-
Two-dimensional Thomson scattering in high-repetition-rate laser-plasma experiments
Authors:
H. Zhang,
J. J. Pilgram,
C. G. Constantin,
L. Rovige,
P. V. Heuer,
S. Ghazaryan,
M. Kaloyan,
R. S. Dorst,
D. B. Schaeffer,
C. Niemann
Abstract:
We present the first two-dimensional (2D) optical Thomson scattering measurements of electron density and temperature in laser-produced plasmas. The novel instrument directly measures $n_e(x,y)$ and $T_e(x,y)$ in two dimensions over large spatial regions (cm$^2$) with sub-mm spatial resolution, by automatically translating the scattering volume while the plasma is produced repeatedly by irradiatin…
▽ More
We present the first two-dimensional (2D) optical Thomson scattering measurements of electron density and temperature in laser-produced plasmas. The novel instrument directly measures $n_e(x,y)$ and $T_e(x,y)$ in two dimensions over large spatial regions (cm$^2$) with sub-mm spatial resolution, by automatically translating the scattering volume while the plasma is produced repeatedly by irradiating a solid target with a high-repetition-rate laser beam (10 J, $\sim$10$^{12}$ W/cm$^2$, 1 Hz). In this paper, we describe the design and auto-alignment of the instrument, and the computerized fitting algorithm of the spectral distribution function to large data-sets of measured scattering spectra, as they transition from the collective to the non-collective regime with distance from the target. As an example, we present 2D scattering measurements in laser driven shock waves in ambient nitrogen gas at a pressure of 95 mTorr.
△ Less
Submitted 13 May, 2023;
originally announced May 2023.
-
Thomson scattering on the Large Plasma Device
Authors:
Sofiya Ghazaryan,
Marietta Kaloyan,
Walter Gekelman,
Zoltan Lucky,
Stephen Vincena,
Shreekrishna P. Tripathi,
1 Patrick Pribyl,
Christoph Niemann
Abstract:
We have developed a non-collective Thomson scattering diagnostic for measurements of electron density and temperature on the Large Plasma Device. A triple grating spectrometer with a tunable notch filter is used to discriminate the faint scattering signal from the stray light. In this paper we describe the diagnostic and its calibration via Raman scattering, and present the first measurements perf…
▽ More
We have developed a non-collective Thomson scattering diagnostic for measurements of electron density and temperature on the Large Plasma Device. A triple grating spectrometer with a tunable notch filter is used to discriminate the faint scattering signal from the stray light. In this paper we describe the diagnostic and its calibration via Raman scattering, and present the first measurements performed with the fully commissioned system. Depending on the discharge conditions, the measured densities and temperatures range from 4.0$\times$10$^{12}$ cm$^{-3}$ to 2.8$\times$10$^{13}$ cm$^{-3}$, and from 1.2 eV to 6.8 eV, respectively. The variation of the measurement error with plasma parameters and discharges averaged is also discussed.
△ Less
Submitted 26 April, 2022;
originally announced April 2022.
-
High Repetition Rate Exploration of the Biermann Battery Effect in Laser Produced Plasmas Over Large Spatial Regions
Authors:
J. J. Pilgram,
M. B. P. Adams,
C. G. Constantin,
P. V. Heuer,
S. Ghazaryan,
M. Kaloyan,
R. S. Dorst,
D. B. Schaeffer,
P. Tzeferacos,
C. Niemann
Abstract:
In this paper we present a high-repetition-rate experimental platform for examining the spatial structure and evolution of Biermann generated magnetic fields in laser-produced plasmas. We have extended the work of prior experiments, which spanned over millimeter scales, by spatially measuring magnetic fields in multiple planes on centimeter scales over thousands of laser shots. Measurements with m…
▽ More
In this paper we present a high-repetition-rate experimental platform for examining the spatial structure and evolution of Biermann generated magnetic fields in laser-produced plasmas. We have extended the work of prior experiments, which spanned over millimeter scales, by spatially measuring magnetic fields in multiple planes on centimeter scales over thousands of laser shots. Measurements with magnetic flux probes show azimuthally symmetric magnetic fields that range from 60 G at 0.7 cm from the target to 7 G at 4.2 cm from the target. The expansion rate of the magnetic fields and evolution of current density structures are also mapped and examined. Electron temperature and density of the laser-produced plasma are measured with optical Thomson scattering and used to directly calculate a magnetic Reynolds number of $1.4\times 10^4$, confirming that magnetic advection is dominant $\ge 1.5$ cm from the target surface. The results are compared to FLASH simulations, which show qualitative agreement with the data.
△ Less
Submitted 24 February, 2022; v1 submitted 4 November, 2021;
originally announced November 2021.
-
Raster Thomson scattering in large-scale laser plasmas produced at high repetition rate
Authors:
M. Kaloyan,
S. Ghazaryan,
C. G. Constantin,
R. S. Dorst,
P. V. Heuer,
J. J. Pilgram,
D. B. Schaeffer,
C. Niemann
Abstract:
We present optical Thomson scattering measurements of electron density and temperature in a large-scale (~2 cm) exploding laser plasma produced by irradiating a solid target with a high energy (5-10 J) laser pulse at high repetition rate (1 Hz). The Thomson scattering diagnostic matches this high repetition rate. Unlike previous work performed in single shots at much higher energies, the instrumen…
▽ More
We present optical Thomson scattering measurements of electron density and temperature in a large-scale (~2 cm) exploding laser plasma produced by irradiating a solid target with a high energy (5-10 J) laser pulse at high repetition rate (1 Hz). The Thomson scattering diagnostic matches this high repetition rate. Unlike previous work performed in single shots at much higher energies, the instrument allows point measurements anywhere inside the plasma by automatically translating the scattering volume using motorized stages as the experiment is repeated at 1 Hz. Measured densities around 4$\times 10^{16}$ cm$^{-3}$ and temperatures around 7 eV result in a scattering parameter near unity, depending on the distance from the target. The measured spectra show the transition from collective scattering close to the target to non-collective scattering at larger distances. Densities obtained by fitting the weakly collective spectra agree to within 10% with an irradiance calibration performed via Raman scattering in nitrogen.
△ Less
Submitted 4 October, 2021; v1 submitted 26 May, 2021;
originally announced May 2021.
-
Silica Raman scattering probe for absolute calibration of Thomson scattering spectrometers
Authors:
Sofiya Ghazaryan,
Marietta Kaloyan,
Christoph Niemann
Abstract:
We have developed a solid state probe for an absolute irradiance calibration of the Thomson scattering system on the Large Plasma Device (LAPD), based on Raman scattering off silica. Measurements performed with a triple-grating spectrometer have investigated the intensities of a pulsed laser beam Raman scattered off crystalline and amorphous silica over a range of temperatures of relevance to the…
▽ More
We have developed a solid state probe for an absolute irradiance calibration of the Thomson scattering system on the Large Plasma Device (LAPD), based on Raman scattering off silica. Measurements performed with a triple-grating spectrometer have investigated the intensities of a pulsed laser beam Raman scattered off crystalline and amorphous silica over a range of temperatures of relevance to the LAPD (299 - 498 K). The data were compared with Rayleigh and Raman scattering intensities in gaseous nitrogen. The measurements show that Raman scattering off quartz allows rapid and accurate alignment and calibration of Thomson scattering systems in plasma physics experiments that cannot be calibrated using conventional methods.
△ Less
Submitted 24 May, 2021;
originally announced May 2021.