-
Performance of the Full-equipped Spin Flip Chopper For Neutron Lifetime Experiment at J-PARC
Authors:
K. Mishima,
G. Ichikawa,
Y. Fuwa,
T. Hasegawa,
M. Hino,
R. Hosokawa,
T. Ino,
Y. Iwashita,
M. Kitaguchi,
S. Matsuzaki,
T. Mogi,
H. Okabe,
T. Oku,
T. Okudaira,
Y. Seki,
H. E. Shimizu,
H. M. Shimizu,
S. Takahashi,
M. Tanida,
S. Yamashita,
M. Yokohashi,
T. Yoshioka
Abstract:
To solve the ``neutron lifetime puzzle,'' where measured neutron lifetimes differ depending on the measurement methods, an experiment with pulsed neutron beam at J-PARC is in progress. In this experiment, neutrons are bunched into 40-cm lengths using a spin flip chopper (SFC), where the statistical sensitivity was limited by the aperture size of the SFC. The SFC comprises three sets of magnetic su…
▽ More
To solve the ``neutron lifetime puzzle,'' where measured neutron lifetimes differ depending on the measurement methods, an experiment with pulsed neutron beam at J-PARC is in progress. In this experiment, neutrons are bunched into 40-cm lengths using a spin flip chopper (SFC), where the statistical sensitivity was limited by the aperture size of the SFC. The SFC comprises three sets of magnetic supermirrors and two resonant spin flippers. In this paper, we discuss an upgrade to enlarge the apertures of the SFC. The improved SFC achieved a signal-to-noise ratio of 250--400, which is comparable to the previous one. The statistics per unit time of the neutron lifetime experiment increased 2.8 times with the upgrade. Consequently, the time required to reach an accuracy of 1~s in the neutron lifetime experiment was reduced from 590 to 170~days, which is a significant reduction in time. This improvement in statistical accuracy will also contribute to the reduction of systematic uncertainties, such as background evaluation, fostering further advancements in the neutron lifetime experiments at J-PARC.
△ Less
Submitted 20 December, 2023;
originally announced December 2023.
-
Development of Neutron Interferometer using Multilayer Mirrors and Measurements of Neutron-Nuclear Scattering Length with Pulsed Neutron Source
Authors:
Takuhiro Fujiie,
Masahiro Hino,
Takuya Hosobata,
Go Ichikawa,
Masaaki Kitaguchi,
Kenji Mishima,
Yoshichika Seki,
Hirohiko M. Shimizu,
Yutaka Yamagata
Abstract:
This study entailed the successful deployment of a novel neutron interferometer that utilizes multilayer mirrors. The apparatus facilitates a precise evaluation of the wavelength dependence of interference fringes utilizing a pulsed neutron source. Our interferometer achieved an impressive precision of 0.02 rad within a 20-min of recording time. Compared to systems using silicon crystals, the meas…
▽ More
This study entailed the successful deployment of a novel neutron interferometer that utilizes multilayer mirrors. The apparatus facilitates a precise evaluation of the wavelength dependence of interference fringes utilizing a pulsed neutron source. Our interferometer achieved an impressive precision of 0.02 rad within a 20-min of recording time. Compared to systems using silicon crystals, the measurement sensitivity was maintained even when using a simplified disturbance suppressor. By segregating beam paths entirely, we achieved successful measurements of neutron-nuclear scattering lengths across various samples. The values measured for Si, Al, and Ti were in agreement with those found in the literature, while V showed a disparity of 45%. This discrepancy may be attributable to impurities encountered in previous investigations. The accuracy of measurements can be enhanced further by mitigating systematic uncertainties that are associated with neutron wavelength, sample impurity, and thickness. This novel neutron interferometer enables us to measure fundamental parameters, such as the neutron-nuclear scattering length of materials, with a precision that surpasses that of conventional interferometers.
△ Less
Submitted 5 October, 2023; v1 submitted 19 July, 2023;
originally announced August 2023.
