-
Systematic effects on a Compton polarimeter at the focus of an X-ray mirror
Authors:
M. Aoyagi,
R. G. Bose,
S. Chun,
E. Gau,
K. Hu,
K. Ishiwata,
N. K. Iyer,
F. Kislat,
M. Kiss,
K. Klepper,
H. Krawczynski,
L. Lisalda,
Y. Maeda,
F. af Malmborg,
H. Matsumoto,
A. Miyamoto,
T. Miyazawa,
M. Pearce,
B. F. Rauch,
N. Rodriguez Cavero,
S. Spooner,
H. Takahashi,
Y. Uchida,
A. T. West,
K. Wimalasena
, et al. (1 additional authors not shown)
Abstract:
XL-Calibur is a balloon-borne Compton polarimeter for X-rays in the $\sim$15-80 keV range. Using an X-ray mirror with a 12 m focal length for collecting photons onto a beryllium scattering rod surrounded by CZT detectors, a minimum-detectable polarization as low as $\sim$3% is expected during a 24-hour on-target observation of a 1 Crab source at 45$^{\circ}$ elevation. Systematic effects alter the…
▽ More
XL-Calibur is a balloon-borne Compton polarimeter for X-rays in the $\sim$15-80 keV range. Using an X-ray mirror with a 12 m focal length for collecting photons onto a beryllium scattering rod surrounded by CZT detectors, a minimum-detectable polarization as low as $\sim$3% is expected during a 24-hour on-target observation of a 1 Crab source at 45$^{\circ}$ elevation. Systematic effects alter the reconstructed polarization as the mirror focal spot moves across the beryllium scatterer, due to pointing offsets, mechanical misalignment or deformation of the carbon-fiber truss supporting the mirror and the polarimeter. Unaddressed, this can give rise to a spurious polarization signal for an unpolarized flux, or a change in reconstructed polarization fraction and angle for a polarized flux. Using bench-marked Monte-Carlo simulations and an accurate mirror point-spread function characterized at synchrotron beam-lines, systematic effects are quantified, and mitigation strategies discussed. By recalculating the scattering site for a shifted beam, systematic errors can be reduced from several tens of percent to the few-percent level for any shift within the scattering element. The treatment of these systematic effects will be important for any polarimetric instrument where a focused X-ray beam is im**ing on a scattering element surrounded by counting detectors.
△ Less
Submitted 23 February, 2024;
originally announced February 2024.
-
The design and performance of the XL-Calibur anticoincidence shield
Authors:
N. K. Iyer,
M. Kiss,
M. Pearce,
T. -A. Stana,
H. Awaki,
R. G. Bose,
A. Dasgupta,
G. De Geronimo,
E. Gau,
T. Hakamata,
M. Ishida,
K. Ishiwata,
W. Kamogawa,
F. Kislat,
T. Kitaguchi,
H. Krawczynski,
L. Lisalda,
Y. Maeda,
H. Matsumoto,
A. Miyamoto,
T. Miyazawa,
T. Mizuno,
B. F. Rauch,
N. Rodriguez Cavero,
N. Sakamoto
, et al. (9 additional authors not shown)
Abstract:
The XL-Calibur balloon-borne hard X-ray polarimetry mission comprises a Compton-scattering polarimeter placed at the focal point of an X-ray mirror. The polarimeter is housed within a BGO anticoincidence shield, which is needed to mitigate the considerable background radiation present at the observation altitude of ~40 km. This paper details the design, construction and testing of the anticoincide…
▽ More
The XL-Calibur balloon-borne hard X-ray polarimetry mission comprises a Compton-scattering polarimeter placed at the focal point of an X-ray mirror. The polarimeter is housed within a BGO anticoincidence shield, which is needed to mitigate the considerable background radiation present at the observation altitude of ~40 km. This paper details the design, construction and testing of the anticoincidence shield, as well as the performance measured during the week-long maiden flight from Esrange Space Centre to the Canadian Northwest Territories in July 2022. The in-flight performance of the shield followed design expectations, with a veto threshold <100 keV and a measured background rate of ~0.5 Hz (20-40 keV). This is compatible with the scientific goals of the mission, where %-level minimum detectable polarisation is sought for a Hz-level source rate.
△ Less
Submitted 8 December, 2022;
originally announced December 2022.
