Designing large pixelated CdTe detection planes for hard X-ray transients detection
Authors:
K. Lacombe,
C. Amoros,
J. -L. Atteia,
A. Bajat,
L. Bouchet,
J. -P. Dezalay,
P. Guillemot,
B. Houret,
F. Lebrun,
S. Mate,
R. Pons,
H. Triou,
V. Waegebaert
Abstract:
We discuss the need for very large detection planes for the detection of hard X-ray transients in the multi-messenger era that started with the quasi-simultaneous detection of GRB~170817A by \textit{Fermi}/GBM and \textit{INTEGRAL}/SPI on one hand and the gravitational waves event GW 170817, detected by the LVC collaboration, on the other hand. Then, we present a brief survey of current and future…
▽ More
We discuss the need for very large detection planes for the detection of hard X-ray transients in the multi-messenger era that started with the quasi-simultaneous detection of GRB~170817A by \textit{Fermi}/GBM and \textit{INTEGRAL}/SPI on one hand and the gravitational waves event GW 170817, detected by the LVC collaboration, on the other hand. Then, we present a brief survey of current and future instruments and their expected sensitivity, pointing the fact that the gain in the number of GRBs is achieved by future projects thanks to their larger field of view rather than to their larger effective area. Based on our experience with \textit{SVOM}/ECLAIRs, we then address various problems associated with the realization of very large detection planes (\mbox{$\ge 1 \mathrm m^{2}$}), and we demonstrate that CdTe detectors are well suited for this task. We conclude with a discussion of some key parameters that must be taken into account in the realization of instruments based on these detectors. We hope that this paper will motivate the elaboration of detailed proposals of large area wide-field hard X-ray monitors that will be crucially needed in the next decade.
△ Less
Submitted 19 September, 2019;
originally announced September 2019.
The X-/Gamma-ray camera ECLAIRs for the Gammay-ray burst mission SVOM
Authors:
O. Godet,
G. Nasser,
J. -L. Atteia,
B. Cordier,
P. Mandrou,
D. Barret,
H. Triou,
R. Pons,
C. Amoros,
S. Bordon,
O. Gevin,
F. Gonzalez,
D. Götz,
A. Gros,
B. Houret,
C. Lachaud,
K. Lacombe,
W. Marty,
K. Mercier,
D. Rambaud,
P. Ramon,
G. Rouaix,
S. Schanne,
V Waegebaert
Abstract:
We present ECLAIRs, the Gamma-ray burst (GRB) trigger camera to fly on-board the Chinese-French mission SVOM. ECLAIRs is a wide-field ($\sim 2$\,sr) coded mask camera with a mask transparency of 40\% and a 1024 $\mathrm{cm}^2$ detection plane coupled to a data processing unit, so-called UGTS, which is in charge of locating GRBs in near real time thanks to image and rate triggers. We present the in…
▽ More
We present ECLAIRs, the Gamma-ray burst (GRB) trigger camera to fly on-board the Chinese-French mission SVOM. ECLAIRs is a wide-field ($\sim 2$\,sr) coded mask camera with a mask transparency of 40\% and a 1024 $\mathrm{cm}^2$ detection plane coupled to a data processing unit, so-called UGTS, which is in charge of locating GRBs in near real time thanks to image and rate triggers. We present the instrument science requirements and how the design of ECLAIRs has been optimized to increase its sensitivity to high-redshift GRBs and low-luminosity GRBs in the local Universe, by having a low-energy threshold of 4 keV. The total spectral coverage ranges from 4 to 150 keV. ECLAIRs is expected to detect $\sim 200$ GRBs of all types during the nominal 3 year mission lifetime.
To reach a 4 keV low-energy threshold, the ECLAIRs detection plane is paved with 6400 $4\times 4~\mathrm{mm}^2$ and 1 mm-thick Schottky CdTe detectors. The detectors are grouped by 32, in 8x4 matrices read by a low-noise ASIC, forming elementary modules called XRDPIX. In this paper, we also present our current efforts to investigate the performance of these modules with their front-end electronics when illuminated by charged particles and/or photons using radioactive sources. All measurements are made in different instrument configurations in vacuum and with a nominal in-flight detector temperature of $-20^\circ$C. This work will enable us to choose the in-flight configuration that will make the best compromise between the science performance and the in-flight operability of ECLAIRs. We will show some highlights of this work.
△ Less
Submitted 30 June, 2014;
originally announced June 2014.