-
Design and Performance of a Novel Low Energy Multi-Species Beamline for the ALPHA Antihydrogen Experiment
Authors:
C. J. Baker,
W. Bertsche,
A. Capra,
C. L. Cesar,
M. Charlton,
A. J. Christensen,
R. Collister,
A. Cridland Mathad,
S. Eriksson,
A. Evans,
N. Evetts,
S. Fabbri,
J. Fajans,
T. Friesen,
M. C. Fujiwara,
D. R. Gill,
P. Grandemange,
P. Granum,
J. S. Hangst,
M. E. Hayden,
D. Hodgkinson,
C. A. Isaac,
M. A. Johnson,
J. M. Jones,
S. A. Jones
, et al. (25 additional authors not shown)
Abstract:
The ALPHA Collaboration, based at the CERN Antiproton Decelerator, has recently implemented a novel beamline for low-energy ($\lesssim$ 100 eV) positron and antiproton transport between cylindrical Penning traps that have strong axial magnetic fields. Here, we describe how a combination of semianalytical and numerical calculations were used to optimise the layout and design of this beamline. Using…
▽ More
The ALPHA Collaboration, based at the CERN Antiproton Decelerator, has recently implemented a novel beamline for low-energy ($\lesssim$ 100 eV) positron and antiproton transport between cylindrical Penning traps that have strong axial magnetic fields. Here, we describe how a combination of semianalytical and numerical calculations were used to optimise the layout and design of this beamline. Using experimental measurements taken during the initial commissioning of the instrument, we evaluate its performance and validate the models used for its development. By combining data from a range of sources, we show that the beamline has a high transfer efficiency, and estimate that the percentage of particles captured in the experiments from each bunch is (78 $\pm$ 3)% for up to $10^{5}$ antiprotons, and (71 $\pm$ 5)% for bunches of up to $10^{7}$ positrons.
△ Less
Submitted 17 November, 2022;
originally announced November 2022.
-
Classification of Epithelial Ovarian Carcinoma Whole-Slide Pathology Images Using Deep Transfer Learning
Authors:
Yi** Wang,
David Farnell,
Hossein Farahani,
Mitchell Nursey,
Basile Tessier-Cloutier,
Steven J. M. Jones,
David G. Huntsman,
C. Blake Gilks,
Ali Bashashati
Abstract:
Ovarian cancer is the most lethal cancer of the female reproductive organs. There are $5$ major histological subtypes of epithelial ovarian cancer, each with distinct morphological, genetic, and clinical features. Currently, these histotypes are determined by a pathologist's microscopic examination of tumor whole-slide images (WSI). This process has been hampered by poor inter-observer agreement (…
▽ More
Ovarian cancer is the most lethal cancer of the female reproductive organs. There are $5$ major histological subtypes of epithelial ovarian cancer, each with distinct morphological, genetic, and clinical features. Currently, these histotypes are determined by a pathologist's microscopic examination of tumor whole-slide images (WSI). This process has been hampered by poor inter-observer agreement (Cohen's kappa $0.54$-$0.67$). We utilized a \textit{two}-stage deep transfer learning algorithm based on convolutional neural networks (CNN) and progressive resizing for automatic classification of epithelial ovarian carcinoma WSIs. The proposed algorithm achieved a mean accuracy of $87.54\%$ and Cohen's kappa of $0.8106$ in the slide-level classification of $305$ WSIs; performing better than a standard CNN and pathologists without gynecology-specific training.
△ Less
Submitted 28 June, 2020; v1 submitted 21 May, 2020;
originally announced May 2020.
-
Direct comparisons of European primary and secondary frequency standards via satellite techniques
Authors:
F. Riedel,
A. Al-Masoudi,
E. Benkler,
S. Dörscher,
V. Gerginov,
C. Grebing,
S. Häfner,
N. Huntemann,
B. Lipphardt,
C. Lisdat,
E. Peik,
D. Piester,
C. Sanner,
C. Tamm,
S. Weyers,
H. Denker,
L. Timmen,
C. Voigt,
D. Calonico,
G. Cerretto,
G. A. Costanzo,
F. Levi,
I. Sesia,
J. Achkar,
J. Guèna
, et al. (24 additional authors not shown)
Abstract:
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taki…
▽ More
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taking into account correlations and gaps in the measurement data, combined overall uncertainties in the range of $1.8 \times 10^{-16}$ to $3.5 \times 10^{-16}$ for the optical clock comparisons were found. The comparison of the fountain clocks yields results with a maximum relative frequency difference of $6.9 \times 10^{-16}$, and combined overall uncertainties in the range of $4.8 \times 10^{-16}$ to $7.7 \times 10^{-16}$.
