-
Temporal and dosimetric beam monitoring of individual pulses in FLASH Radiotherapy using Timepix3 pixelated detector placed out-of-field
Authors:
Cristina Oancea,
Katerina Sykorova,
Jan Jakubek,
Jiri Pivec,
Felix Riemer,
Steven Worm,
Alexandra Bourgouin
Abstract:
FLASH radiotherapy necessitates the development of advanced Quality Assurance methods and detectors for accurate and online monitoring of the radiation field. This study introduces enhanced time-resolution detection systems and methods tailored for single-pulse detection. The goal of this work was to measure the delivered number of pulses, investigate temporal structure of individual pulses, and t…
▽ More
FLASH radiotherapy necessitates the development of advanced Quality Assurance methods and detectors for accurate and online monitoring of the radiation field. This study introduces enhanced time-resolution detection systems and methods tailored for single-pulse detection. The goal of this work was to measure the delivered number of pulses, investigate temporal structure of individual pulses, and to develop a method for dose-per-pulse (DPP) monitoring based on secondary radiation particles produced in the experimental room.
A 20 MeV electron beam generated from a linear accelerator (LINAC) was delivered to a water phantom. Ultra-high dose-per-pulse (UHDPP) electron beams were used with a dose per pulse ranging from 1 Gy to over 7 Gy. The pulse lengths ranged from 1.18 us to 2.88 us at a pulse rate frequency of 5 Hz. A semiconductor pixel detector Timepix3 (TPX3) was used to track direct interactions in the Silicon sensor created by single secondary particles. Measurements were performed in the air, while the detector was positioned out-of-field at a lateral distance of 200 cm parallel with the LINAC exit window. The dose deposited in the silicon was measured along with the pulse length and the nanostructure of the pulse.
Simultaneously deposited energy and time of arrival of single particles were measured with a precision of 1.56 ns. The measured pulse count agreed with the delivered values. A linear response (R^2 = 0.999) was established between the delivered beam current and the measured dose at the detector position (orders of nGy). The difference between the average measured and average delivered pulse length was 0.003(30) us.
This simple non-invasive method, exhibits no limitations on the delivered DPP within the range used during this investigation. It enhances the precision and real-time monitoring of FLASH treatment plans with nanosecond precision.
△ Less
Submitted 21 April, 2024;
originally announced April 2024.
-
Silicon Carbide Timepix3 detector for quantum-imaging detection and spectral tracking of charged particles in wide range of energy and field-of-view
Authors:
Andrej Novak,
Carlos Granja,
Andrea Sagatova,
Jan Jakubek,
Bohumir Zatko,
Vladimir Vondracek,
Michal Andrlik,
Vaclav Zach,
Stepan Polansky,
Anuj Rathi,
Cristina Oancea
Abstract:
The hybrid architecture of the Timepix (TPX) family of detectors enables the use of different semiconductor sensors, most commonly silicon (Si), as well as high-density materials such as Cadmium Telluride (CdTe) or Gallium Arsenide (GaAs). For this purpose, we explore the potential of a silicon carbide (SiC) sensor bump-bonded on a Timepix3 detector as a radiation imaging and particle tracking det…
▽ More
The hybrid architecture of the Timepix (TPX) family of detectors enables the use of different semiconductor sensors, most commonly silicon (Si), as well as high-density materials such as Cadmium Telluride (CdTe) or Gallium Arsenide (GaAs). For this purpose, we explore the potential of a silicon carbide (SiC) sensor bump-bonded on a Timepix3 detector as a radiation imaging and particle tracking detector. SiC stands as a radiation-hard material also with the ability to operate at elevated temperatures up to several hundreds of degrees Celsius. As a result, this sensor material is more suitable for radiation harsh environments compared to conventional e.g., Si sensors. In this work, we evaluate the response for precise radiation spectrometry and high-resolution particle tracking of newly developed SiC Timepix3 detector which is built and operated as a compact radiation camera MiniPIX-Timepix3 with integrated readout electronics. Calibration measurements were conducted with mono-energetic proton beams with energies of 13, 22, and 31 MeV at the U-120M cyclotron at the Nuclear Physics Institute Czech Academy of Science (NPI CAS), Prague, as well as 100 and 226 MeV at the Proton Therapy Center Czech (PTC) in Prague. High-resolution pattern recognition analysis and single-particle spectral tracking are used for detailed inspection and understanding of the sensor response. Results include distributions of deposited energy and linear energy transfer (LET) spectra. The spatial uniformity of the pixelated detector response is examined in terms of homogeneously distributed deposited energy.
△ Less
Submitted 26 October, 2023;
originally announced October 2023.
