-
Applying Bayesian Inference and deterministic anisotropy to retrieve the molecular structure $|Ψ(\boldsymbol{R})|^2$ distribution from gas-phase diffraction experiments
Authors:
Kareem Hegazy,
Varun Makhija,
Phil Bucksbaum,
Jeff Corbett,
James Cryan,
Nick Hartmann,
Markus Ilchen,
Keith Jobe,
Renkai Li,
Igor Makasyuk,
Xiaozhe Shen,
Xijie Wang,
Stephen Weathersby,
Jie Yang,
Ryan Coffee
Abstract:
Currently, our general approach to retrieving molecular structures from ultrafast gas-phase diffraction heavily relies on complex ab initio electronic or vibrational excited state simulations to make conclusive interpretations. Without such simulations, inverting this measurement for the structural probability distribution is typically intractable. This creates a so-called inverse problem. In this…
▽ More
Currently, our general approach to retrieving molecular structures from ultrafast gas-phase diffraction heavily relies on complex ab initio electronic or vibrational excited state simulations to make conclusive interpretations. Without such simulations, inverting this measurement for the structural probability distribution is typically intractable. This creates a so-called inverse problem. In this work, we develop a broadly applicable method that addresses this inverse problem by approximating the molecular frame structure $|Ψ(\boldsymbol{R}, t)|^2$ distribution independent of these complex simulations. We retrieve the vibronic ground state $|Ψ(\boldsymbol{R})|^2$ for both simulated stretched NO$_2$ and measured N$_2$O. From measured N$_2$O, we observe 40 mAngstroms coordinate-space resolution from 3.75 inverse Angstroms reciprocal space range and poor signal-to-noise, a 50X improvement over traditional Fourier transform methods. In simulated NO$_2$, typical to high signal-to-noise levels predict 100--1000X resolution improvements, down to 0.1 mAngstroms. By directly measuring the width of $|Ψ(\boldsymbol{R})|^2$, we open ultrafast gas-phase diffraction capabilities to measurements beyond current analysis approaches. This method has the potential to effectively turn gas-phase ultrafast diffraction into a discovery-oriented technique to probe systems that are prohibitively difficult to simulate.
△ Less
Submitted 10 August, 2023; v1 submitted 19 July, 2022;
originally announced July 2022.
-
Picosecond Timing-Planes for Future Collider Detectors
Authors:
P. W. Gorham,
C. Campos,
C. Hast,
K. Jobe,
C. Miki,
L. Nguyen,
M. Olmedo,
R. Prechelt,
C. Sonoda,
G. S. Varner
Abstract:
We report experimental test-beam results on dielectric-loaded waveguide detectors that utilize microwave Cherenkov signals to time and characterize high energy particle showers. These results are used to validate models and produce high-fidelity simulations of timing plane systems which yield picosecond time tags and millimeter spatial coordinates for the shower centroid. These timing planes, base…
▽ More
We report experimental test-beam results on dielectric-loaded waveguide detectors that utilize microwave Cherenkov signals to time and characterize high energy particle showers. These results are used to validate models and produce high-fidelity simulations of timing plane systems which yield picosecond time tags and millimeter spatial coordinates for the shower centroid. These timing planes, based on the Askaryan effect in solid dielectrics, are most effective at the high center-of-momentum energies planned for the Future Circular Collider (FCC-hh), and are of particular interest in the forward region due to their high radiation immunity. We use our beam test results and GEANT4 simulations to validate a hybrid microwave detector model, which is used to simulate a reference timing plane design for the FCC forward calorimeters. Our results indicate that 0.5-3 ps particle timing is possible for a wide range of collision products in the reference FCC hadron collider detector, even with current technology.
△ Less
Submitted 10 February, 2022; v1 submitted 1 December, 2021;
originally announced December 2021.
