Low-dose, high-resolution CT of infant-sized lungs via propagation-based phase contrast
Authors:
James A. Pollock,
Kaye Morgan,
Linda C. P. Croton,
Emily J. Pryor,
Kelly J. Crossley,
Christopher J. Hall,
Daniel Hausermann,
Anton Maksimenko,
Stuart B. Hooper,
Marcus J. Kitchen
Abstract:
Many lung diseases and abnormalities require detailed visualisation of the lungs for accurate diagnosis and treatment. High-resolution computed tomography (CT) is the gold-standard technique for non-invasive lung disease detection, but it presents a risk to the patient through the relatively high ionising radiation dose required. Utilising the X-ray phase information may allow improvements in imag…
▽ More
Many lung diseases and abnormalities require detailed visualisation of the lungs for accurate diagnosis and treatment. High-resolution computed tomography (CT) is the gold-standard technique for non-invasive lung disease detection, but it presents a risk to the patient through the relatively high ionising radiation dose required. Utilising the X-ray phase information may allow improvements in image resolution at equal or lower radiation levels than current clinical imaging. Propagation-based phase-contrast imaging requires minimal adaption of existing medical systems, and is well suited to lung imaging due to the strong phase gradients introduced by the lung-air material interface. Herein, propagation-based phase contrast CT is demonstrated for large animals, namely lambs, as a model for paediatric patients, using monochromatic radiation and a photon-counting detector at the Imaging and Medical Beamline of the Australian Synchrotron. Image quality, normalised against radiation dose, was optimised as a function of the beam energy and propagation distance, with the optimal conditions used to test the available image quality at very low radiation dose. Noise-limited spatial resolution was measured using Fourier ring correlation, and dosimetry was performed through Monte Carlo simulation calibrated against air kerma. The resulting CT images demonstrate superior resolution to existing high-resolution CT systems, pushing dose to the quantum limit to comply with current Australian guidelines for infant chest CT exposure (<2.5 mSv effective dose). Constituent raw projections are shown to have significant proportions of pixels with zero photon counts that would create severe information loss in conventional CT, which was prevented through phase retrieval.
△ Less
Submitted 8 July, 2024;
originally announced July 2024.
-
Robust propagation-based phase retrieval for CT in proximity to highly attenuating objects
Authors:
J. A. Pollock,
L. C. P. Croton,
K. S. Morgan,
K. J. Crossley,
M. J. Wallace,
G. A. Buckley,
S. B. Hooper,
M. J. Kitchen
Abstract:
X-ray imaging is a fast, precise and non-invasive method of imaging which, combined with computed tomography, provides detailed 3D rendering of samples. Incorporating propagation-based phase contrast can vastly improve data quality for weakly attenuating samples via material-specific phase retrieval filters, allowing radiation exposure to be reduced. However, applying phase retrieval to multi-mate…
▽ More
X-ray imaging is a fast, precise and non-invasive method of imaging which, combined with computed tomography, provides detailed 3D rendering of samples. Incorporating propagation-based phase contrast can vastly improve data quality for weakly attenuating samples via material-specific phase retrieval filters, allowing radiation exposure to be reduced. However, applying phase retrieval to multi-material phantoms complicates analysis by requiring a choice of which material boundary to tune the phase retrieval. Filtering for the boundary with strongest phase contrast increases noise suppression, but with the detriment of over-blurring other interfaces, potentially obscuring small or neighbouring features and removing quantitative sample information. Additionally, regions bounded by more than one material type inherently cannot be conventionally filtered to reconstruct the whole boundary. As remedy, we present a computationally-efficient, non-iterative nor AI-mediated method for applying strong phase retrieval, whilst preserving sharp boundaries for all materials within the sample. This technique was tested on phase contrast images of a rabbit kitten brain encased by the surrounding dense skull. Using 24 keV synchrotron radiation with a 5 m propagation distance, our technique provided a 6.9-fold improvement in the signal-to-noise ratio (SNR) of brain tissue compared to the standard phase retrieval procedure, without over-smoothing the images. Simultaneous quantification of edge resolution and SNR gain was performed with an aluminium-water phantom imaged using a microfocus X-ray tube at mean energy 19.58 keV and 0.576 m effective propagation distance. Our method provided a 4.2-fold SNR boost whilst preserving the boundary resolution at 54 $\pm$ 1 $μ$m, compared to 108 $\pm$ 2 $μ$m in conventional phase retrieval.
△ Less
Submitted 29 January, 2023;
originally announced January 2023.
-
Accurate measures of regional lung air volumes from chest X-rays of small animals
Authors:
D. W. O'Connell,
K. S. Morgan,
G. Ruben,
L. C. P. Croton,
J. A. Pollock,
M. K. Croughan,
E. V. McGillick,
M. J. Wallace,
K. J. Crossley,
E. J. Pryor,
R. A. Lewis,
S. B. Hooper,
M. J. Kitchen
Abstract:
We present a robust technique for calculating regional volume changes within the lung from X-ray radiograph sequences captured during ventilation, without the use of computed tomography (CT). This technique is based on the change in transmitted X-ray intensity that occurs for each lung region as air displaces the attenuating lung tissue. Lung air volumes calculated from X-ray intensity changes sho…
▽ More
We present a robust technique for calculating regional volume changes within the lung from X-ray radiograph sequences captured during ventilation, without the use of computed tomography (CT). This technique is based on the change in transmitted X-ray intensity that occurs for each lung region as air displaces the attenuating lung tissue. Lung air volumes calculated from X-ray intensity changes showed a strong correlation ($R^2$=0.98) against the true volumes, measured from high-resolution CT. This correlation enables us to accurately convert projected intensity data into relative changes in lung air volume. We have applied this technique to measure changes in regional lung volumes from X-ray image sequences of mechanically ventilated, recently-deceased newborn rabbits, without the use of CT. This method is suitable for biomedical research studies and shows potential for clinical application.
