CRIRES$^{+}$ on sky at the ESO Very Large Telescope
Authors:
R. J. Dorn,
P. Bristow,
J. V. Smoker,
F. Rodler,
A. Lavail,
M. Accardo,
M. van den Ancker,
D. Baade,
A. Baruffolo,
B. Courtney-Barrer,
L. Blanco,
A. Brucalassi,
C. Cumani,
R. Follert,
A. Haimerl,
A. Hatzes,
M. Haug,
U. Heiter,
R. Hinterschuster,
N. Hubin,
D. J. Ives,
Y. Jung,
M. Jones,
J-P. Kirchbauer,
B. Klein
, et al. (27 additional authors not shown)
Abstract:
The CRyogenic InfraRed Echelle Spectrograph (CRIRES) Upgrade project CRIRES$^{+}$ extended the capabilities of CRIRES. It transformed this VLT instrument into a cross-dispersed spectrograph to increase the wavelength range that is covered simultaneously by up to a factor of ten. In addition, a new detector focal plane array of three Hawaii 2RG detectors with a 5.3 $μ$m cutoff wavelength replaced t…
▽ More
The CRyogenic InfraRed Echelle Spectrograph (CRIRES) Upgrade project CRIRES$^{+}$ extended the capabilities of CRIRES. It transformed this VLT instrument into a cross-dispersed spectrograph to increase the wavelength range that is covered simultaneously by up to a factor of ten. In addition, a new detector focal plane array of three Hawaii 2RG detectors with a 5.3 $μ$m cutoff wavelength replaced the existing detectors. Amongst many other improvements, a new spectropolarimetric unit was added and the calibration system has been enhanced. The instrument was installed at the VLT on Unit Telescope 3 at the beginning of 2020 and successfully commissioned and verified for science operations during 2021, partly remotely from Europe due to the COVID-19 pandemic. The instrument was subsequently offered to the community from October 2021 onwards. This article describes the performance and capabilities of the upgraded instrument and presents on sky results.
△ Less
Submitted 19 January, 2023;
originally announced January 2023.
-
HiPERCAM: a quintuple-beam, high-speed optical imager on the 10.4-m Gran Telescopio Canarias
Authors:
V. S. Dhillon,
N. Bezawada,
M. Black,
S. D. Dixon,
T. Gamble,
X. Gao,
D. M. Henry,
P. Kerry,
S. P. Littlefair,
D. W. Lunney,
T. R. Marsh,
C. Miller,
S. G. Parsons,
R. P. Ashley,
E. Breedt,
A. Brown,
M. J. Dyer,
M. J. Green,
I. Pelisoli,
D. I. Sahman,
J. Wild,
D. J. Ives,
L. Mehrgan,
J. Stegmeier,
C. M. Dubbeldam
, et al. (14 additional authors not shown)
Abstract:
HiPERCAM is a portable, quintuple-beam optical imager that saw first light on the 10.4-m Gran Telescopio Canarias (GTC) in 2018. The instrument uses re-imaging optics and 4 dichroic beamsplitters to record $u_s g_s r_s i_s z_s$ ($320-1060$ nm) images simultaneously on its five CCD cameras, each of 3.1 arcmin (diagonal) field of view. The detectors in HiPERCAM are frame-transfer devices cooled ther…
▽ More
HiPERCAM is a portable, quintuple-beam optical imager that saw first light on the 10.4-m Gran Telescopio Canarias (GTC) in 2018. The instrument uses re-imaging optics and 4 dichroic beamsplitters to record $u_s g_s r_s i_s z_s$ ($320-1060$ nm) images simultaneously on its five CCD cameras, each of 3.1 arcmin (diagonal) field of view. The detectors in HiPERCAM are frame-transfer devices cooled thermo-electrically to 183 K, thereby allowing both long-exposure, deep imaging of faint targets, as well as high-speed (over 1000 windowed frames per second) imaging of rapidly varying targets. A comparison-star pick-off system in the telescope focal plane increases the effective field of view to 6.7 arcmin for differential photometry. Combining HiPERCAM with the world's largest optical telescope enables the detection of astronomical sources to $g_s \sim 23$ in 1 s and $g_s \sim 28$ in 1 h. In this paper we describe the scientific motivation behind HiPERCAM, present its design, report on its measured performance, and outline some planned enhancements.
