-
Non-Adiabatic Effects on Electron Beam Quality for Frequency-Tunable Gyrotrons
Authors:
Cheng-Hung Tsai,
Tsun-Hsu Chang,
Toshitaka Idehara,
Yuusuke Yamaguchi
Abstract:
We propose an unconventional electron gun structure in which the emitter is located on a concave cathode surface with a non-uniform electric field. Such a design violates the intuition that an emitter should place close to a uniform electric field to reduce the velocity spread. The commonly employed design guide based on the adiabatic condition predicts a huge velocity spread of 24%, but the simul…
▽ More
We propose an unconventional electron gun structure in which the emitter is located on a concave cathode surface with a non-uniform electric field. Such a design violates the intuition that an emitter should place close to a uniform electric field to reduce the velocity spread. The commonly employed design guide based on the adiabatic condition predicts a huge velocity spread of 24%, but the simulation using EGUN code and verified with CST particle studio shows a very low spread of 2.8%. Examining the magnetic moment and the kinetic energy of the beam reveals that the electrons experience a relatively long acceleration process due to the much weak electric field. That's why the non-adiabatic effect matters. In addition to the cyclotron compression and the E$\times$B drift, the "resonant" polarization drift plays a crucial role in reducing the overall velocity spread.Simulations show a decent beam quality with the pitch factor of 1.5 and the transverse velocity spread of 2.8% over a wide range of the magnetic field (7.4-8.0 T) and the beam voltage (12-22 kV) with a high structural tolerance. The promising results with the wide working range enable the development of continuous frequency-tunable gyrotrons.
△ Less
Submitted 21 May, 2019; v1 submitted 29 April, 2019;
originally announced April 2019.
-
First results from a hidden photon dark matter search in the meV sector using a plane-parabolic mirror system
Authors:
Stefan Knirck,
Takayuki Yamazaki,
Yoshiki Okesaku,
Shoji Asai,
Toshitaka Idehara,
Toshiaki Inada
Abstract:
We report on the first results from a new dish antenna search for hidden photon dark matter (HPDM) in the meV mass region. A double mirror system composed of a plane and a parabolic mirror is designed to convert HPDMs into photons focused on a receiver. In this phase 1 experiment we obtain an upper limit on the photon-HP kinetic mixing $χ\lesssim 10^{-8}$ for the mass range of…
▽ More
We report on the first results from a new dish antenna search for hidden photon dark matter (HPDM) in the meV mass region. A double mirror system composed of a plane and a parabolic mirror is designed to convert HPDMs into photons focused on a receiver. In this phase 1 experiment we obtain an upper limit on the photon-HP kinetic mixing $χ\lesssim 10^{-8}$ for the mass range of $0.67-0.92\,{\rm meV}$ using conventional mm-wave technology with a room-temperature receiver and a small-sized mirror system.
△ Less
Submitted 28 November, 2018; v1 submitted 13 June, 2018;
originally announced June 2018.
-
Gyrotrons for High-Power Terahertz Science and Technology at FIR UF
Authors:
Toshitaka Idehara,
Svilen Petrov Sabchevski
Abstract:
In this paper, we present the recent progress in the development of a series of gyrotrons at FIR UF that have opened the road to many novel applications in the high-power Terahertz science and technology. The current status of the research in this actively develo** field is illustrated by the most representative examples in which the developed gyrotrons are used as powerful and frequency tunable…
▽ More
In this paper, we present the recent progress in the development of a series of gyrotrons at FIR UF that have opened the road to many novel applications in the high-power Terahertz science and technology. The current status of the research in this actively develo** field is illustrated by the most representative examples in which the developed gyrotrons are used as powerful and frequency tunable sources of coherent radiation operating in a CW regime. Among them are high-precision spectroscopic techniques (most notably DNP-NMR, ESR, XDMR, and studies of the hyperfine splitting of the energy levels of positronium), treatment and characterization of advanced materials, new medical technologies.
△ Less
Submitted 18 July, 2016;
originally announced July 2016.
-
Finite-Bandwidth Resonances of High-Order Axial Modes (HOAM) in a Gyrotron Cavity
Authors:
Svilen Sabchevski,
Toshitaka Idehara
Abstract:
Finite-bandwidth resonances of high-order axial modes (HOAM) in an open gyrotron cavity are studied numerically using the GYROSIM problem-oriented software package for modelling, simulation and computer-aided design (CAD) of gyrotron tubes.
