-
Microwave Cavity Mode Optimisation by Background Anti-Resonance Tuning
Authors:
Michael T. Hatzon,
Eugene N. Ivanov,
Jeremy F. Bourhill,
Maxim Goryachev,
Michael E. Tobar
Abstract:
To derive the best oscillator phase noise when implementing a high-Q resonator, the spectral line-shape must have high contrast and symmetry. Ideally, this line-shape is Lorentzian, however, in a high mode density spectral region, low-Q background spurious modes interact and distort the resonance. For a sapphire-loaded cavity resonator operating with whispering gallery modes we show that this high…
▽ More
To derive the best oscillator phase noise when implementing a high-Q resonator, the spectral line-shape must have high contrast and symmetry. Ideally, this line-shape is Lorentzian, however, in a high mode density spectral region, low-Q background spurious modes interact and distort the resonance. For a sapphire-loaded cavity resonator operating with whispering gallery modes we show that this high contrast and symmetry can be achieved by changing the dimensions of the surrounding cavity shield to tune the background low-Q structures into anti-resonance. This works because the high-Q resonances are primarily defined by the sapphire while the background modes are defined by the cavity shield. Alternatively, it was shown that a similar result can be achieved by exciting the high-Q resonator with a balanced microwave dipole probe in a Mach Zehnder interferometric configuration. The probe was constructed from two separate coaxial electric field probes symmetrically inserted into a cylindrical cavity resonator, from opposite sides with a small gap between them, so they can behave like an active wire dipole antenna. The power into the two separate probes may be matched with an external variable attenuator in one of the arms of the interferometer. Conversely, the phase between the two electric field probes may be changed with an external variable phase shifter, which changes the nature of the field components the probe couples to. The probe couples to the high-Q resonant modes as well as low-Q background modes, which can be made resonant or anti-resonant for the high-Q modes by changing this external phase. When the background modes are in anti-resonance the line shape of the high-Q mode can be made symmetric and with higher contrast. This technique was applied to both whispering gallery sapphire modes, as well as hollow cavity resonators, without changing the dimensions of the cavity.
△ Less
Submitted 25 April, 2024;
originally announced May 2024.
-
Noise Suppression with Cryogenic Resonators
Authors:
Eugene N. Ivanov,
Michael E. Tobar
Abstract:
We show that fast technical fluctuations of microwave signals can be strongly suppressed by cryogenic resonators. The experiments were carried out with sapphire resonators cooled to approximately 6 K at frequencies around 11 GHz. Each sapphire crystal was shaped like a spindle with the rotational and crystal axes aligned within a degree. Noise suppression factors in excess of 50 dB were measured a…
▽ More
We show that fast technical fluctuations of microwave signals can be strongly suppressed by cryogenic resonators. The experiments were carried out with sapphire resonators cooled to approximately 6 K at frequencies around 11 GHz. Each sapphire crystal was shaped like a spindle with the rotational and crystal axes aligned within a degree. Noise suppression factors in excess of 50 dB were measured at 10 kHz offset from the carrier. This was achieved by rotating the sapphire spindle and moving the coupling probes relative to its surface. Microwave signals with reduced fast technical fluctuations allow the high-precision tests of fundamental physics, as well as the development of better radars.
△ Less
Submitted 27 March, 2024;
originally announced March 2024.
-
Frequency Stable Microwave Sapphire Oscillators
Authors:
Eugene N. Ivanov,
Michael E. Tobar
Abstract:
We show that state-of-the-art phase noise and high frequency stability could be simultaneously achieved in a microwave oscillator based on the sapphire-loaded cavity resonator. The 9 GHz sapphire oscillator was constructed with the SSB phase noise close to -170 dBc/Hz at an offset frequency of 10 kHz and fractional frequency instability less than 2 10$^{-13}$ for integration times from 5 to 50 s.…
▽ More
We show that state-of-the-art phase noise and high frequency stability could be simultaneously achieved in a microwave oscillator based on the sapphire-loaded cavity resonator. The 9 GHz sapphire oscillator was constructed with the SSB phase noise close to -170 dBc/Hz at an offset frequency of 10 kHz and fractional frequency instability less than 2 10$^{-13}$ for integration times from 5 to 50 s. In this work, we focus on the technique for phase-referencing the microwave sapphire oscillator to a stable radio-frequency source. We also discuss the suppression of the fast phase fluctuations of the microwave signal due to its transmission through the high-Q resonator.
△ Less
Submitted 27 March, 2024;
originally announced March 2024.
-
Exclusion of ALP Cogenesis Dark Matter in a Mass Window Above 100 $μ$eV
Authors:
Aaron Quiskamp,
Ben T. McAllister,
Paul Altin,
Eugene N. Ivanov,
Maxim Goryachev,
Michael E. Tobar
Abstract:
We report the results of Phase 1b of The ORGAN Experiment, a microwave cavity haloscope searching for dark matter axions in the $107.42-111.93~μ$eV mass range. The search excludes axions with two-photon coupling $g_{aγγ}\geq 4\times 10^{-12}\, \textrm{GeV}^{-1}$ with $95\%$ confidence interval, setting the best upper bound to date and with the required sensitivity to exclude the axion-like particl…
▽ More
We report the results of Phase 1b of The ORGAN Experiment, a microwave cavity haloscope searching for dark matter axions in the $107.42-111.93~μ$eV mass range. The search excludes axions with two-photon coupling $g_{aγγ}\geq 4\times 10^{-12}\, \textrm{GeV}^{-1}$ with $95\%$ confidence interval, setting the best upper bound to date and with the required sensitivity to exclude the axion-like particle cogenesis model for dark matter in this range. This result was achieved using a tunable rectangular cavity, which mitigated several practical issues that become apparent when conducting high mass axion searches, and was the first such axion search to be conducted with such a cavity. It also represents the most sensitive axion haloscope experiment to date in the $\sim100~μ$eV mass region.
△ Less
Submitted 2 October, 2023;
originally announced October 2023.
-
Searching for Low-Mass Axions using Resonant Upconversion
Authors:
Catriona A. Thomson,
Maxim Goryachev,
Ben T. McAllister,
Eugene N. Ivanov,
Paul Altin,
Michael E. Tobar
Abstract:
We present new results of a room temperature resonant AC haloscope, which searches for axions via photon upconversion. Traditional haloscopes require a strong applied DC magnetic background field surrounding the haloscope cavity resonator, the resonant frequency of which is limited by available bore dimensions. UPLOAD, the UPconversion Low-Noise Oscillator Axion Detection experiment, replaces this…
▽ More
We present new results of a room temperature resonant AC haloscope, which searches for axions via photon upconversion. Traditional haloscopes require a strong applied DC magnetic background field surrounding the haloscope cavity resonator, the resonant frequency of which is limited by available bore dimensions. UPLOAD, the UPconversion Low-Noise Oscillator Axion Detection experiment, replaces this DC magnet with a second microwave background resonance within the detector cavity, which upconverts energy from the axion field into the readout mode, accessing axions around the beat frequency of the modes. Furthermore, unlike the DC case, the experiment is sensitive to a newly proposed quantum electromagnetodynamical axion coupling term $g_{aBB}$. Two experimental approaches are outlined - one using frequency metrology, and the other using power detection of a thermal readout mode. The results of the power detection experiment are presented, which allows exclusion of axions of masses between 1.12 $-$ 1.20 $μeV$ above a coupling strength of both $g_{aγγ}$ and $g_{aBB}$ at $3 \times 10^{-6}$ 1/GeV, after a measurement period of 30 days, which is a three order of magnitude improvement over our previous result.