-
Performance of the X-Calibur Hard X-Ray Polarimetry Mission during its 2018/19 Long-Duration Balloon Flight
Authors:
Quincy Abarr,
Banafsheh Beheshtipour,
Matthias Beilicke,
Richard Bose,
Dana Braun,
Gianluigi de Geronimo,
Paul Dowkontt,
Manel Errando,
Thomas Gadson,
Victor Guarino,
Scott Heatwole,
Md. Arman Hossen,
Nirmal K. Iyer,
Fabian Kislat,
Mózsi Kiss,
Takao Kitaguchi,
Henric Krawczynski,
R. James Lanzi,
Shaorui Li,
Lindsey Lisalda,
Takashi Okajima,
Mark Pearce,
Zachary Peterson,
Logan Press,
Brian Rauch
, et al. (6 additional authors not shown)
Abstract:
X-Calibur is a balloon-borne telescope that measures the polarization of high-energy X-rays in the 15--50keV energy range. The instrument makes use of the fact that X-rays scatter preferentially perpendicular to the polarization direction. A beryllium scattering element surrounded by pixellated CZT detectors is located at the focal point of the InFOCμS hard X-ray mirror. The instrument was launche…
▽ More
X-Calibur is a balloon-borne telescope that measures the polarization of high-energy X-rays in the 15--50keV energy range. The instrument makes use of the fact that X-rays scatter preferentially perpendicular to the polarization direction. A beryllium scattering element surrounded by pixellated CZT detectors is located at the focal point of the InFOCμS hard X-ray mirror. The instrument was launched for a long-duration balloon (LDB) flight from McMurdo (Antarctica) on December 29, 2018, and obtained the first constraints of the hard X-ray polarization of an accretion-powered pulsar. Here, we describe the characterization and calibration of the instrument on the ground and its performance during the flight, as well as simulations of particle backgrounds and a comparison to measured rates. The pointing system and polarimeter achieved the excellent projected performance. The energy detection threshold for the anticoincidence system was found to be higher than expected and it exhibited unanticipated dead time. Both issues will be remedied for future flights. Overall, the mission performance was nominal, and results will inform the design of the follow-up mission XL-Calibur, which is scheduled to be launched in summer 2022.
△ Less
Submitted 20 April, 2022;
originally announced April 2022.
-
XL-Calibur -- a second-generation balloon-borne hard X-ray polarimetry mission
Authors:
Q. Abarr,
H. Awaki,
M. G. Baring,
R. Bose,
G. De Geronimo,
P. Dowkontt,
M. Errando,
V. Guarino,
K. Hattori,
K. Hayashida,
F. Imazato,
M. Ishida,
N. K. Iyer,
F. Kislat,
M. Kiss,
T. Kitaguchi,
H. Krawczynski,
L. Lisalda,
H. Matake,
Y. Maeda,
H. Matsumoto,
T. Mineta,
T. Miyazawa,
T. Mizuno,
T. Okajima
, et al. (16 additional authors not shown)
Abstract:
XL-Calibur is a hard X-ray (15-80 keV) polarimetry mission operating from a stabilised balloon-borne platform in the stratosphere. It builds on heritage from the X-Calibur mission, which observed the accreting neutron star GX 301-2 from Antarctica, between December 29th 2018 and January 1st 2019. The XL-Calibur design incorporates an X-ray mirror, which focusses X-rays onto a polarimeter comprisin…
▽ More
XL-Calibur is a hard X-ray (15-80 keV) polarimetry mission operating from a stabilised balloon-borne platform in the stratosphere. It builds on heritage from the X-Calibur mission, which observed the accreting neutron star GX 301-2 from Antarctica, between December 29th 2018 and January 1st 2019. The XL-Calibur design incorporates an X-ray mirror, which focusses X-rays onto a polarimeter comprising a beryllium rod surrounded by Cadmium Zinc Telluride (CZT) detectors. The polarimeter is housed in an anticoincidence shield to mitigate background from particles present in the stratosphere. The mirror and polarimeter-shield assembly are mounted at opposite ends of a 12 m long lightweight truss, which is pointed with arcsecond precision by WASP - the Wallops Arc Second Pointer. The XL-Calibur mission will achieve a substantially improved sensitivity over X-Calibur by using a larger effective area X-ray mirror, reducing background through thinner CZT detectors, and improved anticoincidence shielding. When observing a 1 Crab source for $t_{\rm day}$ days, the Minimum Detectable Polarisation (at 99% confidence level) is $\sim$2$\%\cdot t_{\rm day}^{-1/2}$. The energy resolution at 40 keV is $\sim$5.9 keV. The aim of this paper is to describe the design and performance of the XL-Calibur mission, as well as the foreseen science programme.
△ Less
Submitted 20 October, 2020;
originally announced October 2020.
