-
Progress towards ultracold Sr for the AION project -- sub-microkelvin atoms and an optical-heterodyne diagnostic tool for injection-locked laser diodes
Authors:
E. Pasatembou,
C. F. A. Baynham,
O. Buchmüller,
D. Evans,
R. Hobson,
L. Iannizzotto-Venezze,
A. Josset
Abstract:
Long-baseline atom interferometers, such as the one to be built by the AION collaboration, require ultra-cold atomic clouds. These are produced by trap** the atoms in Magneto-Optical Traps (MOTs) using high-power, narrow-linewidth lasers. We report on the laser and optical master-slave injection locked system used to address the 1S0 - 3P1 strontium transition at 689 nm, and on the trap** of st…
▽ More
Long-baseline atom interferometers, such as the one to be built by the AION collaboration, require ultra-cold atomic clouds. These are produced by trap** the atoms in Magneto-Optical Traps (MOTs) using high-power, narrow-linewidth lasers. We report on the laser and optical master-slave injection locked system used to address the 1S0 - 3P1 strontium transition at 689 nm, and on the trap** of strontium atoms in a narrowband MOT. We demonstrate the quality of the injection through the characterisation of the injection lock using a novel, easy-to-assemble method which uses a double pass acousto-optic modulator (AOM) to generate and detect a heterodyne beatnote. The reported system is used to produce an atomic cloud at a temperature of 812 +/- 43 nK in a narrowband red MOT.
△ Less
Submitted 12 October, 2023;
originally announced October 2023.
-
Centralised Design and Production of the Ultra-High Vacuum and Laser-Stabilisation Systems for the AION Ultra-Cold Strontium Laboratories
Authors:
B. Stray,
O. Ennis,
S. Hedges,
S. Dey,
M. Langlois,
K. Bongs,
S. Lellouch,
M. Holynski,
B. Bostwick,
J. Chen,
Z. Eyler,
V. Gibson,
T. L. Harte,
M. Hsu,
M. Karzazi,
J. Mitchell,
N. Mouelle,
U. Schneider,
Y. Tang,
K. Tkalcec,
Y. Zhi,
K. Clarke,
A. Vick,
K. Bridges,
J. Coleman
, et al. (47 additional authors not shown)
Abstract:
This paper outlines the centralised design and production of the Ultra-High-Vacuum sidearm and Laser-Stabilisation systems for the AION Ultra-Cold Strontium Laboratories. Commissioning data on the residual gas and steady-state pressures in the sidearm chambers, on magnetic field quality, on laser stabilisation, and on the loading rate for the 3D Magneto-Optical Trap are presented. Streamlining the…
▽ More
This paper outlines the centralised design and production of the Ultra-High-Vacuum sidearm and Laser-Stabilisation systems for the AION Ultra-Cold Strontium Laboratories. Commissioning data on the residual gas and steady-state pressures in the sidearm chambers, on magnetic field quality, on laser stabilisation, and on the loading rate for the 3D Magneto-Optical Trap are presented. Streamlining the design and production of the sidearm and laser stabilisation systems enabled the AION Collaboration to build and equip in parallel five state-of-the-art Ultra-Cold Strontium Laboratories within 24 months by leveraging key expertise in the collaboration. This approach could serve as a model for the development and construction of other cold atom experiments, such as atomic clock experiments and neutral atom quantum computing systems, by establishing dedicated design and production units at national laboratories.
△ Less
Submitted 31 May, 2023;
originally announced May 2023.
