-
Deep-underground search for the decay of 180m-Ta with an ultra-low-background HPGe detector
Authors:
R. Cerroni,
S. Dell'Oro,
A. Formicola,
S. Ghislandi,
L. Ioannucci,
M. Laubenstein,
B. Lehnert,
S. S. Nagorny,
S. Nisi,
L. Pagnanini
Abstract:
$^{180m}$Ta is the longest-lived metastable state presently known. Its decay has not been observed yet. In this work, we report a new result on the decay of \mTa obtained with a $2015.12$-g tantalum sample measured for $527.7…
▽ More
$^{180m}$Ta is the longest-lived metastable state presently known. Its decay has not been observed yet. In this work, we report a new result on the decay of \mTa obtained with a $2015.12$-g tantalum sample measured for $527.7$ d with an ultra-low background HPGe detector in the STELLA laboratory of the Laboratori Nazionali del Gran Sasso (LNGS), in Italy. Before the measurement, the sample has been stored deep-underground for ten years, resulting in subdominant background contributions from cosmogenically activated $^{182}$Ta. We observe no signal in the regions of interest and set half-life limits on the process for the two channels EC and $β^-$: $T_{1/2,~\mathrm{EC}} > 1.6 \times 10^{18}$ yr and $T_{1/2,~β^-} > 1.1\times 10^{18}$ yr ($90$\% C.\,I.), respectively. We also set the limit on the $γ$ de-excitation / IC channel: $T_{1/2,~\mathrm{IC}} > 4.1 \times 10^{15}$ yr ($90$\% C.\,I.). These are, as of now, the most stringent bounds on the decay of $^{180m}$Ta worldwide. Finally, we test the hypothetical scenarios of de-excitation of $^{180m}$Ta by cosmological Dark Matter and constrain new parameter space for strongly-interacting dark-matter particle with mass up to $10^5$ GeV.
△ Less
Submitted 24 October, 2023; v1 submitted 26 May, 2023;
originally announced May 2023.
-
CUORE Opens the Door to Tonne-scale Cryogenics Experiments
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
F. Alessandria,
K. Alfonso,
E. Andreotti,
F. T. Avignone III,
O. Azzolini,
M. Balata,
I. Bandac,
T. I. Banks,
G. Bari,
M. Barucci,
J. W. Beeman,
F. Bellini,
G. Benato,
M. Beretta,
A. Bersani,
D. Biare,
M. Biassoni,
F. Bragazzi,
A. Branca,
C. Brofferio,
A. Bryant,
A. Buccheri
, et al. (184 additional authors not shown)
Abstract:
The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution - comparable to semiconductor detectors - and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require eve…
▽ More
The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution - comparable to semiconductor detectors - and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require ever greater exposures, which has driven them to ever larger cryogenic detectors, with the CUORE experiment being the first to reach a tonne-scale, mK-cooled, experimental mass. CUORE, designed to search for neutrinoless double beta decay, has been operational since 2017 at a temperature of about 10 mK. This result has been attained by the use of an unprecedentedly large cryogenic infrastructure called the CUORE cryostat: conceived, designed and commissioned for this purpose. In this article the main characteristics and features of the cryogenic facility developed for the CUORE experiment are highlighted. A brief introduction of the evolution of the field and of the past cryogenic facilities are given. The motivation behind the design and development of the CUORE cryogenic facility is detailed as are the steps taken toward realization, commissioning, and operation of the CUORE cryostat. The major challenges overcome by the collaboration and the solutions implemented throughout the building of the cryogenic facility will be discussed along with the potential improvements for future facilities. The success of CUORE has opened the door to a new generation of large-scale cryogenic facilities in numerous fields of science. Broader implications of the incredible feat achieved by the CUORE collaboration on the future cryogenic facilities in various fields ranging from neutrino and dark matter experiments to quantum computing will be examined.
△ Less
Submitted 2 December, 2021; v1 submitted 17 August, 2021;
originally announced August 2021.