△ Less
Submitted 9 October, 2019;
originally announced October 2019.
-
Measurement of differential polarizabilities at a mid-infrared wavelength in $^{171}\mathrm{Yb}^+$
Authors:
C F A Baynham,
E A Curtis,
R M Godun,
J M Jones,
P B R Nisbet-Jones,
P E G Baird,
K Bongs,
P Gill,
T Fordell,
T Hieta,
T Lindvall,
M T Spidell,
J H Lehman
Abstract:
An atom exposed to an electric field will experience Stark shifts of its internal energy levels, proportional to their polarizabilities. In optical frequency metrology, the Stark shift due to background black-body radiation (BBR) modifies the frequency of the optical clock transition, and often represents a large contribution to a clock's uncertainty budget. For clocks based on singly-ionized ytte…
▽ More
An atom exposed to an electric field will experience Stark shifts of its internal energy levels, proportional to their polarizabilities. In optical frequency metrology, the Stark shift due to background black-body radiation (BBR) modifies the frequency of the optical clock transition, and often represents a large contribution to a clock's uncertainty budget. For clocks based on singly-ionized ytterbium, the ion's complex structure makes this shift difficult to calculate theoretically. We present a measurement of the differential polarizabilities of two ultra-narrow optical clock transitions present in $^{171}\mathrm{Yb}^+$, performed by exposing the ion to an oscillating electric field at a wavelength in the region of room temperature BBR spectra. By measuring the frequency shift to the transitions caused by a laser at $λ=7.17 μm$, we obtain values for scalar and tensor differential polarizabilities with uncertainties at the percent level for both the electric quadrupole and octupole transitions at 436nm and 467nm respectively. These values agree with previously reported experimental measurements and, in the case of the electric quadrupole transition, allow a 5-fold improvement in the determination of the room-temperature BBR shift.
However, we note significant concerns over the validity of the uncertainty charactarization presented and draw the reader's attention to the Note on applicability section for a discussion.
△ Less
Submitted 10 September, 2020; v1 submitted 30 January, 2018;
originally announced January 2018.
-
Absolute frequency measurement of the $^2$S$_{1/2} \rightarrow ^2$F$_{7/2}$ optical clock transition in $^{171}$Yb$^+$ with an uncertainty of $4\times 10^{-16}$ using a frequency link to International Atomic Time
Authors:
Charles F. A. Baynham,
Rachel M. Godun,
Jonathan M. Jones,
Steven A. King,
Peter B. R. Nisbet-Jones,
Fred Baynes,
Antoine Rolland,
Patrick E. G. Baird,
Kai Bongs,
Patrick Gill,
Helen S. Margolis
Abstract:
The highly forbidden $^2$S$_{1/2} \rightarrow ^2$F$_{7/2}$ electric octupole transition in $^{171}$Yb$^+$ is a potential candidate for a redefinition of the SI second. We present a measurement of the absolute frequency of this optical transition, performed using a frequency link to International Atomic Time to provide traceability to the SI second. The $^{171}$Yb$^+$ optical frequency standard was…
▽ More
The highly forbidden $^2$S$_{1/2} \rightarrow ^2$F$_{7/2}$ electric octupole transition in $^{171}$Yb$^+$ is a potential candidate for a redefinition of the SI second. We present a measurement of the absolute frequency of this optical transition, performed using a frequency link to International Atomic Time to provide traceability to the SI second. The $^{171}$Yb$^+$ optical frequency standard was operated for 76% of a 25-day period, with the absolute frequency measured to be 642 121 496 772 645.14(26) Hz. The fractional uncertainty of $4.0 \times 10 ^{-16}$ is comparable to that of the best previously reported measurement, which was made by a direct comparison to local caesium primary frequency standards.