-
A diffuse scattering model of ultracold neutrons on wavy surfaces
Authors:
S. Imajo,
H. Akatsuka,
K. Hatanaka,
T. Higuchi,
G. Ichikawa,
S. Kawasaki,
M. Kitaguchi,
R. Mammei,
R. Matsumiya,
K. Mishima,
R. Picker,
W. Schreyer,
H. M. Shimizu
Abstract:
Metal tubes plated with nickel-phosphorus are used in many fundamental physics experiments using ultracold neutrons (UCN) because of their ease of fabrication. These tubes are usually polished to a average roughness of 25-150 nm. However, there is no scattering model that accurately describes UCN scattering on such a rough guide surface with a mean-square roughness larger than 5 nm. We therefore d…
▽ More
Metal tubes plated with nickel-phosphorus are used in many fundamental physics experiments using ultracold neutrons (UCN) because of their ease of fabrication. These tubes are usually polished to a average roughness of 25-150 nm. However, there is no scattering model that accurately describes UCN scattering on such a rough guide surface with a mean-square roughness larger than 5 nm. We therefore developed a scattering model for UCN in which scattering from random surface waviness with a size larger than the UCN wavelength is described by a microfacet Bidirectional Reflectance Distribution Function model (mf-BRDF model), and scattering from smaller structures by the Lambert's cosine law (Lambert model). For the surface waviness, we used the statistical distribution of surface slope measured by an atomic force microscope on a sample piece of guide tube as input of the model. This model was used to describe UCN transmission experiments conducted at the pulsed UCN source at J-PARC. In these experiments, a UCN beam collimated to a divergence angle smaller than $\pm 6^{\circ}$ was directed into a guide tube with a mean-square roughness of 6.4 nm to 17 nm at an oblique angle, and the UCN transport performance and its time-of-flight distribution were measured while changing the angle of incidence. The mf-BRDF model combined with the Lambert model with scattering probability $p_{L} = 0.039\pm0.003$ reproduced the experimental results well. We have thus established a procedure to evaluate the characteristics of UCN guide tubes with a surface roughness of approximately 10 nm.
△ Less
Submitted 30 July, 2023; v1 submitted 27 March, 2023;
originally announced March 2023.
-
Study on the reusability of fluorescent nuclear track detectors using optical bleaching
Authors:
Abdul Muneem,
Junya Yoshida,
Hiroyuki Ekawa,
Masahiro Hino,
Katsuya Hirota,
Go Ichikawa,
Ayumi Kasagi,
Masaaki Kitaguchi,
Satoshi Kodaira,
Kenji Mishima,
Jameel-Un Nabi,
Manami Nakagawa,
Michio Sakashita,
Norihito Saito,
Takehiko R. Saito,
Satoshi Wada,
Nakahiro Yasuda
Abstract:
Fluorescent nuclear track detectors (FNTDs) based on Al${_2}$O${_3}$:C,Mg crystals are luminescent detectors that can be used for dosimetry and detection of charged particles and neutrons. These detectors can be utilised for imaging applications where a reasonably high track density, approximately of the order of 1 $\times$ $10^4$ tracks in an area of 100 $\times$ 100 $μ$m$^2$, is required. To inv…
▽ More
Fluorescent nuclear track detectors (FNTDs) based on Al${_2}$O${_3}$:C,Mg crystals are luminescent detectors that can be used for dosimetry and detection of charged particles and neutrons. These detectors can be utilised for imaging applications where a reasonably high track density, approximately of the order of 1 $\times$ $10^4$ tracks in an area of 100 $\times$ 100 $μ$m$^2$, is required. To investigate the reusability of FNTDs for imaging applications, we present an approach to perform optical bleaching under the required track density conditions. The reusability was assessed through seven irradiation-bleaching cycles. For the irradiation, the studied FNTD was exposed to alpha-particles from an $^{241}$Am radioactive source. The optical bleaching was performed by means of ultraviolet laser light with a wavelength of 355 nm. Three dedicated regions on a single FNTD with different accumulated track densities and bleaching conditions were investigated. After every irradiation-bleaching cycle, signal-to-noise ratio was calculated to evaluate FNTD performance. It is concluded that FNTDs can be reused at least seven times for applications where accumulation of a high track density is required.
△ Less
Submitted 3 November, 2022;
originally announced November 2022.