△ Less
Submitted 7 April, 2022; v1 submitted 16 February, 2022;
originally announced February 2022.
-
Material Decomposition using Spectral Propagation-based Phase Contrast X-ray Imaging
Authors:
Florian Schaff,
Kaye S. Morgan,
James A. Pollock,
Linda C. P. Croton,
Stuart B. Hooper,
Marcus J. Kitchen
Abstract:
Material decomposition in X-ray imaging uses the energy-dependence of attenuation to virtually decompose an object into specific constituent materials. X-ray phase contrast imaging is a develo** technique that can enhance image contrast seen from weakly attenuating objects. In this paper, we combine spectral phase contrast imaging with material decomposition to both better visualise weakly atten…
▽ More
Material decomposition in X-ray imaging uses the energy-dependence of attenuation to virtually decompose an object into specific constituent materials. X-ray phase contrast imaging is a develo** technique that can enhance image contrast seen from weakly attenuating objects. In this paper, we combine spectral phase contrast imaging with material decomposition to both better visualise weakly attenuating features and separate them from overlying objects in radiography. We derive an algorithm that performs both tasks simultaneously and verify it against numerical simulations and experimental measurements of ideal two-component samples composed of pure aluminium and poly(methyl methacrylate). Additionally, we showcase first imaging results of a rabbit kitten's lung. The attenuation signal of a thorax, in particular, is dominated by the strongly attenuating bones of the ribcage, which combined with the weak soft tissue signal make it difficult to visualise the fine anatomical structures across the whole lung. In all cases, clean material decomposition was achieved, without residual phase contrast effects, from which we generate an un-obstructed image of the lung, free of bones. Spectral propagation-based phase contrast imaging has the potential to be a valuable tool, not only in future lung research, but also in other systems for which phase contrast imaging in combination with material decomposition proves to be advantageous.
△ Less
Submitted 9 October, 2019;
originally announced October 2019.
-
In situ phase contrast X-ray brain CT
Authors:
Linda C. P. Croton,
Kaye S. Morgan,
David M. Paganin,
Lauren T. Kerr,
Megan J. Wallace,
Kelly J. Crossley,
Suzanne L. Miller,
Naoto Yagi,
Kentaro Uesugi,
Stuart B. Hooper,
Marcus J. Kitchen
Abstract:
Phase contrast X-ray imaging (PCXI) is an emerging imaging modality that has the potential to greatly improve radiography for medical imaging and materials analysis. PCXI makes it possible to visualise soft-tissue structures that are otherwise unresolved with conventional CT by rendering phase gradients in the X-ray wavefield visible. This can improve the contrast resolution of soft tissues struct…
▽ More
Phase contrast X-ray imaging (PCXI) is an emerging imaging modality that has the potential to greatly improve radiography for medical imaging and materials analysis. PCXI makes it possible to visualise soft-tissue structures that are otherwise unresolved with conventional CT by rendering phase gradients in the X-ray wavefield visible. This can improve the contrast resolution of soft tissues structures, like the lungs and brain, by orders of magnitude. Phase retrieval suppresses noise, revealing weakly-attenuating soft tissue structures, however it does not remove the artefacts from the highly attenuating bone of the skull and from imperfections in the imaging system that can obscure those structures. The primary causes of these artefacts are investigated and a simple method to visualise the features they obstruct is proposed, which can easily be implemented for preclinical animal studies. We show that phase contrast X-ray CT (PCXI-CT) can resolve the soft tissues of the brain in situ without a need for contrast agents at a dose $\sim$400 times lower than would be required by standard absorption contrast CT. We generalise a well-known phase retrieval algorithm for multiple-material samples specifically for CT, validate its use for brain CT, and demonstrate its high stability in the presence of noise.
△ Less
Submitted 24 January, 2018;
originally announced January 2018.
-
CT dose reduction factors in the thousands using X-ray phase contrast
Authors:
Marcus J. Kitchen,
Genevieve A. Buckley,
Timur E. Gureyev,
Megan J. Wallace,
Nico Andres-Thio,
Kentaro Uesugi,
Naoto Yagi,
Stuart B. Hooper,
.
Abstract:
Phase-contrast X-ray imaging can improve the visibility of weakly absorbing objects (e.g. soft tissues) by an order of magnitude or more compared to conventional radiographs. Previously, it has been shown that combining phase retrieval with computed tomography (CT) can increase the signal-to-noise ratio (SNR) by up to two orders of magnitude over conventional CT at the same radiation dose, without…
▽ More
Phase-contrast X-ray imaging can improve the visibility of weakly absorbing objects (e.g. soft tissues) by an order of magnitude or more compared to conventional radiographs. Previously, it has been shown that combining phase retrieval with computed tomography (CT) can increase the signal-to-noise ratio (SNR) by up to two orders of magnitude over conventional CT at the same radiation dose, without loss of image quality. Our experiments reveal that as radiation dose decreases, the relative improvement in SNR increases. We discovered this enhancement can be traded for a reduction in dose greater than the square of the gain in SNR. Upon reducing the dose 300 fold, the phase-retrieved SNR was still almost 10 times larger than the absorption contrast data. This reveals the potential for dose reduction factors in the tens of thousands without loss in image quality, which would have a profound impact on medical and industrial imaging applications.
△ Less
Submitted 11 April, 2017;
originally announced April 2017.