△ Less
Submitted 11 May, 2023; v1 submitted 17 January, 2023;
originally announced January 2023.
-
Comparing Instrument Spectral Sensitivity of Dissimilar Electromagnetic Haloscopes to Axion Dark Matter and High Frequency Gravitational Waves
Authors:
Michael E. Tobar,
Catriona A. Thomson,
William M. Campbell,
Aaron Quiskamp,
Jeremy F. Bourhill,
Benjamin T. McAllister,
Eugene N. Ivanov,
Maxim Goryachev
Abstract:
It is known that haloscopes that search for dark matter axions via the axion-photon anomaly are also sensitive to gravitational radiation through the inverse Gertsenshtein effect. Recently this way of searching for high frequency gravitational waves has gained momentum as it has been shown that the strain sensitivities of such detectors are of the same order of sensitivity to the axion-photon thet…
▽ More
It is known that haloscopes that search for dark matter axions via the axion-photon anomaly are also sensitive to gravitational radiation through the inverse Gertsenshtein effect. Recently this way of searching for high frequency gravitational waves has gained momentum as it has been shown that the strain sensitivities of such detectors are of the same order of sensitivity to the axion-photon theta angle. Thus, after calculating the sensitivity of a haloscope to an axion signal, we also have calculated the order of magnitude sensitivity to a gravitational wave signal of the same spectral and temporal form. However, it is unlikely that a gravitational wave and an axion signal will be of the same form, since physically the way the signals are generated are completely different. For gravitational wave detection, the spectral strain sensitivity is in units strain per square root Hz, is the natural way to compare the sensitivity of gravitational wave detectors due to its independence on the gravitational wave signal. In this work, we introduce a systematic way to calculate the spectral sensitivity of an axion haloscope, so instrument comparison may be achieved independent of signal assumptions and only depends on the axion to signal transduction sensitivity and noise in the instrument. Thus, the calculation of the spectral sensitivity not only allows the comparison of dissimilar axion detectors independent of signal, but also allows us to compare the order of magnitude gravitational wave sensitivity in terms of spectral strain sensitivity, allowing comparisons to standard gravitational wave detectors based on optical interferometers and resonant-mass technology.
△ Less
Submitted 16 October, 2022; v1 submitted 7 September, 2022;
originally announced September 2022.
-
Direct Search for Dark Matter Axions Excluding ALP Cogenesis in the 63-67 micro-eV Range, with The ORGAN Experiment
Authors:
Aaron P. Quiskamp,
Ben T. McAllister,
Paul Altin,
Eugene N. Ivanov,
Maxim Goryachev,
Michael E. Tobar
Abstract:
The standard model axion seesaw Higgs portal inflation (SMASH) model is a well motivated, self-contained description of particle physics over a range of energy scales that predicts axion dark matter particles to exist within the mass range of $50-200\,μ$eV. To scan these masses an axion haloscope under a strong constant magnetic field must operate between 12 to 48 GHz. The ORGAN experiment (situat…
▽ More
The standard model axion seesaw Higgs portal inflation (SMASH) model is a well motivated, self-contained description of particle physics over a range of energy scales that predicts axion dark matter particles to exist within the mass range of $50-200\,μ$eV. To scan these masses an axion haloscope under a strong constant magnetic field must operate between 12 to 48 GHz. The ORGAN experiment (situated in Perth, Australia) is a microwave cavity axion haloscope that aims to search the majority of the mass range predicted by the SMASH model. Here we present results of Phase 1a, the first experiment to scan and search for axions in the microwave Ku Band. Our initial scan sets a new limit on the coupling of axions to two photons of $g_{aγγ}\geq 3\times 10^{-12}\, \textrm{GeV}^{-1}$ over the mass range $63.2$ to $67.1~μ$eV with $95\%$ confidence. This result is the most sensitive to date in this mass range, sufficient to exclude the well motivated ALP (Axion Like Particle) cogenesis model for dark matter, which adds ALPs to the standard model in the early universe to simultaneously explain the observed baryon and dark matter densities. To attain this level of sensitivity we utilised a TM$_{010}$ cylindrical cavity resonator, scanned between 15.28 to 16.23 GHz through the utilisation of a tuning rod. Measurements were performed over a duration of 3.5 weeks with a $74\%$ duty cycle, with the resonator coupled to a low noise HEMT amplifier and placed inside a superconducting solenoidal electromagnet of 11.5 Tesla in magnetic field strength.
△ Less
Submitted 22 March, 2022;
originally announced March 2022.
-
Rare Events Detected with a Bulk Acoustic Wave High Frequency Gravitational Wave Antenna
Authors:
Maxim Goryachev,
William M. Campbell,
Ik Siong Heng,
Serge Galliou,
Eugene N. Ivanov,
Michael E. Tobar
Abstract:
This work describes the operation of a High Frequency Gravitational Wave detector based on a cryogenic Bulk Acoustic Wave (BAW) cavity and reports observation of rare events during 153 days of operation over two seperate experimental runs (Run 1 and Run 2). In both Run 1 and Run 2 two modes were simultaneously monitored. Across both runs, the 3rd overtone of the fast shear mode (3B) operating at 5…
▽ More
This work describes the operation of a High Frequency Gravitational Wave detector based on a cryogenic Bulk Acoustic Wave (BAW) cavity and reports observation of rare events during 153 days of operation over two seperate experimental runs (Run 1 and Run 2). In both Run 1 and Run 2 two modes were simultaneously monitored. Across both runs, the 3rd overtone of the fast shear mode (3B) operating at 5.506 MHz was monitored, while in Run 1 the second mode was chosen to be the 5th OT of the slow shear mode (5C) operating at 8.392 MHz. However, in Run 2 the second mode was selected to be closer in frequency to the first mode, and chosen to be the 3rd overtone of the slow shear mode (3C) operating at 4.993 MHz. Two strong events were observed as transients responding to energy deposition within acoustic modes of the cavity. The first event occurred during Run 1 on the 12/05/2019 (UTC), and was observed in the 5.506 MHz mode, while the second mode at 8.392 MHz observed no event. During Run 2, a second event occurred on the 27/11/2019(UTC) and was observed by both modes. Timing of the events were checked against available environmental observations as well as data from other detectors. Various possibilities explaining the origins of the events are discussed.
△ Less
Submitted 22 July, 2021; v1 submitted 11 February, 2021;
originally announced February 2021.