-
A Long-Baseline Atom Interferometer at CERN: Conceptual Feasibility Study
Authors:
G. Arduini,
L. Badurina,
K. Balazs,
C. Baynham,
O. Buchmueller,
M. Buzio,
S. Calatroni,
J. -P. Corso,
J. Ellis,
Ch. Gaignant,
M. Guinchard,
T. Hakulinen,
R. Hobson,
A. Infantino,
D. Lafarge,
R. Langlois,
C. Marcel,
J. Mitchell,
M. Parodi,
M. Pentella,
D. Valuch,
H. Vincke
Abstract:
We present results from exploratory studies, supported by the Physics Beyond Colliders (PBC) Study Group, of the suitability of a CERN site and its infrastructure for hosting a vertical atom interferometer (AI) with a baseline of about 100 m. We first review the scientific motivations for such an experiment to search for ultralight dark matter and measure gravitational waves, and then outline the…
▽ More
We present results from exploratory studies, supported by the Physics Beyond Colliders (PBC) Study Group, of the suitability of a CERN site and its infrastructure for hosting a vertical atom interferometer (AI) with a baseline of about 100 m. We first review the scientific motivations for such an experiment to search for ultralight dark matter and measure gravitational waves, and then outline the general technical requirements for such an atom interferometer, using the AION-100 project as an example. We present a possible CERN site in the PX46 access shaft to the Large Hadron Collider (LHC), including the motivations for this choice and a description of its infrastructure. We then assess its compliance with the technical requirements of such an experiment and what upgrades may be needed. We analyse issues related to the proximity of the LHC machine and its ancillary hardware and present a preliminary safety analysis and the required mitigation measures and infrastructure modifications. In conclusion, we identify primary cost drivers and describe constraints on the experimental installation and operation schedules arising from LHC operation. We find no technical obstacles: the CERN site is a very promising location for an AI experiment with a vertical baseline of about 100 m.
△ Less
Submitted 2 April, 2023;
originally announced April 2023.
-
Analysis of atomic-clock data to constrain variations of fundamental constants
Authors:
Nathaniel Sherrill,
Adam O. Parsons,
Charles F. A. Baynham,
William Bowden,
E. Anne Curtis,
Richard Hendricks,
Ian R. Hill,
Richard Hobson,
Helen S. Margolis,
Billy I. Robertson,
Marco Schioppo,
Krzysztof Szymaniec,
Alexandra Tofful,
Jacob Tunesi,
Rachel M. Godun,
Xavier Calmet
Abstract:
We present a new framework to study the time variation of fundamental constants in a model-independent way. Model independence implies more free parameters than assumed in previous studies. Using data from atomic clocks based on $^{87}$Sr, $^{171}$Yb$^+$ and $^{133}$Cs, we set bounds on parameters controlling the variation of the fine-structure constant, $α$, and the electron-to-proton mass ratio,…
▽ More
We present a new framework to study the time variation of fundamental constants in a model-independent way. Model independence implies more free parameters than assumed in previous studies. Using data from atomic clocks based on $^{87}$Sr, $^{171}$Yb$^+$ and $^{133}$Cs, we set bounds on parameters controlling the variation of the fine-structure constant, $α$, and the electron-to-proton mass ratio, $μ$. We consider variations on timescales ranging from a minute to almost a day. In addition, we use our results to derive some of the tightest limits to date on the parameter space of models of ultralight dark matter and axion-like particles.
△ Less
Submitted 15 December, 2023; v1 submitted 9 February, 2023;
originally announced February 2023.
-
Neutrinos from Stored Muons (nuSTORM)
Authors:
L. Alvarez Ruso,
T. Alves,
S. Boyd,
A. Bross,
P. R. Hobson,
P. Kyberd,
J. B. Lagrange,
K. Long,
X. -G. Lu,
J. Pasternak,
M. Pfaff,
C. Rogers
Abstract:
The 2020 Update of the European Strategy for Particle Physics (ESPP) (see https://cds.cern.ch/record/2720129 ) recommended that muon beam R\&D should be considered a high-priority future initiative and that a programme of experimentation be developed to determine the neutrino cross-sections required to extract the most physics from the DUNE and Hyper-K long-baseline experiments. The ENUBET and nuS…
▽ More
The 2020 Update of the European Strategy for Particle Physics (ESPP) (see https://cds.cern.ch/record/2720129 ) recommended that muon beam R\&D should be considered a high-priority future initiative and that a programme of experimentation be developed to determine the neutrino cross-sections required to extract the most physics from the DUNE and Hyper-K long-baseline experiments. The ENUBET and nuSTORM collaborations have begun to work within and alongside the CERN Physics Beyond Colliders study group and the international Muon Collider collaboration to carry out a joint, five-year R\&D programme to deliver a detailed plan for the implementation of an infrastructure in which:
(1) ENUBET and nuSTORM deliver the neutrino cross-section measurement programme identified in the ESPP and allow sensitive searches for physics beyond the Standard Model to be carried out; and in which \ (2) A 6D muon ionisation cooling experiment is delivered as part of the technology development programme defined by the international Muon Collider collaboration.