-
The SLAC T-510 experiment for radio emission from particle showers: detailed simulation study and interpretation
Authors:
K. Bechtol,
K. Belov,
K. Borch,
P. Chen,
J. Clem,
P. Gorham,
C. Hast,
T. Huege,
R. Hyneman,
K. Jobe,
K. Kuwatani,
J. Lam,
T. C. Liu,
K. Mulrey,
J. Nam,
C. Naudet,
R. J. Nichol,
C. Paciaroni,
B. F. Rauch,
A. Romero-Wolf,
B. Rotter,
D. Saltzberg,
H. Schoorlemmer,
D. Seckel,
B. Strutt
, et al. (4 additional authors not shown)
Abstract:
Over the last several decades, radio detection of air showers has been widely used to detect ultra-high-energy cosmic rays. We developed an experiment under controlled laboratory conditions at SLAC with which we measured the radio-frequency radiation from a charged particle shower produced by bunches of electrons as primaries with known energy. The shower took place in a target made of High Densit…
▽ More
Over the last several decades, radio detection of air showers has been widely used to detect ultra-high-energy cosmic rays. We developed an experiment under controlled laboratory conditions at SLAC with which we measured the radio-frequency radiation from a charged particle shower produced by bunches of electrons as primaries with known energy. The shower took place in a target made of High Density Polyethylene located in a strong magnetic field. The experiment was designed so that Askaryan and magnetically-induced components of the radio emission could be measured independently. At the same time, we performed a detailed simulation of this experiment to predict the radio signal using two microscopic formalisms, endpoint and ZHS. In this paper, we present the simulation scheme and make a comparison with data characteristics such as linearity with magnetic field and amplitude. The simulations agree with the measurements within uncertainties and present a good description of the data. In particular, reflections within the target that accounted for the largest systematic uncertainties are addressed. The prediction of the amplitude of Askaryan emission agrees with measurements to within 5% for the endpoint formalism and 11% for the ZHS formalism. The amplitudes of magnetically-induced emission agree to within 5% for the endpoint formalism and less than 1% for the ZHS formalism. The agreement of the absolute scale of emission gives confidence in state-of-the-art air shower simulations which are based on the applied formalisms.
△ Less
Submitted 3 March, 2022; v1 submitted 8 November, 2021;
originally announced November 2021.
-
Picosecond timing of Microwave Cherenkov Impulses from High-Energy Particle Showers Using Dielectric-loaded Waveguides
Authors:
P. W. Gorham,
J. Bynes,
B. Fox,
C. Hast,
B. Hill,
K. Jobe,
C. Miki,
R. Prechelt,
B. Rotter,
D. P. Saltzberg,
S. A. Wissel,
G. S. Varner,
S. Zekioglu
Abstract:
We report on the first measurements of coherent microwave impulses from high-energy particle-induced electromagnetic showers generated via the Askaryan effect in a dielectric-loaded waveguide. Bunches of 12.16 GeV electrons with total bunch energy of $\sim 10^3-10^4$ GeV were pre-showered in tungsten, and then measured with WR-51 rectangular (12.6 mm by 6.3 mm) waveguide elements loaded with solid…
▽ More
We report on the first measurements of coherent microwave impulses from high-energy particle-induced electromagnetic showers generated via the Askaryan effect in a dielectric-loaded waveguide. Bunches of 12.16 GeV electrons with total bunch energy of $\sim 10^3-10^4$ GeV were pre-showered in tungsten, and then measured with WR-51 rectangular (12.6 mm by 6.3 mm) waveguide elements loaded with solid alumina ($Al_2 O_3$) bars. In the 5-8 GHz $TE_{10}$ single-mode band determined by the presence of the dielectric in the waveguide, we observed band-limited microwave impulses with amplitude proportional to bunch energy. Signals in different waveguide elements measuring the same shower were used to estimate relative time differences with 2.3 picosecond precision. These measurements establish a basis for using arrays of alumina-loaded waveguide elements, with exceptional radiation hardness, as very high precision timing planes for high-energy physics detectors.
