RF-coil with variable resonant frequency for multiheteronuclear ultra-high field MRI
Authors:
V. A. Ivanov,
A. A. Hurshkainen,
G. A. Solomakha,
M. A. Zubkov
Abstract:
Here we propose double-coil setup to allow high signal-to-noise ratio broad-range heteronuclear magnetic resonance imaging experiments: two independent coils, one of them tuned to $^{1}$H frequency to perform anatomical $^{1}$H imaging, and another one, metamaterial-inspired coil, tuned to the X-nucleus frequency. In this work our goal was to design a broad-range X-nuclei coil to cover $^{2}$H,…
▽ More
Here we propose double-coil setup to allow high signal-to-noise ratio broad-range heteronuclear magnetic resonance imaging experiments: two independent coils, one of them tuned to $^{1}$H frequency to perform anatomical $^{1}$H imaging, and another one, metamaterial-inspired coil, tuned to the X-nucleus frequency. In this work our goal was to design a broad-range X-nuclei coil to cover $^{2}$H, $^{11}$B, $^{13}$C, $^{23}$Na, $^{7}$Li and $^{31}$P nuclear magnetic resonance frequencies, and to combine it with $^{1}$H coil in one setup. The system was designed for 11.7 T scanner, i.e., with 76-203 MHz frequency tuning range for the X-nuclei and tuned to 500 MHz for the proton coil. X-nuclei coil operates via excitation of the fundamental eigenmode of an array of parallel non-magnetic wires. The excitation of the array is provided via non-resonant feeding loop inductively coupled to the resonator. In order to tune the X-coil over such a wide range, both structural capacitance and inductance of the coil were made variable; narrow range tuning of the $^{1}$H coil is achieved via conventional tuning-matching circuit. Here, the design principle and setup tunability were investigated in simulations and experimentally.
△ Less
Submitted 16 March, 2020;
originally announced March 2020.
-
Experimental observation of hybrid TE-TM polarized surface waves supported by hyperbolic metasurface
Authors:
Oleh Y. Yermakov,
Anna A. Hurshkainen,
Dmitry A. Dobrykh,
Polina V. Kapitanova,
Ivan V. Iorsh,
Stanislav B. Glybovski,
y,
Andrey A. Bogdanov
Abstract:
Hyperbolic metasurfaces have gained significant attention due to their extraordinary electromagnetic properties to control propagating plane waves, but the excitation and propagation of the surface plasmon-polaritons at hyperbolic metasurfaces, called hyperbolic plasmons, have been experimentally observed just recently. However, the advantages of the hyperbolic plasmons, such as hybrid TE-TM polar…
▽ More
Hyperbolic metasurfaces have gained significant attention due to their extraordinary electromagnetic properties to control propagating plane waves, but the excitation and propagation of the surface plasmon-polaritons at hyperbolic metasurfaces, called hyperbolic plasmons, have been experimentally observed just recently. However, the advantages of the hyperbolic plasmons, such as hybrid TE-TM polarization discussed below, are not yet fully revealed and analyzed. In this paper we focus on the numerical and experimental characterization of surface waves in the frequency range from 2 to 8 GHz supported by a hyperbolic metasurface composed of anisotropic metallic Jerusalem crosses printed on a thin dielectric substrate. We show different shapes of equal frequency contours, which correspond to a plethora of excitation and propagation regimes of surface waves. The principal novelty of this work consists in the experimental demonstration of the surface waves with a hybrid, i.e. mixed TE-TM, polarization. Surface waves with a hybrid polarization are the promising tool in a number of applications and phenomena including polarization converters, plasmonic sensors, plasmon steering over a surface, optical forces, spin-orbit photonics, and highlight the impact for the on-chip and planar networks.
△ Less
Submitted 9 October, 2018;
originally announced October 2018.
-
A Parametric Study of Radiative Dipole Body Array Coil for 7 Tesla MRI
Authors:
Anna A. Hurshkainen,
Bart Steensma,
Stanislav B. Glybovski,
Ingmar J. Voogt,
Irina V. Melchakova,
Pavel A. Belov,
Cornelis A. T. van den Berg,
Alexander J. E. Raaijmakers
Abstract:
In this contribution we present numerical and experimental results of a parametric quantitative study of radiative dipole antennas in a phased array configuration for efficient body magnetic resonance imaging at 7T via parallel transmission. For magnetic resonance imaging (MRI) at ultrahigh fields (7T and higher) dipole antennas are commonly used in phased arrays, particularly for body imaging tar…
▽ More
In this contribution we present numerical and experimental results of a parametric quantitative study of radiative dipole antennas in a phased array configuration for efficient body magnetic resonance imaging at 7T via parallel transmission. For magnetic resonance imaging (MRI) at ultrahigh fields (7T and higher) dipole antennas are commonly used in phased arrays, particularly for body imaging targets. This study reveals the effects of dipole positioning in the array (elevation of dipoles above the subject and inter-dipole spacing) on their mutual coupling, $B_1^{+}$ per $P_{acc}$ and $B_1^{+}$ per maximum local SAR efficiencies as well as the RF-shimming capability. The numerical and experimental results are obtained and compared for a homogeneous phantom as well as for a real human models confirmed by in-vivo experiments.
△ Less
Submitted 18 February, 2020; v1 submitted 6 October, 2017;
originally announced October 2017.
-
Element Decoupling of 7T Dipole Body Arrays by EBG Metasurface Structures: Experimental Verification
Authors:
Anna A. Hurshkainen,
Tatyana A. Derzhavskaya,
Stanislav B. Glybovski,
Ingmar J. Voogt,
Irina V. Melchakova,
Cornelis A. T. van den Berg,
Alexander J. E. Raaijmakers
Abstract:
Metasurfaces are artificial electromagnetic boundaries or interfaces usually implemented as two-dimensional periodic structures with subwavelength periodicity and engineered properties of constituent unit cells. The electromagnetic bandgap (EBG) effect in metasurfaces prevents all surface modes from propagating in a certain frequency band. While metasurfaces provide a number of important applicati…
▽ More
Metasurfaces are artificial electromagnetic boundaries or interfaces usually implemented as two-dimensional periodic structures with subwavelength periodicity and engineered properties of constituent unit cells. The electromagnetic bandgap (EBG) effect in metasurfaces prevents all surface modes from propagating in a certain frequency band. While metasurfaces provide a number of important applications in microwave antennas and antenna arrays, their features are also highly suitable for MRI applications. In this work we manufacture and experimentally study finite samples based on mushroom-type EBG metasurfaces and employ them for suppression of inter-element coupling in dipole transmit coil arrays for body imaging at 7T. We show experimentally that employment of the samples EBG leads to reduction of coupling between adjacent closely-spaced dipole antenna elements of a 7T transmit/receive body array, which reduces scattering losses in neighboring channels and thereby improves the B1+ efficiency. The setup consists of two fractionated dipole antennas previously designed by the authors for body imaging at 7 Tesla. These are placed on top of a body-mimicking phantom and equipped with the manufactured finite-size sample of the metasurface tuned to have EBG properties at the Larmor frequency of 298 MHz. To improve the detection range of the B1+ field distribution of the top elements, four additional elements were positioned along the bottom side of the phantom. Scattering matrix measurements show that coupling between the two top elements is indeed reduced while the measurements performed on a 7T MRI machine confirm the array's B1+ efficiency improvement due to reduced scattering losses. This study provides a tool for the decoupling of dipole antennas in ultrahigh field transmit arrays, possibly resulting in denser element placement and/or larger subject-element spacing.
△ Less
Submitted 20 January, 2016;
originally announced January 2016.