Parasitic neutron beam monitoring: proof of concept on gamma monitoring of neutron chopper phases
Authors:
F. Issa,
R. Hall-Wilton,
A. Quintanilla,
M. Olsson,
D. Zielinski,
K. Kanaki,
N. Tsapatsaris
Abstract:
Neutron beam monitors are an essential diagnostic component of neutron scattering facilities. They are used to measure neutron flux, calibrating experiments performed on the instruments, allowing measurement of facility performance, understanding of the effect on the neutrons of beam-line components (such as choppers), calibration of detectors and tracking of beam stability. Ideally beam monitors…
▽ More
Neutron beam monitors are an essential diagnostic component of neutron scattering facilities. They are used to measure neutron flux, calibrating experiments performed on the instruments, allowing measurement of facility performance, understanding of the effect on the neutrons of beam-line components (such as choppers), calibration of detectors and tracking of beam stability. Ideally beam monitors {should} not perturb the beam. Previous work shows commercial beam monitors attenuate the beam by a few percent in the worst case due to the 1-2 mm thick Aluminium entrance and exit windows and the material inside. Parasitic methods of neutron beam diagnostics, where there is no beam monitor directly in the beam, would be preferable. This paper presents the concept of a parasitic method of monitoring the beam which can be used for neutron chopper phasing. This is achieved by placing a gamma detector close to a rotating chopper and measures a signal proportional to the flux absorbed by the chopper. Neutrons interact with the Boron absorber on the chopper disc lead to gamma emission at 480 keV. Detection of these gamma rays is used to determine the chopper phasing and timing. Potentially information on the flux of the beamline can be extracted. Results from a proof of concept implementation show that diagnosis of neutron chopper phases is feasible.
△ Less
Submitted 11 November, 2020; v1 submitted 15 April, 2020;
originally announced April 2020.
-
Vanadium-based neutron Beam Monitor
Authors:
Vendula Maulerova,
Kalliopi Kanaki,
Peter Kadletz,
Robin Woracek,
Thomas Wilpert,
Kevin Fissum,
Alessio Laloni,
Nicholai Mauritzson,
Fatima Issa,
Richard Hall-Wilton
Abstract:
A prototype quasi-parasitic thermal neutron beam monitor based on isotropic neutron scattering from a thin natural vanadium foil and standard $^3$He proportional counters is conceptualized, designed, simulated, calibrated, and commissioned. The European Spallation Source designed to deliver the highest integrated neutron flux originating from a pulsed source is currently under construction in Lund…
▽ More
A prototype quasi-parasitic thermal neutron beam monitor based on isotropic neutron scattering from a thin natural vanadium foil and standard $^3$He proportional counters is conceptualized, designed, simulated, calibrated, and commissioned. The European Spallation Source designed to deliver the highest integrated neutron flux originating from a pulsed source is currently under construction in Lund, Sweden. The effort to investigate a vanadium-based neutron beam monitor was triggered by a list of requirements for Beam Monitors permanently placed in the ESS neutron beams in order to provide reliable monitoring at complex beamlines: low attenuation, linear response over a wide range of neutron fluxes, near to constant efficiency for neutron wavelengths in a range of 0.6-10 Å, calibration stability and the possibility to place the system in vacuum are all desirable characteristics. The scattering-based prototype, employing a natural vanadium foil and standard $^3$He proportional counters, was investigated at the V17 and V20 neutron beamlines of the Helmholtz-Zentrum in Berlin, Germany, in several different geometrical configurations of the $^3$He proportional counters around the foil. Response linearity is successfully demonstrated for foil thicknesses ranging from 0.04 mm to 3.15 mm. Attenuation lower than 1% for thermal neutrons is demonstrated for the 0.04 mm and 0.125 mm foils. The geometries used for the experiment were simulated allowing for absolute flux calibration and establishing the possible range of efficiencies for various designs of the prototype. The operational flux limits for the beam monitor prototype were established as a dependency of the background radiation and prototype geometry. The herein demonstrated prototype monitors can be employed for neutron fluxes ranging from $10^3-10^{10}$ n/s/cm$^2$.