This document summarises the status of development of the nuSTORM and 6D cooling experiments and identifies opportunities for collaboration in the development of the initiative outlined above.
△ Less
Submitted 9 August, 2022; v1 submitted 14 March, 2022;
originally announced March 2022.
-
Cold Atoms in Space: Community Workshop Summary and Proposed Road-Map
Authors:
Ivan Alonso,
Cristiano Alpigiani,
Brett Altschul,
Henrique Araujo,
Gianluigi Arduini,
Jan Arlt,
Leonardo Badurina,
Antun Balaz,
Satvika Bandarupally,
Barry C Barish Michele Barone,
Michele Barsanti,
Steven Bass,
Angelo Bassi,
Baptiste Battelier,
Charles F. A. Baynham,
Quentin Beaufils,
Aleksandar Belic,
Joel Berge,
Jose Bernabeu,
Andrea Bertoldi,
Robert Bingham,
Sebastien Bize,
Diego Blas,
Kai Bongs,
Philippe Bouyer
, et al. (224 additional authors not shown)
Abstract:
We summarize the discussions at a virtual Community Workshop on Cold Atoms in Space concerning the status of cold atom technologies, the prospective scientific and societal opportunities offered by their deployment in space, and the developments needed before cold atoms could be operated in space. The cold atom technologies discussed include atomic clocks, quantum gravimeters and accelerometers, a…
▽ More
We summarize the discussions at a virtual Community Workshop on Cold Atoms in Space concerning the status of cold atom technologies, the prospective scientific and societal opportunities offered by their deployment in space, and the developments needed before cold atoms could be operated in space. The cold atom technologies discussed include atomic clocks, quantum gravimeters and accelerometers, and atom interferometers. Prospective applications include metrology, geodesy and measurement of terrestrial mass change due to, e.g., climate change, and fundamental science experiments such as tests of the equivalence principle, searches for dark matter, measurements of gravitational waves and tests of quantum mechanics. We review the current status of cold atom technologies and outline the requirements for their space qualification, including the development paths and the corresponding technical milestones, and identifying possible pathfinder missions to pave the way for missions to exploit the full potential of cold atoms in space. Finally, we present a first draft of a possible road-map for achieving these goals, that we propose for discussion by the interested cold atom, Earth Observation, fundamental physics and other prospective scientific user communities, together with ESA and national space and research funding agencies.
△ Less
Submitted 19 January, 2022;
originally announced January 2022.
-
Improving the Q factor of an optical atomic clock using quantum non-demolition measurement
Authors:
William Bowden,
Alvise Vianello,
Ian R Hill,
Marco Schioppo,
Richard Hobson
Abstract:
Quantum non-demolition (QND) measurement is a remarkable tool for the manipulation of quantum systems. It allows specific information to be extracted while still preserving fragile quantum observables of the system. Here we apply cavity-based QND measurement to an optical lattice clock---a type of atomic clock with unrivalled frequency precision---preserving the quantum coherence of the atoms afte…
▽ More
Quantum non-demolition (QND) measurement is a remarkable tool for the manipulation of quantum systems. It allows specific information to be extracted while still preserving fragile quantum observables of the system. Here we apply cavity-based QND measurement to an optical lattice clock---a type of atomic clock with unrivalled frequency precision---preserving the quantum coherence of the atoms after readout with 80\% fidelity. We apply this technique to stabilise the phase of an ultrastable laser to a coherent atomic state via a series of repeated QND measurements. We exploit the improved phase-coherence of the ultrastable laser to interrogate a separate optical lattice clock, using a Ramsey spectroscopy time extended from 300~ms to 2~s. With this technique we maintain 95\% contrast and observe a seven-fold increase in the clock's \emph{Q} factor to $1.7\times10^{15}$.
△ Less
Submitted 21 October, 2020; v1 submitted 20 October, 2020;
originally announced October 2020.