-
Characterization of SABRE crystal NaI-33 with direct underground counting
Authors:
M. Antonello,
I. J. Arnquist,
E. Barberio,
T. Baroncelli,
J. Benziger,
L. J. Bignell,
I. Bolognino,
F. Calaprice,
S. Copello,
I. Dafinei,
D. D'Angelo,
G. D'Imperio,
M. D'Incecco,
G. Di Carlo,
M. Diemoz,
A. Di Giacinto,
A. Di Ludovico,
W. Dix,
A. R. Duffy,
E. Hoppe,
A. Ianni,
M. Iannone,
L. Ioannucci,
S. Krishnan,
G. J. Lane
, et al. (21 additional authors not shown)
Abstract:
Ultra-pure NaI(Tl) crystals are the key element for a model-independent verification of the long standing DAMA result and a powerful means to search for the annual modulation signature of dark matter interactions. The SABRE collaboration has been develo** cutting-edge techniques for the reduction of intrinsic backgrounds over several years. In this paper we report the first characterization of a…
▽ More
Ultra-pure NaI(Tl) crystals are the key element for a model-independent verification of the long standing DAMA result and a powerful means to search for the annual modulation signature of dark matter interactions. The SABRE collaboration has been develo** cutting-edge techniques for the reduction of intrinsic backgrounds over several years. In this paper we report the first characterization of a 3.4 kg crystal, named NaI-33, performed in an underground passive shielding setup at LNGS. NaI-33 has a record low $^{39}$K contamination of 4.3$\pm$0.2 ppb as determined by mass spectrometry. We measured a light yield of 11.1$\pm$0.2 photoelectrons/keV and an energy resolution of 13.2% (FWHM/E) at 59.5 keV. We evaluated the activities of $^{226}$Ra and $^{228}$Th inside the crystal to be $5.9\pm0.6 μ$Bq/kg and $1.6\pm0.3 μ$Bq/kg, respectively, which would indicate a contamination from $^{238}$U and $^{232}$Th at part-per-trillion level. We measured an activity of 0.51$\pm$0.02 mBq/kg due to $^{210}$Pb out of equilibrium and a $α$ quenching factor of 0.63$\pm$0.01 at 5304 keV. We illustrate the analyses techniques developed to reject electronic noise in the lower part of the energy spectrum. A cut-based strategy and a multivariate approach indicated a rate, attributed to the intrinsic radioactivity of the crystal, of $\sim$1 count/day/kg/keV in the [5-20] keV region.
△ Less
Submitted 12 April, 2021; v1 submitted 4 December, 2020;
originally announced December 2020.
-
The CUORE cryostat: an infrastructure for rare event searches at millikelvin temperatures
Authors:
C. Alduino,
F. Alessandria,
M. Balata,
D. Biare,
M. Biassoni,
C. Bucci,
A. Caminata,
L. Canonica,
L. Cappelli,
G. Ceruti,
A. Chiarini,
N. Chott,
M. Clemenza,
S. Copello,
A. Corsi,
O. Cremonesi,
A. D'Addabbo,
S. Dell'Oro,
L. Di Paolo,
M. L. Di Vacri,
A. Drobizhev,
M. Faverzani,
E. Ferri,
M. A. Franceschi,
R. Gaigher
, et al. (31 additional authors not shown)
Abstract:
The CUORE experiment is the world's largest bolometric experiment. The detector consists of an array of 988 TeO2 crystals, for a total mass of 742 kg. CUORE is presently taking data at the Laboratori Nazionali del Gran Sasso, Italy, searching for the neutrinoless double beta decay of 130Te. A large custom cryogen-free cryostat allows reaching and maintaining a base temperature of about 10 mK, requ…
▽ More
The CUORE experiment is the world's largest bolometric experiment. The detector consists of an array of 988 TeO2 crystals, for a total mass of 742 kg. CUORE is presently taking data at the Laboratori Nazionali del Gran Sasso, Italy, searching for the neutrinoless double beta decay of 130Te. A large custom cryogen-free cryostat allows reaching and maintaining a base temperature of about 10 mK, required for the optimal operation of the detector. This apparatus has been designed in order to achieve a low noise environment, with minimal contribution to the radioactive background for the experiment. In this paper, we present an overview of the CUORE cryostat, together with a description of all its sub-systems, focusing on the solutions identified to satisfy the stringent requirements. We briefly illustrate the various phases of the cryostat commissioning and highlight the relevant steps and milestones achieved each time. Finally, we describe the successful cooldown of CUORE.