Finite-bandwidth resonances of high-order axial modes (HOAM) in an open gyrotron cavity are studied numerically using the GYROSIM problem-oriented software package for modelling, simulation and computer-aided design (CAD) of gyrotron tubes.
△ Less
Submitted 7 November, 2014; v1 submitted 17 October, 2014;
originally announced October 2014.
-
First Millimeter-wave Spectroscopy of the Ground-state Positronium
Authors:
A. Miyazaki,
T. Yamazaki,
T. Suehara,
T. Namba,
S. Asai,
T. Kobayashi,
H. Saito,
Y. Tatematsu,
I. Ogawa,
T. Idehara
Abstract:
We report on the first measurement of the Breit-Wigner resonance of the transition from {\it ortho-}positronium to {\it para-}positronium. We have developed an optical system to accumulate a power of over 20 kW using a frequency-tunable gyrotron and a Fabry-Pérot cavity. This system opens a new era of millimeter-wave spectroscopy, and enables us to directly determine both the hyperfine interval an…
▽ More
We report on the first measurement of the Breit-Wigner resonance of the transition from {\it ortho-}positronium to {\it para-}positronium. We have developed an optical system to accumulate a power of over 20 kW using a frequency-tunable gyrotron and a Fabry-Pérot cavity. This system opens a new era of millimeter-wave spectroscopy, and enables us to directly determine both the hyperfine interval and the decay width of {\it p-}Ps.
△ Less
Submitted 17 December, 2014; v1 submitted 2 March, 2014;
originally announced March 2014.
-
A Dual-Beam Irradiation Facility for a Novel Hybrid Cancer Therapy
Authors:
Svilen Sabchevski,
Toshitaka Idehara,
Shintaro Ishiyama,
Norio Miyoshi,
Toshiaki Tatsukawa
Abstract:
In this paper we present the main ideas and discuss both the feasibility and the conceptual design of a novel hybrid technique and equipment for an experimental cancer therapy based on the simultaneous and/or sequential application of two beams, namely a beam of neutrons and a CW (continuous wave) or intermittent sub-terahertz wave beam produced by a gyrotron for treatment of cancerous tumors. The…
▽ More
In this paper we present the main ideas and discuss both the feasibility and the conceptual design of a novel hybrid technique and equipment for an experimental cancer therapy based on the simultaneous and/or sequential application of two beams, namely a beam of neutrons and a CW (continuous wave) or intermittent sub-terahertz wave beam produced by a gyrotron for treatment of cancerous tumors. The main simulation tools for the development of the computer aided design (CAD) of the prospective experimental facility for clinical trials and study of such new medical technology are briefly reviewed. Some tasks for a further continuation of this feasibility analysis are formulated as well.
△ Less
Submitted 21 June, 2012;
originally announced June 2012.
-
Direct Observation of the Hyperfine Transition of the Ground State Positronium
Authors:
T. Yamazaki,
A. Miyazaki,
T. Suehara,
T. Namba,
S. Asai,
T. Kobayashi,
H. Saito,
I. Ogawa,
T. Idehara,
S. Sabchevski
Abstract:
We report the first direct measurement of the hyperfine transition of the ground state positronium. The hyperfine structure between ortho-positronium and para-positronium is about 203 GHz. We develop a new optical system to accumulate about 10 kW power using a gyrotron, a mode converter, and a Fabry-Pérot cavity. The hyperfine transition has been observed with a significance of 5.4 standard deviat…
▽ More
We report the first direct measurement of the hyperfine transition of the ground state positronium. The hyperfine structure between ortho-positronium and para-positronium is about 203 GHz. We develop a new optical system to accumulate about 10 kW power using a gyrotron, a mode converter, and a Fabry-Pérot cavity. The hyperfine transition has been observed with a significance of 5.4 standard deviations. The transition probability is measured to be $A = 3.1^{+1.6}_{-1.2} \times 10^{-8}$ s$^{-1}$ for the first time, which is in good agreement with the theoretical value of $3.37 \times 10^{-8}$ s$^{-1}$.
△ Less
Submitted 16 May, 2012; v1 submitted 5 April, 2012;
originally announced April 2012.