-
Stray radiation produced in FLASH electron beams characterized by the MiniPIX Timepix3 Flex detector
Authors:
C. Oancea,
C. Bălan,
J. Pivec,
C. Granja,
J. Jakubek,
D. Chvatil,
V. Olsansky,
V. Chiş
Abstract:
This work aims to characterize ultra high dose rate pulses (UHDpulse) electron beams using the hybrid semiconductor pixel detector. The Timepix3 (TPX3) ASIC chip was used to measure the composition, spatial, time, and spectral characteristics of the secondary radiation fields from pulsed 15 to 23 MeV electron beams. The challenge is to develop a single compact detector that could extract spectrome…
▽ More
This work aims to characterize ultra high dose rate pulses (UHDpulse) electron beams using the hybrid semiconductor pixel detector. The Timepix3 (TPX3) ASIC chip was used to measure the composition, spatial, time, and spectral characteristics of the secondary radiation fields from pulsed 15 to 23 MeV electron beams. The challenge is to develop a single compact detector that could extract spectrometric and dosimetric information on such high flux short pulsed fields. For secondary beam measurements, PMMA plates of 1 and 8 cm thickness were placed in front of the electron beam, with a pulse duration of 3.5 microseconds. Timepix3 detectors with silicon sensors of 100 and 500 micrometers thickness were placed on a shifting stage allowing for data acquisition at various lateral positions to the beam axis. The use of the detector in FLEXI configuration enables suitable measurements in situ and minimal self shielding. Preliminary results highlight both the technique and the detector's ability to measure individual UHDpulses of electron beams delivered in short pulses. In addition, the use of the two signal chains per pixel enables the estimation of particle flux and the scattered dose rates (DRs) at various distances from the beam core, in mixed radiation fields.
△ Less
Submitted 31 January, 2022;
originally announced January 2022.
-
Gamma Radiation Source Localization for Micro Aerial Vehicles with a Miniature Single-Detector Compton Event Camera
Authors:
Tomas Baca,
Petr Stibinger,
Daniela Doubravova,
Daniel Turecek,
Jaroslav Solc,
Jan Rusnak,
Martin Saska,
Jan Jakubek
Abstract:
A novel method for localization and estimation of compact sources of gamma radiation for Micro Aerial Vehicles (MAVs) is presented in this paper. The method is developed for a novel single-detector Compton camera, developed by the authors. The detector is extremely small and weighs only 40 g, which opens the possibility for use on sub-1 kg class of drones. The Compton camera uses the MiniPIX TPX3…
▽ More
A novel method for localization and estimation of compact sources of gamma radiation for Micro Aerial Vehicles (MAVs) is presented in this paper. The method is developed for a novel single-detector Compton camera, developed by the authors. The detector is extremely small and weighs only 40 g, which opens the possibility for use on sub-1 kg class of drones. The Compton camera uses the MiniPIX TPX3 CdTe event camera to measure Compton scattering products of incoming high-energy gamma photons. The 3D position and the sub-nanosecond time delay of the measured scattering products are used to reconstruct sets of possible directions to the source. The proposed method utilizes a filter for fusing the measurements and estimating the radiation source position during the flight. The computations are executed in real-time onboard and allow integration of the detector info into a fully-autonomous system. Moreover, the real-time nature of the estimator potentially allows estimating states of a moving radiation source. The proposed method was validated in simulations and demonstrated in a real-world experiment with a Cs137 radiation source. The approach can localize a gamma source without estimating the gradient or contours of radiation intensity, which opens possibilities for localizing sources in a cluttered and urban environment.
△ Less
Submitted 23 August, 2021; v1 submitted 6 November, 2020;
originally announced November 2020.
-
Three dimensional reconstruction of therapeutic carbon ion beams in phantoms using single secondary ion tracks
Authors:
Anna Merle Reinhart,
Claudia Katharina Spindeldreier,
Jan Jakubek,
Maria Martisikova
Abstract:
Carbon ion beam radiotherapy enables a very localised dose deposition. However, already small changes in the patient geometry or positioning errors can significantly distort the dose distribution. A live monitoring system of the beam delivery within the patient is therefore highly desirable and could improve patient treatment. We present a novel three-dimensional imaging method of the beam in the…
▽ More
Carbon ion beam radiotherapy enables a very localised dose deposition. However, already small changes in the patient geometry or positioning errors can significantly distort the dose distribution. A live monitoring system of the beam delivery within the patient is therefore highly desirable and could improve patient treatment. We present a novel three-dimensional imaging method of the beam in the irradiated object, exploiting the measured tracks of single secondary ions emerging under irradiation. The secondary particle tracks are detected with a TimePix stack, a set of parallel pixelated semiconductor detectors. We developed a three-dimensional reconstruction algorithm based on maximum likelihood expectation maximisation. We demonstrate the applicability of the new method in an irradiation of a cylindrical PMMA phantom of human head size with a carbon ion pencil beam of 226MeV/u. The beam image in the phantom is reconstructed from a set of 9 discrete detector positions between -80 and 50 degrees from the beam axis. Furthermore, we demonstrate the potential to visualise inhomogeneities by irradiating a PMMA phantom with an air gap as well as bone and adipose tissue surrogate inserts. We successfully reconstructed a 3D image of the treatment beam in the phantom from single secondary ion tracks. The beam image corresponds well to the distribution expected from the beam direction and energy. In addition, cylindrical inhomogeneities with a diameter of 2.85cm and density differences down to 0.3g/cm$^3$ to the surrounding material are clearly visualised. This novel 3D method to image a therapeutic carbon ion beam in the irradiated object does not interfere with the treatment and requires knowledge only of single secondary ion tracks. Even with detectors with only a small angular coverage, the 3D reconstruction of the fragmentation points presented in this work was found to be feasible.