△ Less
Submitted 12 July, 2019; v1 submitted 8 April, 2019;
originally announced April 2019.
-
Monte Carlo simulation of the SABRE PoP background
Authors:
M. Antonello,
E. Barberio,
T. Baroncelli,
J. Benziger,
L. J. Bignell,
I. Bolognino,
F. Calaprice,
S. Copello,
D. D'Angelo,
G. D'Imperio,
I. Dafinei,
G. Di Carlo,
M. Diemoz,
A. Di Ludovico,
A. R. Duffy,
F. Froborg,
G. K. Giovanetti,
E. Hoppe,
A. Ianni,
L. Ioannucci,
S. Krishnan,
G. J. Lane,
I. Mahmood,
A. Mariani,
P. McGee
, et al. (23 additional authors not shown)
Abstract:
SABRE (Sodium-iodide with Active Background REjection) is a direct dark matter search experiment based on an array of radio-pure NaI(Tl) crystals surrounded by a liquid scintillator veto. Twin SABRE experiments in the Northern and Southern Hemispheres will differentiate a dark matter signal from seasonal and local effects. The experiment is currently in a Proof-of-Principle (PoP) phase, whose goal…
▽ More
SABRE (Sodium-iodide with Active Background REjection) is a direct dark matter search experiment based on an array of radio-pure NaI(Tl) crystals surrounded by a liquid scintillator veto. Twin SABRE experiments in the Northern and Southern Hemispheres will differentiate a dark matter signal from seasonal and local effects. The experiment is currently in a Proof-of-Principle (PoP) phase, whose goal is to demonstrate that the background rate is low enough to carry out an independent search for a dark matter signal, with sufficient sensitivity to confirm or refute the DAMA result during the following full-scale experimental phase. The impact of background radiation from the detector materials and the experimental site needs to be carefully investigated, including both intrinsic and cosmogenically activated radioactivity. Based on the best knowledge of the most relevant sources of background, we have performed a detailed Monte Carlo study evaluating the expected background in the dark matter search spectral region. The simulation model described in this paper guides the design of the full-scale experiment and will be fundamental for the interpretation of the measured background and hence for the extraction of a possible dark matter signal.
△ Less
Submitted 14 November, 2018; v1 submitted 25 June, 2018;
originally announced June 2018.
-
The SABRE project and the SABRE PoP
Authors:
M. Antonello,
E. Barberio,
T. Baroncelli,
J. Benziger,
L. J. Bignell,
I. Bolognino,
F. Calaprice,
S. Copello,
D. D'Angelo,
G. D'Imperio,
I. Dafinei,
G. Di Carlo,
M. Diemoz,
A. Di Ludovico,
W. Dix,
A. R. Duffy,
F. Froborg,
G. K. Giovanetti,
E. Hoppe,
A. Ianni,
L. Ioannucci,
S. Krishnan,
G. J. Lane,
I. Mahmood,
A. Mariani
, et al. (24 additional authors not shown)
Abstract:
SABRE aims to directly measure the annual modulation of the dark matter interaction rate with NaI(Tl) crystals. A modulation compatible with the standard hypothesis in which our Galaxy is embedded in a dark matter halo has been measured by the DAMA experiment in the same target material. Other direct detection experiments, using different target materials, seem to exclude the interpretation of suc…
▽ More
SABRE aims to directly measure the annual modulation of the dark matter interaction rate with NaI(Tl) crystals. A modulation compatible with the standard hypothesis in which our Galaxy is embedded in a dark matter halo has been measured by the DAMA experiment in the same target material. Other direct detection experiments, using different target materials, seem to exclude the interpretation of such modulation in the simplest scenario of WIMP-nucleon elastic scattering. The SABRE experiment aims to carry out an independent search with sufficient sensitivity to confirm or refute the DAMA claim. The SABRE concept and goal is to obtain a background rate of the order of 0.1 cpd/kg/keVee in the energy region of interest. This challenging goal is achievable by operating high-purity crystals inside a liquid scintillator veto for active background rejection. In addition, twin detectors will be located in the northern and southern hemispheres to identify possible contributions to the modulation from seasonal or site-related effects. The SABRE project includes an initial Proof-of-Principle phase at LNGS (Italy), to assess the radio-purity of the crystals and the efficiency of the liquid scintillator veto. This paper describes the general concept of SABRE and the expected sensitivity to WIMP annual modulation.
