The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase
Authors:
Didier Barret,
Vincent Albouys,
Jan-Willem den Herder,
Luigi Piro,
Massimo Cappi,
Juhani Huovelin,
Richard Kelley,
J. Miguel Mas-Hesse,
Stéphane Paltani,
Gregor Rauw,
Agata Rozanska,
Jiri Svoboda,
Joern Wilms,
Noriko Yamasaki,
Marc Audard,
Simon Bandler,
Marco Barbera,
Xavier Barcons,
Enrico Bozzo,
Maria Teresa Ceballos,
Ivan Charles,
Elisa Costantini,
Thomas Dauser,
Anne Decourchelle,
Lionel Duband
, et al. (274 additional authors not shown)
Abstract:
The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide sp…
▽ More
The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over an hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR, browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters. Finally we briefly discuss on the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, and touch on communication and outreach activities, the consortium organisation, and finally on the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. Thanks to the studies conducted so far on X-IFU, it is expected that along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained. (abridged).
△ Less
Submitted 28 November, 2022; v1 submitted 30 August, 2022;
originally announced August 2022.
-
Susceptibility study of TES micro-calorimeters for X-ray spectroscopy under FDM readout
Authors:
Davide Vaccaro,
Hiroki Akamatsu,
Luciano Gottardi,
Jan van der Kuur,
Emanuele Taralli,
Martin de Wit,
Marcel P. Bruijn,
Roland den Hartog,
Mikko Kiviranta,
Anton J. van der Linden,
Kenichiro Nagayoshi,
Kevin Ravensberg,
Marcel L. Ridder,
Sven Visser,
Brian D. Jackson,
Jian-Rong Gao,
Ruud W. M. Hoogeveen,
Jan-Willem A. den Herder
Abstract:
We present a characterization of the sensitivity of TES X-ray micro-calorimeters to environmental conditions under frequency-domain multiplexing (FDM) readout. In the FDM scheme, each TES in a readout chain is in series with a LC band-pass filter and AC biased with an independent carrier at MHz range. Using TES arrays, cold readout circuitry and warm electronics fabricated at SRON and SQUIDs produ…
▽ More
We present a characterization of the sensitivity of TES X-ray micro-calorimeters to environmental conditions under frequency-domain multiplexing (FDM) readout. In the FDM scheme, each TES in a readout chain is in series with a LC band-pass filter and AC biased with an independent carrier at MHz range. Using TES arrays, cold readout circuitry and warm electronics fabricated at SRON and SQUIDs produced at VTT Finland, we characterize the sensitivity of the detectors to bias voltage, bath temperature and magnetic field. We compare our results with the requirements for the Athena X-IFU instrument, showing the compliance of the measured sensitivities. We find in particular that FDM is intrinsically insensitive to the magnetic field because of TES design and AC readout.
△ Less
Submitted 23 August, 2022;
originally announced August 2022.
-
ATHENA X-IFU Demonstration Model: First joint operation of the main TES Array and its Cryogenic AntiCoincidence Detector (CryoAC)
Authors:
M. D'Andrea,
K. Ravensberg,
A. Argan,
D. Brienza,
S. Lotti,
C. Macculi,
G. Minervini,
L. Piro,
G. Torrioli,
F. Chiarello,
L. Ferrari Barusso,
M. Biasotti,
G. Gallucci,
F. Gatti,
M. Rigano,
H. Akamatsu,
J. Dercksen,
L. Gottardi,
F. de Groote,
R. den Hartog,
J. -W. den Herder,
R. Hoogeveen,
B. Jackson,
A. McCalden,
S. Rosman
, et al. (6 additional authors not shown)
Abstract:
The X-IFU is the cryogenic spectrometer onboard the future ATHENA X-ray observatory. It is based on a large array of TES microcalorimeters, which works in combination with a Cryogenic AntiCoincidence detector (CryoAC). This is necessary to reduce the particle background level thus enabling part of the mission science goals. Here we present the first joint test of X-IFU TES array and CryoAC Demonst…
▽ More
The X-IFU is the cryogenic spectrometer onboard the future ATHENA X-ray observatory. It is based on a large array of TES microcalorimeters, which works in combination with a Cryogenic AntiCoincidence detector (CryoAC). This is necessary to reduce the particle background level thus enabling part of the mission science goals. Here we present the first joint test of X-IFU TES array and CryoAC Demonstration Models, performed in a FDM setup. We show that it is possible to operate properly both detectors, and we provide a preliminary demonstration of the anti-coincidence capability of the system achieved by the simultaneous detection of cosmic muons.
