-
Laser cooling and trap** of $^{224}$Ra$^+$
Authors:
M. Fan,
Roy A. Ready,
H. Li,
S. Kofford,
R. Kwapisz,
C. A. Holliman,
M. S. Ladabaum,
A. N. Gaiser,
J. R. Griswold,
A. M. Jayich
Abstract:
We report laser cooling and trap** of $^{224}$Ra$^+$ ions. This was realized via two-step photoionization loading of radium into an ion trap. A robust source for $^{224}$Ra atoms, which have a 3.6-day half-life, was realized with an effusive oven containing $^{228}$Th, which has a 1.9-yr half-life, which continuously generates $^{224}$Ra via its $α$-decay. We characterized the efficacy of this s…
▽ More
We report laser cooling and trap** of $^{224}$Ra$^+$ ions. This was realized via two-step photoionization loading of radium into an ion trap. A robust source for $^{224}$Ra atoms, which have a 3.6-day half-life, was realized with an effusive oven containing $^{228}$Th, which has a 1.9-yr half-life, which continuously generates $^{224}$Ra via its $α$-decay. We characterized the efficacy of this source and found that after depleting built-up radium the thorium decay provides a continuous source of radium atoms suitable for ion trap**. The vacuum system has been sealed for more than 6 months and continues to trap ions on demand. We also report a measurement of the $^{224}$Ra $7s^2\ ^1$S$_0 \rightarrow 7s7p\ ^1$P$_1$ transition frequency: 621 043 830(60) MHz, which is helpful for efficient photoionization. With this measurement and previous isotope shift measurements we find that the frequency of the same transition in $^{226}$Ra is 621 037 830(60) MHz, which disagrees with the most precise measurement, 621 038 489(15) MHz, which is used for the recommended value in the National Institute of Standards and Technology Atomic Spectra Database.
△ Less
Submitted 19 December, 2023; v1 submitted 31 July, 2023;
originally announced August 2023.
-
Ion optical clocks with three electronic states
Authors:
C. A. Holliman,
M. Fan,
A. M. Jayich
Abstract:
Optical clocks are the apotheosis of precision measurement, but they require frequent maintenance by scientists. The supporting laser systems are a particularly demanding component of these instruments. To reduce complexity and increase robustness we propose an optical clock with trapped alkali-like ions that use the $S_{1/2}\rightarrow D_{3/2}$ electric quadrupole transition. Compared to traditio…
▽ More
Optical clocks are the apotheosis of precision measurement, but they require frequent maintenance by scientists. The supporting laser systems are a particularly demanding component of these instruments. To reduce complexity and increase robustness we propose an optical clock with trapped alkali-like ions that use the $S_{1/2}\rightarrow D_{3/2}$ electric quadrupole transition. Compared to traditional group-II ion clocks this reduces the number of laser wavelengths required, and uses hyperfine state preparation and readout techniques enabled by the nuclear spin $I=1/2$. We consider $^{225}$Ra$^{+}$ as a candidate system for a clock with three electronic states, and discuss the potential to help realize a transportable optical clock.
△ Less
Submitted 22 May, 2023; v1 submitted 9 November, 2022;
originally announced November 2022.
-
Measurement of the Ra$^+$ $7p$ $^{2}P_{3/2}$ state lifetime
Authors:
M. Fan,
C. A. Holliman,
A. Contractor,
C. Zhang,
S. F. Gebretsadkan,
A. M. Jayich
Abstract:
We report a measurement of the radium ion's $7p$ ${}^{2}P_{3/2}$ state lifetime, $τ=4.78(3)$ ns. The measured lifetime is in good agreement with theoretical calculations, and will enable a determination of the differential scalar polarizability of the narrow linewidth $7s$ ${}^{2}S_{1/2}\rightarrow$ $6d$ ${}^{2}D_{5/2}$ optical clock transition.
We report a measurement of the radium ion's $7p$ ${}^{2}P_{3/2}$ state lifetime, $τ=4.78(3)$ ns. The measured lifetime is in good agreement with theoretical calculations, and will enable a determination of the differential scalar polarizability of the narrow linewidth $7s$ ${}^{2}S_{1/2}\rightarrow$ $6d$ ${}^{2}D_{5/2}$ optical clock transition.
△ Less
Submitted 15 February, 2024; v1 submitted 20 February, 2022;
originally announced February 2022.
