Skip to main content

Showing 1–14 of 14 results for author: Holbrook, B

.
  1. arXiv:2006.02506  [pdf, other

    physics.ins-det hep-ex

    The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs

    Authors: D. S. Akerib, C. W. Akerlof, D. Yu. Akimov, A. Alquahtani, S. K. Alsum, T. J. Anderson, N. Angelides, H. M. Araújo, A. Arbuckle, J. E. Armstrong, M. Arthurs, H. Auyeung, S. Aviles, X. Bai, A. J. Bailey, J. Balajthy, S. Balashov, J. Bang, M. J. Barry, D. Bauer, P. Bauer, A. Baxter, J. Belle, P. Beltrame, J. Bensinger , et al. (365 additional authors not shown)

    Abstract: LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherent… ▽ More

    Submitted 28 February, 2022; v1 submitted 3 June, 2020; originally announced June 2020.

    Comments: 45 pages (79 inc. tables), 7 figures, 9 tables

    Journal ref: The European Physical Journal C, Volume 80, Article number: 1044 (2020)

  2. arXiv:1910.09124  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    The LUX-ZEPLIN (LZ) Experiment

    Authors: The LZ Collaboration, D. S. Akerib, C. W. Akerlof, D. Yu. Akimov, A. Alquahtani, S. K. Alsum, T. J. Anderson, N. Angelides, H. M. Araújo, A. Arbuckle, J. E. Armstrong, M. Arthurs, H. Auyeung, X. Bai, A. J. Bailey, J. Balajthy, S. Balashov, J. Bang, M. J. Barry, J. Barthel, D. Bauer, P. Bauer, A. Baxter, J. Belle, P. Beltrame , et al. (357 additional authors not shown)

    Abstract: We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient n… ▽ More

    Submitted 3 November, 2019; v1 submitted 20 October, 2019; originally announced October 2019.

  3. arXiv:1703.09144  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    LUX-ZEPLIN (LZ) Technical Design Report

    Authors: B. J. Mount, S. Hans, R. Rosero, M. Yeh, C. Chan, R. J. Gaitskell, D. Q. Huang, J. Makkinje, D. C. Malling, M. Pangilinan, C. A. Rhyne, W. C. Taylor, J. R. Verbus, Y. D. Kim, H. S. Lee, J. Lee, D. S. Leonard, J. Li, J. Belle, A. Cottle, W. H. Lippincott, D. J. Markley, T. J. Martin, M. Sarychev, T. E. Tope , et al. (237 additional authors not shown)

    Abstract: In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.

    Submitted 27 March, 2017; originally announced March 2017.

    Comments: 392 pages. Submitted to the Department of Energy as part of the documentation for the Critical Decision Numbers Two and Three (CD-2 and CD-3) management processes. Report also available by chapter at <a href="http://hep.ucsb.edu/LZ/TDR/">this URL</a>

    Report number: LBNL-1007256

  4. Identification of Radiopure Titanium for the LZ Dark Matter Experiment and Future Rare Event Searches

    Authors: D. S. Akerib, C. W. Akerlof, D. Yu. Akimov, S. K. Alsum, H. M. Araújo, I. J. Arnquist, M. Arthurs, X. Bai, A. J. Bailey, J. Balajthy, S. Balashov, M. J. Barry, J. Belle, P. Beltrame, T. Benson, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, K. E. Boast, A. Bolozdynya, B. Boxer, R. Bramante, P. Brás, J. H. Buckley, V. V. Bugaev , et al. (180 additional authors not shown)

    Abstract: The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. The large mass and proximity of the cryostat to the active detector volume demand the use of material with extremely low intrinsic radioactivity. We report on the radioassay campaign conducted to identify suitable metals,… ▽ More

    Submitted 26 September, 2017; v1 submitted 8 February, 2017; originally announced February 2017.

    Comments: 13 pages, 3 figures, accepted for publication in Astroparticle Physics

  5. arXiv:1509.02910  [pdf

    physics.ins-det astro-ph.IM hep-ex

    LUX-ZEPLIN (LZ) Conceptual Design Report

    Authors: The LZ Collaboration, D. S. Akerib, C. W. Akerlof, D. Yu. Akimov, S. K. Alsum, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, S. Balashov, M. J. Barry, P. Bauer, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, K. E. Boast, A. I. Bolozdynya, E. M. Boulton, R. Bramante, J. H. Buckley, V. V. Bugaev, R. Bunker, S. Burdin, J. K. Busenitz , et al. (170 additional authors not shown)

    Abstract: The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive exp… ▽ More

    Submitted 23 September, 2015; v1 submitted 9 September, 2015; originally announced September 2015.