△ Less
Submitted 27 October, 2017; v1 submitted 3 July, 2017;
originally announced July 2017.
-
A Single-Ion Trap with Minimized Ion-Environment Interactions
Authors:
P. B. R. Nisbet-Jones,
S. A. King,
J. M. Jones,
R. M. Godun,
C. F. A. Baynham,
K. Bongs,
M. Doležal,
P. Balling,
P. Gill
Abstract:
We present a new single-ion endcap trap for high precision spectroscopy that has been designed to minimize ion-environment interactions. We describe the design in detail and then characterize the working trap using a single trapped 171 Yb ion. Excess micromotion has been eliminated to the resolution of the detection method and the trap exhibits an anomalous phonon heating rate of d<n> /dt = 24 +30…
▽ More
We present a new single-ion endcap trap for high precision spectroscopy that has been designed to minimize ion-environment interactions. We describe the design in detail and then characterize the working trap using a single trapped 171 Yb ion. Excess micromotion has been eliminated to the resolution of the detection method and the trap exhibits an anomalous phonon heating rate of d<n> /dt = 24 +30/-24 per second. The thermal properties of the trap structure have also been measured with an effective temperature rise at the ion's position of 0.14 +/- 0.14 K. The small perturbations to the ion caused by this trap make it suitable to be used for an optical frequency standard with fractional uncertainties below the 10^-18 level.
△ Less
Submitted 19 March, 2021; v1 submitted 21 October, 2015;
originally announced October 2015.
-
Analysis of thermal radiation in ion traps for optical frequency standards
Authors:
Miroslav Doležal,
Petr Balling,
Peter B R Nisbet-Jones,
Steven A King,
Jonathan M Jones,
Hugh A Klein,
Patrick Gill,
Thomas Lindvall,
Anders E Wallin,
Mikko Merimaa,
Christian Tamm,
Christian Sanner,
Nils Huntemann,
Nils Scharnhorst,
Ian D Leroux,
Piet O Schmidt,
Tobias Burgermeister,
Tanja E Mehlstäubler,
Ekkehard Peik
Abstract:
In many of the high-precision optical frequency standards with trapped atoms or ions that are under development to date, the AC Stark shift induced by thermal radiation leads to a major contribution to the systematic uncertainty. We present an analysis of the inhomogeneous thermal environment experienced by ions in various types of ion traps. Finite element models which allow the determination of…
▽ More
In many of the high-precision optical frequency standards with trapped atoms or ions that are under development to date, the AC Stark shift induced by thermal radiation leads to a major contribution to the systematic uncertainty. We present an analysis of the inhomogeneous thermal environment experienced by ions in various types of ion traps. Finite element models which allow the determination of the temperature of the trap structure and the temperature of the radiation were developed for 5 ion trap designs, including operational traps at PTB and NPL and further optimized designs. Models were refined based on comparison with infrared camera measurement until an agreement of better than 10% of the measured temperature rise at critical test points was reached. The effective temperature rises of the radiation seen by the ion range from 0.8 K to 2.1 K at standard working conditions. The corresponding fractional frequency shift uncertainties resulting from the uncertainty in temperature are in the 10-18 range for optical clocks based on the Sr+ and Yb+ E2 transitions, and even lower for Yb+ E3, In+ and Al+. Issues critical for heating of the trap structure and its predictability were identified and design recommendations developed.
△ Less
Submitted 6 November, 2015; v1 submitted 19 October, 2015;
originally announced October 2015.
