-
Temporal convolutional networks predict dynamic oxygen uptake response from wearable sensors across exercise intensities
Authors:
Robert Amelard,
Eric T Hedge,
Richard L Hughson
Abstract:
Oxygen consumption (VO$_2$) provides established clinical and physiological indicators of cardiorespiratory function and exercise capacity. However, VO$_2$ monitoring is largely limited to specialized laboratory settings, making its widespread monitoring elusive. Here, we investigate temporal prediction of VO$_2$ from wearable sensors during cycle ergometer exercise using a temporal convolutional…
▽ More
Oxygen consumption (VO$_2$) provides established clinical and physiological indicators of cardiorespiratory function and exercise capacity. However, VO$_2$ monitoring is largely limited to specialized laboratory settings, making its widespread monitoring elusive. Here, we investigate temporal prediction of VO$_2$ from wearable sensors during cycle ergometer exercise using a temporal convolutional network (TCN). Cardiorespiratory signals were acquired from a smart shirt with integrated textile sensors alongside ground-truth VO$_2$ from a metabolic system on twenty-two young healthy adults. Participants performed one ramp-incremental and three pseudorandom binary sequence exercise protocols to assess a range of VO$_2$ dynamics. A TCN model was developed using causal convolutions across an effective history length to model the time-dependent nature of VO$_2$. Optimal history length was determined through minimum validation loss across hyperparameter values. The best performing model encoded 218 s history length (TCN-VO$_2$ A), with 187 s, 97 s, and 76 s yielding less than 3% deviation from the optimal validation loss. TCN-VO$_2$ A showed strong prediction accuracy (mean, 95% CI) across all exercise intensities (-22 ml.min$^{-1}$, [-262, 218]), spanning transitions from low-moderate (-23 ml.min$^{-1}$, [-250, 204]), low-high (14 ml.min$^{-1}$, [-252, 280]), ventilatory threshold-high (-49 ml.min$^{-1}$, [-274, 176]), and maximal (-32 ml.min$^{-1}$, [-261, 197]) exercise. Second-by-second classification of physical activity across 16090 s of predicted VO$_2$ was able to discern between vigorous, moderate, and light activity with high accuracy (94.1%). This system enables quantitative aerobic activity monitoring in non-laboratory settings across a range of exercise intensities using wearable sensors for monitoring exercise prescription adherence and personal fitness.
△ Less
Submitted 13 October, 2021; v1 submitted 20 May, 2021;
originally announced May 2021.
-
Optical Hemodynamic Imaging of Jugular Venous Dynamics During Altered Central Venous Pressure
Authors:
Robert Amelard,
Andrew D Robertson,
Courtney A Patterson,
Hannah Heigold,
Essi Saarikoski,
Richard L Hughson
Abstract:
An optical imaging system is proposed for quantitatively assessing jugular venous response to altered central venous pressure. The proposed system assesses sub-surface optical absorption changes from jugular venous waveforms with a spatial calibration procedure to normalize incident tissue illumination. Widefield frames of the right lateral neck were captured and calibrated using a novel flexible…
▽ More
An optical imaging system is proposed for quantitatively assessing jugular venous response to altered central venous pressure. The proposed system assesses sub-surface optical absorption changes from jugular venous waveforms with a spatial calibration procedure to normalize incident tissue illumination. Widefield frames of the right lateral neck were captured and calibrated using a novel flexible surface calibration method. A hemodynamic optical model was derived to quantify jugular venous optical attenuation (JVA) signals, and generate a spatial jugular venous pulsatility map. JVA was assessed in three cardiovascular protocols that altered central venous pressure: acute central hypovolemia (lower body negative pressure), venous congestion (head-down tilt), and impaired cardiac filling (Valsalva maneuver). JVA waveforms exhibited biphasic wave properties consistent with jugular venous pulse dynamics when time-aligned with an electrocardiogram. JVA correlated strongly (median, interquartile range) with invasive central venous pressure during graded central hypovolemia (r=0.85, [0.72, 0.95]), graded venous congestion (r=0.94, [0.84, 0.99]), and impaired cardiac filling (r=0.94, [0.85, 0.99]). Reduced JVA during graded acute hypovolemia was strongly correlated with reductions in stroke volume (SV) (r=0.85, [0.76, 0.92]) from baseline (SV: 79$\pm$15 mL, JVA: 0.56$\pm$0.10 a.u.) to -40 mmHg suction (SV: 59$\pm$18 mL, JVA: 0.47$\pm$0.05 a.u.; p$<$0.01). The proposed non-contact optical imaging system demonstrated jugular venous dynamics consistent with invasive central venous monitoring during three protocols that altered central venous pressure. This system provides non-invasive monitoring of pressure-induced jugular venous dynamics in clinically relevant conditions where catheterization is traditionally required, enabling monitoring in non-surgical environments.