△ Less
Submitted 19 November, 2018; v1 submitted 25 June, 2018;
originally announced June 2018.
-
Upgrade for Phase II of the GERDA Experiment
Authors:
M. Agostini,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
L. Baudis,
C. Bauer,
E. Bellotti,
S. Belogurov,
S. T. Belyaev,
G. Benato,
A. Bettini,
L. Bezrukov,
T. Bode,
D. Borowicz,
V. Brudanin,
R. Brugnera,
A. Caldwell,
C. Cattadori,
A. Chernogorov,
V. D'Andrea,
E. V. Demidova,
N. Di Marco,
A. Domula,
E. Doroshkevich,
V. Egorov
, et al. (89 additional authors not shown)
Abstract:
The GERDA collaboration is performing a sensitive search for neutrinoless double beta decay of $^{76}$Ge at the INFN Laboratori Nazionali del Gran Sasso, Italy. The upgrade of the GERDA experiment from Phase I to Phase II has been concluded in December 2015. The first Phase II data release shows that the goal to suppress the background by one order of magnitude compared to Phase I has been achieve…
▽ More
The GERDA collaboration is performing a sensitive search for neutrinoless double beta decay of $^{76}$Ge at the INFN Laboratori Nazionali del Gran Sasso, Italy. The upgrade of the GERDA experiment from Phase I to Phase II has been concluded in December 2015. The first Phase II data release shows that the goal to suppress the background by one order of magnitude compared to Phase I has been achieved. GERDA is thus the first experiment that will remain background-free up to its design exposure (100 kg yr). It will reach thereby a half-life sensitivity of more than 10$^{26}$ yr within 3 years of data collection. This paper describes in detail the modifications and improvements of the experimental setup for Phase II and discusses the performance of individual detector components.
△ Less
Submitted 4 November, 2017;
originally announced November 2017.
-
CUORE-0 detector: design, construction and operation
Authors:
CUORE Collaboration,
C. Alduino,
K. Alfonso,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. W. Beeman,
F. Bellini,
A. Bersani,
D. Biare,
M. Biassoni,
F. Bragazzi,
C. Brofferio,
A. Buccheri,
C. Bucci,
C. Bulfon,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
M. Capodiferro,
L. Cappelli
, et al. (129 additional authors not shown)
Abstract:
The CUORE experiment will search for neutrinoless double-beta decay of $^{130}$Te with an array of 988 TeO$_2$ bolometers arranged in 19 towers. CUORE-0, the first tower assembled according to the CUORE procedures, was built and commissioned at Laboratori Nazionali del Gran Sasso, and took data from March 2013 to March 2015. In this paper we describe the design, construction and operation of the C…
▽ More
The CUORE experiment will search for neutrinoless double-beta decay of $^{130}$Te with an array of 988 TeO$_2$ bolometers arranged in 19 towers. CUORE-0, the first tower assembled according to the CUORE procedures, was built and commissioned at Laboratori Nazionali del Gran Sasso, and took data from March 2013 to March 2015. In this paper we describe the design, construction and operation of the CUORE-0 experiment, with an emphasis on the improvements made over a predecessor experiment, Cuoricino. In particular, we demonstrate with CUORE-0 data that the design goals of CUORE are within reach.