△ Less
Submitted 30 June, 2022;
originally announced June 2022.
-
Thermal crosstalk of X-ray transition-edge sensor micro-calorimeters under frequency domain multiplexing readout
Authors:
Davide Vaccaro,
Hiroki Akamatsu,
Marcel P. Bruijn,
Luciano Gottardi,
Roland den Hartog,
Jan van der Kuur,
A. J. van der Linden,
Kenichiro Nagayoshi,
Kevin Ravensberg,
Marcel L. Ridder,
Emanuele Taralli,
Martin de Wit,
Jian-Rong Gao,
Ruud W. M. Hoogeveen,
Jan-Willem A. den Herder
Abstract:
We have measured and characterized the thermal crosstalk in two different arrays of transition-edge sensor (TES) X-ray micro-calorimeters with frequency-domain multiplexing (FDM) readout. The TES arrays are fabricated at SRON and are a 8$\times$8 and a 32$\times$32 "kilo-pixel" uniform array. The amount of crosstalk is evaluated as the ratio between the averaged crosstalk signal and the X-ray puls…
▽ More
We have measured and characterized the thermal crosstalk in two different arrays of transition-edge sensor (TES) X-ray micro-calorimeters with frequency-domain multiplexing (FDM) readout. The TES arrays are fabricated at SRON and are a 8$\times$8 and a 32$\times$32 "kilo-pixel" uniform array. The amount of crosstalk is evaluated as the ratio between the averaged crosstalk signal and the X-ray pulse amplitudes. The crosstalk ratios (CR) for our detectors are compliant with the requirements for future X-ray space missions, such as Athena X-IFU (CR$< 10^{-3}$ for first-neighbour pixels): we measured a nearest-neighbour thermal crosstalk ratio at a level of $10^{-4}$, with a highest crosstalk ratio of $4\times 10^{-4}$ for the kilo-pixel array (worst case, center of array) and $1\times 10^{-4}$ for the 8$\times$8 array, with a margin of improvement achievable by optimizing the Cu metallization and the width of the Si supporting structures (muntins) in the backside of the TES array chip. Based on the measured crosstalk ratios, we have estimated the impact on the spectral resolution by means of noise equivalent power (NEP) considerations and a Monte Carlo simulation, finding an average degradation in quadrature of less than 40~meV, compliant with the < 0.2~eV requirement for Athena X-IFU.
△ Less
Submitted 24 November, 2021;
originally announced November 2021.
-
Demonstration of MHz frequency domain multiplexing readout of 37 transition edge sensors for high-resolution x-ray imaging spectrometers
Authors:
H. Akamatsu,
D. Vaccaro,
L. Gottardi,
J. van der Kuur,
C. P. de Vries,
M. Kiviranta,
K. Ravensberg,
M. D'Andrea,
E. Taralli,
M. de Wit,
M. P. Bruijn,
P. van der Hulst,
R. H. den Hartog,
B-J. van Leeuwen,
A. J. van der Linden,
A. J McCalden,
K. Nagayoshi,
A. C. T. Nieuwenhuizen,
M. L. Ridder,
S. Visser,
P. van Winden,
J. R. Gao,
R. W. M. Hoogeveen,
B. D. Jackson,
J-W. A. den Herder
Abstract:
We report on the development and demonstration of a MHz frequency domain multiplexing (FDM) technology to read out arrays of cryogenic transition edge sensor (TES) X-ray microcalorimeters. In our FDM scheme, TESs are AC-biased at different resonant frequencies in the low MHz range through an array of high-$Q$ LC resonators. The current signals of all TESs are summed at superconducting quantum inte…
▽ More
We report on the development and demonstration of a MHz frequency domain multiplexing (FDM) technology to read out arrays of cryogenic transition edge sensor (TES) X-ray microcalorimeters. In our FDM scheme, TESs are AC-biased at different resonant frequencies in the low MHz range through an array of high-$Q$ LC resonators. The current signals of all TESs are summed at superconducting quantum interference devices (SQUIDs). We have demonstrated multiplexing for a readout of 31 pixels using room temperature electronics, high-$Q$ LC filters and TES arrays developed at SRON, and SQUID arrays from VTT. We repeated this on a second setup with 37 pixels. The summed X-ray spectral resolutions $@$ 5.9 keV are $ΔE_{\rm 31 pix ~MUX}=2.14\pm0.03$ eV and $ΔE_{\rm 37 pix ~MUX}=2.23\pm0.03$ eV. The demonstrated results are comparable with other multiplexing approaches. There is potential to further improve the spectral resolution and to increase the number of multiplexed TESs, and to open up applications for TES X-ray microcalorimeters.