-
Searching for Scalar Dark Matter via Coupling to Fundamental Constants with Photonic, Atomic and Mechanical Oscillators
Authors:
William M. Campbell,
Ben T. McAllister,
Maxim Goryachev,
Eugene N. Ivanov,
Michael E. Tobar
Abstract:
We present a way to search for light scalar dark matter (DM), seeking to exploit putative coupling between dark matter scalar fields and fundamental constants, by searching for frequency modulations in direct comparisons between frequency stable oscillators. Specifically we compare a Cryogenic Sapphire Oscillator (CSO), Hydrogen Maser (HM) atomic oscillator and a bulk acoustic wave quartz oscillat…
▽ More
We present a way to search for light scalar dark matter (DM), seeking to exploit putative coupling between dark matter scalar fields and fundamental constants, by searching for frequency modulations in direct comparisons between frequency stable oscillators. Specifically we compare a Cryogenic Sapphire Oscillator (CSO), Hydrogen Maser (HM) atomic oscillator and a bulk acoustic wave quartz oscillator (OCXO). This work includes the first calculation of the dependence of acoustic oscillators on variations of the fundamental constants, and demonstration that they can be a sensitive tool for scalar DM experiments. Results are presented based on 16 days of data in comparisons between the HM and OCXO, and 2 days of comparison between the OCXO and CSO. No evidence of oscillating fundamental constants consistent with a coupling to scalar dark matter is found, and instead limits on the strength of these couplings as a function of the dark matter mass are determined. We constrain the dimensionless coupling constant $d_e$ and combination $|d_{m_e}-d_g|$ across the mass band $4.4\times10^{-19}\lesssim m_\varphi \lesssim 6.8\times10^{-14}\:\text{eV} c^{-2}$, with most sensitive limits $d_e\gtrsim1.59\times10^{-1}$, $|d_{m_e}-dg|\gtrsim6.97\times10^{-1}$. Notably, these limits do not rely on Maximum Reach Analysis (MRA), instead employing the more general coefficient separation technique. This experiment paves the way for future, highly sensitive experiments based on state-of-the-art acoustic oscillators, and we show that these limits can be competitive with the best current MRA-based exclusion limits.
△ Less
Submitted 15 April, 2021; v1 submitted 15 October, 2020;
originally announced October 2020.
-
Generation of Spectrally Pure Microwave Signals
Authors:
Eugene N. Ivanov,
Michael E. Tobar
Abstract:
Based on the principles of microwave circuit interferometry we have constructed a Reduced Noise Amplifier (RNA) with power spectral density of phase, as well as amplitude, fluctuations close to -170 dBc/Hz at 1 kHz offset. The RNA has been incorporated with a cryogenic sapphire resonator as a loop oscillator whose noise performance is governed by the Leeson's model. Following this model and using…
▽ More
Based on the principles of microwave circuit interferometry we have constructed a Reduced Noise Amplifier (RNA) with power spectral density of phase, as well as amplitude, fluctuations close to -170 dBc/Hz at 1 kHz offset. The RNA has been incorporated with a cryogenic sapphire resonator as a loop oscillator whose noise performance is governed by the Leeson's model. Following this model and using the results of in-situ measurements of gain and phase fluctuations of the RNA we inferred noise properties of the oscillator. In particular, for a signal transmitted through the resonator we found that power spectral density of its phase/amplitude fluctuations must be close to -185 dBc/Hz at offsets above 300 Hz. We discuss a few approaches that will allow direct measurements of such low levels of noise.
△ Less
Submitted 20 March, 2020;
originally announced March 2020.
-
UPconversion Loop Oscillator Axion Detection experiment: A precision frequency interferometric axion dark matter search with a Cylindrical Microwave Cavity
Authors:
Catriona A. Thomson,
Ben T. McAllister,
Maxim Goryachev,
Eugene N. Ivanov,
Michael E. Tobar
Abstract:
First experimental results from a room-temperature table-top phase-sensitive axion haloscope experiment are presented. The technique exploits the axion-photon coupling between two photonic resonator-oscillators excited in a single cavity, allowing low-mass axions to be upconverted to microwave frequencies, acting as a source of frequency modulation on the microwave carriers. This new pathway to ax…
▽ More
First experimental results from a room-temperature table-top phase-sensitive axion haloscope experiment are presented. The technique exploits the axion-photon coupling between two photonic resonator-oscillators excited in a single cavity, allowing low-mass axions to be upconverted to microwave frequencies, acting as a source of frequency modulation on the microwave carriers. This new pathway to axion detection has certain advantages over the traditional haloscope method, particularly in targeting axions below 1 $μ$eV (240 MHz) in energy where high volume magnets are necessary. At the heart of the dual-mode oscillator, a tunable cylindrical microwave cavity supports a pair of orthogonally polarized modes ($\text{TM}_{\text{0,2,0}}$ and $\text{TE}_{\text{0,1,1}}$), which, in general, enables simultaneous sensitivity to axions with masses corresponding to the sum and difference of the microwave frequencies. The results place axion exclusion limits between 7.44 - 19.38 neV, excluding a minimal coupling strength above $3\times 10^{-3}$ 1/GeV, and between 74.4 - 74.5 $μ$eV, excluding a minimal coupling strength above $10^{-2}$ 1/GeV, after a measurement period of two and a half hours. We show that a state-of-the-art frequency-stabilized cryogenic implementation of this technique may achieve competitive limits in a large range of axion-space.
△ Less
Submitted 8 June, 2021; v1 submitted 16 December, 2019;
originally announced December 2019.
-
Next Generation of Phonon Tests of Lorentz Invariance using Quartz BAW Resonators
Authors:
Maxim Goryachev,
Zeyu Kuang,
Eugene N. Ivanov,
Philipp Haslinger,
Holger Muller,
Michael E. Tobar
Abstract:
We demonstrate technological improvements in phonon sector tests of Lorentz Invariance that implement quartz Bulk Acoustic Wave oscillators. In this experiment, room temperature oscillators with state-of-the-art phase noise are continuously compared on a platform that rotates at a rate of order a cycle per second. The discussion is focused on improvements in noise measurement techniques, data acqu…
▽ More
We demonstrate technological improvements in phonon sector tests of Lorentz Invariance that implement quartz Bulk Acoustic Wave oscillators. In this experiment, room temperature oscillators with state-of-the-art phase noise are continuously compared on a platform that rotates at a rate of order a cycle per second. The discussion is focused on improvements in noise measurement techniques, data acquisition and data processing. Preliminary results of the second generation of such tests are given, and indicate that SME coefficients in the matter sector can be measured at a precision of order $10^{-16}$ GeV after taking a years worth of data. This is equivalent to an improvement of two orders of magnitude over the prior acoustic phonon sector experiment.
△ Less
Submitted 7 April, 2018;
originally announced April 2018.