-
Investigation of the neutron imaging applications using fine-grained nuclear emulsion
Authors:
Abdul Muneem,
Junya Yoshida,
Hiroyuki Ekawa,
Masahiro Hino,
Katsuya Hirota,
Go Ichikawa,
Ayumi Kasagi,
Masaaki Kitaguchi,
Naoto Muto,
Kenji Mishima,
Jameel-Un Nabi,
Manami Nakagawa,
Naotaka Naganawa,
Takehiko R. Saito
Abstract:
Neutron imaging is a non-destructive inspection technique with a wide range of applications. One of the important aspects concerning neutron imaging is achieving micrometer-scale spatial resolution. Develo** a neutron detector with a high resolution is a challenging task. Neutron detectors, based on fine-grained nuclear emulsion, may be suitable for high resolution neutron imaging applications.…
▽ More
Neutron imaging is a non-destructive inspection technique with a wide range of applications. One of the important aspects concerning neutron imaging is achieving micrometer-scale spatial resolution. Develo** a neutron detector with a high resolution is a challenging task. Neutron detectors, based on fine-grained nuclear emulsion, may be suitable for high resolution neutron imaging applications. High track density is a necessary requirement to improve the quality of neutron imaging. However, the available track analysis methods are difficult to apply under high track density conditions. Simulated images were used to determine the required track density for neutron imaging. It was concluded that a track density of the order of $10^4$ tracks per 100 $\times$ 100 $μ$m$^2$ is sufficient to utilize neutron detectors for imaging applications. The contrast resolution was also investigated for the image data sets with various track densities and neutron transmission rates. Moreover, experiments were performed for neutron imaging of the gadolinium-based gratings with known geometries. The structure of gratings was successfully resolved. The calculated 1$σ$ 10-90 \% edge response, using the gray scale optical images of the grating slit with a periodic structure of 9 $μ$m, was 0.945 $\pm$ 0.004 $μ$m.
△ Less
Submitted 6 December, 2022; v1 submitted 30 October, 2022;
originally announced October 2022.
-
Characterization of electroless nickel-phosphorus plating for ultracold-neutron storage
Authors:
H. Akatsuka,
T. Andalib,
B. Bell,
J. Berean-Dutcher,
N. Bernier,
C. P. Bidinosti,
C. Cude-Woods,
S. A. Currie,
C. A. Davis,
B. Franke,
R. Gaur,
P. Giampa,
S. Hansen-Romu,
M. T. Hassan,
K. Hatanaka,
T. Higuchi,
C. Gibson,
G. Ichikawa,
I. Ide,
S. Imajo,
T. M. Ito,
B. Jamieson,
S. Kawasaki,
M. Kitaguchi,
W. Klassen
, et al. (29 additional authors not shown)
Abstract:
Electroless nickel plating is an established industrial process that provides a robust and relatively low-cost coating suitable for transporting and storing ultracold neutrons (UCN). Using roughness measurements and UCN-storage experiments we characterized UCN guides made from polished aluminum or stainless-steel tubes plated by several vendors. All electroless nickel platings were similarly suite…
▽ More
Electroless nickel plating is an established industrial process that provides a robust and relatively low-cost coating suitable for transporting and storing ultracold neutrons (UCN). Using roughness measurements and UCN-storage experiments we characterized UCN guides made from polished aluminum or stainless-steel tubes plated by several vendors. All electroless nickel platings were similarly suited for UCN storage with an average loss probability per wall bounce of $2.8\cdot10^{-4}$ to $4.1\cdot10^{-4}$ for energies between 90 neV and 190 neV, or a ratio of imaginary to real Fermi potential $η$ of $1.7\cdot10^{-4}$ to $3.3\cdot10^{-4}$. Measurements at different elevations indicate that the energy dependence of UCN losses is well described by the imaginary Fermi potential. Some special considerations are required to avoid an increase in surface roughness during the plating process and hence a reduction in UCN transmission. Increased roughness had only a minor impact on storage properties. Based on these findings we chose a vendor to plate the UCN-production vessel that will contain the superfluid-helium converter for the new TRIUMF UltraCold Advanced Neutron (TUCAN) source, achieving acceptable UCN-storage properties with ${η=3.5(5)\cdot10^{-4}}$.
△ Less
Submitted 7 February, 2023; v1 submitted 10 August, 2022;
originally announced August 2022.