-
Radium Ion Optical Clock
Authors:
C. A. Holliman,
M. Fan,
A. Contractor,
S. M. Brewer,
A. M. Jayich
Abstract:
We report the first operation of a Ra$^{+}$ optical clock, a promising high-performance clock candidate. The clock uses a single trapped $^{226}$Ra$^{+}$ ion and operates on the $7s\ ^2S_{1/2}\rightarrow$ $6d\ ^2D_{5/2}$ electric quadrupole transition. By self-referencing three pairs of symmetric Zeeman transitions, we demonstrate a frequency instability of 1.1$\times10^{-13}$/$\sqrtτ$, where $τ$…
▽ More
We report the first operation of a Ra$^{+}$ optical clock, a promising high-performance clock candidate. The clock uses a single trapped $^{226}$Ra$^{+}$ ion and operates on the $7s\ ^2S_{1/2}\rightarrow$ $6d\ ^2D_{5/2}$ electric quadrupole transition. By self-referencing three pairs of symmetric Zeeman transitions, we demonstrate a frequency instability of 1.1$\times10^{-13}$/$\sqrtτ$, where $τ$ is the averaging time in seconds. The total systematic uncertainty is evaluated to be ${Δν/ ν= 9 \times 10^{-16}}$. Using the clock, we realize the first measurement of the ratio of the $D_{5/2}$ state to the $S_{1/2}$ state Landé $g$-factors: $g_{D}/g_{S}$ = 0.5988053(11). A Ra$^{+}$ optical clock could improve limits on the time variation of the fine structure constant, $\dot α/ α$, in an optical frequency comparison. The ion also has several features that make it a suitable system for a transportable optical clock.
△ Less
Submitted 25 January, 2022; v1 submitted 18 January, 2022;
originally announced January 2022.
-
Direct measurement of the $7s\ ^2S_{1/2}\rightarrow$ $7p\ ^2P_{3/2}$ transition frequency in $^{226}$Ra$^{+}$
Authors:
C. A. Holliman,
M. Fan,
A. Contractor,
M. W. Straus,
A. M. Jayich
Abstract:
We report a direct measurement of the $7s\ ^2S_{1/2}\rightarrow$ $7p\ ^2P_{3/2}$ electric dipole transition frequency in $^{226}$Ra$^{+}$. With a single laser-cooled radium ion we determine the transition frequency to be 785722.11(3) GHz by directly driving the transition with frequency-doubled light and measuring the frequency of the undoubled light with an iodine reference. This measurement addr…
▽ More
We report a direct measurement of the $7s\ ^2S_{1/2}\rightarrow$ $7p\ ^2P_{3/2}$ electric dipole transition frequency in $^{226}$Ra$^{+}$. With a single laser-cooled radium ion we determine the transition frequency to be 785722.11(3) GHz by directly driving the transition with frequency-doubled light and measuring the frequency of the undoubled light with an iodine reference. This measurement addresses a discrepancy of five combined standard deviations between previously reported values.
△ Less
Submitted 6 November, 2020; v1 submitted 30 August, 2020;
originally announced August 2020.
-
Optical Mass Spectrometry of Cold $\mathrm{RaOH}^+$ and ${\mathrm{RaOCH}_3}^+$
Authors:
M. Fan,
C. A. Holliman,
X. Shi,
H. Zhang,
M. W. Straus,
X. Li,
S. W. Buechele,
A. M. Jayich
Abstract:
We present an all-optical mass spectrometry technique to identify trapped ions. The new method uses laser-cooled ions to determine the mass of a cotrapped dark ion with a sub-dalton resolution within a few seconds. We apply the method to identify the first controlled synthesis of cold, trapped $\mathrm{RaOH}^+$ and ${\mathrm{RaOCH}_3}^+$. These molecules are promising for their sensitivity to time…
▽ More
We present an all-optical mass spectrometry technique to identify trapped ions. The new method uses laser-cooled ions to determine the mass of a cotrapped dark ion with a sub-dalton resolution within a few seconds. We apply the method to identify the first controlled synthesis of cold, trapped $\mathrm{RaOH}^+$ and ${\mathrm{RaOCH}_3}^+$. These molecules are promising for their sensitivity to time and parity violations that could constrain sources of new physics beyond the standard model. The nondestructive nature of the mass spectrometry technique may help identify molecular ions or highly charged ions prior to optical spectroscopy. Unlike previous mass spectrometry techniques for small ion crystals that rely on scanning, the method uses a Fourier transform which is inherently broadband and comparatively fast. The technique's speed provides new opportunities for studying state-resolved chemical reactions in ion traps.
