-
Design and Performance of the Soft Gamma-ray Detector for the NeXT mission
Authors:
H. Tajima,
T. Kamae,
G. Madejski,
T. Mitani,
K. Nakazawa,
T. Tanaka,
T. Takahashi,
S. Watanabe,
Y. Fukazawa,
T. Ikagawa,
J. Kataoka,
M. Kokubun,
K. Makishima,
Y. Terada,
M. Nomachi,
M. Tashiro
Abstract:
The Soft Gamma-ray Detector (SGD) on board the NeXT (Japanese future high energy astrophysics mission) is a Compton telescope with narrow field of view (FOV), which utilizes Compton kinematics to enhance its background rejection capabilities. It is realized as a hybrid semiconductor gamma-ray detector which consists of silicon and CdTe (cadmium telluride) detectors. It can detect photons in a wi…
▽ More
The Soft Gamma-ray Detector (SGD) on board the NeXT (Japanese future high energy astrophysics mission) is a Compton telescope with narrow field of view (FOV), which utilizes Compton kinematics to enhance its background rejection capabilities. It is realized as a hybrid semiconductor gamma-ray detector which consists of silicon and CdTe (cadmium telluride) detectors. It can detect photons in a wide energy band (0.05-1 MeV) at a background level of 5 x 10^-7 counts/cm^2/s; the silicon layers are required to improve the performance at a lower energy band (<0.3 MeV). Excellent energy resolution is the key feature of the SGD, allowing it to achieve both high angular resolution and good background rejection capability. An additional capability of the SGD, its ability to measure gamma-ray polarization, opens up a new window to study properties of astronomical objects. We will present the development of key technologies to realize the SGD: high quality CdTe, low noise front-end ASIC and bump bonding technology. Energy resolutions of 1.7 keV (FWHM) for CdTe pixel detectors and 1.1 keV for Si strip detectors have been measured. We also present the validation of Monte Carlo simulation used to evaluate the performance of the SGD.
△ Less
Submitted 17 April, 2006;
originally announced April 2006.
-
An Active Gain-control System for Avalanche Photo-Diodes under Moderate Temperature Variations
Authors:
J. Kataoka,
R. Sato,
T. Ikagawa,
J. Kotoku,
Y. Kuramoto,
Y. Tsubuku,
T. Saito,
Y. Yatsu,
N. Kawai,
Y. Ishikawa,
N. Kawabata
Abstract:
Avalanche photodiodes (APDs) are promising light sensor for various fields of experimental physics. It has been argued, however, that variation of APD gain with temperature could be a serious problem preventing APDs from replacing traditional photomultiplier tubes (PMTs) in some applications. Here we develop an active gain-control system to keep the APD gain stable under moderate temperature var…
▽ More
Avalanche photodiodes (APDs) are promising light sensor for various fields of experimental physics. It has been argued, however, that variation of APD gain with temperature could be a serious problem preventing APDs from replacing traditional photomultiplier tubes (PMTs) in some applications. Here we develop an active gain-control system to keep the APD gain stable under moderate temperature variations. As a performance demonstration of the proposed system, we have tested the response of a scintillation photon detector consisting of a 5x5 mm^2 reverse-type APD optically coupled with a CsI(Tl) crystal. We show that the APD gain was successfully controlled under a temperature variation of DT = 20deg, within a time-cycle of 6000 sec. The best FWHM energy resolution of 6.1+-0.2 % was obtained for 662 keV gamma-rays, and the energy threshold was as low as 6.5 keV, by integrating data from +20deg - 0deg cycles. The corresponding values for -20deg - 0deg cycles were 6.9+-0.2 % and 5.2 keV, respectively. These results are comparable, or only slightly worse than that obtained at a fixed temperature. Our results suggest new potential uses for APDs in various space researches and nuclear physics. As examples, we briefly introduce the NeXT and Cute-1.7 satellite missions that will carry the APDs as scientific instruments for the first time.
△ Less
Submitted 17 February, 2006;
originally announced February 2006.
-
Recent progress of avalanche photodiodes in high-resolution X-rays and Gamma-rays detection
Authors:
J. Kataoka,
T. Saito,
Y. Kuramoto,
T. Ikagawa,
Y. Yatsu,
J. Kotoku,
M. Arimoto,
N. Kawai,
Y. Ishikawa,
N. Kawabata
Abstract:
We have studied the performance of large area avalanche photodiodes (APDs) recently developed by Hamamatsu Photonics K.K, in high-resolution X-rays and Gamma-rays detections. We show that reach-through APD can be an excellent soft X-ray detector operating at room temperature or moderately cooled environment. We obtain the best energy resolution ever achieved with APDs, 6.4 % for 5.9 keV X-rays,…
▽ More
We have studied the performance of large area avalanche photodiodes (APDs) recently developed by Hamamatsu Photonics K.K, in high-resolution X-rays and Gamma-rays detections. We show that reach-through APD can be an excellent soft X-ray detector operating at room temperature or moderately cooled environment. We obtain the best energy resolution ever achieved with APDs, 6.4 % for 5.9 keV X-rays, and obtain the energy threshold as low as 0.5 keV measured at -20deg. Thanks to its fast timing response, signal carriers in the APD device are collected within a short time interval of 1.9 nsec (FWHM). This type of APDs can therefore be used as a low-energy, high-counting particle monitor onboard the forthcoming Pico-satellite Cute1.7. As a scintillation photon detector, reverse-type APDs have a good advantage of reducing the dark noise significantly. The best FWHM energy resolutions of 9.4+-0.3 % and 4.9+-0.2 % were obtained for 59.5 keV and 662 keV Gamma-rays, respectively, as measured with a CsI(Tl) crystal. Combination of APDs with various other scintillators (BGO, GSO, and YAP) also showed better results than that obtained with a photomultiplier tube (PMT). These results suggest that APD could be a promising device for replacing traditional PMT usage in some applications. In particular 2-dim APD array, which we present in this paper, will be a promising device for a wide-band X-ray and Gamma-ray imaging detector in future space research and nuclear medicine.
△ Less
Submitted 17 February, 2006;
originally announced February 2006.