△ Less
Submitted 2 November, 2021;
originally announced November 2021.
-
Impact of the absorber coupling design for Transition Edge Sensor X-ray Calorimeters
Authors:
M. de Wit,
L. Gottardi,
E. Taralli,
K. Nagayoshi,
M. L. Ridder,
H. Akamatsu,
M. P. Bruijn,
R. W. M. Hoogeveen,
J. van der Kuur,
K. Ravensberg,
D. Vaccaro,
J-R. Gao,
J-W. A. den Herder
Abstract:
Transition Edge Sensors (TESs) are the selected technology for future spaceborne X-ray observatories, such as Athena, Lynx, and HUBS. These missions demand thousands of pixels to be operated simultaneously with high energy-resolving power. To reach these demanding requirements, every aspect of the TES design has to be optimized. Here we present the experimental results of tests on different device…
▽ More
Transition Edge Sensors (TESs) are the selected technology for future spaceborne X-ray observatories, such as Athena, Lynx, and HUBS. These missions demand thousands of pixels to be operated simultaneously with high energy-resolving power. To reach these demanding requirements, every aspect of the TES design has to be optimized. Here we present the experimental results of tests on different devices where the coupling between the x-ray absorber and the TES sensor is varied. In particular, we look at the effects of the diameter of the coupling stems and the distance between the stems and the TES bilayer. Based on measurements of the AC complex impedance and noise, we observe a reduction in the excess noise as the spacing between the absorber stem and the bilayer is decreased. We identify the origin of this excess noise to be internal thermal fluctuation noise between the absorber stem and the bilayer. Additionally, we see an impact of the coupling on the superconducting transition in the appearance of kinks. Our observations show that these unwanted structures in the transition shape can be avoided with careful design of the coupling geometry. Also the stem diameter appears to have a significant impact on the smoothness of the TES transition. This observation is still poorly understood, but is of great importance for both AC and DC biased TESs.
△ Less
Submitted 20 July, 2021;
originally announced July 2021.
-
TiAu TES 32$\times$32 pixel array: uniformity, thermal crosstalk and performance at different X-ray energies
Authors:
E. Taralli,
M. D'Andrea,
L. Gottardi,
K. Nagayoshi,
M. Ridder,
S. Visser,
M. de Wit,
D. Vaccaro,
H. Akamatsu,
K. Ravensberg,
R. Hoogeveen,
M. Bruijn,
J. R. Gao
Abstract:
Large format arrays of transition edge sensor (TES) are crucial for the next generation of X-ray space observatories. Such arrays are required to achieve an energy resolution of $\mathrmΔE<$3 eV full-width-half-maximum (FWHM) in the soft X-ray energy range. We are currently develo** X-ray microcalorimeter arrays as a backup option for the X-IFU instrument on board of ATHENA space telescope, led…
▽ More
Large format arrays of transition edge sensor (TES) are crucial for the next generation of X-ray space observatories. Such arrays are required to achieve an energy resolution of $\mathrmΔE<$3 eV full-width-half-maximum (FWHM) in the soft X-ray energy range. We are currently develo** X-ray microcalorimeter arrays as a backup option for the X-IFU instrument on board of ATHENA space telescope, led by ESA and foreseen to be launched in 2031. In this contribution, we report on the development and the characterization of a uniform 32$\times$32 pixel array with (length$\times $width) 140$\times$30 $μ$m$^2$ TiAu TESs, which have \textcolor{black}{a 2.3 $μ$m} thick Au absorber for X-ray photons. The pixels have a typical normal resistance $R_\mathrm{n}$ = 121 m$Ω$ and a critical temperature $T_\mathrm{c}\sim$ 90 mK. We performed extensive measurements on 60 pixels out of the array in order to show the uniformity of the array. We obtained an energy resolutions between 2.4 and 2.6 eV (FWHM) at 5.9 keV, measured in a single-pixel mode at AC bias frequencies ranging from 1 to 5 MHz, with a frequency domain multiplexing (FDM) readout system, which is developed at SRON/VTT. We also present the detector energy resolution at X-ray with different photon energies generated by a modulated external X-ray source from 1.45 keV up to 8.9 keV. Multiplexing readout across several pixels has also been performed to evaluate the impact of the thermal crosstalk to the instrument's energy resolution budget requirement. This value results in a derived requirement, for the first neighbour, that is less than 1$\times$10$^{-3}$ when considering the ratio between the amplitude of the crosstalk signal to an X-ray pulse (for example at 5.9 keV)
△ Less
Submitted 19 February, 2021;
originally announced February 2021.