△ Less
Submitted 24 February, 2020;
originally announced February 2020.
-
First neutron data recorded at the V20 Test Instrument utilizing prototype chopper systems and beam monitors planned for ESS
Authors:
V. Maulerova,
J. Nilsson,
M. Olsson,
S. Alcock,
A. Quintanilla,
D. Zielinski,
A. Mukai,
F. Issa,
S. Kolya,
W. Smith,
D. Broderick,
K. Löki,
J. Sparger,
R. Woracek,
J. Taylor,
T. Richter,
R. Hall-Wilton,
O. Kirstein,
N. Tsapatsaris
Abstract:
The main objective of the European Spallation Source (ESS) is to perform consistently high impact neutron scattering science using the highest neutron flux of any facility in its class. This ambition is naturally accompanied by operational challenges related to the vertical integration of the instruments' hardware and software shared between collaborators from 13 European countries. The present wo…
▽ More
The main objective of the European Spallation Source (ESS) is to perform consistently high impact neutron scattering science using the highest neutron flux of any facility in its class. This ambition is naturally accompanied by operational challenges related to the vertical integration of the instruments' hardware and software shared between collaborators from 13 European countries. The present work will detail integration tests performed at the V20 Test Instrument at Helmholtz-Zentrum Berlin in Germany. An ESS chopper prototype was successfully controlled through the ESS Chopper Integration Controller (CHIC) and Experimental Physics and Industrial Control System (EPICS). Neutron data were successfully collected and time stamped using neutron beam monitors, the ESS prototype detector readout electronics and the Data Management Software Center (DMSC) data acquisition (DAQ) software. Chopper rotation events were timestamped and the chopper disk showed excellent stability and neutron absorption characteristics. The test resulted in (i) the expected time-of-flight (TOF) response, (ii) collected data that compared well with instrument reference data and (iii) revealing the diagnostic power of the performed integration tests. The results of this integration test validate the ESS chopper and detector DAQ architecture choices.
△ Less
Submitted 21 August, 2019;
originally announced August 2019.
-
The neutron tagging facility at Lund University
Authors:
F. Messi,
H. Perrey,
K. Fissum,
M. Akkawi,
R. Al Jebali,
J. R. M. Annand,
P. Bentley,
L. Boyd,
C. P. Cooper-Jensen,
D. D. DiJulio,
J. Freita-Ramos,
R. Hall-Wilton,
A. Huusko,
T. Ilves,
F. Issa,
A. Jalgén,
K. Kanaki,
E. Karnickis,
A. Khaplanov,
S. Koufigar,
V. Maulerova,
G. Mauri,
N. Mauritzson,
W. Pei,
F. Piscitelli
, et al. (5 additional authors not shown)
Abstract:
Over the last decades, the field of thermal neutron detection has overwhelmingly employed He-3-based technologies. The He-3 crisis together with the forthcoming establishment of the European Spallation Source have necessitated the development of new technologies for neutron detection. Today, several promising He-3-free candidates are under detailed study and need to be validated. This validation p…
▽ More
Over the last decades, the field of thermal neutron detection has overwhelmingly employed He-3-based technologies. The He-3 crisis together with the forthcoming establishment of the European Spallation Source have necessitated the development of new technologies for neutron detection. Today, several promising He-3-free candidates are under detailed study and need to be validated. This validation process is in general long and expensive. The study of detector prototypes using neutron-emitting radioactive sources is a cost-effective solution, especially for preliminary investigations. That said, neutron-emitting sources have the general disadvantage of broad, structured, emitted-neutron energy ranges. Further, the emitted neutrons often compete with unwanted backgrounds of gamma-rays, alpha-particles, and fission-fragments. By blending experimental infrastructure such as shielding to provide particle beams with neutron-detection techniques such as tagging, disadvantages may be converted into advantages. In particular, a technique known as tagging involves exploiting the mixed-field generally associated with a neutron-emitting source to determine neutron time-of-flight and thus energy on an event-by-event basis. This allows for the definition of low-cost, precision neutron beams. The Source-Testing Facility, located at Lund University in Sweden and operated by the SONNIG Group of the Division of Nuclear Physics, was developed for just such low-cost studies. Precision tagged-neutron beams derived from radioactive sources are available around-the-clock for advanced detector diagnostic studies. Neutron measurements performed at the Source Testing Facility are thus cost-effective and have a very low barrier for entry. In this paper, we present an overview of the project.
