-
Towards accurate real-time luminescence thermometry: an automated machine learning approach
Authors:
Emanuel P. Santos,
Roberta S. Pugina,
Eloísa G. Hilário,
Alyson J. A. Carvalho,
Carlos Jacinto,
Francisco A. M. G. Rego-Filho,
Askery Canabarro,
Anderson S. L. Gomes,
José Maurício A. Caiut,
André L. Moura
Abstract:
Luminescence thermometry has been extensively exploited in the last decades both from the fundamental and applied point of views. The application of photoluminescent nanoparticles on the microscopic level based on rare-earth doped (RED) nanostructures is yet a challenge. Distinct underlying physical mechanisms in the RED nanomaterials have been exploited, such as intensity ratio between radiative…
▽ More
Luminescence thermometry has been extensively exploited in the last decades both from the fundamental and applied point of views. The application of photoluminescent nanoparticles on the microscopic level based on rare-earth doped (RED) nanostructures is yet a challenge. Distinct underlying physical mechanisms in the RED nanomaterials have been exploited, such as intensity ratio between radiative transitions associated with thermally coupled energy levels, energy peak and lifetime of an excited state variations with the temperature. The drawbacks of such systems are the relatively low thermal sensitivity (Sr), and the large temperature uncertainty. To overcome that, several research groups have been seeking new functionalized materials. The majority of the efforts have been directed towards increasing Sr with record around 10 %°C-1, which is, however, considered unsatisfactory. We propose the use of an automated machine learning tool to retrieve an ideal pipeline improving the response of photoluminescence thermometers. As a proof-of-concept, we used Nd3+-doped YAG nanoparticles, excited at 760 nm, and the photoluminescence spectra in the range from 860 nm to 960 nm as input parameters. In addition to the improvement in the accuracy (> 5.5x over traditional methods), the implementation is very simple, without the requirement of any deconvolution procedure or knowledge of any underlying physical mechanism. Our findings demonstrate that this approach is resilient to natural variances across various spectral acquisitions, which may otherwise lead to an inaccurate estimation of temperature, opening the door for real-time applications. Our open-source code is designed to be accessible to individuals without programming experience.
△ Less
Submitted 22 June, 2023;
originally announced July 2023.
-
Metallic nanoparticles-decorated NdxY1-xAl3(BO3)4 sub-micrometric particles to enhance anti-Stokes excitation performance
Authors:
Eloísa G. Hilário,
Tatiana Habib,
Célio V. T. Maciel,
Rodrigo F. da Silva,
Daniel F. Luz,
Gabriela S. Soares,
Bruno Caillier,
Carlos Jacinto,
Lauro J. Q. Maia,
José Maurício A. Caiut,
André L. Moura
Abstract:
In the anti-Stokes excitation of trivalent rare-earth ions (RE3+), the excitation photons energy is smaller than that of a given absorption transition, and the energy mismatch can be compensated by phonons annihilation from the host lattice. Since the phonon occupation number increases with temperature, heating the system generally increases the efficiency of anti-Stokes excitation. Here, we explo…
▽ More
In the anti-Stokes excitation of trivalent rare-earth ions (RE3+), the excitation photons energy is smaller than that of a given absorption transition, and the energy mismatch can be compensated by phonons annihilation from the host lattice. Since the phonon occupation number increases with temperature, heating the system generally increases the efficiency of anti-Stokes excitation. Here, we exploited the intrinsic heating associated with light-to-heat conversion in the interaction of excitation laser light with metallic nanoparticles (Ag or Au) on the surface of submicrometric particles of NdxY1.00-xAl3(BO3)4 (x = 0.10, 0.20, and 1.00) in order to enhance the efficiency of the anti-Stokes excitation at 1064 nm. Several upconversion emissions are observed from 600 nm to 880 nm, the most intense being at 750 nm due to the Nd3+ transition {4F7/2, 4S3/2} - 4I9/2. Giant enhancements are demonstrated, when compared to undecorated NdxY1.00-xAl3(BO3)4 particles. The present results can be expanded to other luminescent materials as well as excitation wavelengths.
