Demonstration of a picosecond Bragg switch for hard x-rays in a synchrotron-based pump-probe experiment
Authors:
M. Sander,
R. Bauer,
V. Kabanova,
M. Levantino,
M. Wulff,
D. Pfuetzenreuter,
J. Schwarzkopf,
P. Gaal
Abstract:
We report a benchmark experiment that demonstrates shortening of hard x-ray pulses in a synchrotron-based optical pump - x-ray probe experiment. The pulse shortening device, a picosecond Bragg switch, reduces the temporal resolution of an incident x-ray pulse to 7.5 ps. We employ the Bragg switch to monitor propagating sound waves in nanometer-thin epitaxial films. With the experimental data we in…
▽ More
We report a benchmark experiment that demonstrates shortening of hard x-ray pulses in a synchrotron-based optical pump - x-ray probe experiment. The pulse shortening device, a picosecond Bragg switch, reduces the temporal resolution of an incident x-ray pulse to 7.5 ps. We employ the Bragg switch to monitor propagating sound waves in nanometer-thin epitaxial films. With the experimental data we infer pulse duration, diffraction efficiency and switching contrast of the device. A detailed efficiency analysis shows, that the switch can deliver up to 1010 photons/sec in high-repetition rate synchrotron experiments.
△ Less
Submitted 15 May, 2019; v1 submitted 19 December, 2018;
originally announced December 2018.
Results on the primary CR spectrum and composition reconstructed with the SPHERE-2 detector
Authors:
R. A. Antonov,
S. P. Beschapov,
E. A. Bonvech,
D. V. Chernov,
T. A. Dzhatdoev,
Mir. Finger,
Mix. Finger,
V. I. Galkin,
N. V. Kabanova,
A. S. Petkun,
D. A. Podgrudkov,
T. M. Roganova,
S. B. Shaulov,
T. I. Sysoeva
Abstract:
First preliminary results of the balloon-borne experiment SPHERE-2 on the all-nuclei primary cosmic rays (PCR) spectrum and primary composition are presented. The primary spectrum in the energy range $10^{16}$--$5\cdot10^{17}$ eV was reconstructed using characteristics of Vavilov-Cherenkov radiation of extensive air showers (EAS), reflected from a snow surface. Several sources of systematic uncert…
▽ More
First preliminary results of the balloon-borne experiment SPHERE-2 on the all-nuclei primary cosmic rays (PCR) spectrum and primary composition are presented. The primary spectrum in the energy range $10^{16}$--$5\cdot10^{17}$ eV was reconstructed using characteristics of Vavilov-Cherenkov radiation of extensive air showers (EAS), reflected from a snow surface. Several sources of systematic uncertainties of the spectrum were analysed. A method for separation of the primary nuclei' groups based on the lateral distribution function' (LDF) steepness parameter is presented. Preliminary estimate of the mean light nuclei' fraction $f_{30-150}$ at energies $3\cdot10^{16}$--$1.5\cdot10^{17}$ eV was performed and yielded $f_{30-150}$= (21$\pm$11)%.
△ Less
Submitted 4 October, 2012;
originally announced October 2012.