△ Less
Submitted 25 April, 2018; v1 submitted 5 August, 2017;
originally announced August 2017.
-
Diffractive Imaging of Coherent Nuclear Motion in Isolated Molecules
Authors:
Jie Yang,
Markus Guehr,
Xiaozhe Shen,
Renkai Li,
Theodore Vecchione,
Ryan Coffee,
Jeff Corbett,
Alan Fry,
Nick Hartmann,
Carsten Hast,
Kareem Hegazy,
Keith Jobe,
Igor Makasyuk,
Joseph Robinson,
Matthew S. Robinson,
Sharon Vetter,
Stephen Weathersby,
Charles Yoneda,
Xijie Wang,
Martin Centurion
Abstract:
Observing the motion of the nuclear wavepackets during a molecular reaction, in both space and time, is crucial for understanding and controlling the outcome of photoinduced chemical reactions. We have imaged the motion of a vibrational wavepacket in isolated iodine molecules using ultrafast electron diffraction with relativistic electrons. The time-varying interatomic distance was measured with a…
▽ More
Observing the motion of the nuclear wavepackets during a molecular reaction, in both space and time, is crucial for understanding and controlling the outcome of photoinduced chemical reactions. We have imaged the motion of a vibrational wavepacket in isolated iodine molecules using ultrafast electron diffraction with relativistic electrons. The time-varying interatomic distance was measured with a precision 0.07 Å and temporal resolution of 230 fs full-width at half-maximum (FWHM). The method is not only sensitive to the position but also the shape of the nuclear wavepacket.
△ Less
Submitted 27 August, 2016;
originally announced August 2016.
-
Diffractive imaging of a molecular rotational wavepacket with femtosecond Megaelectronvolt electron pulses
Authors:
Jie Yang,
Markus Guehr,
Theodore Vecchione,
Matthew S. Robinson,
Renkai Li,
Nick Hartmann,
Xiaozhe Shen,
Ryan Coffee,
Jeff Corbett,
Alan Fry,
Kelly Gaffney,
Tais Gorkhover,
Carsten Hast,
Keith Jobe,
Igor Makasyuk,
Alexander Reid,
Joseph Robinson,
Sharon Vetter,
Fenglin Wang,
Stephen Weathersby,
Charles Yoneda,
Martin Centurion,
Xijie Wang
Abstract:
Imaging changes in molecular geometries on their natural femtosecond timescale with sub-Angstrom spatial precision is one of the critical challenges in the chemical sciences, since the nuclear geometry changes determine the molecular reactivity. For photoexcited molecules, the nuclear dynamics determine the photoenergy conversion path and efficiency. We performed a gas-phase electron diffraction e…
▽ More
Imaging changes in molecular geometries on their natural femtosecond timescale with sub-Angstrom spatial precision is one of the critical challenges in the chemical sciences, since the nuclear geometry changes determine the molecular reactivity. For photoexcited molecules, the nuclear dynamics determine the photoenergy conversion path and efficiency. We performed a gas-phase electron diffraction experiment using Megaelectronvolt (MeV) electrons, where we captured the rotational wavepacket dynamics of nonadiabatically laser-aligned nitrogen molecules. We achieved an unprecedented combination of 100 fs root-mean-squared (RMS) temporal resolution and sub-Angstrom (0.76 Å) spatial resolution that makes it possible to resolve the position of the nuclei within the molecule. In addition, the diffraction patterns reveal the angular distribution of the molecules, which changes from prolate (aligned) to oblate (anti-aligned) in 300 fs. Our results demonstrate a significant and promising step towards making atomically resolved movies of molecular reactions.
△ Less
Submitted 21 October, 2015;
originally announced October 2015.