-
Broadband Axion Dark Matter Haloscopes via Electric Sensing
Authors:
Ben T. McAllister,
Maxim Goryachev,
Jeremy Bourhill,
Eugene N. Ivanov,
Michael E. Tobar
Abstract:
The mass of axion dark matter is only weakly bounded by cosmological observations, necessitating a variety of detection techniques over several orders of magnitude of mass ranges. Axions haloscopes based on resonant cavities have become the current standard to search for dark matter axions. Such structures are inherently narrowband and for low masses the volume of the required cavity becomes prohi…
▽ More
The mass of axion dark matter is only weakly bounded by cosmological observations, necessitating a variety of detection techniques over several orders of magnitude of mass ranges. Axions haloscopes based on resonant cavities have become the current standard to search for dark matter axions. Such structures are inherently narrowband and for low masses the volume of the required cavity becomes prohibitively large. Broadband low-mass detectors have already been proposed using inductive magnetometer sensors and a gapped toroidal solenoid magnet. In this work we propose an alternative, which uses electric sensors in a conventional solenoidal magnet aligned in the laboratory z-axis, as implemented in standard haloscope experiments. In the presence of the DC magnetic field, the inverse Primakoff effect causes a time varying permanent electric vacuum polarization in the z-direction to oscillate at the axion Compton frequency, which induces an oscillating electromotive force. We propose non-resonant techniques to detect this oscillating elctromotive force by implementing a capacitive sensor or an electric dipole antenna coupled to a low noise amplifier. We present the first experimental results and discuss the foundations and potential of this proposal. Preliminary results constrain $g_{aγγ} >\sim2.35\times10^{-12}$ $\text{GeV}^{-1}$ in the mass range of $2.08\times10^{-11}$ to $2.2\times10^{-11}$ eV, and demonstrate potential sensitivity to axion-like dark matter with masses in the range of $10^{-12}$ to $10^{-8}$ eV.
△ Less
Submitted 26 October, 2018; v1 submitted 21 March, 2018;
originally announced March 2018.
-
The ORGAN Experiment: An axion haloscope above 15 GHz
Authors:
Ben T. McAllister,
Graeme Flower,
Justin Kruger,
Eugene N. Ivanov,
Maxim Goryachev,
Jeremy Bourhill,
Michael E. Tobar
Abstract:
We present first results and future plans for the Oscillating Resonant Group AxioN (ORGAN) experiment, a microwave cavity axion haloscope situated in Perth, Western Australia designed to probe for high mass axions motivated by several theoretical models. The first stage focuses around 26.6 GHz in order to directly test a claimed result, which suggests axions exist at the corresponding mass of…
▽ More
We present first results and future plans for the Oscillating Resonant Group AxioN (ORGAN) experiment, a microwave cavity axion haloscope situated in Perth, Western Australia designed to probe for high mass axions motivated by several theoretical models. The first stage focuses around 26.6 GHz in order to directly test a claimed result, which suggests axions exist at the corresponding mass of $110~μ$eV. Later stages will move to a wider scan range of 15-50 GHz ($60-210~μ$eV). We present the results of the pathfinding run, which sets a limit on $g_{aγγ}$ of $2.02\times 10^{-12} $eV$^{-1}$ at 26.531 GHz, or 110~$μ$eV, in a span of 2.5 neV (shaped by the Lorentzian resonance) with $90 \%$ confidence. Furthermore, we outline the current design and future strategies to eventually attain the sensitivity to search for well known axion models over the wider mass range.
△ Less
Submitted 12 October, 2017; v1 submitted 1 June, 2017;
originally announced June 2017.
-
High and low mass Axion Haloscopes at UWA
Authors:
Ben T. McAllister,
Stephen R. Parker,
Eugene N. Ivanov,
Michael E. Tobar
Abstract:
We consider the design of a haloscope experiment (ORGAN) to probe for axions at 26.6 GHz. The motivation for this search is to perform the first direct test of a result which claims a possible axion signal at this frequency. There are many technical issues and optimisations that must be considered in the design of a high mass axion haloscope. We discuss the current status of the ORGAN experiment,…
▽ More
We consider the design of a haloscope experiment (ORGAN) to probe for axions at 26.6 GHz. The motivation for this search is to perform the first direct test of a result which claims a possible axion signal at this frequency. There are many technical issues and optimisations that must be considered in the design of a high mass axion haloscope. We discuss the current status of the ORGAN experiment, as well as its future. We also discuss low mass axion haloscopes employing lumped 3D LC resonators.
△ Less
Submitted 24 November, 2016;
originally announced November 2016.
-
Inducing Strong Non-Linearities in a Phonon Trap** Quartz Bulk Acoustic Wave Resonator Coupled to a Superconducting Quantum Interference Device
Authors:
Maxim Goryachev,
Eugene N. Ivanov,
Serge Galliou,
Michael E. Tobar
Abstract:
A quartz Bulk Acoustic Wave resonator is designed to coherently trap phonons in a way that they are well confined and immune to suspension losses so they exhibit extremely high acoustic $Q$-factors at low temperature, with $Q\times f$ products of order $10^{18}$ Hz. In this work we couple such a resonator to a SQUID amplifier and investigate effects in the strong signal regime. Both parallel and s…
▽ More
A quartz Bulk Acoustic Wave resonator is designed to coherently trap phonons in a way that they are well confined and immune to suspension losses so they exhibit extremely high acoustic $Q$-factors at low temperature, with $Q\times f$ products of order $10^{18}$ Hz. In this work we couple such a resonator to a SQUID amplifier and investigate effects in the strong signal regime. Both parallel and series connection topologies of the system are investigated. The study reveals significant non-Duffing response that is associated with the nonlinear characteristics of Josephson junctions. The nonlinearity provides quasi-periodic structure of the spectrum in both incident power and frequency. The result gives an insight into the open loop behaviour of a future Cryogenic Quartz Oscillator in the strong signal regime.
△ Less
Submitted 4 April, 2018; v1 submitted 15 November, 2015;
originally announced November 2015.
-
Cross-correlation measurement techniques for cavity-based axion and weakly interacting slim particle searches
Authors:
Ben T. McAllister,
Stephen R. Parker,
Eugene N. Ivanov,
Michael E. Tobar
Abstract:
The search for dark matter is of fundamental importance to our understanding of the universe. Weakly-Interacting Slim Particles (WISPs) such as axions and hidden sector photons (HSPs) are well motivated candidates for the dark matter. Some of the most sensitive and mature experiments to detect WISPs rely on microwave cavities, and the detection of weak photon signals. It is often suggested to powe…
▽ More
The search for dark matter is of fundamental importance to our understanding of the universe. Weakly-Interacting Slim Particles (WISPs) such as axions and hidden sector photons (HSPs) are well motivated candidates for the dark matter. Some of the most sensitive and mature experiments to detect WISPs rely on microwave cavities, and the detection of weak photon signals. It is often suggested to power combine multiple cavities, which creates a host of technical concerns. We outline a scheme based on cross-correlation for effectively power combining cavities and increasing the signal-to-noise ratio of a candidate WISP signal.
△ Less
Submitted 6 March, 2019; v1 submitted 20 October, 2015;
originally announced October 2015.