-
First direct measurement of positronium hyperfine splitting with sub-THz light
Authors:
T. Yamazaki,
A. Miyazaki,
T. Suehara,
T. Namba,
S. Asai,
T. Kobayashi,
H. Saito,
Y. Urushizaki,
I. Ogawa,
T. Idehara,
S. Sabchevski
Abstract:
Positronium is an ideal system for the research of the bound state QED. The hyperfine splitting of positronium (Ps-HFS, about 203 GHz) is an important observable but all previous measurements of Ps-HFS had been measured indirectly using Zeeman splitting. There might be the unknown systematic errors on the uniformity of magnetic field. We are trying to measure Ps-HFS directly using sub-THz radiatio…
▽ More
Positronium is an ideal system for the research of the bound state QED. The hyperfine splitting of positronium (Ps-HFS, about 203 GHz) is an important observable but all previous measurements of Ps-HFS had been measured indirectly using Zeeman splitting. There might be the unknown systematic errors on the uniformity of magnetic field. We are trying to measure Ps-HFS directly using sub-THz radiation. We developed an optical system to accumulate high power (about 10 kW) radiation in a Fabry-Pérot resonant cavity and observed the positronium hyperfine transition for the first time.
△ Less
Submitted 22 May, 2011;
originally announced May 2011.
-
Development of the analog ASIC for multi-channel readout X-ray CCD camera
Authors:
Hiroshi Nakajima,
Daisuke Matsuura,
Toshihiro Idehara,
Naohisa Anabuki,
Hiroshi Tsunemi,
John P. Doty,
Hirokazu Ikeda,
Haruyoshi Katayama,
Hisashi Kitamura,
Yukio Uchihori
Abstract:
We report on the performance of an analog application-specific integrated circuit (ASIC) developed aiming for the front-end electronics of the X-ray CCDcamera system onboard the next X-ray astronomical satellite, ASTRO-H. It has four identical channels that simultaneously process the CCD signals. Distinctive capability of analog-to-digital conversion enables us to construct a CCD camera body that…
▽ More
We report on the performance of an analog application-specific integrated circuit (ASIC) developed aiming for the front-end electronics of the X-ray CCDcamera system onboard the next X-ray astronomical satellite, ASTRO-H. It has four identical channels that simultaneously process the CCD signals. Distinctive capability of analog-to-digital conversion enables us to construct a CCD camera body that outputs only digital signals. As the result of the front-end electronics test, it works properly with low input noise of =<30 uV at the pixel rate below 100 kHz. The power consumption is sufficiently low of about 150 mW/chip. The input signal range of 720 mV covers the effective energy range of the typical X-ray photon counting CCD (up to 20 keV). The integrated non-linearity is 0.2% that is similar as those of the conventional CCDs in orbit. We also performed a radiation tolerance test against the total ionizing dose (TID) effect and the single event effect. The irradiation test using 60Co and proton beam showed that the ASIC has the sufficient tolerance against TID up to 200 krad, which absolutely exceeds the expected amount of dose during the period of operating in a low-inclination low-earth orbit. The irradiation of Fe ions with the fluence of 5.2x10^8 Ion/cm2 resulted in no single event latchup (SEL), although there were some possible single event upsets. The threshold against SEL is higher than 1.68 MeV cm^2/mg, which is sufficiently high enough that the SEL event should not be one of major causes of instrument downtime in orbit.
△ Less
Submitted 11 February, 2011;
originally announced February 2011.
-
Detection of the Direct Hyperfine Transition of Positronium Atoms using sub-THz High-power Radiation
Authors:
T. Suehara,
A. Miyazaki,
T. Yamazaki,
G. Akimoto,
A. Ishida,
T. Namba,
S. Asai,
T. Kobayashi,
H. Saito,
M. Yoshida,
T. Idehara,
I. Ogawa,
Y. Urushizaki,
S. Sabchevski
Abstract:
Hyperfine splitting of positronium is an important parameter for particle physics. This paper gives experimental techniques and results of R&D studies of our experiment to observe direct hyperfine transition of ortho-positronium to para-positronium.
Hyperfine splitting of positronium is an important parameter for particle physics. This paper gives experimental techniques and results of R&D studies of our experiment to observe direct hyperfine transition of ortho-positronium to para-positronium.
△ Less
Submitted 6 July, 2010;
originally announced July 2010.