△ Less
Submitted 28 November, 2017;
originally announced November 2017.
-
Multi-Grid Detector for Neutron Spectroscopy: Results Obtained on Time-of-Flight Spectrometer CNCS
Authors:
M. Anastasopoulos,
R. Bebb,
K. Berry,
J. Birch,
T. Bryś,
J. -C. Buffet,
J. -F. Clergeau,
P. P. Deen,
G. Ehlers,
P. van Esch,
S. M. Everett,
B. Guerard,
R. Hall-Wilton,
K. Herwig,
L. Hultman,
C. Höglund,
I. Iruretagoiena,
F. Issa,
J. Jensen,
A. Khaplanov,
O. Kirstein,
I. Lopez-Higuera,
F. Piscitelli,
L. Robinson,
S. Schmidt
, et al. (1 additional authors not shown)
Abstract:
The Multi-Grid detector technology has evolved from the proof-of-principle and characterisation stages. Here we report on the performance of the Multi-Grid detector, the MG.CNCS prototype, which has been installed and tested at the Cold Neutron Chopper Spectrometer, CNCS at SNS. This has allowed a side-by-side comparison to the performance of $^3$He detectors on an operational instrument. The demo…
▽ More
The Multi-Grid detector technology has evolved from the proof-of-principle and characterisation stages. Here we report on the performance of the Multi-Grid detector, the MG.CNCS prototype, which has been installed and tested at the Cold Neutron Chopper Spectrometer, CNCS at SNS. This has allowed a side-by-side comparison to the performance of $^3$He detectors on an operational instrument. The demonstrator has an active area of 0.2 m$^2$. It is specifically tailored to the specifications of CNCS. The detector was installed in June 2016 and has operated since then, collecting neutron scattering data in parallel to the He-3 detectors of CNCS. In this paper, we present a comprehensive analysis of this data, in particular on instrument energy resolution, rate capability, background and relative efficiency. Stability, gamma-ray and fast neutron sensitivity have also been investigated. The effect of scattering in the detector components has been measured and provides input to comparison for Monte Carlo simulations. All data is presented in comparison to that measured by the $^3$He detectors simultaneously, showing that all features recorded by one detector are also recorded by the other. The energy resolution matches closely. We find that the Multi-Grid is able to match the data collected by $^3$He, and see an indication of a considerable advantage in the count rate capability. Based on these results, we are confident that the Multi-Grid detector will be capable of producing high quality scientific data on chopper spectrometers utilising the unprecedented neutron flux of the ESS.
△ Less
Submitted 3 April, 2017; v1 submitted 10 March, 2017;
originally announced March 2017.
-
Characterization of Thermal Neutron Beam Monitors
Authors:
F. Issa,
A. Khaplanov,
R. Hall-Wilton,
I. Llamas,
M. Dalseth Riktor,
S. R. Brattheim,
H. Perrey
Abstract:
Neutron beam monitors with high efficiency, low gamma sensitivity, high time and space resolution are required in neutron beam experiments to continuously diagnose the delivered beam. In this work, commercially available neutron beam monitors have been characterized using the R2D2 beamline at IFE (Norway) and using a Be-based neutron source. For the gamma sensitivity measurements different gamma s…
▽ More
Neutron beam monitors with high efficiency, low gamma sensitivity, high time and space resolution are required in neutron beam experiments to continuously diagnose the delivered beam. In this work, commercially available neutron beam monitors have been characterized using the R2D2 beamline at IFE (Norway) and using a Be-based neutron source. For the gamma sensitivity measurements different gamma sources have been used. The evaluation of the monitors includes, the study of their efficiency, attenuation, scattering and sensitivity to gamma. In this work we report the results of this characterization.
△ Less
Submitted 3 February, 2017;
originally announced February 2017.