△ Less
Submitted 18 July, 2016; v1 submitted 19 April, 2016;
originally announced April 2016.
-
Flux Modulations seen by the Muon Veto of the GERDA Experiment
Authors:
M. Agostini,
M. Allardt,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
N. Barros,
L. Baudis,
C. Bauer,
N. Becerici-Schmidt,
E. Bellotti,
S. Belogurov,
S. T. Belyaev,
G. Benato,
A. Bettini,
L. Bezrukov,
T. Bode,
D. Borowicz,
V. Brudanin,
R. Brugnera,
A. Caldwell,
C. Cattadori,
A. Chernogorov,
V. D'Andrea,
E. V. Demidova,
A. di Vacri
, et al. (90 additional authors not shown)
Abstract:
The GERDA experiment at LNGS of INFN is equipped with an active muon veto. The main part of the system is a water Cherenkov veto with 66~PMTs in the water tank surrounding the GERDA cryostat. The muon flux recorded by this veto shows a seasonal modulation. Two effects have been identified which are caused by secondary muons from the CNGS neutrino beam (2.2 %) and a temperature modulation of the at…
▽ More
The GERDA experiment at LNGS of INFN is equipped with an active muon veto. The main part of the system is a water Cherenkov veto with 66~PMTs in the water tank surrounding the GERDA cryostat. The muon flux recorded by this veto shows a seasonal modulation. Two effects have been identified which are caused by secondary muons from the CNGS neutrino beam (2.2 %) and a temperature modulation of the atmosphere (1.4 %). A mean cosmic muon rate of $I^0_μ = (3.477 \pm 0.002_{\textrm{stat}} \pm 0.067_{\textrm{sys}}) \times 10^{-4}$/(s$\cdot$m$^2$) was found in good agreement with other experiments at LNGS at a depth of 3500~meter water equivalent.
△ Less
Submitted 22 January, 2016;
originally announced January 2016.
-
Production, characterization and operation of $^{76}$Ge enriched BEGe detectors in GERDA
Authors:
M. Agostini,
M. Allardt,
E. Andreotti,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
N. Barros,
L. Baudis,
C. Bauer,
N. Becerici-Schmidt,
E. Bellotti,
S. Belogurov,
S. T. Belyaev,
G. Benato,
A. Bettini,
L. Bezrukov,
T. Bode,
D. Borowicz,
V. Brudanin,
R. Brugnera,
D. Budjas,
A. Caldwel,
C. Cattadori,
A. Chernogorov,
V. D'Andrea
, et al. (87 additional authors not shown)
Abstract:
The GERmanium Detector Array (GERDA) at the Gran Sasso Underground Laboratory (LNGS) searches for the neutrinoless double beta decay (0νββ) of $^{76}$Ge. Germanium detectors made of material with an enriched $^{76}$Ge fraction act simultaneously as sources and detectors for this decay.
During Phase I of the experiment mainly refurbished semi-coaxial Ge detectors from former experiments were used…
▽ More
The GERmanium Detector Array (GERDA) at the Gran Sasso Underground Laboratory (LNGS) searches for the neutrinoless double beta decay (0νββ) of $^{76}$Ge. Germanium detectors made of material with an enriched $^{76}$Ge fraction act simultaneously as sources and detectors for this decay.
During Phase I of the experiment mainly refurbished semi-coaxial Ge detectors from former experiments were used. For the upcoming Phase II, 30 new $^{76}$Ge enriched detectors of broad energy germanium (BEGe)-type were produced. A subgroup of these detectors has already been deployed in GERDA during Phase I.
The present paper reviews the complete production chain of these BEGe detectors including isotopic enrichment, purification, crystal growth and diode production. The efforts in optimizing the mass yield and in minimizing the exposure of the $^{76}$Ge enriched germanium to cosmic radiation during processing are described. Furthermore, characterization measurements in vacuum cryostats of the first subgroup of seven BEGe detectors and their long-term behavior in liquid argon are discussed. The detector performance fulfills the requirements needed for the physics goals of GERDA Phase~II.