△ Less
Submitted 21 July, 2021;
originally announced July 2021.
-
Perturbation-based Frequency Domain Linear and Nonlinear Noise Estimation
Authors:
F. J. Vaquero-Caballero,
D. J. Ives,
S. J. Savory
Abstract:
In this paper, a new method for the separation of noise categories based on Four-Wave Mixing is presented.
The theoretical analysis is grounded in the Gaussian Noise model and verified by split step simulations. The noise categories react differently to the introduced perturbations, by performing a set of perturbations the behaviour of the different categories can be separated by means of a leas…
▽ More
In this paper, a new method for the separation of noise categories based on Four-Wave Mixing is presented.
The theoretical analysis is grounded in the Gaussian Noise model and verified by split step simulations. The noise categories react differently to the introduced perturbations, by performing a set of perturbations the behaviour of the different categories can be separated by means of a least-square fitting. Given ASE is independent of the induced perturbations, it is possible to separate noise contributions. The analysis includes constant and variable power perturbations.
The estimation of the noise categories is discussed from two points of view: NSR evolution post-DSP processing, and over the power spectral density in a notched region. The NSR estimation can only be performed at reception, whereas the power spectral density approach can be performed along the optical link if a high resolution Optical Spectrum Analyzer is available.
Additionally, we perform a simple experimental verification considering of two WaveLogic 3 transceivers for the NSR, successfully estimating the noise contributions.
△ Less
Submitted 9 May, 2021;
originally announced May 2021.
-
Transceiver Noise Characterization based on Perturbations
Authors:
F. J. Vaquero-Caballero,
D. J. Ives,
S. J. Savory
Abstract:
In this paper, we discuss a new technique for measuring transceiver noise, skew, and for the detection of uncompensated transceiver impairments. The method consists on the introduction of frequency domain notch or notches at the transmitter, which allows to estimate of the Signal-to-Noise and Distortion Ratio (SNDR) at different stages over the transmission chain. The proposed technique requires t…
▽ More
In this paper, we discuss a new technique for measuring transceiver noise, skew, and for the detection of uncompensated transceiver impairments. The method consists on the introduction of frequency domain notch or notches at the transmitter, which allows to estimate of the Signal-to-Noise and Distortion Ratio (SNDR) at different stages over the transmission chain. The proposed technique requires the detection of the signal spectrum using either: a modem receiver, an Optical Spectrum Analyzer (OSA), an oscilloscope, or an Electrical Spectrum Analyzer (ESA), depending on the stage where the spectrum is measured and requiring minimal processing of the received signal.
Our analysis is focused on Ciena's WaveLogic Ai commercial transceiver and a 95 Gbaud DAC. We demonstrate that symmetrically placed frequency domain notches can be used to mitiguate the influence of crosstalk on the SNDR estimates.
Finally, we show how a single notch spectrum can be used to detect and compensate for impairments, and we perform skew estimation as an example.
△ Less
Submitted 3 April, 2021;
originally announced April 2021.
-
In-band Perturbation based OSNR Estimation
Authors:
F. J. Vaquero-Caballero,
D. Charlton,
M. E. Mousa-Pasandi,
D. J. Ives,
C. Laperle,
M. Hubbard,
M. Reimer,
M. OSullivan,
S. J. Savory
Abstract:
Perturbed spectra are modelled to estimate OSNR for a single channel amplified link. Perturbation-dependent nonlinear noise is separated from constant ASE noise using a set of propagated perturbed spectra. A least mean square fitting is used to estimate OSNR with standard deviation of 0.16 dB.
Perturbed spectra are modelled to estimate OSNR for a single channel amplified link. Perturbation-dependent nonlinear noise is separated from constant ASE noise using a set of propagated perturbed spectra. A least mean square fitting is used to estimate OSNR with standard deviation of 0.16 dB.
△ Less
Submitted 3 April, 2021; v1 submitted 17 October, 2020;
originally announced November 2020.