-
Frequency comparison of ${}^{171}$Yb${}^+$ ion optical clocks at PTB and NPL via GPS PPP
Authors:
J. Leute,
N. Huntemann,
B. Lipphardt,
Chr. Tamm,
P. B. R. Nisbet-Jones,
S. A. King,
R. M. Godun,
J. M. Jones,
H. S. Margolis,
P. B. Whibberley,
A. Wallin,
M. Merimaa,
P. Gill,
E. Peik
Abstract:
We used Precise Point Positioning, a well-established GPS carrier-phase frequency transfer method to perform a direct remote comparison of two optical frequency standards based on single laser-cooled $^{171}$Yb$^+$ ions operated at NPL, UK and PTB, Germany. At both institutes an active hydrogen maser serves as a flywheel oscillator; it is connected to a GPS receiver as an external frequency refere…
▽ More
We used Precise Point Positioning, a well-established GPS carrier-phase frequency transfer method to perform a direct remote comparison of two optical frequency standards based on single laser-cooled $^{171}$Yb$^+$ ions operated at NPL, UK and PTB, Germany. At both institutes an active hydrogen maser serves as a flywheel oscillator; it is connected to a GPS receiver as an external frequency reference and compared simultaneously to a realization of the unperturbed frequency of the ${{}^2S_{1/2}(F=0)-{}^2D_{3/2}(F=2)}$ electric quadrupole transition in ${}^{171}$Yb${}^+$ via an optical femtosecond frequency comb. To profit from long coherent GPS link measurements we extrapolate over the various data gaps in the optical clock to maser comparisons which introduces maser noise to the frequency comparison but improves the uncertainty from the GPS link. We determined the total statistical uncertainty consisting of the GPS link uncertainty and the extrapolation uncertainties for several extrapolation schemes. Using the extrapolation scheme with the smallest combined uncertainty, we find a fractional frequency difference $y(\mathrm{PTB})-y(\mathrm{NPL})$ of $-1.3(1.2)\times 10^{-15}$ for a total measurement time of 67 h. This result is consistent with an agreement of both optical clocks and with recent absolute frequency measurements against caesium fountain clocks.
△ Less
Submitted 15 July, 2015;
originally announced July 2015.
-
New class of compounds - variators - are reprogramming substrate specificity of H4K12Ac, H4K16Ac and H4K20Ac epigenetic marks reading bromodomain of BPTF protein
Authors:
Oleksandr Ya Yakovenko,
Sreeja Leelakumari,
Ganna Vashchenko,
Albert Badiong,
Steven J. M. Jones
Abstract:
Previously reported [http://arxiv.longhoe.net/abs/1506.06433] reprogramming of substrate specificity of H3K4Me3 epigenetic marks reading PHD domain of BPTF protein illustrates therapeutic potential of a new class of non-inhibitor small organic compounds - variators. Here we address the question about reproducibility of rational design of variators by reprogramming of the second epigenetic marks reading do…
▽ More
Previously reported [http://arxiv.longhoe.net/abs/1506.06433] reprogramming of substrate specificity of H3K4Me3 epigenetic marks reading PHD domain of BPTF protein illustrates therapeutic potential of a new class of non-inhibitor small organic compounds - variators. Here we address the question about reproducibility of rational design of variators by reprogramming of the second epigenetic marks reading domain of BPTF protein - bromodomain. Bromodomain of BPTF binds to epigenetic marks in form of acetylated lysine of histone H4 (H4K12Ac, H4K16Ac and H4K20Ac), which physicochemical properties and binding mode differs considerably from those of methylated H3K4 marks. Thus, detailed description of computational approach for reprogramming of bromodomain substrate specificity illustrates both general and target specific attributes of computer aided variators design.
△ Less
Submitted 22 June, 2015;
originally announced June 2015.
-
New class of compounds - variators - are reprogramming substrate specificity of H3K4me3 epigenetic marks reading PHD domain of BPTF protein
Authors:
Oleksandr Ya Yakovenko,
Sreeja Leelakumari,
Ganna Vashchenko,
Pierre Cheung,
Albert Badiong,
Steven J. M. Jones
Abstract:
In lymphoma, mutations in genes of histone modifying proteins are frequently observed. Notably, somatic mutations in the activatory histone modification writing protein MLL2 and the repressive modification writer EZH2 are the most frequent. Gain of function mutations are typically detected in EZH2 whilst MLL2 mutations are usually observed as conferring a homozygous loss of function. The gain-of-f…
▽ More
In lymphoma, mutations in genes of histone modifying proteins are frequently observed. Notably, somatic mutations in the activatory histone modification writing protein MLL2 and the repressive modification writer EZH2 are the most frequent. Gain of function mutations are typically detected in EZH2 whilst MLL2 mutations are usually observed as conferring a homozygous loss of function. The gain-of-function mutations in EZH2 provide an obvious target for the development of inhibitors with therapeutic potential. To counter the loss of functional MLL2 protein, we computationally predicted compounds that are able to modulate the reader of the corresponding modifications, BPTF, to recognize other forms of the histone H3 lysine 4, instead of the tri-methylated form normally produced by MLL2. By forming a synthetic triple-complex of a compound, the histone H3 tail and BPTF we potentially circumvent the requirement for functional MLL2 methyl-transferase through the modulation of BPTF activity. Here we show a proof-of-principle that special compounds, named variators, can reprogram selectivity of protein binding and thus create artificial regulatory pathways which can have a potential therapeutic role. A therapeutic role of BPTF variators may extend to other diseases that involve loss of MLL2 function, such as Kabuki syndrome or the aberrant functioning of H3K4 modification as observed in Huntington disease and in memory formation.