-
The Precision nEDM Measurement with UltraCold Neutrons at TRIUMF
Authors:
Ryohei Matsumiya,
Hiroaki Akatsuka,
Chris P. Bidinosti,
Charles A. Davis,
Beatrice Franke,
Derek Fujimoto,
Michael T. W. Gericke,
Pietro Giampa,
Robert Golub,
Sean Hansen-Romu,
Kichiji Hatanaka,
Tomohiro Hayamizu,
Takashi Higuchi,
Go Ichikawa,
Sohei Imajo,
Blair Jamieson,
Shinsuke Kawasaki,
Masaaki Kitaguchi,
Wolfgang Klassen,
Emma Klemets,
Akira Konaka,
Elie Korkmaz,
Ekaterina Korobkina,
Florian Kuchler,
Maedeh Lavvaf
, et al. (23 additional authors not shown)
Abstract:
The TRIUMF Ultra-Cold Advanced Neutron (TUCAN) collaboration aims at a precision neutron electric dipole moment (nEDM) measurement with an uncertainty of $10^{-27}\,e\cdot\mathrm{cm}$, which is an order-of-magnitude better than the current nEDM upper limit and enables us to test Supersymmetry. To achieve this precision, we are develo** a new high-intensity ultracold neutron (UCN) source using su…
▽ More
The TRIUMF Ultra-Cold Advanced Neutron (TUCAN) collaboration aims at a precision neutron electric dipole moment (nEDM) measurement with an uncertainty of $10^{-27}\,e\cdot\mathrm{cm}$, which is an order-of-magnitude better than the current nEDM upper limit and enables us to test Supersymmetry. To achieve this precision, we are develo** a new high-intensity ultracold neutron (UCN) source using super-thermal UCN production in superfluid helium (He-II) and a nEDM spectrometer. The current development status of them is reported in this article.
△ Less
Submitted 18 July, 2022;
originally announced July 2022.
-
Study of Thin Iron Films for Polarization Analysis of Ultracold Neutrons
Authors:
Hiroaki Akatsuka,
Takashi Higuchi,
Sean Hansen-Romu,
Kichiji Hatanaka,
Tomohiro Hayamizu,
Masahiro Hino,
Go Ichikawa,
Sohei Imajo,
Blair Jamieson,
Shinsuke Kawasaki,
Masaaki Kitaguchi,
Ryohei Matsumiya,
Kenji Mishima
Abstract:
The TUCAN (TRIUMF Ultra-Cold Advanced Neutron) collaboration aims to search for the neutron electric dipole moment (nEDM) with unprecedented precision. One of the essential elements for the nEDM measurement is a polarization analyzer of ultracold neutrons (UCNs), whose main component is a magnetized thin iron film. Several thin iron films were deposited on aluminum and silicon ubstrates and were c…
▽ More
The TUCAN (TRIUMF Ultra-Cold Advanced Neutron) collaboration aims to search for the neutron electric dipole moment (nEDM) with unprecedented precision. One of the essential elements for the nEDM measurement is a polarization analyzer of ultracold neutrons (UCNs), whose main component is a magnetized thin iron film. Several thin iron films were deposited on aluminum and silicon ubstrates and were characterized by vibrating sample magnetometry and cold-neutron reflectometry. A magnetic field required to saturate the iron film is $\sim$12 kA/m for those on the aluminum substrates and 6.4 kA/m for the silicon substrates. The magnetic potential of the iron films on the Si substrate was estimated to be 2 T by the neutron reflectometry, which is sufficient performance for an UCN polarization analyzer of the nEDM measurement.
△ Less
Submitted 18 July, 2022;
originally announced July 2022.
-
A Novel Nuclear Emulsion Detector for Measurement of Quantum States of Ultracold Neutrons in the Earth's Gravitational Field
Authors:
Naoto Muto,
Hartmut Abele,
Tomoko Ariga,
Joachim Bosina,
Masahiro Hino,
Katsuya Hirota,
Go Ichikawa,
Tobias Jenke,
Hiroaki Kawahara,
Shinsuke Kawasaki,
Masaaki Kitaguchi,
Jakob Micko,
Kenji Mishima,
Naotaka Naganawa,
Mitsuhiro Nakamura,
Stéphanie Roccia,
Osamu Sato,
René I. P. Sedmik,
Yoshichika Seki,
Hirohiko M. Shimizu,
Satomi Tada,
Atsuhiro Umemoto
Abstract:
Hypothetical short-range interactions could be detected by measuring the wavefunctions of ultracold neutrons (UCNs) on a mirror bounded by the Earth's gravitational field. The Searches require detectors with higher spatial resolution. We are develo** a UCN detector for the with a high spatial resolution, which consists of a Si substrate, a thin converter layer including $^{10}$B$_{4}$C, and a la…
▽ More
Hypothetical short-range interactions could be detected by measuring the wavefunctions of ultracold neutrons (UCNs) on a mirror bounded by the Earth's gravitational field. The Searches require detectors with higher spatial resolution. We are develo** a UCN detector for the with a high spatial resolution, which consists of a Si substrate, a thin converter layer including $^{10}$B$_{4}$C, and a layer of fine-grained nuclear emulsion. Its resolution was estimated to be less than 100 nm by fitting tracks of either $^{7}$Li nuclei or $α$-particles, which were created when neutrons interacted with the $^{10}$B$_{4}$C layer. For actual measurements of the spatial distributions, the following two improvements were made: The first was to establish a method to align microscopic images with high accuracy within a wide region of 65 mm $\times$ 0.2 mm. We created reference marks of 1 $μ$m and 5 $μ$m diameter with an interval of 50 $μ$m and 500 $μ$m, respectively, on the Si substrate by electron beam lithography and realized a position accuracy of less than 30 nm. The second was to build a holder that could maintain the atmospheric pressure around the nuclear emulsion to utilize it under vacuum during exposure to UCNs. The intrinsic resolution of the improved detector was estimated by evaluating the blur of a transmission image of a gadolinium grating taken by cold neutrons as better than 0.56 $\pm$ 0.08 $μ$m, which included the grating accuracy. A test exposure to UCNs was conducted to obtain the spatial distribution of UCNs in the Earth's gravitational field. Although the test was successful, a blurring of 6.9 $μ$m was found in the measurements, compared with a theoretical curve. We identified the blurring caused by the refraction of UCNs due to the roughness of the upstream surface of the substrate. Polishing of the surface makes the resolution less than 100 nm.