△ Less
Submitted 11 January, 2021; v1 submitted 22 July, 2020;
originally announced July 2020.
-
Measurements of electric quadrupole transition frequencies in $^{226}$Ra$^{+}$
Authors:
C. A. Holliman,
M. Fan,
A. M. Jayich
Abstract:
We report the first driving of the $7s\ ^2S_{1/2}\rightarrow 6d\ ^2D_{3/2}$ and $7s\ ^2S_{1/2}\rightarrow 6d\ ^2D_{5/2}$ electric quadrupole (E2) transitions in Ra$^{+}$. We measure the frequencies of both E2 transitions, and two other low-lying transitions in $^{226}$Ra$^{+}$ that are important for controlling the radium ion's motional and internal states:…
▽ More
We report the first driving of the $7s\ ^2S_{1/2}\rightarrow 6d\ ^2D_{3/2}$ and $7s\ ^2S_{1/2}\rightarrow 6d\ ^2D_{5/2}$ electric quadrupole (E2) transitions in Ra$^{+}$. We measure the frequencies of both E2 transitions, and two other low-lying transitions in $^{226}$Ra$^{+}$ that are important for controlling the radium ion's motional and internal states: $6d\ ^2D_{3/2}\rightarrow 7p\ ^2P_{3/2}^{0}$ and $6d\ ^2D_{5/2}\rightarrow 7p\ ^2P_{3/2}^{0}$.
△ Less
Submitted 31 December, 2019; v1 submitted 14 October, 2019;
originally announced October 2019.
-
Measurement of the $7p\,\, ^2\!P_{3/2}$ state branching fractions in $\mathrm{Ra}^+$
Authors:
M. Fan,
C. A. Holliman,
S. G. Porsev,
M. S. Safronova,
A. M. Jayich
Abstract:
We report a measurement of the radium ion's $7p\,\, ^2\!P_{3/2}$ state branching fractions and improved theoretical calculations. With a single laser-cooled $^{226}\mathrm{Ra}^+$ ion we measure the $P_{3/2}$ branching fractions to the $7s\,\,^2\!S_{1/2}$ ground state 0.87678(20), the $6d\,\,^2\!D_{5/2}$ state 0.10759(10), and the $6d$ ${}^{2}D_{3/2}$ state 0.01563(21).
We report a measurement of the radium ion's $7p\,\, ^2\!P_{3/2}$ state branching fractions and improved theoretical calculations. With a single laser-cooled $^{226}\mathrm{Ra}^+$ ion we measure the $P_{3/2}$ branching fractions to the $7s\,\,^2\!S_{1/2}$ ground state 0.87678(20), the $6d\,\,^2\!D_{5/2}$ state 0.10759(10), and the $6d$ ${}^{2}D_{3/2}$ state 0.01563(21).
△ Less
Submitted 28 January, 2021; v1 submitted 12 September, 2019;
originally announced September 2019.
-
Laser Cooling of Radium Ions
Authors:
M. Fan,
C. A. Holliman,
A. L. Wang,
A. M. Jayich
Abstract:
The unstable radium nucleus is appealing for probing new physics due to its high mass, octupole deformation and energy level structure. Ion traps, with long hold times and low particle numbers, are excellent for work with radioactive species, such as radium and radium-based molecular ions, where low activity, and hence low total numbers, is desirable. We address the challenges associated with the…
▽ More
The unstable radium nucleus is appealing for probing new physics due to its high mass, octupole deformation and energy level structure. Ion traps, with long hold times and low particle numbers, are excellent for work with radioactive species, such as radium and radium-based molecular ions, where low activity, and hence low total numbers, is desirable. We address the challenges associated with the lack of stable isotopes in a tabletop experiment with a low-activity ($\sim 10 \ μ\mathrm{Ci}$) source where we laser-cool trapped radium ions. With a laser-cooled radium ion we measured the $7p\ ^2P_{1/2}^o$ state's branching fractions to the ground state, $7s\ ^2S_{1/2}$, and a metastable excited state, $6d\ ^2D_{3/2}$, to be $p=0.9104(7)$ and $0.0896(7)$, respectively. With a nearby tellurium reference line we measured the $7s\ ^2S_{1/2} \rightarrow 7p\ ^2P_{1/2}^o$ transition frequency, 640.09663(6) THz.
△ Less
Submitted 17 June, 2019; v1 submitted 28 January, 2019;
originally announced January 2019.