-
Accelerator measurements of magnetically-induced radio emission from particle cascades with applications to cosmic-ray air showers
Authors:
K. Belov,
K. Mulrey,
A. Romero-Wolf,
S. A. Wissel,
A. Zilles,
K. Bechtol,
K. Borch,
P. Chen,
J. Clem,
P. W. Gorham,
C. Hast,
T. Huege,
R. Hyneman,
K. Jobe,
K. Kuwatani,
J. Lam,
T. Liu,
J. Nam,
C. Naudet,
R. Nichol,
B. F. Rauch,
B. Rotter,
D. Saltzberg,
H. Schoorlemmer,
D. Seckel
, et al. (3 additional authors not shown)
Abstract:
For fifty years, cosmic-ray air showers have been detected by their radio emission. We present the first laboratory measurements that validate electrodynamics simulations used in air shower modeling. An experiment at SLAC provides a beam test of radio-frequency (RF) radiation from charged particle cascades in the presence of a magnetic field, a model system of a cosmic-ray air shower. This experim…
▽ More
For fifty years, cosmic-ray air showers have been detected by their radio emission. We present the first laboratory measurements that validate electrodynamics simulations used in air shower modeling. An experiment at SLAC provides a beam test of radio-frequency (RF) radiation from charged particle cascades in the presence of a magnetic field, a model system of a cosmic-ray air shower. This experiment provides a suite of controlled laboratory measurements to compare to particle-level simulations of RF emission, which are relied upon in ultra-high-energy cosmic-ray air shower detection. We compare simulations to data for intensity, linearity with magnetic field, angular distribution, polarization, and spectral content. In particular, we confirm modern predictions that the magnetically induced emission in a dielectric forms a cone that peaks at the Cherenkov angle and show that the simulations reproduce the data within systematic uncertainties.
△ Less
Submitted 22 April, 2016; v1 submitted 26 July, 2015;
originally announced July 2015.
-
A Test Facility for the International Linear Collider at SLAC End Station A, for Prototypes of Beam Delivery and IR Components
Authors:
M. Woods,
R. Erickson,
J. Frisch,
C. Hast,
R. K. Jobe,
L. Keller,
T. Markiewicz,
T. Maruyama,
D. McCormick,
J. Nelson,
T. Nelson,
N. Phinney,
T. Raubenheimer,
M. Ross,
A. Seryi,
S. Smith,
Z. Szalata,
P. Tenenbaum,
M. Woodley,
D. Angal-Kalinin,
C. Beard,
C. Densham,
J. Greenhalgh,
F. Jackson,
A. Kalinin
, et al. (36 additional authors not shown)
Abstract:
The SLAC Linac can deliver damped bunches with ILC parameters for bunch charge and bunch length to End Station A. A 10Hz beam at 28.5 GeV energy can be delivered there, parasitic with PEP-II operation. We plan to use this facility to test prototype components of the Beam Delivery System and Interaction Region. We discuss our plans for this ILC Test Facility and preparations for carrying out expe…
▽ More
The SLAC Linac can deliver damped bunches with ILC parameters for bunch charge and bunch length to End Station A. A 10Hz beam at 28.5 GeV energy can be delivered there, parasitic with PEP-II operation. We plan to use this facility to test prototype components of the Beam Delivery System and Interaction Region. We discuss our plans for this ILC Test Facility and preparations for carrying out experiments related to collimator wakefields and energy spectrometers. We also plan an interaction region mockup to investigate effects from backgrounds and beam-induced electromagnetic interference.
△ Less
Submitted 24 May, 2005;
originally announced May 2005.