    Comments: 278 pages. Submitted to the Department of Energy as part of the documentation for the Critical Decision Number One (CD-1) management process. Report also available by chapter at http://hep.ucsb.edu/LZ/CDR. This version includes corrections of minor typographic errors

    Report number: LBNL-190005

  6. arXiv:1211.3788  [pdf, other

    physics.ins-det hep-ex

    The Large Underground Xenon (LUX) Experiment

    Authors: D. S. Akerib, X. Bai, S. Bedikian, E. Bernard, A. Bernstein, A. Bolozdynya, A. Bradley, D. Byram, S. B. Cahn, C. Camp, M. C. Carmona-Benitez, D. Carr, J. J. Chapman, A. Chiller, C. Chiller, K. Clark, T. Classen, T. Coffey, A. Curioni, E. Dahl, S. Dazeley, L. de Viveiros, A. Dobi, E. Dragowsky, E. Druszkiewicz , et al. (69 additional authors not shown)

    Abstract: The Large Underground Xenon (LUX) collaboration has designed and constructed a dual-phase xenon detector, in order to conduct a search for Weakly Interacting Massive Particles(WIMPs), a leading dark matter candidate. The goal of the LUX detector is to clearly detect (or exclude) WIMPS with a spin independent cross section per nucleon of $2\times 10^{-46}$ cm$^{2}$, equivalent to $\sim$1 event/100… ▽ More

    Submitted 21 November, 2012; v1 submitted 15 November, 2012; originally announced November 2012.

    Comments: 50 pages, 16 figures

    Journal ref: Nuclear Inst. and Methods in Physics Research A704 (2013) 111 - 126

  7. arXiv:1207.3665  [pdf, other

    physics.ins-det astro-ph.IM

    The LUX Prototype Detector: Heat Exchanger Development

    Authors: D. S. Akerib, X. Bai, S. Bedikian, A. Bernstein, A. Bolozdynya, A. Bradley, S. Cahn, D. Carr, J. J. Chapman, K. Clark, T. Classen, A. Curioni, C. E. Dahl, S. Dazeley, L. deViveiros, M. Dragowsky, E. Druszkiewicz, S. Fiorucci, R. J. Gaitskell, C. Hall, C. Faham, B. Holbrook, L. Kastens, K. Kazkaz, J. Kwong , et al. (25 additional authors not shown)

    Abstract: The LUX (Large Underground Xenon) detector is a two-phase xenon Time Projection Chamber (TPC) designed to search for WIMP-nucleon dark matter interactions. As with all noble element detectors, continuous purification of the detector medium is essential to produce a large ($>$1ms) electron lifetime; this is necessary for efficient measurement of the electron signal which in turn is essential for ac… ▽ More

    Submitted 20 January, 2013; v1 submitted 16 July, 2012; originally announced July 2012.

    Comments: 12 pages, 9 figures

  8. arXiv:1205.2272  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    An Ultra-Low Background PMT for Liquid Xenon Detectors

    Authors: D. S. Akerib, X. Bai, E. Bernard, A. Bernstein, A. Bradley, D. Byram, S. B. Cahn, M. C. Carmona-Benitez, D. Carr, J. J. Chapman, Y-D. Chan, K. Clark, T. Coffey, L. deViveiros, M. Dragowsky, E. Druszkiewicz, B. Edwards, C. H. Faham, S. Fiorucci, R. J. Gaitskell, K. R. Gibson, C. Hall, M. Hanhardt, B. Holbrook, M. Ihm , et al. (42 additional authors not shown)

    Abstract: Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark matter experiment, has yielded a positive detection of four common radioactive isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered backgrounds from other det… ▽ More

    Submitted 24 June, 2013; v1 submitted 10 May, 2012; originally announced May 2012.

    Comments: v2 updated to include content after reviewer comments (Sep 2012)

    Journal ref: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Volume 703, 1 March 2013, Pages 1-6

  9. arXiv:1112.1376  [pdf, ps, other

    physics.ins-det hep-ex

    Radio-assay of Titanium samples for the LUX Experiment

    Authors: D. S. Akerib, X. Bai, S. Bedikian, E. Bernard, A. Bernstein, A. Bradley, S. B. Cahn, M. C. Carmona-Benitez, D. Carr, J. J. Chapman, Y-D. Chan, K. Clark, T. Classen, T. Coffey, S. Dazeley, L. deViveiros, M. Dragowsky, E. Druszkiewicz, C. H. Faham, S. Fiorucci, R. J. Gaitskell, K. R. Gibson, C. Hall, M. Hanhardt, B. Holbrook , et al. (41 additional authors not shown)

    Abstract: We report on the screening of samples of titanium metal for their radio-purity. The screening process described in this work led to the selection of materials used in the construction of the cryostats for the Large Underground Xenon (LUX) dark matter experiment. Our measurements establish titanium as a highly desirable material for low background experiments searching for rare events. The sample w… ▽ More

    Submitted 12 February, 2012; v1 submitted 6 December, 2011; originally announced December 2011.