△ Less
Submitted 23 May, 2017; v1 submitted 14 October, 2016;
originally announced October 2016.
-
Characterization of Thin p-on-p Radiation Detectors with Active Edges
Authors:
T. Peltola,
X. Wu,
J. Kalliopuska,
C. Granja,
J. Jakubek,
M. Jakubek,
J. Härkönen,
A. Gädda
Abstract:
Active edge p-on-p silicon pixel detectors with thickness of 100 $μ$m were fabricated on 150 mm Float zone silicon wafers at VTT. By combining measured results and TCAD simulations, a detailed study of electric field distributions and charge collection performances as a function of applied voltage in a p-on-p detector was carried out. A comparison with the results of a more conventional active edg…
▽ More
Active edge p-on-p silicon pixel detectors with thickness of 100 $μ$m were fabricated on 150 mm Float zone silicon wafers at VTT. By combining measured results and TCAD simulations, a detailed study of electric field distributions and charge collection performances as a function of applied voltage in a p-on-p detector was carried out. A comparison with the results of a more conventional active edge p-on-n pixel sensor is presented. The results from 3D spatial map** show that at pixel-to-edge distances less than 100 $μ$m the sensitive volume is extended to the physical edge of the detector when the applied voltage is above full depletion. The results from a spectroscopic measurement demonstrate a good functionality of the edge pixels. The interpixel isolation above full depletion and the breakdown voltage were found to be equal to the p-on-n sensor while lower charge collection was observed in the p-on-p pixel sensor below 80 V. Simulations indicated this to be partly a result of a more favourable weighting field in the p-on-n sensor and partly of lower hole lifetimes in the p-bulk.
△ Less
Submitted 21 January, 2016; v1 submitted 6 January, 2016;
originally announced January 2016.
-
The Physics Programme Of The MoEDAL Experiment At The LHC
Authors:
B. Acharya,
J. Alexandre,
J. Bernabéu,
M. Campbell,
S. Cecchini,
J. Chwastowski,
M. De Montigny,
D. Derendarz,
A. De Roeck,
J. R. Ellis,
M. Fairbairn,
D. Felea,
M. Frank,
D. Frekers,
C. Garcia,
G. Giacomelli,
M. Giorgini,
D. HaŞegan,
T. Hott,
J. Jakůbek,
A. Katre,
D-W Kim,
M. G. L. King,
K. Kinoshita,
D. Lacarrere
, et al. (37 additional authors not shown)
Abstract:
The MoEDAL experiment at Point 8 of the LHC ring is the seventh and newest LHC experiment. It is dedicated to the search for highly ionizing particle avatars of physics beyond the Standard Model, extending significantly the discovery horizon of the LHC. A MoEDAL discovery would have revolutionary implications for our fundamental understanding of the Microcosm. MoEDAL is an unconventional and large…
▽ More
The MoEDAL experiment at Point 8 of the LHC ring is the seventh and newest LHC experiment. It is dedicated to the search for highly ionizing particle avatars of physics beyond the Standard Model, extending significantly the discovery horizon of the LHC. A MoEDAL discovery would have revolutionary implications for our fundamental understanding of the Microcosm. MoEDAL is an unconventional and largely passive LHC detector comprised of the largest array of Nuclear Track Detector stacks ever deployed at an accelerator, surrounding the intersection region at Point 8 on the LHC ring. Another novel feature is the use of paramagnetic trap** volumes to capture both electrically and magnetically charged highly-ionizing particles predicted in new physics scenarios. It includes an array of TimePix pixel devices for monitoring highly-ionizing particle backgrounds. The main passive elements of the MoEDAL detector do not require a trigger system, electronic readout, or online computerized data acquisition. The aim of this paper is to give an overview of the MoEDAL physics reach, which is largely complementary to the programs of the large multi-purpose LHC detectors ATLAS and CMS.
