The stable climate of KELT-9b
Authors:
K. D. Jones,
B. M. Morris,
B. -O. Demory,
K. Heng,
M. J. Hooton,
N. Billot,
D. Ehrenreich,
S. Hoyer,
A. E. Simon,
M. Lendl,
O. D. S. Demangeon,
S. G. Sousa,
A. Bonfanti,
T. G. Wilson,
S. Salmon,
Sz. Csizmadia,
H. Parviainen,
G. Bruno,
Y. Alibert,
R. Alonso,
G. Anglada,
T. Bárczy,
D. Barrado y Navascues,
S. C. C. Barros,
W. Baumjohann
, et al. (54 additional authors not shown)
Abstract:
Even among the most irradiated gas giants, so-called ultra-hot Jupiters, KELT-9b stands out as the hottest planet thus far discovered with a dayside temperature of over 4500K. At these extreme irradiation levels, we expect an increase in heat redistribution efficiency and a low Bond albedo owed to an extended atmosphere with molecular hydrogen dissociation occurring on the planetary dayside. We pr…
▽ More
Even among the most irradiated gas giants, so-called ultra-hot Jupiters, KELT-9b stands out as the hottest planet thus far discovered with a dayside temperature of over 4500K. At these extreme irradiation levels, we expect an increase in heat redistribution efficiency and a low Bond albedo owed to an extended atmosphere with molecular hydrogen dissociation occurring on the planetary dayside. We present new photometric observations of the KELT-9 system throughout 4 full orbits and 9 separate occultations obtained by the 30cm space telescope CHEOPS. The CHEOPS bandpass, located at optical wavelengths, captures the peak of the thermal emission spectrum of KELT-9b. In this work we simultaneously analyse CHEOPS phase curves along with public phase curves from TESS and Spitzer to infer joint constraints on the phase curve variation, gravity-darkened transits, and occultation depth in three bandpasses, as well as derive 2D temperature maps of the atmosphere at three different depths. We find a day-night heat redistribution efficiency of $\sim$0.3 which confirms expectations of enhanced energy transfer to the planetary nightside due to dissociation and recombination of molecular hydrogen. We also calculate a Bond albedo consistent with zero. We find no evidence of variability of the brightness temperature of the planet, excluding variability greater than 1% (1$σ$).
△ Less
Submitted 9 August, 2022;
originally announced August 2022.
Identifying Oscillations Injected by Inverter-Based Solar Energy Sources
Authors:
Chen Wang,
Luigi Vanfretti,
Chetan Mishra,
Kevin D. Jones,
R. Matthew Gardner
Abstract:
Inverter-based solar energy sources are becoming widely integrated into modern power systems. However, their impacts on the system in the frequency domain are rarely investigated at a higher frequency range than conventional electromechanical oscillations. This paper presents evidence of the emergence of an oscillation mode injected by inverter-based solar energy sources in Dominion Energy's servi…
▽ More
Inverter-based solar energy sources are becoming widely integrated into modern power systems. However, their impacts on the system in the frequency domain are rarely investigated at a higher frequency range than conventional electromechanical oscillations. This paper presents evidence of the emergence of an oscillation mode injected by inverter-based solar energy sources in Dominion Energy's service territory. This new mode was recognized from the analysis of real-world ambient synchrophasor and point-of-wave data. The analysis was performed by develo** customized synchrophasor analysis tools deployed on the PredictiveGrid^{TM} platform implemented at Dominion Energy. Herein, we describe and illustrate the preliminary analysis results acquired from spectrogram observations, power spectral density plots, and mode shape estimation. The emergence and propagation of this new mode in Dominion Energy's footprint is illustrated using a heatmap based on a proposed frequency component energy metric, which helps to assess this oscillation's spread and impact.
△ Less
Submitted 23 February, 2022;
originally announced February 2022.
Transmission Lines Positive Sequence Parameters Estimation and Instrument Transformers Calibration Based on PMU Measurement Error Model
Authors:
Chen Wang,
Virgilio A. Centeno,
Kevin D. Jones,
Duotong Yang
Abstract:
Phasor Measurement Unit measurement data have been widely used in nowadays power system applications both in steady state and dynamic analysis. The performance of these applications running in utilities' energy management system depends heavily on an accurate positive sequence power system model. However, it is impractical to find this accurate model with transmission line parameters calculated di…
▽ More
Phasor Measurement Unit measurement data have been widely used in nowadays power system applications both in steady state and dynamic analysis. The performance of these applications running in utilities' energy management system depends heavily on an accurate positive sequence power system model. However, it is impractical to find this accurate model with transmission line parameters calculated directly with the PMU measurements due to ratio errors brought by instrument transformers and communication errors brought by PMUs. Therefore, a methodology is proposed in this paper to estimate the actual transmission lines parameters throughout the whole system and, at the same time, calibrate the corresponding instrument transformers. A PMU positive sequence measurement error model is proposed targeting at the aforementioned errors, which is applicable to both transposed and un-transposed transmission lines. A single line parameters estimation method is designed based on Least Squares Estimation and this error model. This method requires only one set of reference measurements and the accuracy can be propagated throughout the whole network along with the topology acquired by the introduced Edge-based Breadth-first Search algorithm. The IEEE 118-bus system and the Texas 2000-bus system are used to demonstrate the effectiveness and efficiency of the proposed method. The potential for deployment in reality is also discussed.
△ Less
Submitted 4 November, 2019;
originally announced November 2019.