-
A strontium optical lattice clock with $1 \times 10^{-17}$ uncertainty and measurement of its absolute frequency
Authors:
Richard Hobson,
William Bowden,
Alissa Silva,
Charles F. A. Baynham,
Helen S. Margolis,
Patrick E. G. Baird,
Patrick Gill,
Ian R. Hill
Abstract:
We present a measurement of the absolute frequency of the 5s$^2$ $^1$S$_0$ to 5s5p $^3$P$_0$ transition in $^{87}$Sr, which is a secondary representation of the SI second. We describe the optical lattice clock apparatus used for the measurement, and we focus in detail on how its systematic frequency shifts are evaluated with a total fractional uncertainty of $1 \times 10^{-17}$. Traceability to th…
▽ More
We present a measurement of the absolute frequency of the 5s$^2$ $^1$S$_0$ to 5s5p $^3$P$_0$ transition in $^{87}$Sr, which is a secondary representation of the SI second. We describe the optical lattice clock apparatus used for the measurement, and we focus in detail on how its systematic frequency shifts are evaluated with a total fractional uncertainty of $1 \times 10^{-17}$. Traceability to the International System of Units is provided via comparison to International Atomic Time (TAI). Gathering data over 5- and 15-day periods, with the lattice clock operating on average 74$\%$ of the time, we measure the frequency of the transition to be 429228004229873.1(5) Hz, which corresponds to a fractional uncertainty of $1 \times 10^{-15}$. We describe in detail how this uncertainty arises from the intermediate steps linking the optical frequency standard, through our local time scale UTC(NPL), to an ensemble of primary and secondary frequency standards which steer TAI. The calculated absolute frequency of the transition is in good agreement with recent measurements carried out in other laboratories around the world.
△ Less
Submitted 21 May, 2020;
originally announced May 2020.
-
A mid-infrared magneto-optical trap of metastable strontium for an optical lattice clock
Authors:
Richard Hobson,
William Bowden,
Alvise Vianello,
Ian R. Hill,
Patrick Gill
Abstract:
We report on the realization of a magneto-optical trap (MOT) for metastable strontium operating on the 2.92 $μ$m transition between the energy levels $5s5p~^3\mathrm{P}_2$ and $5s4d~^3\mathrm{D}_3$. The strontium atoms are initially captured in a MOT operating on the 461 nm transition between the energy levels $5s^2~^1\mathrm{S}_0$ and $5s5p~^1\mathrm{P}_1$, prior to being transferred into the met…
▽ More
We report on the realization of a magneto-optical trap (MOT) for metastable strontium operating on the 2.92 $μ$m transition between the energy levels $5s5p~^3\mathrm{P}_2$ and $5s4d~^3\mathrm{D}_3$. The strontium atoms are initially captured in a MOT operating on the 461 nm transition between the energy levels $5s^2~^1\mathrm{S}_0$ and $5s5p~^1\mathrm{P}_1$, prior to being transferred into the metastable MOT and cooled to a final temperature of 6 $μ$K. Challenges arising from aligning the mid-infrared and 461 nm light are mitigated by employing the same pyramid reflector to realize both MOTs. Finally, the 2.92 $μ$m transition is used to realize a full cooling sequence for an optical lattice clock, in which cold samples of $^{87}\mathrm{Sr}$ are loaded into a magic-wavelength optical lattice and initialized in a spin-polarized state to allow high-precision spectroscopy of the $5s^2~^1\mathrm{S}_0$ to $5s5p~^3\mathrm{P}_0$ clock transition.
△ Less
Submitted 15 January, 2020;
originally announced January 2020.
-
Cavity-enhanced non-destructive detection of atoms for an optical lattice clock
Authors:
Richard Hobson,
William Bowden,
Alvise Vianello,
Ian R. Hill,
Patrick Gill
Abstract:
We demonstrate a new method of cavity-enhanced non-destructive detection of atoms for a strontium optical lattice clock. The detection scheme is shown to be linear in atom number up to at least 10,000 atoms, to reject technical noise sources, to achieve signal to noise ratio close to the photon shot noise limit, to provide spatially uniform atom-cavity coupling, and to minimize inhomogeneous ac St…
▽ More
We demonstrate a new method of cavity-enhanced non-destructive detection of atoms for a strontium optical lattice clock. The detection scheme is shown to be linear in atom number up to at least 10,000 atoms, to reject technical noise sources, to achieve signal to noise ratio close to the photon shot noise limit, to provide spatially uniform atom-cavity coupling, and to minimize inhomogeneous ac Stark shifts. These features enable detection of atoms with minimal perturbation to the atomic state, a critical step towards realizing an ultra-high-stability, quantum-enhanced optical lattice clock.
