus, the proposed technique could be implemented with minimum efforts; tests and further upgrade are planned. The beam energy can be defined with expected uncertainty better than $10^{-4}$.
△ Less
Submitted 28 June, 2017; v1 submitted 18 May, 2017;
originally announced May 2017.
-
Measurement of the two-photon exchange contribution to the elastic $e^{\pm}p$ scattering cross sections at the VEPP-3 storage ring
Authors:
I. A. Rachek,
J. Arrington,
V. F. Dmitriev,
V. V. Gauzshtein,
R. E. Gerasimov,
A. V. Gramolin,
R. J. Holt,
V. V. Kaminskiy,
B. A. Lazarenko,
S. I. Mishnev,
N. Yu. Muchnoi,
V. V. Neufeld,
D. M. Nikolenko,
R. Sh. Sadykov,
Yu. V. Shestakov,
V. N. Stibunov,
D. K. Toporkov,
H. de Vries,
S. A. Zevakov,
V. N. Zhilich
Abstract:
The ratio of the elastic $e^+ p$ to $e^- p$ scattering cross sections has been measured precisely, allowing the determination of the two-photon exchange contribution to these processes. This neglected contribution is believed to be the cause of the discrepancy between the Rosenbluth and polarization transfer methods of measuring the proton electromagnetic form factors. The experiment was performed…
▽ More
The ratio of the elastic $e^+ p$ to $e^- p$ scattering cross sections has been measured precisely, allowing the determination of the two-photon exchange contribution to these processes. This neglected contribution is believed to be the cause of the discrepancy between the Rosenbluth and polarization transfer methods of measuring the proton electromagnetic form factors. The experiment was performed at the VEPP-3 storage ring at beam energies of 1.6 and 1.0 GeV and at lepton scattering angles between $15^\circ$ and $105^\circ$. The data obtained show evidence of a significant two-photon exchange effect. The results are compared with several theoretical predictions.
△ Less
Submitted 12 February, 2015; v1 submitted 26 November, 2014;
originally announced November 2014.
-
Compton Backscattering for the Calibration of KEDR Tagging System
Authors:
V. V. Kaminskiy,
N. Yu. Muchnoi,
V. N. Zhilich
Abstract:
KEDR detector has the tagging system (TS) to study the gamma-gamma processes. To determine the two-photon invariant mass, the energies of the scattered at small angles electrons and positrons are measured by the magnetic spectrometer embedded into the lattice of the VEPP--4M collider. The energy resolution (scattered electron/positron energy resolution divided by the beam energy) of this spectrome…
▽ More
KEDR detector has the tagging system (TS) to study the gamma-gamma processes. To determine the two-photon invariant mass, the energies of the scattered at small angles electrons and positrons are measured by the magnetic spectrometer embedded into the lattice of the VEPP--4M collider. The energy resolution (scattered electron/positron energy resolution divided by the beam energy) of this spectrometer varies from 0.6% to 0.03% depending on the electron/positron energy. The Compton backscattering of laser radiation on the electron/positron beam is used for the accurate energy scale and resolution calibration of the tagging system. The report covers the design, recent results and current status of the KEDR TS calibration system.
△ Less
Submitted 17 June, 2014; v1 submitted 2 June, 2014;
originally announced June 2014.
-
Beam energy measurements for an experiment on elastic $e^{\pm}p$ scattering at the VEPP-3 storage ring
Authors:
V. V. Kaminskiy,
A. V. Gramolin,
S. I. Mishnev,
N. Yu. Muchnoi,
V. V. Neufeld,
D. M. Nikolenko,
I. A. Rachek,
D. K. Toporkov,
V. N. Zhilich
Abstract:
A precise comparison of the cross sections for the elastic scattering of electrons and positrons on protons was performed recently at the VEPP-3 storage ring in Novosibirsk, Russia. To provide the proposed accuracy, the energies of the electron and positron beams used during the experiment needed to be carefully maintained. This paper describes a special beam energy measurement system used in this…
▽ More
A precise comparison of the cross sections for the elastic scattering of electrons and positrons on protons was performed recently at the VEPP-3 storage ring in Novosibirsk, Russia. To provide the proposed accuracy, the energies of the electron and positron beams used during the experiment needed to be carefully maintained. This paper describes a special beam energy measurement system used in this experiment. This system is based on measuring the maximum energy of laser photons backscattered from electron and positron beams. It provides continuous beam energy measurements with a total relative uncertainty of less than $4.4 \cdot 10^{-5}$.
△ Less
Submitted 21 May, 2014; v1 submitted 18 March, 2014;
originally announced March 2014.