△ Less
Submitted 20 June, 2023;
originally announced June 2023.
-
Energy-loo** and photon-avalanche-like phenomena in NdxY1.00-xAl3(BO3)4 powders excited at 1064 nm
Authors:
Rodrigo F. da Silva,
Daniel F. Luz,
Célio V. T. Maciel,
Emanuel P. Santos,
Gabriela Soares,
Lauro J. Q. Maia,
Carlos Jacinto,
André L. Moura
Abstract:
We investigate the role of the Nd3+ content on the PA characteristics in NdxY1.00-xAl3(BO3)4 particles with x ranging from 0.05 to 1.00. It is known that the replacement of Y3 by Nd3+ into the YAl3(BO3)4 crystalline structure can introduce strong modifications of the lattice properties as well as in the photoluminescence characteristics, such as luminescence concentration quenching and broadening…
▽ More
We investigate the role of the Nd3+ content on the PA characteristics in NdxY1.00-xAl3(BO3)4 particles with x ranging from 0.05 to 1.00. It is known that the replacement of Y3 by Nd3+ into the YAl3(BO3)4 crystalline structure can introduce strong modifications of the lattice properties as well as in the photoluminescence characteristics, such as luminescence concentration quenching and broadening of spectral lines. Despite that, we observe, for low x (<= 0.20) an energy-loo** preceding the PA-like that ensues for x >= 0.40. It is associated to the proximity among the Nd3+ ions, fundamental to the electric dipole-electric dipole interaction responsible for the Nd3+ energy transfer [4F3/2, 4I9/2] - [4I15/2, 4I15/2]. We discuss the present results focusing on emerging technologies with development of ultra-sensitive thermal sensors, and super-resolution imaging thanks to the giant nonlinearities in the input-output power dependences.
△ Less
Submitted 28 November, 2022;
originally announced November 2022.
-
Raman-acoustofluidic integrated system for single-cell analysis
Authors:
Harrisson D. A. Santos,
Amanda E. Silva,
Giclênio C. Silva,
Everton B. Lima,
Alisson S. Marques,
Magna S. Alexandre-Moreira,
Aline C. Queiroz,
Carlos Jacinto,
J. Henrique Lopes,
Ueslen Rocha,
Glauber T. Silva
Abstract:
Confocal Raman microscopy offers a particular pathway for monitoring chemical "fingerprints" of intracellular components like the cell membrane, organelles, and nucleus. Nevertheless, conventional Raman acquisitions of fixed or randomly dispersed cells on a substrate, such as a microscope slide, might be severely limited for biomedical investigations. Backscattered Raman signal is likely to be ove…
▽ More
Confocal Raman microscopy offers a particular pathway for monitoring chemical "fingerprints" of intracellular components like the cell membrane, organelles, and nucleus. Nevertheless, conventional Raman acquisitions of fixed or randomly dispersed cells on a substrate, such as a microscope slide, might be severely limited for biomedical investigations. Backscattered Raman signal is likely to be overshadowed by contributions from substrate fluorescence. Also, biological assays for drug discovery, infection, and tissue engineering may require monitoring live cells individually over a time interval spanning from a few hours to a few days. To meet the needs of cell assay monitoring, we propose an acoustofluidic device that forms a levitating cell aggregation (one layer) in a cylindrical chamber of 10 μL volume that operates at 1 MHz frequency. The integrated system comprises a lab-on-a-chip device and a confocal Raman microscope. In this setup, a cell can be selectively Raman-investigated with micrometre accuracy, without any substrate interference. Based on a set of carefully designed experiments, we demonstrate that polystyrene microparticles are assembled and held standstill, enabling a full Raman spectrum to be taken of a single particle in less than a minute. The signal-to-background ratio is improved by a thousandfold when compared with conventional Raman acquisition. The Raman-acoustofluidic system is showcased for obtaining the spectrum of a single cell among an enriched population of macrophages of mice. The obtained results confirm the method's robustness for applications in single-cell analysis.
△ Less
Submitted 15 November, 2020;
originally announced November 2020.