-
Direct Terrestrial Test of Lorentz Symmetry in Electrodynamics to 10$^{-18}$
Authors:
M. Nagel,
S. R. Parker,
E. V. Kovalchuk,
P. L. Stanwix,
J. G. Hartnett,
E. N. Ivanov,
A. Peters,
M. E. Tobar
Abstract:
Lorentz symmetry is a foundational property of modern physics, underlying the standard model of particles and general relativity. It is anticipated that these two theories are low energy approximations of a single theory that is unified and consistent at the Planck scale. Many unifying proposals allow Lorentz symmetry to be broken, with observable effects appearing at Planck-suppressed levels; thu…
▽ More
Lorentz symmetry is a foundational property of modern physics, underlying the standard model of particles and general relativity. It is anticipated that these two theories are low energy approximations of a single theory that is unified and consistent at the Planck scale. Many unifying proposals allow Lorentz symmetry to be broken, with observable effects appearing at Planck-suppressed levels; thus precision tests of Lorentz invariance are needed to assess and guide theoretical efforts. Here, we use ultra-stable oscillator frequency sources to perform a modern Michelson-Morley experiment and make the most precise direct terrestrial test to date of Lorentz symmetry for the photon, constraining Lorentz violating orientation-dependent relative frequency changes $Δν$/$ν$ to 9.2$\pm$10.7$\times10^{-19}$ (95$\%$ confidence interval). This order of magnitude improvement over previous Michelson-Morley experiments allows us to set comprehensive simultaneous bounds on nine boost and rotation anisotropies of the speed of light, finding no significant violations of Lorentz symmetry.
△ Less
Submitted 14 September, 2015; v1 submitted 22 December, 2014;
originally announced December 2014.
-
Extending the frequency range of digital noise measurements to the microwave domain
Authors:
Stephen R. Parker,
Eugene N. Ivanov,
John G. Hartnett
Abstract:
We describe the use of digital phase noise test sets at frequencies well beyond the sampling rate of their analog-to-digital converters. The technique proposed involves the transfer of phase fluctuations from an arbitrary high carrier frequency to within the operating frequency range of the digital instrument. The validity of the proposed technique has been proven via comparison with conventional…
▽ More
We describe the use of digital phase noise test sets at frequencies well beyond the sampling rate of their analog-to-digital converters. The technique proposed involves the transfer of phase fluctuations from an arbitrary high carrier frequency to within the operating frequency range of the digital instrument. The validity of the proposed technique has been proven via comparison with conventional methods. Digital noise measurements eliminate the need for calibration and improve consistency of experimental results. Mechanisms limiting the resolution of spectral measurements are also discussed.
△ Less
Submitted 20 October, 2014;
originally announced October 2014.
-
Observation of the Fundamental Nyquist Noise Limit in an Ultra-High $Q$-Factor Cryogenic Bulk Acoustic Wave Cavity
Authors:
Maxim Goryachev,
Eugene N. Ivanov,
Frank van Kann,
Serge Galliou,
Michael E. Tobar
Abstract:
Thermal Nyquist noise fluctuations of high-$Q$ Bulk Acoustic Wave (BAW) cavities have been observed at cryogenic temperatures with a DC Superconducting Quantum Interference Device (SQUID) amplifier. High $Q$ modes with bandwidths of few tens of milliHz produce thermal fluctuations with a Signal-To-Noise ratio of up to 23dB. The estimated effective temperature from the Nyquist noise is in good agre…
▽ More
Thermal Nyquist noise fluctuations of high-$Q$ Bulk Acoustic Wave (BAW) cavities have been observed at cryogenic temperatures with a DC Superconducting Quantum Interference Device (SQUID) amplifier. High $Q$ modes with bandwidths of few tens of milliHz produce thermal fluctuations with a Signal-To-Noise ratio of up to 23dB. The estimated effective temperature from the Nyquist noise is in good agreement with the physical temperature of the device, confirming the validity of the equivalent circuit model and the non-existence of any excess resonator self-noise. The measurements also confirm that the quality factor remains extremely high ($Q>10^8$ at low order overtones) for very weak (thermal) system motion at low temperatures, when compared to values measured with relatively strong external excitation. This result represents an enabling step towards operating such a high-Q acoustic device at the standard quantum limit.
△ Less
Submitted 16 October, 2014;
originally announced October 2014.
-
Extremely high-resolution measurements of microwave magnetisation dynamics in magnetic thin films and nanostructures
Authors:
Eugene N. Ivanov,
Mikhail Kostylev
Abstract:
In this work we discuss the use of interferometric measurement technique to study microwave magnetization dynamics on ferromagnetic nanostructures. We demonstrate that in this way one can resolve features which are impossible to resolve with broadband ferromagnetic resonance and traveling spin wave spectroscopy otherwise.
In this work we discuss the use of interferometric measurement technique to study microwave magnetization dynamics on ferromagnetic nanostructures. We demonstrate that in this way one can resolve features which are impossible to resolve with broadband ferromagnetic resonance and traveling spin wave spectroscopy otherwise.
△ Less
Submitted 14 February, 2014;
originally announced February 2014.
-
Anomalously Strong Nonlinearity of Unswept Quartz Acoustic Cavities at Liquid Helium Temperatures
Authors:
M. Goryachev,
Warrick G. Farr,
Eugene N. Ivanov,
Michael E. Tobar
Abstract:
We demonstrate a variety of nonlinear phenomena at extremely low powers in cryogenic acoustic cavities fabricated from quartz material, which have not undergone any electrodiffusion processes. Nonlinear phenomena observed include lineshape discontinuities, power response discontinuities, quadrature oscillations and self-induced transparency. These phenomena are attributed to nonlinear dissipation…
▽ More
We demonstrate a variety of nonlinear phenomena at extremely low powers in cryogenic acoustic cavities fabricated from quartz material, which have not undergone any electrodiffusion processes. Nonlinear phenomena observed include lineshape discontinuities, power response discontinuities, quadrature oscillations and self-induced transparency. These phenomena are attributed to nonlinear dissipation through a large number of randomly distributed heavy trapped ions, which would normally be removed by electrodiffusion. A simple mean-field model predicts most of the observed phenomena. In contrast to Duffing-like systems, this system shows an unusual mechanism of nonlinearity, which is not related to crystal anharmonisity.
△ Less
Submitted 20 September, 2013;
originally announced September 2013.