△ Less
Submitted 26 May, 2022; v1 submitted 12 January, 2022;
originally announced January 2022.
-
Precise Neutron Lifetime Measurement Using Pulsed Neutron Beams at J-PARC
Authors:
N. Sumi,
K. Hirota,
G. Ichikawa,
T. Ino,
Y. Iwashita,
S. Kajiwara,
Y. Kato,
M. Kitaguchi,
K. Mishima,
K. Morikawa,
T. Mogi,
H. Oide,
H. Okabe,
H. Otono,
T. Shima,
H. M. Shimizu,
Y. Sugisawa,
T. Tanabe,
S. Yamashita,
K. Yano,
T. Yoshioka
Abstract:
A neutron decays into a proton, an electron, and an anti-neutrino through the beta-decay process. The decay lifetime ($\sim$880 s) is an important parameter in the weak interaction. For example, the neutron lifetime is a parameter used to determine the |$V_{\rm ud}$| parameter of the CKM quark mixing matrix. The lifetime is also one of the input parameters for the Big Bang Nucleosynthesis, which p…
▽ More
A neutron decays into a proton, an electron, and an anti-neutrino through the beta-decay process. The decay lifetime ($\sim$880 s) is an important parameter in the weak interaction. For example, the neutron lifetime is a parameter used to determine the |$V_{\rm ud}$| parameter of the CKM quark mixing matrix. The lifetime is also one of the input parameters for the Big Bang Nucleosynthesis, which predicts light element synthesis in the early universe. However, experimental measurements of the neutron lifetime today are significantly different (8.4 s or 4.0$σ$) depending on the methods. One is a bottle method measuring surviving neutron in the neutron storage bottle. The other is a beam method measuring neutron beam flux and neutron decay rate in the detector. There is a discussion that the discrepancy comes from unconsidered systematic error or undetectable decay mode, such as dark decay. A new type of beam experiment is performed at the BL05 MLF J-PARC. This experiment measured neutron flux and decay rate simultaneously with a time projection chamber using a pulsed neutron beam. We will present the world situation of neutron lifetime and the latest results at J-PARC.
△ Less
Submitted 19 February, 2021;
originally announced February 2021.
-
Neutron lifetime measurement with pulsed cold neutrons
Authors:
K. Hirota,
G. Ichikawa,
S. Ieki,
T. Ino,
Y. Iwashita,
M. Kitaguchi,
R. Kitahara,
J. Koga,
K. Mishima,
T. Mogi,
K. Morikawa,
A. Morishita,
N. Nagakura,
H. Oide,
H. Okabe,
H. Otono,
Y. Seki,
D. Sekiba,
T. Shima,
H. M. Shimizu,
N. Sumi,
H. Sumino,
T. Tomita,
H. Uehara,
T. Yamada
, et al. (4 additional authors not shown)
Abstract:
The neutron lifetime has been measured by comparing the decay rate with the reaction rate of $^3$He nuclei of a pulsed neutron beam from the spallation neutron source at the Japan Proton Accelerator Research Complex (J-PARC). The decay rate and the reaction rate were determined by simultaneously detecting electrons from the neutron decay and protons from the $^3$He(n,p)$^3$H reaction using a gas c…
▽ More
The neutron lifetime has been measured by comparing the decay rate with the reaction rate of $^3$He nuclei of a pulsed neutron beam from the spallation neutron source at the Japan Proton Accelerator Research Complex (J-PARC). The decay rate and the reaction rate were determined by simultaneously detecting electrons from the neutron decay and protons from the $^3$He(n,p)$^3$H reaction using a gas chamber of which working gas contains diluted $^3$He. The measured neutron lifetime was $898\,\pm\,10\,_{\rm stat}\,^{+15}_{-18}\,_{\rm sys}\,$s.
