Dynamic Solar Hosting Capacity Calculations in Microgrids
Authors:
Z. S. Hosseini,
A. Khodaei,
E. A. Paaso,
M. S. Hossan,
D. Lelic
Abstract:
Microgrids, as small-scale islandable power systems, are considered as viable promotors of renewable energy resources. In particular, microgrids can efficiently integrate solar photovoltaic (PV) as the deployment of this customer-deployed technology is growing in distribution grids. However, there is a limit on how much PV can be hosted by a microgrid. High penetration of PVs can potentially put t…
▽ More
Microgrids, as small-scale islandable power systems, are considered as viable promotors of renewable energy resources. In particular, microgrids can efficiently integrate solar photovoltaic (PV) as the deployment of this customer-deployed technology is growing in distribution grids. However, there is a limit on how much PV can be hosted by a microgrid. High penetration of PVs can potentially put the microgrid at operational risks including but not limited to over and under voltages, excessive line losses, overloading of transformers and feeders, and protection failure. To avoid such potential negative impacts, the concept of hosting capacity is introduced and used. The hosting capacity is defined as the total capacity of DERs that can be integrated into a given feeder/microgrid without exceeding operational restrictions and/or requiring system upgrades. Hosting capacity studies are primarily done based on steadystate analyses. However, in case of microgrids and when transitioning between grid-connected and islanded modes, dynamic operation becomes more restrictive than steady-state operation and thus is worthy of detailed investigation to provide a better understanding of the amount of DER that the microgrid can host. This paper examines this problem and provides extensive simulations on a practical test system to show its importance and merits.
△ Less
Submitted 26 September, 2018;
originally announced September 2018.
-
Battery Swap** Station as an Energy Storage for Capturing Distribution-Integrated Solar Variability
Authors:
Zohreh S. Hosseini,
Mohsen Mahoor,
Amin Khodaei
Abstract:
Managing the inherent variability of solar generation is a critical challenge for utility grid operators, particularly as the distribution grid-integrated solar generation is making fast inroads in power systems. This paper proposes to leverage Battery Swap** Station (BSS) as an energy storage for mitigating solar photovoltaic (PV) output fluctuations. Using mixed-integer programming, a model fo…
▽ More
Managing the inherent variability of solar generation is a critical challenge for utility grid operators, particularly as the distribution grid-integrated solar generation is making fast inroads in power systems. This paper proposes to leverage Battery Swap** Station (BSS) as an energy storage for mitigating solar photovoltaic (PV) output fluctuations. Using mixed-integer programming, a model for the BSS optimal scheduling is proposed to capture solar generation variability. The proposed model aims at minimizing the BSS total operation cost, which represents the accumulated cost of exchanging power with the utility grid. The model is subject to four sets of constraints associated with the utility grid, the BSS system, individual batteries, and solar variability. Numerical simulations on a test BSS demonstrate the effectiveness of the proposed model and show its viability in hel** the utility grids host a higher penetration of solar generation.
△ Less
Submitted 18 July, 2018;
originally announced July 2018.
-
Electric Vehicle Battery Swap** Station
Authors:
Mohsen Mahoor,
Zohreh S. Hosseini,
Amin Khodaei,
D. Kushner
Abstract:
Providing adequate charging infrastructure plays a momentous role in rapid proliferation of Electric Vehicles (EVs). Easy access to such infrastructure would remove various obstacles regarding limited EV mobility range. A Battery Swap** Station (BSS) is an effective approach in supplying power to the EVs, while mitigating long waiting times in a Battery Charging Station (BCS). In contrast with t…
▽ More
Providing adequate charging infrastructure plays a momentous role in rapid proliferation of Electric Vehicles (EVs). Easy access to such infrastructure would remove various obstacles regarding limited EV mobility range. A Battery Swap** Station (BSS) is an effective approach in supplying power to the EVs, while mitigating long waiting times in a Battery Charging Station (BCS). In contrast with the BCS, the BSS charges the batteries in advance and prepares them to be swapped in a considerably short time. Considering that these stations can serve as an intermediate entity between the EV owners and the power system, they can potentially provide unique benefits to the power system. This paper investigates the advantages of building the BSS from various perspectives. Accordingly, a model for the scheduling of battery charging from the station owner perspective is proposed. An illustrative example is provided to show how the proposed model would help BSS owners in managing their assets through scheduling battery charging time.
△ Less
Submitted 2 October, 2017;
originally announced October 2017.
-
Leveraging Sensory Data in Estimating Transformer Lifetime
Authors:
Mohsen Mahoor,
Alireza Majzoobi,
Zohreh S. Hosseini,
Amin Khodaei
Abstract:
Transformer lifetime assessments plays a vital role in reliable operation of power systems. In this paper, leveraging sensory data, an approach in estimating transformer lifetime is presented. The winding hottest-spot temperature, which is the pivotal driver that impacts transformer aging, is measured hourly via a temperature sensor, then transformer loss of life is calculated based on the IEEE St…
▽ More
Transformer lifetime assessments plays a vital role in reliable operation of power systems. In this paper, leveraging sensory data, an approach in estimating transformer lifetime is presented. The winding hottest-spot temperature, which is the pivotal driver that impacts transformer aging, is measured hourly via a temperature sensor, then transformer loss of life is calculated based on the IEEE Std. C57.91-2011. A Cumulative Moving Average (CMA) model is subsequently applied to the data stream of the transformer loss of life to provide hourly estimates until convergence. Numerical examples demonstrate the effectiveness of the proposed approach for the transformer lifetime estimation, and explores its efficiency and practical merits.
△ Less
Submitted 19 June, 2017;
originally announced June 2017.