△ Less
Submitted 3 October, 2014;
originally announced October 2014.
-
Results on neutrinoless double beta decay of 76Ge from GERDA Phase I
Authors:
M. Agostini,
M. Allardt,
E. Andreotti,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
M. Barnabé Heider,
N. Barros,
L. Baudis,
C. Bauer,
N. Becerici-Schmidt,
E. Bellotti,
S. Belogurov,
S. T. Belyaev,
G. Benato,
A. Bettini,
L. Bezrukov,
T. Bode,
V. Brudanin,
R. Brugnera,
D. Budjáš,
A. Caldwell,
C. Cattadori,
A. Chernogorov,
F. Cossavella
, et al. (90 additional authors not shown)
Abstract:
Neutrinoless double beta decay is a process that violates lepton number conservation. It is predicted to occur in extensions of the Standard Model of particle physics. This Letter reports the results from Phase I of the GERmanium Detector Array (GERDA) experiment at the Gran Sasso Laboratory (Italy) searching for neutrinoless double beta decay of the isotope 76Ge. Data considered in the present an…
▽ More
Neutrinoless double beta decay is a process that violates lepton number conservation. It is predicted to occur in extensions of the Standard Model of particle physics. This Letter reports the results from Phase I of the GERmanium Detector Array (GERDA) experiment at the Gran Sasso Laboratory (Italy) searching for neutrinoless double beta decay of the isotope 76Ge. Data considered in the present analysis have been collected between November 2011 and May 2013 with a total exposure of 21.6 kgyr. A blind analysis is performed. The background index is about 1.10^{-2} cts/(keV kg yr) after pulse shape discrimination. No signal is observed and a lower limit is derived for the half-life of neutrinoless double beta decay of 76Ge, T_1/2 > 2.1 10^{25} yr (90% C.L.). The combination with the results from the previous experiments with 76Ge yields T_1/2 > 3.0 10^{25} yr (90% C.L.).
△ Less
Submitted 17 July, 2013;
originally announced July 2013.
-
Pulse shape discrimination for GERDA Phase I data
Authors:
M. Agostini,
M. Allardt,
E. Andreotti,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
M. Barnabe Heider,
N. Barros,
L. Baudis,
C. Bauer,
N. Becerici-Schmidt,
E. Bellotti,
S. Belogurov,
S. T. Belyaev,
G. Benato,
A. Bettini,
L. Bezrukov,
T. Bode,
V. Brudanin,
R. Brugnera,
D. Budjáš,
A. Caldwell,
C. Cattadori,
A. Chernogorov,
F. Cossavella
, et al. (89 additional authors not shown)
Abstract:
The GERDA experiment located at the LNGS searches for neutrinoless double beta (0νββ) decay of ^{76}Ge using germanium diodes as source and detector. In Phase I of the experiment eight semi-coaxial and five BEGe type detectors have been deployed. The latter type is used in this field of research for the first time. All detectors are made from material with enriched ^{76}Ge fraction. The experiment…
▽ More
The GERDA experiment located at the LNGS searches for neutrinoless double beta (0νββ) decay of ^{76}Ge using germanium diodes as source and detector. In Phase I of the experiment eight semi-coaxial and five BEGe type detectors have been deployed. The latter type is used in this field of research for the first time. All detectors are made from material with enriched ^{76}Ge fraction. The experimental sensitivity can be improved by analyzing the pulse shape of the detector signals with the aim to reject background events. This paper documents the algorithms developed before the data of Phase I were unblinded. The double escape peak (DEP) and Compton edge events of 2.615 MeV γ rays from ^{208}Tl decays as well as 2νββ decays of ^{76}Ge are used as proxies for 0νββ decay. For BEGe detectors the chosen selection is based on a single pulse shape parameter. It accepts 0.92$\pm$0.02 of signal-like events while about 80% of the background events at Q_{ββ}=2039 keV are rejected.