-
Single pixel performance of a 32$\times$32 Ti/Au TES array with broadband X-ray spectra
Authors:
Matteo D'Andrea,
Emanuele Taralli,
Hiroki Akamatsu,
Luciano Gottardi,
Kenichiro Nagayoshi,
Kevin Ravensberg,
Marcel L. Ridder,
Davide Vaccaro,
Cor P. de Vries,
Martin de Wit,
Marcel P. Bruijn,
Ruud W. M. Hoogeveen,
Jian-Rong Gao
Abstract:
We are develo** a kilo-pixels Ti/Au TES array as a backup option for Athena X-IFU. Here we report on single-pixel performance of a 32$\times$32 array operated in a Frequency Division Multiplexing (FDM) readout system, with bias frequencies in the range 1-5 MHz. We have tested the pixels response at several photon energies, by means of a $^{55}$Fe radioactive source (emitting Mn-K$α$ at 5.9 keV)…
▽ More
We are develo** a kilo-pixels Ti/Au TES array as a backup option for Athena X-IFU. Here we report on single-pixel performance of a 32$\times$32 array operated in a Frequency Division Multiplexing (FDM) readout system, with bias frequencies in the range 1-5 MHz. We have tested the pixels response at several photon energies, by means of a $^{55}$Fe radioactive source (emitting Mn-K$α$ at 5.9 keV) and a Modulated X-ray Source (MXS, providing Cr-K$α$ at 5.4 keV and Cu-K$α$ at 8.0 keV). First, we report the procedure used to perform the detector energy scale calibration, usually achieving a calibration accuracy better than $\sim$ 0.5 eV in the 5.4 - 8.9 keV energy range. Then, we present the measured energy resolution at the different energies (best single pixel performance: $Δ$E$_{FWHM}$ = 2.40 $\pm$ 0.09 eV @ 5.4 keV; 2.53 $\pm$ 0.10 eV @ 5.9 keV; 2.78 $\pm$ 0.16 eV @ 8.0 keV), investigating also the performance dependency from the pixel bias frequency and the count rate. Thanks to long background measurements ($\sim$ 1 day), we finally detected also the Al-K$α$ line at 1.5 keV, generated by fluorescence inside the experimental setup. We analyzed this line to obtain a first assessment of the single-pixel performance also at low energy ($Δ$E$_{FWHM}$ = 1.91 eV $\pm$ 0.21 eV @ 1.5 keV), and to evaluate the linearity of the detector response in a large energy band (1.5 - 8.9 keV).
△ Less
Submitted 16 February, 2021;
originally announced February 2021.