△ Less
Submitted 21 June, 2015;
originally announced June 2015.
-
Frequency ratio of two optical clock transitions in $^{171}$Yb$^+$ and constraints on the time-variation of fundamental constants
Authors:
R. M. Godun,
P. B. R. Nisbet-Jones,
J. M. Jones,
S. A. King,
L. A. M. Johnson,
H. S. Margolis,
K. Szymaniec,
S. N. Lea,
K. Bongs,
P. Gill
Abstract:
Singly-ionized ytterbium, with ultra-narrow optical clock transitions at 467 nm and 436 nm, is a convenient system for the realization of optical atomic clocks and tests of present-day variation of fundamental constants. We present the first direct measurement of the frequency ratio of these two clock transitions, without reference to a cesium primary standard, and using the same single ion of 171…
▽ More
Singly-ionized ytterbium, with ultra-narrow optical clock transitions at 467 nm and 436 nm, is a convenient system for the realization of optical atomic clocks and tests of present-day variation of fundamental constants. We present the first direct measurement of the frequency ratio of these two clock transitions, without reference to a cesium primary standard, and using the same single ion of 171Yb+. The absolute frequencies of both transitions are also presented, each with a relative standard uncertainty of $6\times 10^{-16}$. Combining our results with those from other experiments, we report a three-fold improvement in the constraint on the time-variation of the proton-to-electron mass ratio, $\dotμ/μ = 0.2(1.1)\times 10^{-16}$ year$^{-1}$, along with an improved constraint on time-variation of the fine structure constant, $\dotα/α = -0.7(2.1)\times 10^{-17}$ year$^{-1}$.
△ Less
Submitted 1 October, 2014; v1 submitted 1 July, 2014;
originally announced July 2014.
-
KiWi: A Scalable Subspace Clustering Algorithm for Gene Expression Analysis
Authors:
Obi L. Griffith,
Byron J. Gao,
Mikhail Bilenky,
Yuliya Prichyna,
Martin Ester,
Steven J. M. Jones
Abstract:
Subspace clustering has gained increasing popularity in the analysis of gene expression data. Among subspace cluster models, the recently introduced order-preserving sub-matrix (OPSM) has demonstrated high promise. An OPSM, essentially a pattern-based subspace cluster, is a subset of rows and columns in a data matrix for which all the rows induce the same linear ordering of columns. Existing OPS…
▽ More
Subspace clustering has gained increasing popularity in the analysis of gene expression data. Among subspace cluster models, the recently introduced order-preserving sub-matrix (OPSM) has demonstrated high promise. An OPSM, essentially a pattern-based subspace cluster, is a subset of rows and columns in a data matrix for which all the rows induce the same linear ordering of columns. Existing OPSM discovery methods do not scale well to increasingly large expression datasets. In particular, twig clusters having few genes and many experiments incur explosive computational costs and are completely pruned off by existing methods. However, it is of particular interest to determine small groups of genes that are tightly coregulated across many conditions. In this paper, we present KiWi, an OPSM subspace clustering algorithm that is scalable to massive datasets, capable of discovering twig clusters and identifying negative as well as positive correlations. We extensively validate KiWi using relevant biological datasets and show that KiWi correctly assigns redundant probes to the same cluster, groups experiments with common clinical annotations, differentiates real promoter sequences from negative control sequences, and shows good association with cis-regulatory motif predictions.
△ Less
Submitted 13 April, 2009;
originally announced April 2009.