△ Less
Submitted 25 November, 2020; v1 submitted 22 July, 2020;
originally announced July 2020.
-
Precision Measurement of the Position-space Wave Functions of Gravitationally Bound Ultracold Neutrons
Authors:
Y. Kamiya,
G. Ichikawa,
S. Komamiya
Abstract:
Gravity is the most familiar force at our natural length scale. However, it is still exotic from the view point of particle physics. The first experimental study of quantum effects under gravity was performed using a cold neutron beam in 1975. Following this, an investigation of gravitationally bound quantum states using ultracold neutrons was started in 2002. This quantum bound system is now well…
▽ More
Gravity is the most familiar force at our natural length scale. However, it is still exotic from the view point of particle physics. The first experimental study of quantum effects under gravity was performed using a cold neutron beam in 1975. Following this, an investigation of gravitationally bound quantum states using ultracold neutrons was started in 2002. This quantum bound system is now well understood, and one can use it as a tunable tool to probe gravity. In this paper, we review a recent measurement of position-space wave functions of such gravitationally bound states, and discuss issues related to this analysis, such as neutron loss models in a thin neutron guide, the formulation of phase space quantum mechanics, and UCN position sensitive detectors. The quantum modulation of neutron bound states measured in this experiment shows good agreement with the prediction from quantum mechanics.
△ Less
Submitted 9 April, 2015;
originally announced April 2015.
-
Observation of the Spatial Distribution of Gravitationally Bound Quantum States of Ultracold Neutrons and Its Derivation Using the Wigner Function
Authors:
G. Ichikawa,
S. Komamiya,
Y. Kamiya,
Y. Minami,
M. Tani,
P. Geltenbort,
K. Yamamura,
M. Nagano,
T. Sanuki,
S. Kawasaki,
M. Hino,
M. Kitaguchi
Abstract:
Ultracold neutrons (UCNs) can be bound by the potential of terrestrial gravity and a reflecting mirror. The wave function of the bound state has characteristic modulations. We carried out an experiment to observe the vertical distribution of the UCNs above such a mirror at Institut Laue-Langevin in 2011. The observed modulation is in good agreement with that prediction by quantum mechanics using t…
▽ More
Ultracold neutrons (UCNs) can be bound by the potential of terrestrial gravity and a reflecting mirror. The wave function of the bound state has characteristic modulations. We carried out an experiment to observe the vertical distribution of the UCNs above such a mirror at Institut Laue-Langevin in 2011. The observed modulation is in good agreement with that prediction by quantum mechanics using the Wigner function. The spatial resolution of the detector system is estimated to be 0.7 micro meter. This is the first observation of gravitationally bound states of UCNs with submicron spatial resolution.
△ Less
Submitted 10 March, 2014; v1 submitted 5 April, 2013;
originally announced April 2013.
-
Development of a Pixel Detector for Ultra-Cold Neutrons
Authors:
S. Kawasaki,
G. Ichikawa,
M. Hino,
Y. Kamiya,
M. Kitaguchi,
S. Komamiya,
T. Sanuki,
S. Sonoda
Abstract:
A pixel detector with high spatial resolution and temporal information for ultra-cold neutrons is developed based on a commercial CCD on which a neutron converter is attached. 10B and 6Li are tested for the neutron converter and 10B is found to be more suitable based on efficiency and spatial resolution. The pixel detector has an efficiency of 44.1 +- 1.1% and a spatial resolution of 2.9 +- 0.1…
▽ More
A pixel detector with high spatial resolution and temporal information for ultra-cold neutrons is developed based on a commercial CCD on which a neutron converter is attached. 10B and 6Li are tested for the neutron converter and 10B is found to be more suitable based on efficiency and spatial resolution. The pixel detector has an efficiency of 44.1 +- 1.1% and a spatial resolution of 2.9 +- 0.1 um (1 sigma).
△ Less
Submitted 2 February, 2010;
originally announced February 2010.