-
Frequency Shift Algorithm: Application to a Frequency-Domain Multiplexing Readout of X-ray Transition-Edge Sensor Microcalorimeters
Authors:
D. Vaccaro,
H. Akamatsu,
J. van der Kuur,
P. van der Hulst,
A. C. T. Nieuwenhuizen,
P. van Winden,
L. Gottardi,
R. den Hartog,
M. P. Bruijn,
M. D'Andrea,
J. R. Gao,
J. W. A. den Herder,
R. W. M. Hoogeveen,
B. Jackson,
A. J. van der Linden,
K. Nagayoshi,
K. Ravensberg,
M. L. Ridder,
E. Taralli,
M. de Wit
Abstract:
In the frequency-domain multiplexing (FDM) scheme, transition-edge sensors (TES) are individually coupled to superconducting LC filters and AC biased at MHz frequencies through a common readout line. To make efficient use of the available readout bandwidth and to minimize the effect of non-linearities, the LC resonators are usually designed to be on a regular grid. The lithographic processes howev…
▽ More
In the frequency-domain multiplexing (FDM) scheme, transition-edge sensors (TES) are individually coupled to superconducting LC filters and AC biased at MHz frequencies through a common readout line. To make efficient use of the available readout bandwidth and to minimize the effect of non-linearities, the LC resonators are usually designed to be on a regular grid. The lithographic processes however pose a limit on the accuracy of the effective filter resonance frequencies. Off-resonance bias carriers could be used to suppress the impact of intermodulation distortions, which nonetheless would significantly affect the effective bias circuit and the detector spectral performance. In this paper we present a frequency shift algorithm (FSA) to allow off-resonance readout of TES's while preserving the on-resonance bias circuit and spectral performance, demonstrating its application to the FDM readout of a X-ray TES microcalorimeter array. We discuss the benefits in terms of mitigation of the impact of intermodulation distortions at the cost of increased bias voltage and the scalability of the algorithm to multi-pixel FDM readout. We show that with FSA, in multi-pixel and frequencies shifted on-grid, the line noises due to intermodulation distortion are placed away from the sensitive region in the TES response and the X-ray performance is consistent with the single-pixel, on-resonance level.
△ Less
Submitted 11 February, 2021;
originally announced February 2021.
-
The EChO science case
Authors:
Giovanna Tinetti,
Pierre Drossart,
Paul Eccleston,
Paul Hartogh,
Kate Isaak,
Martin Linder,
Christophe Lovis,
Giusi Micela,
Marc Ollivier,
Ludovic Puig,
Ignasi Ribas,
Ignas Snellen,
Bruce Swinyard. France Allard,
Joanna Barstow,
James Cho,
Athena Coustenis,
Charles Cockell,
Alexandre Correia,
Leen Decin,
Remco de Kok,
Pieter Deroo,
Therese Encrenaz,
Francois Forget,
Alistair Glasse,
Caitlin Griffith
, et al. (326 additional authors not shown)
Abstract:
The discovery of almost 2000 exoplanets has revealed an unexpectedly diverse planet population. Observations to date have shown that our Solar System is certainly not representative of the general population of planets in our Milky Way. The key science questions that urgently need addressing are therefore: What are exoplanets made of? Why are planets as they are? What causes the exceptional divers…
▽ More
The discovery of almost 2000 exoplanets has revealed an unexpectedly diverse planet population. Observations to date have shown that our Solar System is certainly not representative of the general population of planets in our Milky Way. The key science questions that urgently need addressing are therefore: What are exoplanets made of? Why are planets as they are? What causes the exceptional diversity observed as compared to the Solar System?
EChO (Exoplanet Characterisation Observatory) has been designed as a dedicated survey mission for transit and eclipse spectroscopy capable of observing a large and diverse planet sample within its four-year mission lifetime. EChO can target the atmospheres of super-Earths, Neptune-like, and Jupiter-like planets, in the very hot to temperate zones (planet temperatures of 300K-3000K) of F to M-type host stars. Over the next ten years, several new ground- and space-based transit surveys will come on-line (e.g. NGTS, CHEOPS, TESS, PLATO), which will specifically focus on finding bright, nearby systems. The current rapid rate of discovery would allow the target list to be further optimised in the years prior to EChO's launch and enable the atmospheric characterisation of hundreds of planets. Placing the satellite at L2 provides a cold and stable thermal environment, as well as a large field of regard to allow efficient time-critical observation of targets randomly distributed over the sky. A 1m class telescope is sufficiently large to achieve the necessary spectro-photometric precision. The spectral coverage (0.5-11 micron, goal 16 micron) and SNR to be achieved by EChO, thanks to its high stability and dedicated design, would enable a very accurate measurement of the atmospheric composition and structure of hundreds of exoplanets.
△ Less
Submitted 19 February, 2015;
originally announced February 2015.