-
Rigorous analysis of highly tunable cylindrical Transverse Magnetic mode re-entrant cavities
Authors:
J-M. Le Floch,
Y. Fan,
M. Aubourg,
D. Cros,
N. C. Carvalho,
Q. Shan,
J. Bourhill,
E. N. Ivanov,
G. Humbert,
V. Madrangeas,
M. E. Tobar
Abstract:
Cylindrical re-entrant cavities are unique three-dimensional structures that resonate with their electric and magnetic fields in separate parts of the cavity. To further understand these devices, we undertake rigorous analysis of the properties of the resonance using in-house developed Finite Element Method (FEM) software capable of dealing with small gap structures of extreme aspect ratio. Compar…
▽ More
Cylindrical re-entrant cavities are unique three-dimensional structures that resonate with their electric and magnetic fields in separate parts of the cavity. To further understand these devices, we undertake rigorous analysis of the properties of the resonance using in-house developed Finite Element Method (FEM) software capable of dealing with small gap structures of extreme aspect ratio. Comparisons between the FEM method and experiments are consistent and we illustrate where predictions using established lumped element models work well and where they are limited. With the aid of the modeling we design a highly tunable cavity that can be tuned from 2 GHz to 22 GHz just by inserting a post into a fixed dimensioned cylindrical cavity. We show this is possible as the mode structure transforms from a re-entrant mode during the tuning process to a standard cylindrical Transverse Magnetic (TM) mode.
△ Less
Submitted 8 January, 2014; v1 submitted 13 August, 2013;
originally announced August 2013.
-
Resonator Power to Frequency Conversion in a Cryogenic Sapphire Oscillator
Authors:
Nitin R. Nand,
Stephen R. Parker,
Eugene N. Ivanov,
Jean-Michel le-Floch,
John G. Hartnett,
Michael E. Tobar
Abstract:
We report on the measurement and characterization of power to frequency conversion in the resonant mode of a cryogenic sapphire loaded cavity resonator, which is used as the frequency discriminating element of a loop oscillator circuit. Fluctuations of power incident on the resonator leads to changes in radiation pressure and temperature in the sapphire dielectric, both of which contribute to a sh…
▽ More
We report on the measurement and characterization of power to frequency conversion in the resonant mode of a cryogenic sapphire loaded cavity resonator, which is used as the frequency discriminating element of a loop oscillator circuit. Fluctuations of power incident on the resonator leads to changes in radiation pressure and temperature in the sapphire dielectric, both of which contribute to a shift in the resonance frequency. We measure a modulation and temperature independent radiation pressure induced power to frequency sensitivity of -0.15 Hz/mW and find that this is the primary factor limiting the stability of the resonator frequency.
△ Less
Submitted 23 July, 2013;
originally announced July 2013.
-
Comparison of ultra-stable radio frequency signals synthesized from independent secondary microwave frequency standards
Authors:
John G. Hartnett,
Stephen R. Parker,
Eugene N. Ivanov,
Travis Povey,
Nitin R. Nand,
Jean-Michel le Floch
Abstract:
The phase noise and frequency stability measurements of 1 GHz, 100 MHz, and 10 MHz signals are presented which have been synthesized from microwave cryogenic sapphire oscillators using ultra-low-vibration pulse-tube cryocooler technology. We present the measured data using independent cryogenic oscillators for the 100 MHz and 10 MHz synthesized signals, whereas previously we only estimated the exp…
▽ More
The phase noise and frequency stability measurements of 1 GHz, 100 MHz, and 10 MHz signals are presented which have been synthesized from microwave cryogenic sapphire oscillators using ultra-low-vibration pulse-tube cryocooler technology. We present the measured data using independent cryogenic oscillators for the 100 MHz and 10 MHz synthesized signals, whereas previously we only estimated the expected results based on residual phase noise measurements, when only one cryogenic oscillator was available. In addition we present the design of a 1 GHz synthesizer using a Crystek voltage controlled oscillator phase locked to 1 GHz output derived from a cryogenic sapphire oscillator.
△ Less
Submitted 31 January, 2013;
originally announced February 2013.
-
Extremely Low-Loss Acoustic Phonons in a Quartz Bulk Acoustic Wave Resonator at Millikelvin Temperature
Authors:
Maxim Goryachev,
Daniel L. Creedon,
Eugene N. Ivanov,
Serge Galliou,
Roger Bourquin,
Michael E. Tobar
Abstract:
Low-loss, high frequency acoustic resonators cooled to millikelvin temperatures are a topic of great interest for application to hybrid quantum systems. When cooled to 20 mK, we show that resonant acoustic phonon modes in a Bulk Acoustic Wave (BAW) quartz resonator demonstrate exceptionally low loss (with $Q$-factors of order billions) at frequencies of 15.6 and 65.4 MHz, with a maximum $f.Q$ prod…
▽ More
Low-loss, high frequency acoustic resonators cooled to millikelvin temperatures are a topic of great interest for application to hybrid quantum systems. When cooled to 20 mK, we show that resonant acoustic phonon modes in a Bulk Acoustic Wave (BAW) quartz resonator demonstrate exceptionally low loss (with $Q$-factors of order billions) at frequencies of 15.6 and 65.4 MHz, with a maximum $f.Q$ product of 7.8$\times10^{16}$ Hz. Given this result, we show that the $Q$-factor in such devices near the quantum ground state can be four orders of magnitude better than previously attained. Such resonators possess the low losses crucial for electromagnetic cooling to the phonon ground state, and the possibility of long coherence and interaction times of a few seconds, allowing multiple quantum gate operations.
△ Less
Submitted 1 April, 2012; v1 submitted 21 February, 2012;
originally announced February 2012.
-
Ultra stable and very low noise signal source using a cryocooled sapphire oscillator for VLBI
Authors:
Nitin R. Nand,
John G. Hartnett,
Eugene N. Ivanov,
Giorgio Santarelli
Abstract:
Here we present the design and implementation of a novel frequency synthesizer based on low phase noise digital dividers and a direct digital synthesizer. The synthesis produces two low noise accurate and tunable signals at 10 MHz and 100 MHz. We report on the measured residual phase noise and frequency stability of the synthesizer, and estimate the total frequency stability, which can be expected…
▽ More
Here we present the design and implementation of a novel frequency synthesizer based on low phase noise digital dividers and a direct digital synthesizer. The synthesis produces two low noise accurate and tunable signals at 10 MHz and 100 MHz. We report on the measured residual phase noise and frequency stability of the synthesizer, and estimate the total frequency stability, which can be expected from the synthesizer seeded with a signal near 11.2 GHz from an ultra-stable cryocooled sapphire oscillator.
The synthesizer residual single sideband phase noise, at 1 Hz offset, on 10 MHz and 100 MHz signals, respectively, were measured to be -135 dBc/Hz and -130 dBc/Hz. Their intrinsic frequency stability contributions, on the 10 MHz and 100 MHz signals, respectively, were measured as sigma_y = 9 x 10^-15 and sigma_y = 2.2 x 10^-15, at 1 s integration time.
The Allan Deviation of the total fractional frequency noise on the 10 MHz and 100 MHz signals derived from the synthesizer with the cryocooled sapphire oscillator, may be estimated as sigma_y = 5.2 x 10^-15 τ^-1 + 3.6 x 10^-15 τ^-1/2 + 4 x 10^-16 and sigma_y = 2 x 10^-15 τ^-1/2 + 3 x 10^-16, respectively, for 1 s < τ< 10^4 s.
We also calculate the coherence function, (a figure of merit in VLBI) for observation frequencies of 100 GHz, 230 GHz and 345 GHz, when using the cryocooled sapphire oscillator and an hydrogen maser. The results show that the cryocooled sapphire oscillator offers a significant advantage at frequencies above 100 GHz.
