Experimental studies on the charge transfer inefficiency of CCD developed for the soft X-ray imaging telescope Xtend aboard the XRISM satellite
Authors:
Yoshiaki Kanemaru,
** Sato,
Toshiyuki Takaki,
Yuta Terada,
Koji Mori,
Mariko Saito,
Kumiko K. Nobukawa,
Takaaki Tanaka,
Hiroyuki Uchida,
Kiyoshi Hayashida,
Hironori Matsumoto,
Hirofumi Noda,
Maho Hanaoka,
Tomokage Yoneyama,
Koki Okazaki,
Kazunori Asakura,
Shotaro Sakuma,
Kengo Hattori,
Ayami Ishikura,
Yuki Amano,
Hiromichi Okon,
Takeshi G. Tsuru,
Hiroshi Tomida,
Hikari Kashimura,
Hiroshi Nakajima
, et al. (16 additional authors not shown)
Abstract:
We present experimental studies on the charge transfer inefficiency (CTI) of charge-coupled device (CCD) developed for the soft X-ray imaging telescope, Xtend, aboard the XRISM satellite. The CCD is equipped with a charge injection (CI) capability, in which sacrificial charge is periodically injected to fill the charge traps. By evaluating the re-emission of the trapped charge observed behind the…
▽ More
We present experimental studies on the charge transfer inefficiency (CTI) of charge-coupled device (CCD) developed for the soft X-ray imaging telescope, Xtend, aboard the XRISM satellite. The CCD is equipped with a charge injection (CI) capability, in which sacrificial charge is periodically injected to fill the charge traps. By evaluating the re-emission of the trapped charge observed behind the CI rows, we find that there are at least three trap populations with different time constants. The traps with the shortest time constant, which is equivalent to a transfer time of approximately one pixel, are mainly responsible for the trailing charge of an X-ray event seen in the following pixel. A comparison of the trailing charge in two clocking modes reveals that the CTI depends not only on the transfer time but also on the area, namely the imaging or storage area. We construct a new CTI model with taking into account with both transfer-time and area dependence. This model reproduces the data obtained in both clocking modes consistently. We also examine apparent flux dependence of the CTI observed without the CI technique. The higher incident X-ray flux is, the lower the CTI value becomes. It is due to a sacrificial charge effect by another X-ray photon. This effect is found to be negligible when the CI technique is used.
△ Less
Submitted 15 September, 2020; v1 submitted 14 September, 2020;
originally announced September 2020.
Optical Blocking Performance of CCDs Developed for the X-ray Astronomy Satellite XRISM
Authors:
Hiroyuki Uchida,
Takaaki Tanaka,
Yuki Amano,
Hiromichi Okon,
Takeshi G. Tsuru,
Hirofumi Noda,
Kiyoshi Hayashida,
Hironori Matsumoto,
Maho Hanaoka,
Tomokage Yoneyama,
Koki Okazaki,
Kazunori Asakura,
Shotaro Sakuma,
Kengo Hattori,
Ayami Ishikura,
Hiroshi Nakajima,
Mariko Saito,
Kumiko K. Nobukawa,
Hiroshi Tomida,
Yoshiaki Kanemaru,
** Sato,
Toshiyuki Takaki,
Yuta Terada,
Koji Mori,
Hikari Kashimura
, et al. (21 additional authors not shown)
Abstract:
We have been develo** P-channel Charge-Coupled Devices (CCDs) for the upcoming X-ray Astronomy Satellite XRISM, planned to be launched in 2021. While the basic design of the CCD camera (Soft X-ray Imager: SXI) is almost the same as that of the lost Hitomi (ASTRO-H) observatory, we are planning to reduce the "light leakages" that is one of the largest problems recognized in Hitomi data. We adopte…
▽ More
We have been develo** P-channel Charge-Coupled Devices (CCDs) for the upcoming X-ray Astronomy Satellite XRISM, planned to be launched in 2021. While the basic design of the CCD camera (Soft X-ray Imager: SXI) is almost the same as that of the lost Hitomi (ASTRO-H) observatory, we are planning to reduce the "light leakages" that is one of the largest problems recognized in Hitomi data. We adopted a double-layer optical blocking layer on the XRISM CCDs and also added an extra aluminum layer on the backside of them. We develop a newly designed test sample CCD and irradiate it with optical light to evaluate the optical blocking performance. As a result, light leakages are effectively reduced compared with that of the Hitomi CCDs. We thus conclude that the issue is solved by the new design and that the XRISM CCDs satisfy the mission requirement for the SXI.
△ Less
Submitted 16 July, 2020; v1 submitted 15 July, 2020;
originally announced July 2020.