-
An advanced workflow for single particle imaging with the limited data at an X-ray free-electron laser
Authors:
Dameli Assalauova,
Young Yong Kim,
Sergey Bobkov,
Ruslan Khubbutdinov,
Max Rose,
Roberto Alvarez,
Jakob Andreasson,
Eugeniu Balaur,
Alice Contreras,
Hasan DeMirci,
Luca Gelisio,
Janos Hajdu,
Mark S. Hunter,
Ruslan P. Kurta,
Haoyuan Li,
Matthew McFadden,
Reza Nazari,
Peter Schwander,
Anton Teslyuk,
Peter Walter,
P. Lourdu Xavier,
Chun Hong Yoon,
Sahba Zaared,
Viacheslav A. Ilyin,
Richard A. Kirian
, et al. (3 additional authors not shown)
Abstract:
An improved analysis for single particle imaging (SPI) experiments, using the limited data, is presented here. Results are based on a study of bacteriophage PR772 performed at the AMO instrument at the Linac Coherent Light Source (LCLS) as part of the SPI initiative. Existing methods were modified to cope with the shortcomings of the experimental data: inaccessibility of information from the half…
▽ More
An improved analysis for single particle imaging (SPI) experiments, using the limited data, is presented here. Results are based on a study of bacteriophage PR772 performed at the AMO instrument at the Linac Coherent Light Source (LCLS) as part of the SPI initiative. Existing methods were modified to cope with the shortcomings of the experimental data: inaccessibility of information from the half of the detector and small fraction of single hits. General SPI analysis workflow was upgraded with the expectation-maximization based classification of diffraction patterns and mode decomposition on the final virus structure determination step. The presented processing pipeline allowed us to determine the three-dimensional structure of the bacteriophage PR772 without symmetry constraints with a spatial resolution of 6.9 nm. The obtained resolution was limited by the scattering intensity during the experiment and the relatively small number of single hits.
△ Less
Submitted 15 June, 2020;
originally announced June 2020.
-
Megahertz single-particle imaging at the European XFEL
Authors:
Egor Sobolev,
Serguey Zolotarev,
Klaus Giewekemeyer,
Johan Bielecki,
Kenta Okamoto,
Hemanth K. N. Reddy,
Jakob Andreasson,
Kartik Ayyer,
Imrich Barak,
Sadia Bari,
Anton Barty,
Richard Bean,
Sergey Bobkov,
Henry N. Chapman,
Grzegorz Chojnowski,
Benedikt J. Daurer,
Katerina Dörner,
Tomas Ekeberg,
Leonie Flückiger,
Oxana Galzitskaya,
Luca Gelisio,
Steffen Hauf,
Brenda G. Hogue,
Daniel A. Horke,
Ahmad Hosseinizadeh
, et al. (38 additional authors not shown)
Abstract:
The emergence of high repetition-rate X-ray free-electron lasers (XFELs) powered by superconducting accelerator technology enables the measurement of significantly more experimental data per day than was previously possible. The European XFEL will soon provide 27,000 pulses per second, more than two orders of magnitude more than any other XFEL. The increased pulse rate is a key enabling factor for…
▽ More
The emergence of high repetition-rate X-ray free-electron lasers (XFELs) powered by superconducting accelerator technology enables the measurement of significantly more experimental data per day than was previously possible. The European XFEL will soon provide 27,000 pulses per second, more than two orders of magnitude more than any other XFEL. The increased pulse rate is a key enabling factor for single-particle X-ray diffractive imaging, which relies on averaging the weak diffraction signal from single biological particles. Taking full advantage of this new capability requires that all experimental steps, from sample preparation and delivery to the acquisition of diffraction patterns, are compatible with the increased pulse repetition rate. Here, we show that single-particle imaging can be performed using X-ray pulses at megahertz repetition rates. The obtained results pave the way towards exploiting high repetition-rate X-ray free-electron lasers for single-particle imaging at their full repetition rate.
△ Less
Submitted 14 December, 2019;
originally announced December 2019.
-
Low-signal limit of X-ray single particle imaging
Authors:
Kartik Ayyer,
Andrew J. Morgan,
Andrew A. Aquila,
Hasan DeMirci,
Brenda G. Hogue,
Richard A. Kirian,
P. Lourdu Xavier,
Chun Hong Yoon,
Henry N. Chapman,
Anton Barty
Abstract:
An outstanding question in X-ray single particle imaging experiments has been the feasibility of imaging sub 10-nm-sized biomolecules under realistic experimental conditions where very few photons are expected to be measured in a single snapshot and instrument background may be significant relative to particle scattering. While analyses of simulated data have shown that the determination of an ave…
▽ More
An outstanding question in X-ray single particle imaging experiments has been the feasibility of imaging sub 10-nm-sized biomolecules under realistic experimental conditions where very few photons are expected to be measured in a single snapshot and instrument background may be significant relative to particle scattering. While analyses of simulated data have shown that the determination of an average image should be feasible using Bayesian methods such as the EMC algorithm, this has yet to be demonstrated using experimental data containing realistic non-isotropic instrument background, sample variability and other experimental factors. In this work, we show that the orientation and phase retrieval steps work at photon counts diluted to the signal levels one expects from smaller molecules or with weaker pulses, using data from experimental measurements of 60-nm PR772 viruses. Even when the signal is reduced to a fraction as little as 1/256, the virus electron density determined using ab initio phasing is of almost the same quality as the high-signal data. However, we are still limited by the total number of patterns collected, which may soon be mitigated by the advent of high repetition-rate sources like the European XFEL and LCLS-II.
△ Less
Submitted 27 April, 2020; v1 submitted 10 May, 2019;
originally announced May 2019.