△ Less
Submitted 20 April, 2011;
originally announced April 2011.
-
High Resolution Flicker-Noise-Free Frequency Measurements of Weak Microwave Signals
Authors:
Daniel L. Creedon,
Michael E. Tobar,
Eugene N. Ivanov,
John G. Hartnett
Abstract:
Amplification is usually necessary when measuring the frequency instability of microwave signals. In this work, we develop a flicker noise free frequency measurement system based on a common or shared amplifier. First, we show that correlated flicker phase noise can be cancelled in such a system. Then we compare the new system with the conventional by simultaneously measuring the beat frequency fr…
▽ More
Amplification is usually necessary when measuring the frequency instability of microwave signals. In this work, we develop a flicker noise free frequency measurement system based on a common or shared amplifier. First, we show that correlated flicker phase noise can be cancelled in such a system. Then we compare the new system with the conventional by simultaneously measuring the beat frequency from two cryogenic sapphire oscillators with parts in 10^15 fractional frequency instability. We determine for low power, below -80 dBm, the measurements were not limited by correlated noise processes but by thermal noise of the readout amplifier. In this regime, we show that the new readout system performs as expected and at the same level as the standard system but with only half the number of amplifiers. We also show that, using a standard readout system, the next generation of cryogenic sapphire oscillators could be flicker phase noise limited when instability reaches parts in 10^16 or better
△ Less
Submitted 17 April, 2011;
originally announced April 2011.
-
Rotating Odd-Parity Lorentz Invariance Test in Electrodynamics
Authors:
Michael E. Tobar,
Eugene N. Ivanov,
Paul L. Stanwix,
Jean-Michel G. le Floch,
John G. Hartnett
Abstract:
We report the first operation of a rotating odd-parity Lorentz Invariance test in electrodynamics using a microwave Mach-Zehnder interferometer with permeable material in one arm. The experiment sets a direct bound to $ κ_{tr}$ of $-0.3\pm 3\times10^{-7}$. Using new power recycled waveguide interferometer techniques (with the highest spectral resolution ever achieved of…
▽ More
We report the first operation of a rotating odd-parity Lorentz Invariance test in electrodynamics using a microwave Mach-Zehnder interferometer with permeable material in one arm. The experiment sets a direct bound to $ κ_{tr}$ of $-0.3\pm 3\times10^{-7}$. Using new power recycled waveguide interferometer techniques (with the highest spectral resolution ever achieved of $2\times10^{-11} rad/\sqrt{Hz}$) we show an improvement of several orders of magnitude is attainable in the future.
△ Less
Submitted 24 November, 2009; v1 submitted 10 September, 2009;
originally announced September 2009.
-
Microwave Phase Detection at the Level of $10^{-11}$ rad
Authors:
Eugene Nicolay Ivanov,
Michael Edmund Tobar
Abstract:
We report on a noise measurement system with the highest spectral resolution ever achieved in the microwave domain. It is capable of detecting the phase fluctuations of $rms$ amplitude of $2\times10^{-11} rad/\sqrt{Hz}$ at Fourier frequencies above few $kHz$. Such precision allows the study of intrinsic fluctuations in various microwave components and materials, as well as precise tests of funda…
▽ More
We report on a noise measurement system with the highest spectral resolution ever achieved in the microwave domain. It is capable of detecting the phase fluctuations of $rms$ amplitude of $2\times10^{-11} rad/\sqrt{Hz}$ at Fourier frequencies above few $kHz$. Such precision allows the study of intrinsic fluctuations in various microwave components and materials, as well as precise tests of fundamental physics. Employing this system we discovered a previously unknown phenomenon of down-conversion of pump oscillator phase noise into the low-frequency voltage fluctuations.
△ Less
Submitted 1 April, 2009;
originally announced April 2009.
-
Improved test of Lorentz Invariance in Electrodynamics using Rotating Cryogenic Sapphire Oscillators
Authors:
Paul L. Stanwix,
Michael E. Tobar,
Peter Wolf,
Clayton R. Locke,
Eugene N. Ivanov
Abstract:
We present new results from our test of Lorentz invariance, which compares two orthogonal cryogenic sapphire microwave oscillators rotating in the lab. We have now acquired over 1 year of data, allowing us to avoid the short data set approximation (less than 1 year) that assumes no cancelation occurs between the $\tildeκ_{e-}$ and $\tildeκ_{o+}$ parameters from the photon sector of the standard…
▽ More
We present new results from our test of Lorentz invariance, which compares two orthogonal cryogenic sapphire microwave oscillators rotating in the lab. We have now acquired over 1 year of data, allowing us to avoid the short data set approximation (less than 1 year) that assumes no cancelation occurs between the $\tildeκ_{e-}$ and $\tildeκ_{o+}$ parameters from the photon sector of the standard model extension. Thus, we are able to place independent limits on all eight $\tildeκ_{e-}$ and $\tildeκ_{o+}$ parameters. Our results represents up to a factor of 10 improvement over previous non rotating measurements (which independently constrained 7 parameters), and is a slight improvement (except for $\tildeκ_{e-}^{ZZ}$) over results from previous rotating experiments that assumed the short data set approximation. Also, an analysis in the Robertson-Mansouri-Sexl framework allows us to place a new limit on the isotropy parameter $P_{MM}=δ-β+{1/2}$ of $9.4(8.1)\times10^{-11}$, an improvement of a factor of 2.
△ Less
Submitted 3 October, 2006; v1 submitted 19 September, 2006;
originally announced September 2006.
-
Long Term Operation and Performance of Cryogenic Sapphire Oscillators
Authors:
M. E. Tobar,
E. N. Ivanov,
C. R. Locke,
P. L. Stanwix,
J. G. Hartnett,
A. N. Luiten,
R. B. Warrington,
P. T. H. Fisk,
M. A. Lawn,
M. J. Wouters,
S. Bize,
G. Santarelli,
P. Wolf,
A. Clairon,
P. Guillemot
Abstract:
Cryogenic Sapphire Oscillators (CSO) developed at UWA have now been in operation around the world continuously for many years. Such oscillators, due to their excellent spectral purity are essential for interrogating atomic frequency standards at the limit of quantum projection noise; otherwise aliasing effects will dominate the frequency stability due to the periodic sampling between successive…
▽ More
Cryogenic Sapphire Oscillators (CSO) developed at UWA have now been in operation around the world continuously for many years. Such oscillators, due to their excellent spectral purity are essential for interrogating atomic frequency standards at the limit of quantum projection noise; otherwise aliasing effects will dominate the frequency stability due to the periodic sampling between successive interrogations of the atomic transition. For this reason, UWA oscillators are now operational at NMI (Sydney), LNE-SYRTE (Paris), the French Space Agency (CNES, Toulouse) and at UWA (Perth). Other applications, which have attracted attention in recent years, include tests on fundamental principles of physics, such as tests of Lorentz invariance. This paper reports on the long-term operation and performance of such oscillators. We compare the long-term drift of some different CSOs. The drift rates turn out to be linear over many years and in the same direction. However, the magnitude seems to vary by more than one order of magnitude between the oscillators, ranging from 10^14 per day to a few parts in 10^13 per day.