-
Evolution of timing and spectral characteristics of 4U 1901+03 during its 2019 outburst using the Swift and NuSTAR observatories
Authors:
Aru Beri,
Tinku,
Nirmal K. Iyer,
Chandreyee Maitra
Abstract:
We report the results from a detailed timing and spectral study of transient X-ray pulsars, 4U 1901+03 during its 2019 outburst. We performed broadband spectroscopy in the 1-70 keV energy band using four observations made with Swift and NuSTAR at different intensity levels. Our timing results reveal the presence of highly variable pulse profiles dependent on both luminosity and energy. Our spectro…
▽ More
We report the results from a detailed timing and spectral study of transient X-ray pulsars, 4U 1901+03 during its 2019 outburst. We performed broadband spectroscopy in the 1-70 keV energy band using four observations made with Swift and NuSTAR at different intensity levels. Our timing results reveal the presence of highly variable pulse profiles dependent on both luminosity and energy. Our spectroscopy results showed the presence of a cyclotron resonance scattering feature (CRSF) at ~30 keV. This feature at 30 keV is highly luminosity and pulse-phase dependent. Phase-averaged spectra during the last two observations, made close to the declining phase of the outburst showed the presence of this feature at around 30 keV. The existence of CRSF at 30 keV during these observations is well supported by an abrupt change in the shape of pulse profiles found close to this energy. We also found that 30 keV feature was significantly detected in the pulse-phase resolved spectra of observations made at relatively high luminosities. Moreover, all spectral fit parameters showed a strong pulse phase dependence. In line with the previous findings, an absorption feature at around 10 keV is significantly observed in the phase-averaged X-ray spectra of all observations and also showed a strong pulse phase dependence.
△ Less
Submitted 26 October, 2020; v1 submitted 27 September, 2020;
originally announced September 2020.
-
A Compton polarimeter using scintillators read out with MPPCs through Citiroc ASIC
Authors:
Rakhee Kushwah,
Nirmal K. Iyer,
Mózsi Kiss,
Theodor A. Stana,
Mark Pearce
Abstract:
In recent years, a number of purpose-built scintillator-based polarimeters have studied bright astronomical sources for the first time in the hard X-ray band (tens to hundreds of keV). The addition of polarimetry can help data interpretation by resolving model-dependent degeneracies. The typical instrument approach is that incident X-rays scatter off a plastic scintillator into an adjacent scintil…
▽ More
In recent years, a number of purpose-built scintillator-based polarimeters have studied bright astronomical sources for the first time in the hard X-ray band (tens to hundreds of keV). The addition of polarimetry can help data interpretation by resolving model-dependent degeneracies. The typical instrument approach is that incident X-rays scatter off a plastic scintillator into an adjacent scintillator cell. In all missions to date, the scintillators are read out using traditional vacuum tube photo-multipliers (PMTs). The advent of solid-state PMTs ("silicon PM" or "MPPC") is attractive for space-based instruments since the devices are compact, robust and require a low bias voltage. We have characterised the plastic scintillator, EJ-248M, optically coupled to a multi-pixel photon counter (MPPC) and read out with the Citiroc ASIC. A light-yield of 1.6 photoelectrons/keV has been obtained, with a low energy detection threshold of $\lesssim$5 keV at room temperature. We have also constructed an MPPC-based polarimeter-demonstrator in order to investigate the feasibility of such an approach for future instruments. Incident X-rays scatter from a plastic-scintillator bar to surrounding cerium-doped GAGG (Gadolinium Aluminium Gallium Garnet) scintillators yielding time-coincident signals in the scintillators. We have determined the polarimetric response of this set-up using both unpolarised and polarised $\sim$50 keV X-rays. We observe a clear asymmetry in the GAGG counting rates for the polarised beam. The low-energy detection threshold in the plastic scintillator can be further reduced using a coincidence technique. The demonstrated polarimeter design shows promise as a space-based Compton polarimeter and we discuss ways in which our polarimeter can be adapted for such a mission.
△ Less
Submitted 21 July, 2019;
originally announced July 2019.
