-
Automatic Quantification of Serial PET/CT Images for Pediatric Hodgkin Lymphoma Patients Using a Longitudinally-Aware Segmentation Network
Authors:
Xin Tie,
Muheon Shin,
Changhee Lee,
Scott B. Perlman,
Zachary Huemann,
Amy J. Weisman,
Sharon M. Castellino,
Kara M. Kelly,
Kathleen M. McCarten,
Adina L. Alazraki,
Junjie Hu,
Steve Y. Cho,
Tyler J. Bradshaw
Abstract:
$\textbf{Purpose}$: Automatic quantification of longitudinal changes in PET scans for lymphoma patients has proven challenging, as residual disease in interim-therapy scans is often subtle and difficult to detect. Our goal was to develop a longitudinally-aware segmentation network (LAS-Net) that can quantify serial PET/CT images for pediatric Hodgkin lymphoma patients. $\textbf{Materials and Metho…
▽ More
$\textbf{Purpose}$: Automatic quantification of longitudinal changes in PET scans for lymphoma patients has proven challenging, as residual disease in interim-therapy scans is often subtle and difficult to detect. Our goal was to develop a longitudinally-aware segmentation network (LAS-Net) that can quantify serial PET/CT images for pediatric Hodgkin lymphoma patients. $\textbf{Materials and Methods}$: This retrospective study included baseline (PET1) and interim (PET2) PET/CT images from 297 patients enrolled in two Children's Oncology Group clinical trials (AHOD1331 and AHOD0831). LAS-Net incorporates longitudinal cross-attention, allowing relevant features from PET1 to inform the analysis of PET2. Model performance was evaluated using Dice coefficients for PET1 and detection F1 scores for PET2. Additionally, we extracted and compared quantitative PET metrics, including metabolic tumor volume (MTV) and total lesion glycolysis (TLG) in PET1, as well as qPET and $Δ$SUVmax in PET2, against physician measurements. We quantified their agreement using Spearman's $ρ$ correlations and employed bootstrap resampling for statistical analysis. $\textbf{Results}$: LAS-Net detected residual lymphoma in PET2 with an F1 score of 0.606 (precision/recall: 0.615/0.600), outperforming all comparator methods (P<0.01). For baseline segmentation, LAS-Net achieved a mean Dice score of 0.772. In PET quantification, LAS-Net's measurements of qPET, $Δ$SUVmax, MTV and TLG were strongly correlated with physician measurements, with Spearman's $ρ$ of 0.78, 0.80, 0.93 and 0.96, respectively. The performance remained high, with a slight decrease, in an external testing cohort. $\textbf{Conclusion}$: LAS-Net achieved high performance in quantifying PET metrics across serial scans, highlighting the value of longitudinal awareness in evaluating multi-time-point imaging datasets.
△ Less
Submitted 12 April, 2024;
originally announced April 2024.
-
Automatic Personalized Impression Generation for PET Reports Using Large Language Models
Authors:
Xin Tie,
Muheon Shin,
Ali Pirasteh,
Nevein Ibrahim,
Zachary Huemann,
Sharon M. Castellino,
Kara M. Kelly,
John Garrett,
Junjie Hu,
Steve Y. Cho,
Tyler J. Bradshaw
Abstract:
In this study, we aimed to determine if fine-tuned large language models (LLMs) can generate accurate, personalized impressions for whole-body PET reports. Twelve language models were trained on a corpus of PET reports using the teacher-forcing algorithm, with the report findings as input and the clinical impressions as reference. An extra input token encodes the reading physician's identity, allo…
▽ More
In this study, we aimed to determine if fine-tuned large language models (LLMs) can generate accurate, personalized impressions for whole-body PET reports. Twelve language models were trained on a corpus of PET reports using the teacher-forcing algorithm, with the report findings as input and the clinical impressions as reference. An extra input token encodes the reading physician's identity, allowing models to learn physician-specific reporting styles. Our corpus comprised 37,370 retrospective PET reports collected from our institution between 2010 and 2022. To identify the best LLM, 30 evaluation metrics were benchmarked against quality scores from two nuclear medicine (NM) physicians, with the most aligned metrics selecting the model for expert evaluation. In a subset of data, model-generated impressions and original clinical impressions were assessed by three NM physicians according to 6 quality dimensions (3-point scale) and an overall utility score (5-point scale). Each physician reviewed 12 of their own reports and 12 reports from other physicians. Bootstrap resampling was used for statistical analysis. Of all evaluation metrics, domain-adapted BARTScore and PEGASUSScore showed the highest Spearman's rank correlations (0.568 and 0.563) with physician preferences. Based on these metrics, the fine-tuned PEGASUS model was selected as the top LLM. When physicians reviewed PEGASUS-generated impressions in their own style, 89% were considered clinically acceptable, with a mean utility score of 4.08 out of 5. Physicians rated these personalized impressions as comparable in overall utility to the impressions dictated by other physicians (4.03, P=0.41). In conclusion, personalized impressions generated by PEGASUS were clinically useful, highlighting its potential to expedite PET reporting.