△ Less
Submitted 19 August, 2006;
originally announced August 2006.
-
Cryogenic sapphire oscillator with exceptionally high long-term frequency stability
Authors:
J. G. Hartnett,
C. R. Locke,
E. N. Ivanov,
M. E. Tobar,
P. L. Stanwix
Abstract:
We report on the development of a sapphire cryogenic microwave resonator oscillator long-term fractional frequency stability of 2x10^-17Sqrt[τ] for integration times τ>10^3 s and negative drift of about 2.2x10^-15/day. The short-term frequency instability of the oscillator is highly reproducible and also state-of-the-art: 5.6x10^-16 for an integration time of τ~ 20 s.
We report on the development of a sapphire cryogenic microwave resonator oscillator long-term fractional frequency stability of 2x10^-17Sqrt[τ] for integration times τ>10^3 s and negative drift of about 2.2x10^-15/day. The short-term frequency instability of the oscillator is highly reproducible and also state-of-the-art: 5.6x10^-16 for an integration time of τ~ 20 s.
△ Less
Submitted 3 October, 2006; v1 submitted 11 August, 2006;
originally announced August 2006.
-
Rotating Resonator-Oscillator Experiments to Test Lorentz Invariance in Electrodynamics
Authors:
Michael E. Tobar,
Paul L. Stanwix,
Mohamad Susli,
Peter Wolf,
Clayton R. Locke,
Eugene N. Ivanov
Abstract:
In this work we outline the two most commonly used test theories (RMS and SME) for testing Local Lorentz Invariance (LLI) of the photon. Then we develop the general framework of applying these test theories to resonator experiments with an emphasis on rotating experiments in the laboratory. We compare the inherent sensitivity factors of common experiments and propose some new configurations. Fin…
▽ More
In this work we outline the two most commonly used test theories (RMS and SME) for testing Local Lorentz Invariance (LLI) of the photon. Then we develop the general framework of applying these test theories to resonator experiments with an emphasis on rotating experiments in the laboratory. We compare the inherent sensitivity factors of common experiments and propose some new configurations. Finally we apply the test theories to the rotating cryogenic experiment at the University of Western Australia, which recently set new limits in both the RMS and SME frameworks [hep-ph/0506074].
△ Less
Submitted 17 October, 2005; v1 submitted 21 June, 2005;
originally announced June 2005.
-
Test of Lorentz Invariance in Electrodynamics Using Rotating Cryogenic Sapphire Microwave Oscillators
Authors:
Paul L. Stanwix,
Michael E. Tobar,
Peter Wolf,
Mohamad Susli,
Clayton R. Locke,
Eugene N. Ivanov,
John Winterflood,
Frank van Kann
Abstract:
We present the first results from a rotating Michelson-Morley experiment that uses two orthogonally orientated cryogenic sapphire resonator-oscillators operating in whispering gallery modes near 10 GHz. The experiment is used to test for violations of Lorentz Invariance in the frame-work of the photon sector of the Standard Model Extension (SME), as well as the isotropy term of the Robertson-Man…
▽ More
We present the first results from a rotating Michelson-Morley experiment that uses two orthogonally orientated cryogenic sapphire resonator-oscillators operating in whispering gallery modes near 10 GHz. The experiment is used to test for violations of Lorentz Invariance in the frame-work of the photon sector of the Standard Model Extension (SME), as well as the isotropy term of the Robertson-Mansouri-Sexl (RMS) framework. In the SME we set a new bound on the previously unmeasured $\tildeκ_{e-}^{ZZ}$ component of $2.1(5.7)\times10^{-14}$, and set more stringent bounds by up to a factor of 7 on seven other components. In the RMS a more stringent bound of $-0.9(2.0)\times 10^{-10}$ on the isotropy parameter, $P_{MM}=δ- β+ {1/2}$ is set, which is more than a factor of 7 improvement. More detailed description of the experiment and calculations can be found in: hep-ph/0506200
△ Less
Submitted 21 July, 2005; v1 submitted 7 June, 2005;
originally announced June 2005.
-
Properties of a monolithic sapphire parametric transducer: prospects of measuring the standard quantum limit
Authors:
C. R. Locke,
M. E. Tobar,
E. N. Ivanov
Abstract:
To measure the standard quantum limit (SQL) a high quality transducer must be coupled to a high quality mechanical system. Due to its monolithic nature, the monolithic sapphire transducer (MST) has high quality factors for both types of resonances. Single loop suspension is shown to yield a mechanical quality factor of 6.10^8 at 4 K. From standard analysis we show the MST has the potential to me…
▽ More
To measure the standard quantum limit (SQL) a high quality transducer must be coupled to a high quality mechanical system. Due to its monolithic nature, the monolithic sapphire transducer (MST) has high quality factors for both types of resonances. Single loop suspension is shown to yield a mechanical quality factor of 6.10^8 at 4 K. From standard analysis we show the MST has the potential to measure noise fluctuations of the mechanical oscillator at the SQL. also, we point out a new way to determine if the transducer back action is quantum limited. We show that if the fluctuations are at the quantum limit, then the amplitude of the oscillation will be amplified by the ratio of the ringdown time to the measurement time, which is an inherently easier measurement.
△ Less
Submitted 19 July, 2002;
originally announced July 2002.
-
Initial operation of the International Gravitational Event Collaboration
Authors:
G. A. Prodi,
I. S. Heng,
Z. A. Allen,
P. Astone,
L. Baggio,
M. Bassan,
D. G. Blair,
M. Bonaldi,
P. Bonifazi,
P. Carelli,
M. Cerdonio,
E. Coccia,
L. Conti,
C. Cosmelli,
V. Crivelli Visconti,
S. D'Antonio,
V. Fafone,
P. Falferi,
P. Fortini,
S. Frasca,
W. O. Hamilton,
E. N. Ivanov,
W. W. Johnson,
C. R. Locke,
A. Marini
, et al. (24 additional authors not shown)
Abstract:
The International Gravitational Event Collaboration, IGEC, is a coordinated effort by research groups operating gravitational wave detectors working towards the detection of millisecond bursts of gravitational waves. Here we report on the current IGEC resonant bar observatory, its data analysis procedures, the main properties of the first exchanged data set. Even though the available data set is…
▽ More
The International Gravitational Event Collaboration, IGEC, is a coordinated effort by research groups operating gravitational wave detectors working towards the detection of millisecond bursts of gravitational waves. Here we report on the current IGEC resonant bar observatory, its data analysis procedures, the main properties of the first exchanged data set. Even though the available data set is not complete, in the years 1997 and 1998 up to four detectors were operating simultaneously. Preliminary results are mentioned.
△ Less
Submitted 8 March, 2000;
originally announced March 2000.