△ Less
Submitted 28 August, 2014; v1 submitted 29 May, 2014;
originally announced May 2014.
-
Ultra-stable implanted 83Rb/83mKr electron sources for the energy scale monitoring in the KATRIN experiment
Authors:
M. Zbořil,
S. Bauer,
M. Beck,
J. Bonn,
O. Dragoun,
J. Jakůbek,
K. Johnston,
A. Kovalík,
E. W. Otten,
K. Schlösser,
M. Slezák,
A. Špalek,
T. Thümmler,
D. Vénos,
J. Žemlička,
C. Weinheimer
Abstract:
The KATRIN experiment aims at the direct model-independent determination of the average electron neutrino mass via the measurement of the endpoint region of the tritium beta decay spectrum. The electron spectrometer of the MAC-E filter type is used, requiring very high stability of the electric filtering potential. This work proves the feasibility of implanted 83Rb/83mKr calibration electron sourc…
▽ More
The KATRIN experiment aims at the direct model-independent determination of the average electron neutrino mass via the measurement of the endpoint region of the tritium beta decay spectrum. The electron spectrometer of the MAC-E filter type is used, requiring very high stability of the electric filtering potential. This work proves the feasibility of implanted 83Rb/83mKr calibration electron sources which will be utilised in the additional monitor spectrometer sharing the high voltage with the main spectrometer of KATRIN. The source employs conversion electrons of 83mKr which is continuously generated by 83Rb. The K-32 conversion line (kinetic energy of 17.8 keV, natural line width of 2.7 eV) is shown to fulfill the KATRIN requirement of the relative energy stability of +/-1.6 ppm/month. The sources will serve as a standard tool for continuous monitoring of KATRIN's energy scale stability with sub-ppm precision. They may also be used in other applications where the precise conversion lines can be separated from the low energy spectrum caused by the electron inelastic scattering in the substrate.
△ Less
Submitted 5 February, 2013; v1 submitted 20 December, 2012;
originally announced December 2012.
-
Expected Performance of the ATLAS Experiment - Detector, Trigger and Physics
Authors:
The ATLAS Collaboration,
G. Aad,
E. Abat,
B. Abbott,
J. Abdallah,
A. A. Abdelalim,
A. Abdesselam,
O. Abdinov,
B. Abi,
M. Abolins,
H. Abramowicz,
B. S. Acharya,
D. L. Adams,
T. N. Addy,
C. Adorisio,
P. Adragna,
T. Adye,
J. A. Aguilar-Saavedra,
M. Aharrouche,
S. P. Ahlen,
F. Ahles,
A. Ahmad,
H. Ahmed,
G. Aielli,
T. Akdogan
, et al. (2587 additional authors not shown)
Abstract:
A detailed study is presented of the expected performance of the ATLAS detector. The reconstruction of tracks, leptons, photons, missing energy and jets is investigated, together with the performance of b-tagging and the trigger. The physics potential for a variety of interesting physics processes, within the Standard Model and beyond, is examined. The study comprises a series of notes based on…
▽ More
A detailed study is presented of the expected performance of the ATLAS detector. The reconstruction of tracks, leptons, photons, missing energy and jets is investigated, together with the performance of b-tagging and the trigger. The physics potential for a variety of interesting physics processes, within the Standard Model and beyond, is examined. The study comprises a series of notes based on simulations of the detector and physics processes, with particular emphasis given to the data expected from the first years of operation of the LHC at CERN.
△ Less
Submitted 14 August, 2009; v1 submitted 28 December, 2008;
originally announced January 2009.
-
Distribution of the 83Rb/83mKr activity on vacuum evaporated samples examined with the Timepix position sensitive detector
Authors:
D. Venos,
J. Jakubek,
O. Dragoun,
S. Pospisil
Abstract:
Properties of vacuum evaporated 83Rb/83mKr sources of low-energy conversion electrons, which are under development for monitoring the energy scale stability of the Karlsruhe Tritium Neutrino experiment KATRIN, were examined by the Timepix pixel detector exhibiting the position resolution of at least 55 microm. No distinct local inhomogeneities in the surface distribution of 83Rb/83mKr were obser…
▽ More
Properties of vacuum evaporated 83Rb/83mKr sources of low-energy conversion electrons, which are under development for monitoring the energy scale stability of the Karlsruhe Tritium Neutrino experiment KATRIN, were examined by the Timepix pixel detector exhibiting the position resolution of at least 55 microm. No distinct local inhomogeneities in the surface distribution of 83Rb/83mKr were observed. The source diameter derived from the recorded image agrees within 5 % with that expected from evaporation geometry. More precise determination of the actual source diameter is complicated by Compton scattered electrons caused by 83Rb gamma-rays.
△ Less
Submitted 22 December, 2007;
originally announced December 2007.