For semi-coaxial detectors three analyses are developed. The one based on an artificial neural network is used for the search of 0νββ decay. It retains 90% of DEP events and rejects about half of the events around Q_{ββ}. The 2νββ events have an efficiency of 0.85\pm0.02 and the one for 0νββ decays is estimated to be 0.90^{+0.05}_{-0.09}. A second analysis uses a likelihood approach trained on Compton edge events. The third approach uses two pulse shape parameters. The latter two methods confirm the classification of the neural network since about 90% of the data events rejected by the neural network are also removed by both of them. In general, the selection efficiency extracted from DEP events agrees well with those determined from Compton edge events or from 2νββ decays.
△ Less
Submitted 9 July, 2013;
originally announced July 2013.
-
The background in the neutrinoless double beta decay experiment GERDA
Authors:
The GERDA collaboration,
M. Agostini,
M. Allardt,
E. Andreotti,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
M. Barnabe Heider,
N. Barros,
L. Baudis,
C. Bauer,
N. Becerici-Schmidt,
E. Bellotti,
S. Belogurov,
S. T. Belyaev,
G. Benato,
A. Bettini,
L. Bezrukov,
T. Bode,
V. Brudanin,
R. Brugnera,
D. Budjas,
A. Caldwell,
C. Cattadori,
A. Chernogorov
, et al. (89 additional authors not shown)
Abstract:
The GERmanium Detector Array (GERDA) experiment at the Gran Sasso underground laboratory (LNGS) of INFN is searching for neutrinoless double beta decay of 76Ge. The signature of the signal is a monoenergetic peak at 2039 keV, the Q-value of the decay, Q_bb. To avoid bias in the signal search, the present analysis does not consider all those events, that fall in a 40 keV wide region centered around…
▽ More
The GERmanium Detector Array (GERDA) experiment at the Gran Sasso underground laboratory (LNGS) of INFN is searching for neutrinoless double beta decay of 76Ge. The signature of the signal is a monoenergetic peak at 2039 keV, the Q-value of the decay, Q_bb. To avoid bias in the signal search, the present analysis does not consider all those events, that fall in a 40 keV wide region centered around Q_bb. The main parameters needed for the neutrinoless double beta decay analysis are described. A background model was developed to describe the observed energy spectrum. The model contains several contributions, that are expected on the basis of material screening or that are established by the observation of characteristic structures in the energy spectrum. The model predicts a flat energy spectrum for the blinding window around Q_bb with a background index ranging from 17.6 to 23.8*10^{-3} counts/(keV kg yr). A part of the data not considered before has been used to test if the predictions of the background model are consistent. The observed number of events in this energy region is consistent with the background model. The background at Q-bb is dominated by close sources, mainly due to 42K, 214Bi, 228Th, 60Co and alpha emitting isotopes from the 226Ra decay chain. The individual fractions depend on the assumed locations of the contaminants. It is shown, that after removal of the known gamma peaks, the energy spectrum can be fitted in an energy range of 200 kev around Q_bb with a constant background. This gives a background index consistent with the full model and uncertainties of the same size.
△ Less
Submitted 10 April, 2014; v1 submitted 21 June, 2013;
originally announced June 2013.
-
The GERDA experiment for the search of 0νββ decay in ^{76}Ge
Authors:
GERDA Collaboration,
K. -H. Ackermann,
M. Agostini,
M. Allardt,
M. Altmann,
E. Andreotti,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
M. Barnabe Heider,
N. Barros,
L. Baudis,
C. Bauer,
N. Becerici-Schmidt,
E. Bellotti,
S. Belogurov,
S. T. Belyaev,
G. Benato,
A. Bettini,
L. Bezrukov,
T. Bode,
V. Brudanin,
R. Brugnera,
D. Budjas,
A. Caldwell
, et al. (114 additional authors not shown)
Abstract:
The GERDA collaboration is performing a search for neutrinoless double beta decay of ^{76}Ge with the eponymous detector. The experiment has been installed and commissioned at the Laboratori Nazionali del Gran Sasso and has started operation in November 2011. The design, construction and first operational results are described, along with detailed information from the R&D phase.