-
Probing the Energy Structure of Positronium with a 203 GHz Fabry-Perot Cavity
Authors:
T Suehara,
A Miyazaki,
A Ishida,
T Namba,
S Asai,
T Kobayashi,
H Saito,
M Yoshida,
T Idehara,
I Ogawa,
S Kobayashi,
Y Urushizaki,
S Sabchevski
Abstract:
Positronium is an ideal system for the research of the bound state QED. The hyperfine splitting of positronium (Ps-HFS: about 203 GHz) is sensitive to new physics beyond the Standard Model via a vacuum oscillation between an ortho-Ps and a virtual photon. Previous experimental results of the Ps-HFS show 3.9 sigma(15 ppm) discrepancy from the QED calculation. All previous experiments used an indire…
▽ More
Positronium is an ideal system for the research of the bound state QED. The hyperfine splitting of positronium (Ps-HFS: about 203 GHz) is sensitive to new physics beyond the Standard Model via a vacuum oscillation between an ortho-Ps and a virtual photon. Previous experimental results of the Ps-HFS show 3.9 sigma(15 ppm) discrepancy from the QED calculation. All previous experiments used an indirect method with static magnetic field to cause Zeeman splitting (a few GHz) between triplet states of ortho-Ps, from which the HFS value was derived. One possible systematic error source of the indirect method is the static magnetic field. We are develo** a new direct measurement system of the Ps-HFS without static magnetic field. In this measurement we use a gyrotron, a novel sub-THz light source, with a high-Finesse Fabry-Perot cavity to obtain enough radiation power at 203 GHz. The present status of the optimization studies and current design of the experiment are described.
△ Less
Submitted 6 July, 2010;
originally announced July 2010.
-
Precise measurement of Hyper Fine Structure of positronium using sub-THz light
Authors:
S. Asai,
T. Suehara,
T. Yamazaki,
G. Akimoto,
A. Miyazaki,
T. Namba,
T. Kobayashi,
H. Saito,
T. Idehara,
I. Ogawa,
Y. Urishizaki,
S. Sabchevski
Abstract:
Positronium is an ideal system for the research of the QED, especially for the QED in bound state. The discrepancy of 3.9σis found recently between the measured HFS values and the QED prediction ($O(α^3)$). It might be due to the contribution of the unknown new physics or the systematic problems in the previous all measurements. We propose new method to measure HFS precisely and directly. A gyrotr…
▽ More
Positronium is an ideal system for the research of the QED, especially for the QED in bound state. The discrepancy of 3.9σis found recently between the measured HFS values and the QED prediction ($O(α^3)$). It might be due to the contribution of the unknown new physics or the systematic problems in the previous all measurements. We propose new method to measure HFS precisely and directly. A gyrotron, a novel sub-THz light source is used with a high-finesse Fabry-Pérot cavity to obtain enough radiation power at 203 GHz. The present status of the optimization studies and current design of the experiment are described.
△ Less
Submitted 15 April, 2010; v1 submitted 22 March, 2010;
originally announced March 2010.
-
Precise measurement of HFS of positronium
Authors:
A. Ishida,
G. Akimoto,
K. Kato,
T. Suehara,
T. Namba,
S. Asai,
T. Kobayashi,
H. Saito,
M. Yoshida,
K. Tanaka,
A. Yamamoto,
I. Ogawa,
S. Kobayashi,
T. Idehara
Abstract:
The ground state hyperfine splitting in positronium, $Δ_{\mathrm{HFS}}$, is sensitive to high order corrections of QED. A new calculation up to $O(α^3)$ has revealed a $3.9 σ$ discrepancy between the QED prediction and the experimental results. This discrepancy might either be due to systematic problems in the previous experiments or to contributions beyond the Standard Model. We propose an expe…
▽ More
The ground state hyperfine splitting in positronium, $Δ_{\mathrm{HFS}}$, is sensitive to high order corrections of QED. A new calculation up to $O(α^3)$ has revealed a $3.9 σ$ discrepancy between the QED prediction and the experimental results. This discrepancy might either be due to systematic problems in the previous experiments or to contributions beyond the Standard Model. We propose an experiment to measure $Δ_{\mathrm{HFS}}$ employing new methods designed to remedy the systematic errors which may have affected the previous experiments. Our experiment will provide an independent check of the discrepancy. The measurement is in progress and a preliminary result of $Δ_{\mathrm{HFS}} = 203.399 \pm 0.029 \mathrm{GHz} (143 \mathrm{ppm})$ has been obtained. A measurement with a precision of O(1) ppm is expected within a few years.
△ Less
Submitted 22 December, 2009;
originally announced December 2009.