-
Fast method of crosstalk characterization for HxRG detectors
Authors:
Elizabeth M. George,
Simon M. Tulloch,
Derek J. Ives
Abstract:
HxRG detectors have crosstalk between amplifier channels at a scientifically relevant level. In principle, crosstalk signals can be fully calibrated and removed from data, but only if a full crosstalk matrix is measured for the detector. We present a fast method of crosstalk characterization that can be performed with most instrument calibration units; it requires only a flat-field illumination an…
▽ More
HxRG detectors have crosstalk between amplifier channels at a scientifically relevant level. In principle, crosstalk signals can be fully calibrated and removed from data, but only if a full crosstalk matrix is measured for the detector. We present a fast method of crosstalk characterization that can be performed with most instrument calibration units; it requires only a flat-field illumination and window programming in the HxRG detectors. We show the crosstalk matrices obtained with this method for both fast and slow mode in an H2RG detector, and give examples of how this data can be used to tune detector operation parameters, feed back into the electronics design for the cryogenic pre-amplifiers, and be used in the data pipeline to remove crosstalk signal from scientific data.
△ Less
Submitted 15 November, 2019; v1 submitted 2 August, 2018;
originally announced August 2018.
-
On the Impact of Optimal Modulation and FEC Overhead on Future Optical Networks
Authors:
Alex Alvarado,
David J. Ives,
Seb Savory,
Polina Bayvel
Abstract:
The potential of optimum selection of modulation and forward error correction (FEC) overhead (OH) in future transparent nonlinear optical mesh networks is studied from an information theory perspective. Different network topologies are studied as well as both ideal soft-decision (SD) and hard-decision (HD) FEC based on demap-and-decode (bit-wise) receivers. When compared to the de-facto QPSK with…
▽ More
The potential of optimum selection of modulation and forward error correction (FEC) overhead (OH) in future transparent nonlinear optical mesh networks is studied from an information theory perspective. Different network topologies are studied as well as both ideal soft-decision (SD) and hard-decision (HD) FEC based on demap-and-decode (bit-wise) receivers. When compared to the de-facto QPSK with 7% OH, our results show large gains in network throughput. When compared to SD-FEC, HD-FEC is shown to cause network throughput losses of 12%, 15%, and 20% for a country, continental, and global network topology, respectively. Furthermore, it is shown that most of the theoretically possible gains can be achieved by using one modulation format and only two OHs. This is in contrast to the infinite number of OHs required in the ideal case. The obtained optimal OHs are between 5% and 80%, which highlights the potential advantage of using FEC with high OHs.
△ Less
Submitted 20 August, 2015; v1 submitted 19 August, 2015;
originally announced August 2015.
-
ULTRASPEC: a high-speed imaging photometer on the 2.4-m Thai National Telescope
Authors:
V. S. Dhillon,
T. R. Marsh,
D. C. Atkinson,
N. Bezawada,
M. C. P. Bours,
C. M. Copperwheat,
T. Gamble,
L. K. Hardy,
R. D. H. Hickman,
P. Irawati,
D. J. Ives,
P. Kerry,
A. Leckngam,
S. P. Littlefair,
S. A. McLay,
K. O'Brien,
P. T. Peacocke,
S. Poshyachinda,
A. Richichi,
B. Soonthornthum,
A. Vick
Abstract:
ULTRASPEC is a high-speed imaging photometer mounted permanently at one of the Nasmyth focii of the 2.4-m Thai National Telescope (TNT) on Doi Inthanon, Thailand's highest mountain. ULTRASPEC employs a 1024x1024 pixel frame-transfer, electron-multiplying CCD (EMCCD) in conjunction with re-imaging optics to image a field of 7.7'x7.7' at (windowed) frame rates of up to ~200 Hz. The EMCCD has two out…
▽ More
ULTRASPEC is a high-speed imaging photometer mounted permanently at one of the Nasmyth focii of the 2.4-m Thai National Telescope (TNT) on Doi Inthanon, Thailand's highest mountain. ULTRASPEC employs a 1024x1024 pixel frame-transfer, electron-multiplying CCD (EMCCD) in conjunction with re-imaging optics to image a field of 7.7'x7.7' at (windowed) frame rates of up to ~200 Hz. The EMCCD has two outputs - a normal output that provides a readout noise of 2.3 e- and an avalanche output that can provide essentially zero readout noise. A six-position filter wheel enables narrow-band and broad-band imaging over the wavelength range 330-1000 nm. The instrument saw first light on the TNT in November 2013 and will be used to study rapid variability in the Universe. In this paper we describe the scientific motivation behind ULTRASPEC, present an outline of its design and report on its measured performance on the TNT.