△ Less
Submitted 17 October, 2023; v1 submitted 18 September, 2023;
originally announced September 2023.
-
ConTEXTual Net: A Multimodal Vision-Language Model for Segmentation of Pneumothorax
Authors:
Zachary Huemann,
Xin Tie,
Junjie Hu,
Tyler J. Bradshaw
Abstract:
Radiology narrative reports often describe characteristics of a patient's disease, including its location, size, and shape. Motivated by the recent success of multimodal learning, we hypothesized that this descriptive text could guide medical image analysis algorithms. We proposed a novel vision-language model, ConTEXTual Net, for the task of pneumothorax segmentation on chest radiographs. ConTEXT…
▽ More
Radiology narrative reports often describe characteristics of a patient's disease, including its location, size, and shape. Motivated by the recent success of multimodal learning, we hypothesized that this descriptive text could guide medical image analysis algorithms. We proposed a novel vision-language model, ConTEXTual Net, for the task of pneumothorax segmentation on chest radiographs. ConTEXTual Net utilizes language features extracted from corresponding free-form radiology reports using a pre-trained language model. Cross-attention modules are designed to combine the intermediate output of each vision encoder layer and the text embeddings generated by the language model. ConTEXTual Net was trained on the CANDID-PTX dataset consisting of 3,196 positive cases of pneumothorax with segmentation annotations from 6 different physicians as well as clinical radiology reports. Using cross-validation, ConTEXTual Net achieved a Dice score of 0.716$\pm$0.016, which was similar to the degree of inter-reader variability (0.712$\pm$0.044) computed on a subset of the data. It outperformed both vision-only models (ResNet50 U-Net: 0.677$\pm$0.015 and GLoRIA: 0.686$\pm$0.014) and a competing vision-language model (LAVT: 0.706$\pm$0.009). Ablation studies confirmed that it was the text information that led to the performance gains. Additionally, we show that certain augmentation methods degraded ConTEXTual Net's segmentation performance by breaking the image-text concordance. We also evaluated the effects of using different language models and activation functions in the cross-attention module, highlighting the efficacy of our chosen architectural design.
△ Less
Submitted 15 September, 2023; v1 submitted 2 March, 2023;
originally announced March 2023.
-
Domain-adapted large language models for classifying nuclear medicine reports
Authors:
Zachary Huemann,
Changhee Lee,
Junjie Hu,
Steve Y. Cho,
Tyler Bradshaw
Abstract:
With the growing use of transformer-based language models in medicine, it is unclear how well these models generalize to nuclear medicine which has domain-specific vocabulary and unique reporting styles. In this study, we evaluated the value of domain adaptation in nuclear medicine by adapting language models for the purpose of 5-point Deauville score prediction based on clinical 18F-fluorodeoxygl…
▽ More
With the growing use of transformer-based language models in medicine, it is unclear how well these models generalize to nuclear medicine which has domain-specific vocabulary and unique reporting styles. In this study, we evaluated the value of domain adaptation in nuclear medicine by adapting language models for the purpose of 5-point Deauville score prediction based on clinical 18F-fluorodeoxyglucose (FDG) PET/CT reports. We retrospectively retrieved 4542 text reports and 1664 images for FDG PET/CT lymphoma exams from 2008-2018 in our clinical imaging database. Deauville scores were removed from the reports and then the remaining text in the reports was used as the model input. Multiple general-purpose transformer language models were used to classify the reports into Deauville scores 1-5. We then adapted the models to the nuclear medicine domain using masked language modeling and assessed its impact on classification performance. The language models were compared against vision models, a multimodal vision language model, and a nuclear medicine physician with seven-fold Monte Carlo cross validation, reported are the mean and standard deviations. Domain adaption improved all language models. For example, BERT improved from 61.3% five-class accuracy to 65.7% following domain adaptation. The best performing model (domain-adapted RoBERTa) achieved a five-class accuracy of 77.4%, which was better than the physician's performance (66%), the best vision model's performance (48.1), and was similar to the multimodal model's performance (77.2). Domain adaptation improved the performance of large language models in interpreting nuclear medicine text reports.
△ Less
Submitted 1 March, 2023;
originally announced March 2023.