-
Orders of Magnitude Improved Cyclotron-Mode Cooling for Non-Destructive Spin Quantum Transition Spectroscopy with Single Trapped Antiprotons
Authors:
B. M. Latacz,
M. Fleck,
J. I. Jaeger,
G. Umbrazunas,
B. P. Arndt,
S. R. Erlewein,
E. J. Wursten,
J. A. Devlin,
P. Micke,
F. Abbass,
D. Schweitzer,
M. Wiesinger,
C. Will,
H. Yildiz,
K. Blaum,
Y. Matsuda,
A. Mooser,
C. Ospelkaus,
A. Soter,
W. Quint,
J. Walz,
Y. Yamazaki,
C. Smorra,
S. Ulmer
Abstract:
We demonstrate efficient sub-thermal cooling of the modified cyclotron mode of a single trapped antiproton and reach particle temperatures $T_+=E_+/k_\text{B}$ below $200\,$mK in preparation times shorter than $500\,$s. This corresponds to the fastest resistive single-particle cyclotron cooling to sub-thermal temperatures ever demonstrated. By cooling trapped particles to such low energies, we dem…
▽ More
We demonstrate efficient sub-thermal cooling of the modified cyclotron mode of a single trapped antiproton and reach particle temperatures $T_+=E_+/k_\text{B}$ below $200\,$mK in preparation times shorter than $500\,$s. This corresponds to the fastest resistive single-particle cyclotron cooling to sub-thermal temperatures ever demonstrated. By cooling trapped particles to such low energies, we demonstrate the detection of antiproton spin transitions with an error-rate $<0.000025$, more than three orders of magnitude better than in previous best experiments. This method will have enormous impact on multi-Penning-trap experiments that measure magnetic moments with single nuclear spins for tests of matter/antimatter symmetry, high-precision mass-spectrometry, and measurements of electron $g$-factors bound to highly-charged ions that test quantum electrodynamics.
△ Less
Submitted 11 April, 2024;
originally announced April 2024.
-
Image-current mediated sympathetic laser cooling of a single proton in a Penning trap down to 170 mK axial temperature
Authors:
C. Will,
M. Wiesinger,
P. Micke,
H. Yildiz,
T. Driscoll,
S. Kommu,
F. Abbass,
B. P. Arndt,
B. B. Bauer,
S. Erlewein,
M. Fleck,
J. I. Jäger,
B. M. Latacz,
A. Mooser,
D. Schweitzer,
G. Umbrazunas,
E. Wursten,
K. Blaum,
J. A. Devlin,
C. Ospelkaus,
W. Quint,
A. Soter,
J. Walz,
C. Smorra,
S. Ulmer
Abstract:
We demonstrate a new temperature record for image-current mediated sympathetic cooling of a single proton in a cryogenic Penning trap by laser-cooled $^9$Be$^+$. An axial mode temperature of 170 mK is reached, which is a 15-fold improvement compared to the previous best value. Our cooling technique is applicable to any charged particle, so that the measurements presented here constitute a mileston…
▽ More
We demonstrate a new temperature record for image-current mediated sympathetic cooling of a single proton in a cryogenic Penning trap by laser-cooled $^9$Be$^+$. An axial mode temperature of 170 mK is reached, which is a 15-fold improvement compared to the previous best value. Our cooling technique is applicable to any charged particle, so that the measurements presented here constitute a milestone towards the next generation of high-precision Penning-trap measurements with exotic particles.
△ Less
Submitted 16 October, 2023;
originally announced October 2023.