The GERDA collaboration is performing a search for neutrinoless double beta decay of ^{76}Ge with the eponymous detector. The experiment has been installed and commissioned at the Laboratori Nazionali del Gran Sasso and has started operation in November 2011. The design, construction and first operational results are described, along with detailed information from the R&D phase.
△ Less
Submitted 17 December, 2012;
originally announced December 2012.
-
Measurement of the half-life of the two-neutrino double beta decay of Ge-76 with the Gerda experiment
Authors:
GERDA Collaboration,
M. Agostini,
M. Allardt,
E. Andreotti,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
M. Barnabe Heider,
N. Barros,
L. Baudis,
C. Bauer,
N. Becerici-Schmidt,
E. Bellotti,
S. Belogurov,
S. T. Belyaev,
G. Benato,
A. Bettini,
L. Bezrukov,
T. Bode,
V. Brudanin,
R. Brugnera,
D. Budjas,
A. Caldwell,
C. Cattadori,
A. Chernogorov
, et al. (88 additional authors not shown)
Abstract:
The primary goal of the GERmanium Detector Array (Gerda) experiment at the Laboratori Nazionali del Gran Sasso of INFN is the search for the neutrinoless double beta decay of Ge-76. High-purity germanium detectors made from material enriched in Ge-76 are operated directly immersed in liquid argon, allowing for a substantial reduction of the background with respect to predecessor experiments. The f…
▽ More
The primary goal of the GERmanium Detector Array (Gerda) experiment at the Laboratori Nazionali del Gran Sasso of INFN is the search for the neutrinoless double beta decay of Ge-76. High-purity germanium detectors made from material enriched in Ge-76 are operated directly immersed in liquid argon, allowing for a substantial reduction of the background with respect to predecessor experiments. The first 5.04 kg yr of data collected in Phase I of the experiment have been analyzed to measure the half-life of the neutrino-accompanied double beta decay of Ge-76. The observed spectrum in the energy range between 600 and 1800 keV is dominated by the double beta decay of Ge-76. The half-life extracted from Gerda data is T(1/2) = (1.84 +0.14 -0.10) 10^{21} yr.
△ Less
Submitted 13 December, 2012;
originally announced December 2012.
-
Performances and stability of a 2.4 ton Gd organic liquid scintillator target for antineutrino detection
Authors:
I. R. Barabanov,
L. B. Bezrukov,
C. Cattadori,
N. A. Danilov,
A. Di Vacri,
Yu. S. Krilov,
L. Ioannucci,
E. A. Yanovich,
M. Aglietta,
A. Bonardi,
G. Bruno,
W. Fulgione,
E. Kemp,
A. S. Malguin,
A. Porta,
M. Selvi
Abstract:
In this work we report the performances and the chemical and physical properties of a (2 x 1.2) ton organic liquid scintillator target doped with Gd up to ~0.1%, and the results of a 2 year long stability survey. In particular we have monitored the amount of both Gd and primary fluor actually in solution, the optical and fluorescent properties of the Gd-doped liquid scintillator (GdLS) and its p…
▽ More
In this work we report the performances and the chemical and physical properties of a (2 x 1.2) ton organic liquid scintillator target doped with Gd up to ~0.1%, and the results of a 2 year long stability survey. In particular we have monitored the amount of both Gd and primary fluor actually in solution, the optical and fluorescent properties of the Gd-doped liquid scintillator (GdLS) and its performances as a neutron detector, namely neutron capture efficiency and average capture time. The experimental survey is ongoing, the target being continuously monitored. After two years from the do** time the performances of the Gd-doped liquid scintillator do not show any hint of degradation and instability; this conclusion comes both from the laboratory measurements and from the "in-tank" measurements. This is the largest stable Gd-doped organic liquid scintillator target ever produced and continuously operated for a long period.
△ Less
Submitted 11 March, 2008;
originally announced March 2008.