△ Less
Submitted 24 March, 2021; v1 submitted 22 July, 2020;
originally announced July 2020.
-
Monocular 3D Sway Tracking for Assessing Postural Instability in Cerebral Hypoperfusion During Quiet Standing
Authors:
Robert Amelard,
Kevin R Murray,
Eric T Hedge,
Taylor W Cleworth,
Mamiko Noguchi,
Andrew Laing,
Richard L Hughson
Abstract:
Postural instability is prevalent in aging and neurodegenerative disease, decreasing quality of life and independence. Quantitatively monitoring balance control is important for assessing treatment efficacy and rehabilitation progress. However, existing technologies for assessing postural sway are complex and expensive, limiting their widespread utility. Here, we propose a monocular imaging system…
▽ More
Postural instability is prevalent in aging and neurodegenerative disease, decreasing quality of life and independence. Quantitatively monitoring balance control is important for assessing treatment efficacy and rehabilitation progress. However, existing technologies for assessing postural sway are complex and expensive, limiting their widespread utility. Here, we propose a monocular imaging system capable of assessing sub-millimeter 3D sway dynamics during quiet standing. Two anatomical targets with known feature geometries were placed on the lumbar and shoulder. Upper and lower trunk 3D kinematic motion was automatically assessed from a set of 2D frames through geometric feature tracking and an inverse motion model. Sway was tracked in 3D and compared between control and hypoperfusion conditions in 14 healthy young adults. The proposed system demonstrated high agreement with a commercial motion capture system (error $1.5 \times 10^{-4}~\text{mm}$, [$-0.52$, $0.52$]). Between-condition differences in sway dynamics were observed in anterior-posterior sway during early and mid stance, and medial-lateral sway during mid stance commensurate with decreased cerebral perfusion, followed by recovered sway dynamics during late stance with cerebral perfusion recovery. This inexpensive single-camera system enables quantitative 3D sway monitoring for assessing neuromuscular balance control in weakly constrained environments.
△ Less
Submitted 5 November, 2019; v1 submitted 11 July, 2019;
originally announced July 2019.
-
Non-contact hemodynamic imaging reveals the jugular venous pulse waveform
Authors:
Robert Amelard,
Richard L Hughson,
Danielle K Greaves,
Kaylen J Pfisterer,
Jason Leung,
David A Clausi,
Alexander Wong
Abstract:
Cardiovascular monitoring is important to prevent diseases from progressing. The jugular venous pulse (JVP) waveform offers important clinical information about cardiac health, but is not routinely examined due to its invasive catheterisation procedure. Here, we demonstrate for the first time that the JVP can be consistently observed in a non-contact manner using a novel light-based photoplethysmo…
▽ More
Cardiovascular monitoring is important to prevent diseases from progressing. The jugular venous pulse (JVP) waveform offers important clinical information about cardiac health, but is not routinely examined due to its invasive catheterisation procedure. Here, we demonstrate for the first time that the JVP can be consistently observed in a non-contact manner using a novel light-based photoplethysmographic imaging system, coded hemodynamic imaging (CHI). While traditional monitoring methods measure the JVP at a single location, CHI's wide-field imaging capabilities were able to observe the jugular venous pulse's spatial flow profile for the first time. The important inflection points in the JVP were observed, meaning that cardiac abnormalities can be assessed through JVP distortions. CHI provides a new way to assess cardiac health through non-contact light-based JVP monitoring, and can be used in non-surgical environments for cardiac assessment.
△ Less
Submitted 21 April, 2016; v1 submitted 15 April, 2016;
originally announced April 2016.