-
Dissociative Recombination of Rotationally Cold OH$^+$ and Its Implications for the Cosmic Ray Ionization Rate in Diffuse Clouds
Authors:
Ábel Kálosi,
Lisa Gamer,
Manfred Grieser,
Robert von Hahn,
Leonard W. Isberner,
Julia I. Jäger,
Holger Kreckel,
David A. Neufeld,
Daniel Paul,
Daniel W. Savin,
Stefan Schippers,
Viviane C. Schmidt,
Andreas Wolf,
Mark G. Wolfire,
Oldřich Novotný
Abstract:
Observations of OH$^+$ are used to infer the interstellar cosmic ray ionization rate in diffuse atomic clouds, thereby constraining the propagation of cosmic rays through and the shielding by interstellar clouds, as well as the low energy cosmic ray spectrum. In regions where the H$_2$ to H number density ratio is low, dissociative recombination (DR) is the dominant destruction process for OH$^+$…
▽ More
Observations of OH$^+$ are used to infer the interstellar cosmic ray ionization rate in diffuse atomic clouds, thereby constraining the propagation of cosmic rays through and the shielding by interstellar clouds, as well as the low energy cosmic ray spectrum. In regions where the H$_2$ to H number density ratio is low, dissociative recombination (DR) is the dominant destruction process for OH$^+$ and the DR rate coefficient is important for predicting the OH$^+$ abundance and inferring the cosmic ray ionization rate. We have experimentally studied DR of electronically and vibrationally relaxed OH$^+$ in its lowest rotational levels, using an electron--ion merged-beams setup at the Cryogenic Storage Ring. From these measurements, we have derived a kinetic temperature rate coefficient applicable to diffuse cloud chemical models, i.e., for OH$^+$ in its electronic, vibrational, and rotational ground level. At typical diffuse cloud temperatures, our kinetic temperature rate coefficient is a factor of $\sim 5$ times larger than the previous experimentally derived value and a factor of $\sim 33$ times larger than the value calculated by theory. Our combined experimental and modelling results point to a significant increase for the cosmic ray ionization rate inferred from observations of OH$^+$ and H$_2$O$^+$, corresponding to a geometric mean of $(6.6 \pm 1.0) \times 10^{-16}\,\mathrm{s}^{-1}$, which is more than a factor of two larger than the previously inferred values of the cosmic ray ionization rate in diffuse atomic clouds. Combined with observations of diffuse and dense molecular clouds, these findings indicate a greater degree of cosmic ray shielding in interstellar clouds than has been previously inferred.
△ Less
Submitted 29 September, 2023;
originally announced September 2023.
-
Ultra thin polymer foil cryogenic window for antiproton deceleration and storage
Authors:
B. M. Latacz,
B. P. Arndt,
J. A. Devlin,
S. R. Erlewein,
M. Fleck,
J. I. Jäger,
P. Micke,
G. Umbrazunas,
E. Wursten,
F. Abbass,
D. Schweitzer,
M. Wiesinger,
C. Will,
H. Yildiz,
K. Blaum,
Y. Matsuda,
A. Mooser,
C. Ospelkaus,
C. Smorra,
A. Sótér,
W. Quint,
J. Walz,
Y. Yamazaki,
S. Ulmer
Abstract:
We present the design and characterisation of a cryogenic window based on an ultra-thin aluminised PET foil at T < 10K, which can withstand a pressure difference larger than 1bar at a leak rate < $1\times 10^{-9}$ mbar$\cdot$ l/s. Its thickness of approximately 1.7 $μ$m makes it transparent to various types of particles over a broad energy range. To optimise the transfer of 100keV antiprotons thro…
▽ More
We present the design and characterisation of a cryogenic window based on an ultra-thin aluminised PET foil at T < 10K, which can withstand a pressure difference larger than 1bar at a leak rate < $1\times 10^{-9}$ mbar$\cdot$ l/s. Its thickness of approximately 1.7 $μ$m makes it transparent to various types of particles over a broad energy range. To optimise the transfer of 100keV antiprotons through the window, we tested the degrading properties of different aluminium coated PET foils of thicknesses between 900nm and 2160nm, concluding that 1760nm foil decelerates antiprotons to an average energy of 5 keV. We have also explicitly studied the permeation as a function of coating thickness and temperature, and have performed extensive thermal and mechanical endurance and stress tests. Our final design integrated into the experiment has an effective open surface consisting of 7 holes with 1 mm diameter and will transmit up to 2.5% of the injected 100keV antiproton beam delivered by the AD/ELENA-facility of CERN.
△ Less
Submitted 24 August, 2023;
originally announced August 2023.
-
Trap-integrated fluorescence detection based on silicon photomultipliers in a cryogenic Penning trap
Authors:
Markus Wiesinger,
Florian Stuhlmann,
Matthew A. Bohman,
Peter Micke,
Christian Will,
Hüseyin Yildiz,
Fatma Abbass,
Bela P. Arndt,
Jack A. Devlin,
Stefan Erlewein,
Markus Fleck,
Julia I. Jäger,
Barbara M. Latacz,
Daniel Schweitzer,
Gilbertas Umbrazunas,
Elise Wursten,
Klaus Blaum,
Yasuyuki Matsuda,
Andreas Mooser,
Wolfgang Quint,
Anna Soter,
Jochen Walz,
Christian Smorra,
Stefan Ulmer
Abstract:
We present a fluorescence-detection system for laser-cooled 9Be+ ions based on silicon photomultipliers (SiPM) operated at 4 K and integrated into our cryogenic 1.9 T multi-Penning-trap system. Our approach enables fluorescence detection in a hermetically-sealed cryogenic Penning-trap chamber with limited optical access, where state-of-the-art detection using a telescope and photomultipliers at ro…
▽ More
We present a fluorescence-detection system for laser-cooled 9Be+ ions based on silicon photomultipliers (SiPM) operated at 4 K and integrated into our cryogenic 1.9 T multi-Penning-trap system. Our approach enables fluorescence detection in a hermetically-sealed cryogenic Penning-trap chamber with limited optical access, where state-of-the-art detection using a telescope and photomultipliers at room temperature would be extremely difficult. We characterize the properties of the SiPM in a cryocooler at 4 K, where we measure a dark count rate below 1/s and a detection efficiency of 2.5(3) %. We further discuss the design of our cryogenic fluorescence-detection trap, and analyze the performance of our detection system by fluorescence spectroscopy of 9Be+ ion clouds during several runs of our experiment.