-
Processing Studies of X-Band Accelerator Structures at the NLCTA
Authors:
C. Adolphsen,
W. Baumgartner,
K. Jobe,
F. Le Pimpec,
R. Loewen,
D. McCormick,
M. Ross,
T. Smith,
J. W. Wang,
T. Higo
Abstract:
RF processing studies of 1.8-m X-band (11.4 GHz) traveling wave structures at the Next Linear Collider Test Accelerator (NLCTA) have revealed breakdown-related damage at gradients lower than expected from earlier tests with standing wave and shorter, lower group velocity traveling wave structures. To understand this difference, a series of structures with different group velocities and lengths a…
▽ More
RF processing studies of 1.8-m X-band (11.4 GHz) traveling wave structures at the Next Linear Collider Test Accelerator (NLCTA) have revealed breakdown-related damage at gradients lower than expected from earlier tests with standing wave and shorter, lower group velocity traveling wave structures. To understand this difference, a series of structures with different group velocities and lengths are being processed. In parallel, efforts are being made to improve processing procedures and to reduce structure contaminants and absorbed gases. This paper presents results from these studies.
△ Less
Submitted 22 August, 2001;
originally announced August 2001.
-
Design, fabrication and measurement of the first rounded damped detuned accelerator structure (RDDS1)
Authors:
J. W. Wang,
C. Adolphsen,
G. B. Bowden,
D. L. Burke,
J. Cornuelle,
V. A. Dolgashev,
W. B. Fowkes,
R. K. Jobe,
R. M. Jones,
K. Ko,
N. Kroll,
Z. Li,
R. J. Loewen,
D. McCormick,
R. H. Miller,
C. K. Ng,
C. Pearson,
T. O. Raubenhemer,
R. Reed,
M. Ross,
R. D. Ruth,
T. Smith,
G. Stupakov,
T. Higo,
Y. Funahashi
, et al. (8 additional authors not shown)
Abstract:
As a joint effort in the JLC/NLC research program, we have developed a new type of damped detuned accelerator structure with optimized round-shaped cavities (RDDS). This paper discusses some important R&D aspects of the first structure in this series (RDDS1). The design aspects covered are the cell design with sub-MHz precision, HOM detuning, coupling and dam** technique and wakefield simulati…
▽ More
As a joint effort in the JLC/NLC research program, we have developed a new type of damped detuned accelerator structure with optimized round-shaped cavities (RDDS). This paper discusses some important R&D aspects of the first structure in this series (RDDS1). The design aspects covered are the cell design with sub-MHz precision, HOM detuning, coupling and dam** technique and wakefield simulation. The fabrication issues covered are ultra-precision cell machining with micron accuracy, assembly and diffusion bonding technologies to satisfactorily meet bookshelf, straightness and cell rotational alignment requirements. The measurements described are the RF properties of single cavities and complete accelerator section, as well as wakefields from the ASSET tests at SLAC. Finally, future improvements are also discussed.
△ Less
Submitted 6 September, 2000;
originally announced September 2000.
-
RF Processing of X-band Accelerator Structures at the NLCTA
Authors:
C. Adolphsen,
W. Baumgartner,
K. Jobe,
R. Loewen,
D. McCormick,
M. Ross,
T. Smith,
J. W. Wang,
T. Higo
Abstract:
During the initial phase of operation, the linacs of the Next Linear Collider (NLC) will contain roughly 5000 X-Band accelerator structures that will accelerate beams of electrons and positrons to 250 GeV. These structures will nominally operate at an unloaded gradient of 72 MV/m. As part of the NLC R&D program, several prototype structures have been built and operated at the Next Linear Collide…
▽ More
During the initial phase of operation, the linacs of the Next Linear Collider (NLC) will contain roughly 5000 X-Band accelerator structures that will accelerate beams of electrons and positrons to 250 GeV. These structures will nominally operate at an unloaded gradient of 72 MV/m. As part of the NLC R&D program, several prototype structures have been built and operated at the Next Linear Collider Test Accelerator (NLCTA) at SLAC. Here, the effect of high gradient operation on the structure performance has been studied. Significant progress was made during the past year after the NLCTA power sources were upgraded to reliably produce the required NLC power levels and beyond. This paper describes the structures, the processing methodology and the observed effects of high gradient operation.
△ Less
Submitted 20 August, 2000;
originally announced August 2000.