-
LAXPC / AstroSat Study of ~ 1 and ~ 2 mHz Quasi-periodic Oscillations in the Be/X-ray Binary 4U 0115+63 During its 2015 Outburst
Authors:
Jayashree Roy,
P. C. Agrawal,
N. K. Iyer,
D. Bhattacharya,
J. S. Yadav,
H. M. Antia,
J. V. Chauhan,
M. Choudhury,
D. K. Dedhia,
T. Katoch,
P. Madhavani,
R. K. Manchanda,
R. Misra,
M. Pahari,
B. Paul,
P. Shah
Abstract:
The Be X-ray Binary 4U 0115+63 was observed by Large Area X-ray Proportional Counter (LAXPC) instrument on AstroSat on 2015 October 24 during the peak of a giant Type II outburst. Prominent intensity oscillations at ~ 1 and ~ 2 mHz frequency were detected during the outburst. Nuclear Spectroscopic Telescope Array (NuSTAR) observations made during the same outburst also show mHz quasi periodic osci…
▽ More
The Be X-ray Binary 4U 0115+63 was observed by Large Area X-ray Proportional Counter (LAXPC) instrument on AstroSat on 2015 October 24 during the peak of a giant Type II outburst. Prominent intensity oscillations at ~ 1 and ~ 2 mHz frequency were detected during the outburst. Nuclear Spectroscopic Telescope Array (NuSTAR) observations made during the same outburst also show mHz quasi periodic oscillations (QPOs). Details of the oscillations and their characteristics deduced from LAXPC/AstroSat and NuSTAR observations are reported in this paper. Analysis of the archival Rossi X-ray Timing Explorer (RXTE)/Proportional Counter Array (PCA) data during 2001-11 also show presence of mHz QPOs during some of the outbursts and details of these QPOs are also reported. Possible models to explain the origin of the mHz oscillations are examined. Similar QPOs, albeit at higher frequencies, have been reported from other neutron star and black hole sources and both may have a common origin. Current models to explain the instability in the inner accretion disk causing the intense oscillations are discussed.
△ Less
Submitted 27 January, 2019;
originally announced January 2019.
-
Gamma-ray burst localisation strategies for the SPHiNX hard X-ray polarimeter
Authors:
L. Heckmann,
N. K. Iyer,
M. Kiss,
M. Pearce,
F. Xie
Abstract:
SPHiNX is a proposed gamma-ray burst (GRB) polarimeter mission operating in the energy range 50-600 keV with the aim of studying the prompt emission phase. The polarisation sensitivity of SPHiNX reduces as the uncertainty on the GRB sky position increases. The stand-alone ability of the SPHiNX design to localise GRB positions is explored via Geant4 simulations. Localisation at the level of a few d…
▽ More
SPHiNX is a proposed gamma-ray burst (GRB) polarimeter mission operating in the energy range 50-600 keV with the aim of studying the prompt emission phase. The polarisation sensitivity of SPHiNX reduces as the uncertainty on the GRB sky position increases. The stand-alone ability of the SPHiNX design to localise GRB positions is explored via Geant4 simulations. Localisation at the level of a few degrees is possible using three different routines. This results in a large fraction (> 80%) of observed GRBs having a negligible (< 5%) reduction in polarisation sensitivity due to the uncertainty in localisation.
△ Less
Submitted 25 January, 2019;
originally announced January 2019.
-
Science prospects for SPHiNX - a small satellite GRB polarimetry mission
Authors:
M. Pearce,
L. Eliasson,
N. Kumar Iyer,
M. Kiss,
R. Kushwah,
J. Larsson,
C. Lundman,
V. Mikhalev,
F. Ryde,
T. -A. Stana,
H. Takahashi,
F. Xie
Abstract:
Gamma-ray bursts (GRBs) are exceptionally bright electromagnetic events occurring daily on the sky. The prompt emission is dominated by X-/$γ$-rays. Since their discovery over 50 years ago, GRBs are primarily studied through spectral and temporal measurements. The properties of the emission jets and underlying processes are not well understood. A promising way forward is the development of mission…
▽ More
Gamma-ray bursts (GRBs) are exceptionally bright electromagnetic events occurring daily on the sky. The prompt emission is dominated by X-/$γ$-rays. Since their discovery over 50 years ago, GRBs are primarily studied through spectral and temporal measurements. The properties of the emission jets and underlying processes are not well understood. A promising way forward is the development of missions capable of characterising the linear polarisation of the high-energy emission. For this reason, the SPHiNX mission has been developed for a small-satellite platform. The polarisation properties of incident high-energy radiation (50-600 keV) are determined by reconstructing Compton scattering interactions in a segmented array of plastic and Gd$_3$Al$_2$Ga$_3$O$_{12}$(Ce) (GAGG(Ce)) scintillators. During a two-year mission, $\sim$200 GRBs will be observed, with $\sim$50 yielding measurements where the polarisation fraction is determined with a relative error $\leq$10%. This is a significant improvement compared to contemporary missions. This performance, combined with the ability to reconstruct GRB localisation and spectral properties, will allow discrimination between leading classes of emission models.
△ Less
Submitted 16 August, 2018;
originally announced August 2018.