△ Less
Submitted 12 August, 2014;
originally announced August 2014.
-
Concept and optical design of the cross-disperser module for CRIRES+
Authors:
E. Oliva,
A. Tozzi,
D. Ferruzzi,
L. Origlia,
A. Hatzes,
R. Follert,
T. Loewinger,
N. Piskunov,
U. Heiter,
M. Lockhart,
T. Marquart,
E. Stempels,
A. Reiners,
G. Anglada-Escude,
U. Seemann,
R. J. Dorn,
P. Bristow,
D. Baade,
B. Delabre,
D. Gojak,
J. Grunhut,
B. Klein,
M. Hilker,
D. J. Ives,
Y. Jung
, et al. (9 additional authors not shown)
Abstract:
CRIRES, the ESO high resolution infrared spectrometer, is a unique instrument which allows astronomers to access a parameter space which up to now was largely uncharted. In its current setup, it consists of a single-order spectrograph providing long-slit, single-order spectroscopy with resolving power up to R=100,000 over a quite narrow spectral range. This has resulted in sub-optimal efficiency a…
▽ More
CRIRES, the ESO high resolution infrared spectrometer, is a unique instrument which allows astronomers to access a parameter space which up to now was largely uncharted. In its current setup, it consists of a single-order spectrograph providing long-slit, single-order spectroscopy with resolving power up to R=100,000 over a quite narrow spectral range. This has resulted in sub-optimal efficiency and use of telescope time for all the scientific programs requiring broad spectral coverage of compact objects (e.g. chemical abundances of stars and intergalactic medium, search and characterization of extra-solar planets). To overcome these limitations, a consortium was set-up for upgrading CRIRES to a cross-dispersed spectrometer, called CRIRES+. This paper presents the updated optical design of the crossdispersion module for CRIRES+. This new module can be mounted in place of the current pre-disperser unit. The new system yields a factor of >10 increase in simultaneous spectral coverage and maintains a quite long slit (10"), ideal for observations of extended sources and for precise sky-background subtraction.
△ Less
Submitted 11 July, 2014;
originally announced July 2014.
-
ULTRACAM: an ultra-fast, triple-beam CCD camera for high-speed astrophysics
Authors:
V. S. Dhillon,
T. R. Marsh,
M. J. Stevenson,
D. C. Atkinson,
P. Kerry,
P. T. Peacocke,
A. J. A. Vick,
S. M. Beard,
D. J. Ives,
D. W. Lunney,
S. A. McLay,
C. J. Tierney,
J. Kelly,
S. P. Littlefair,
R. Nicholson,
R. Pashley,
E. T. Harlaftis,
K. O'Brien
Abstract:
ULTRACAM is a portable, high-speed imaging photometer designed to study faint astronomical objects at high temporal resolutions. ULTRACAM employs two dichroic beamsplitters and three frame-transfer CCD cameras to provide three-colour optical imaging at frame rates of up to 500 Hz. The instrument has been mounted on both the 4.2-m William Herschel Telescope on La Palma and the 8.2-m Very Large Te…
▽ More
ULTRACAM is a portable, high-speed imaging photometer designed to study faint astronomical objects at high temporal resolutions. ULTRACAM employs two dichroic beamsplitters and three frame-transfer CCD cameras to provide three-colour optical imaging at frame rates of up to 500 Hz. The instrument has been mounted on both the 4.2-m William Herschel Telescope on La Palma and the 8.2-m Very Large Telescope in Chile, and has been used to study white dwarfs, brown dwarfs, pulsars, black-hole/neutron-star X-ray binaries, gamma-ray bursts, cataclysmic variables, eclipsing binary stars, extrasolar planets, flare stars, ultra-compact binaries, active galactic nuclei, asteroseismology and occultations by Solar System objects (Titan, Pluto and Kuiper Belt objects). In this paper we describe the scientific motivation behind ULTRACAM, present an outline of its design and report on its measured performance.
△ Less
Submitted 19 April, 2007;
originally announced April 2007.