△ Less
Submitted 4 August, 2023;
originally announced August 2023.
-
BASE-STEP: A transportable antiproton reservoir for fundamental interaction studies
Authors:
C. Smorra,
F. Abbass,
M. Bohman,
Y. Dutheil,
A. Hobl,
D. Popper,
B. Arndt,
B. B. Bauer,
J. A. Devlin,
S. Erlewein,
M. Fleck,
J. I. Jäger,
B. M. Latacz,
P. Micke,
M. Schiffelholz,
G. Umbrazunas,
M. Wiesinger,
C. Will,
E. Wursten,
H. Yildiz,
K. Blaum,
Y. Matsuda,
A. Mooser,
C. Ospelkaus,
W. Quint
, et al. (4 additional authors not shown)
Abstract:
Currently, the only worldwide source of low-energy antiprotons is the AD/ELENA facility located at CERN. To date, all precision measurements on single antiprotons have been conducted at this facility and provide stringent tests of the fundamental interactions and their symmetries. However, the magnetic field fluctuations from the facility operation limit the precision of upcoming measurements. To…
▽ More
Currently, the only worldwide source of low-energy antiprotons is the AD/ELENA facility located at CERN. To date, all precision measurements on single antiprotons have been conducted at this facility and provide stringent tests of the fundamental interactions and their symmetries. However, the magnetic field fluctuations from the facility operation limit the precision of upcoming measurements. To overcome this limitation, we have designed the transportable antiproton trap system BASE-STEP to relocate antiprotons to laboratories with a calm magnetic environment. We anticipate that the transportable antiproton trap will facilitate enhanced tests of CPT invariance with antiprotons, and provide new experimental possibilities of using transported antiprotons and other accelerator-produced exotic ions. We present here the technical design of the transportable trap system. This includes the transportable superconducting magnet, the cryogenic inlay consisting of the trap stack and the detection systems, and the differential pum** section to suppress the residual gas flow into the cryogenic trap chamber.
△ Less
Submitted 19 April, 2023;
originally announced April 2023.
-
Testing CPT Invariance by High-Precision Comparisons of Fundamental Properties of Protons and Antiprotons at BASE
Authors:
E. J. Wursten,
M. J. Borchert,
J. A. Devlin,
S. R. Erlewein,
M. Fleck,
J. A. Harrington,
J. I. Jäger,
B. M. Latacz,
P. Micke,
G. Umbrazunas,
F. Abbass,
M. Bohman,
S. Kommu,
D. Popper,
M. Wiesinger,
C. Will,
H. Yildiz,
K. Blaum,
Y. Matsuda,
A. Mooser,
C. Ospelkaus,
A. Soter,
W. Quint,
J. Walz,
Y. Yamazaki
, et al. (2 additional authors not shown)
Abstract:
The BASE collaboration at the Antiproton Decelerator facility of CERN compares the fundamental properties of protons and antiprotons using advanced Penning-trap systems. In previous measurement campaigns, we measured the magnetic moments of the proton and the antiproton, reaching (sub-)parts-in-a-billion fractional uncertainty. In the latest campaign, we have compared the proton and antiproton cha…
▽ More
The BASE collaboration at the Antiproton Decelerator facility of CERN compares the fundamental properties of protons and antiprotons using advanced Penning-trap systems. In previous measurement campaigns, we measured the magnetic moments of the proton and the antiproton, reaching (sub-)parts-in-a-billion fractional uncertainty. In the latest campaign, we have compared the proton and antiproton charge-to-mass ratios with a fractional uncertainty of 16 parts in a trillion. In this contribution, we give an overview of the measurement campaign, and detail how its results are used to constrain nine spin-independent coefficients of the Standard-Model Extension in the proton and electron sector.
△ Less
Submitted 1 February, 2023;
originally announced February 2023.