    Comments: The LUX Collaboration

  10. arXiv:1111.2074  [pdf, other

    physics.data-an hep-ex nucl-ex

    LUXSim: A Component-Centric Approach to Low-Background Simulations

    Authors: D. S. Akerib, X. Bai, S. Bedikian, E. Bernard, A. Bernstein, A. Bradley, S. B. Cahn, M. C. Carmona-Benitez, D. Carr, J. J. Chapman, K. Clark, T. Classen, T. Coffey, S. Dazeley, L. de Viveiros, M. Dragowsky, E. Druszkiewicz, C. H. Faham, S. Fiorucci, R. J. Gaitskell, K. R. Gibson, C. Hall, M. Hanhardt, B. Holbrook, M. Ihm , et al. (38 additional authors not shown)

    Abstract: Geant4 has been used throughout the nuclear and high-energy physics community to simulate energy depositions in various detectors and materials. These simulations have mostly been run with a source beam outside the detector. In the case of low-background physics, however, a primary concern is the effect on the detector from radioactivity inherent in the detector parts themselves. From this standpo… ▽ More

    Submitted 8 November, 2011; originally announced November 2011.

    Comments: 45 pages, 15 figures

  11. arXiv:1110.6924  [pdf, other

    physics.ins-det hep-ex

    Development of Readout Interconnections for the Si-W Calorimeter of SiD

    Authors: M. Woods, R. G. Fields, B. Holbrook, R. L. Lander, A. Moskaleva, C. Neher, J. Pasner, M. Tripathi, J. E. Brau, R. E. Frey, D. Strom, M. Breidenbach, D. Freytag, G. Haller, R. Herbst, T. Nelson, S. Schier, B. Schumm

    Abstract: The SiD collaboration is develo** a Si-W sampling electromagnetic calorimeter, with anticipated application for the International Linear Collider. Assembling the modules for such a detector will involve special bonding technologies for the interconnections, especially for attaching a silicon detector wafer to a flex cable readout bus. We review the interconnect technologies involved, including o… ▽ More

    Submitted 21 November, 2011; v1 submitted 31 October, 2011; originally announced October 2011.

    Comments: 8 pages + title, 6 figures

  12. arXiv:1110.0103  [pdf, other

    astro-ph.IM astro-ph.CO

    After LUX: The LZ Program

    Authors: D. C. Malling, D. S. Akerib, H. M. Araujo, X. Bai, S. Bedikian, E. Bernard, A. Bernstein, A. Bradley, S. B. Cahn, M. C. Carmona-Benitez, D. Carr, J. J. Chapman, K. Clark, T. Classen, T. Coffey, A. Curioni, A. Currie, S. Dazeley, L. de Viveiros, M. Dragowsky, E. Druszkiewicz, C. H. Faham, S. Fiorucci, R. J. Gaitskell, K. R. Gibson , et al. (49 additional authors not shown)

    Abstract: The LZ program consists of two stages of direct dark matter searches using liquid Xe detectors. The first stage will be a 1.5-3 tonne detector, while the last stage will be a 20 tonne detector. Both devices will benefit tremendously from research and development performed for the LUX experiment, a 350 kg liquid Xe dark matter detector currently operating at the Sanford Underground Laboratory. In p… ▽ More

    Submitted 13 October, 2011; v1 submitted 1 October, 2011; originally announced October 2011.

    Comments: Conference proceedings from APS DPF 2011. 9 pages, 6 figures

  13. Data Acquisition and Readout System for the LUX Dark Matter Experiment

    Authors: D. S. Akerib, X. Bai, S. Bedikian, E. Bernard, A. Bernstein, A. Bradley, S. B. Cahn, M. C. Carmona-Benitez, D. Carr, J. J. Chapman, K. Clark, T. Classen, T. Coffey, A. Curioni, S. Dazeley, L. deViveiros, M. Dragowsky, E. Druszkiewicz, C. H. Faham, S. Fiorucci, R. J. Gaitskell, K. R. Gibson, C. Hall, M. Hanhardt, B. Holbrook , et al. (38 additional authors not shown)

    Abstract: LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils from interactions with dark matter particles. Signals from the LUX detector are processed by custom-built analog electronics which provide properly shaped signals for the trigger and data acquisition (DAQ) systems. The DAQ is comprised of commercial digitizers with firmware customized for the LUX exper… ▽ More

    Submitted 9 August, 2011; v1 submitted 8 August, 2011; originally announced August 2011.

  14. arXiv:0912.0482  [pdf, ps, other

    astro-ph.CO astro-ph.IM

    Status of the LUX Dark Matter Search

    Authors: S. Fiorucci, D. S. Akerib, S. Bedikian, A. Bernstein, A. Bolozdynya, A. Bradley, D. Carr, J. Chapman, K. Clark, T. Classen, A. Curioni, E. Dahl, S. Dazeley, L. de Viveiros, E. Druszkiewicz, R. Gaitskell, C. Hall, C. Hernandez Faham, B. Holbrook, L. Kastens, K. Kazkaz, R. Lander, K. Lesko, D. Malling, R. Mannino , et al. (22 additional authors not shown)

    Abstract: The Large Underground Xenon (LUX) dark matter search experiment is currently being deployed at the Homestake Laboratory in South Dakota. We will highlight the main elements of design which make the experiment a very strong competitor in the field of direct detection, as well as an easily scalable concept. We will also present its potential reach for supersymmetric dark matter detection, within v… ▽ More

    Submitted 2 December, 2009; originally announced December 2009.

    Comments: 4 pages, in proceedings of the SUSY09 conference

    Journal ref: AIP Conf.Proc.1200:977-980,2010