-
Precision measurements of positronium decay rate and energy level
Authors:
S. Asai,
Y. Kataoka,
T. Kobayashi,
T. Namba,
T. Suehara,
G. Akimoto,
A. Ishida,
M. M. Hashimoto,
H. Saito,
T. Idehara,
M. Yoshida
Abstract:
Positronium is an ideal system for the research of the bound state QED. New precise measurement of orthopositronium decay rate has been performed with an accuracy of 150 ppm, and the result combined with the last three is 7.0401 +- 0.0007 mu s^-1. It is the first result to validate the 2nd order correction. The Hyper Fine Splitting of positronium is sensitive to the higher order corrections of t…
▽ More
Positronium is an ideal system for the research of the bound state QED. New precise measurement of orthopositronium decay rate has been performed with an accuracy of 150 ppm, and the result combined with the last three is 7.0401 +- 0.0007 mu s^-1. It is the first result to validate the 2nd order correction. The Hyper Fine Splitting of positronium is sensitive to the higher order corrections of the QED prediction and also to the new physics beyond Standard Model via the quantum oscillation into virtual photon. The discrepancy of 3.5 sigma is found recently between the measured values and the QED prediction (O(alpha^3)). It might be due to the contribution of the new physics or the systematic problems in the previous measurements: (non-thermalized Ps and non-uniformity of the magnetic field). We propose new methods to measure HFS precisely without the these uncertainties.
△ Less
Submitted 30 May, 2008;
originally announced May 2008.
-
Plasma scattering measurement using a submillimeter wave gyrotron as a radiation source
Authors:
Isamu Ogawa,
Toshitaka Idehara,
Yutaka Itakura,
Masahiko Myodo,
Toshihiro Hori,
Takaki Hatae
Abstract:
Plasma scattering measurement is effective technique to observe low frequency density fluctuations excited in plasma. The spatial and wave number resolutions and the S/N ratio of measurement depend on the wavelength range, the size and the intensity of a probe beam. A well-collimated, submillimeter wave beam is suitable for improving the spatial and wave number resolutions. Application of high f…
▽ More
Plasma scattering measurement is effective technique to observe low frequency density fluctuations excited in plasma. The spatial and wave number resolutions and the S/N ratio of measurement depend on the wavelength range, the size and the intensity of a probe beam. A well-collimated, submillimeter wave beam is suitable for improving the spatial and wave number resolutions. Application of high frequency gyrotron is effective in improving the S/N ratio of the measurement because of its capacity to deliver high power. Unlike the molecular vapor lasers, the gyrotrons generate diverging beam of radiation with TEmn mode structure. It is therefore necessary to convert the output radiation into a Gaussian beam. A quasi-optical antenna is a suitable element for the conversion system under consideration since it is applicable to several TE0n and TE1n modes. In order to apply the gyrotron to plasma scattering measurement, we have stabilized the output (P=110W, f=354GHz) of gyrotron up to the level (DP/P<1 %, Df<10 kHz). The gyrotron output can be stabilized by decreasing the fluctuation of the cathode potential.
△ Less
Submitted 25 November, 2004; v1 submitted 19 November, 2004;
originally announced November 2004.
-
Development of submillimeter wave source Gyrotron FU series for plasma diagnostics
Authors:
Toshitaka Idehara,
Isamu Ogawa,
Seitaro Mitsudo,
Masaki Kamada,
Osamu Watanabe,
La Agusu
Abstract:
Our gyrotrons developed in Fukui University, Research Center for Development of Far Infrared Region (FIR FU) are high frequency, medium power gyrotrons as millimeter to submillimeter wave radiation sources for application to new far-infrared technologies including plasma diagnostics. We have already developed Gyrotron FU Series which consists of 8 gyrotrons. The gyrotron series has achieved freq…
▽ More
Our gyrotrons developed in Fukui University, Research Center for Development of Far Infrared Region (FIR FU) are high frequency, medium power gyrotrons as millimeter to submillimeter wave radiation sources for application to new far-infrared technologies including plasma diagnostics. We have already developed Gyrotron FU Series which consists of 8 gyrotrons. The gyrotron series has achieved frequency tuneability in wide range (from 38 GHz to 889 GHz). The highest frequency is corresponding to a wavelength of 337 micrometers. This is a current record for high frequency operation of gyrotron. Recently, we have developed a high harmonic gyrotron with an axis-encircling electron beam and a THz gyrotron with a pulse magnet. In this presentation, the present status of Gyrotron FU Series is described.
△ Less
Submitted 18 November, 2004;
originally announced November 2004.