△ Less
Submitted 20 December, 2019;
originally announced December 2019.
-
Dynamic decoupling of laser phase noise in compound atomic clocks
Authors:
Sören Dörscher,
Ali Al-Masoudi,
Marcin Bober,
Roman Schwarz,
Richard Hobson,
Uwe Sterr,
Christian Lisdat
Abstract:
The frequency stability achieved by an optical atomic clock ultimately depends on the coherence of its local oscillator. Even the best ultrastable lasers only allow interrogation times of a few seconds, at present. Here we present a universal measurement protocol that overcomes this limitation. Engineered dynamic decoupling of laser phase noise allows any optical atomic clock with high signal-to-n…
▽ More
The frequency stability achieved by an optical atomic clock ultimately depends on the coherence of its local oscillator. Even the best ultrastable lasers only allow interrogation times of a few seconds, at present. Here we present a universal measurement protocol that overcomes this limitation. Engineered dynamic decoupling of laser phase noise allows any optical atomic clock with high signal-to-noise ratio in a single interrogation to reconstruct the laser's phase well beyond its coherence limit. A compound clock is then formed in combination with another optical clock of any type, allowing the latter to achieve significantly higher frequency stability than on its own. We demonstrate implementation of the protocol in a realistic proof-of-principle experiment with a phase reconstruction fidelity of 99 %. The protocol enables minute-long interrogation for the best ultrastable laser systems. Likewise, it can improve clock performance where less stable local oscillators are used, such as in transortable systems.
△ Less
Submitted 29 November, 2019;
originally announced November 2019.
-
AION: An Atom Interferometer Observatory and Network
Authors:
L. Badurina,
E. Bentine,
D. Blas,
K. Bongs,
D. Bortoletto,
T. Bowcock,
K. Bridges,
W. Bowden,
O. Buchmueller,
C. Burrage,
J. Coleman,
G. Elertas,
J. Ellis,
C. Foot,
V. Gibson,
M. G. Haehnelt,
T. Harte,
S. Hedges,
R. Hobson,
M. Holynski,
T. Jones,
M. Langlois,
S. Lellouch,
M. Lewicki,
R. Maiolino
, et al. (16 additional authors not shown)
Abstract:
We outline the experimental concept and key scientific capabilities of AION (Atom Interferometer Observatory and Network), a proposed UK-based experimental programme using cold strontium atoms to search for ultra-light dark matter, to explore gravitational waves in the mid-frequency range between the peak sensitivities of the LISA and LIGO/Virgo/ KAGRA/INDIGO/Einstein Telescope/Cosmic Explorer exp…
▽ More
We outline the experimental concept and key scientific capabilities of AION (Atom Interferometer Observatory and Network), a proposed UK-based experimental programme using cold strontium atoms to search for ultra-light dark matter, to explore gravitational waves in the mid-frequency range between the peak sensitivities of the LISA and LIGO/Virgo/ KAGRA/INDIGO/Einstein Telescope/Cosmic Explorer experiments, and to probe other frontiers in fundamental physics. AION would complement other planned searches for dark matter, as well as probe mergers involving intermediate mass black holes and explore early universe cosmology. AION would share many technical features with the MAGIS experimental programme in the US, and synergies would flow from operating AION in a network with this experiment, as well as with other atom interferometer experiments such as MIGA, ZAIGA and ELGAR. Operating AION in a network with other gravitational wave detectors such as LIGO, Virgo and LISA would also offer many synergies.
△ Less
Submitted 8 May, 2020; v1 submitted 26 November, 2019;
originally announced November 2019.
-
A low-noise resonant input transimpedance amplified photodetector
Authors:
William Bowden,
Alvise Vianello,
Richard Hobson
Abstract:
We present the design and characterisation of a low-noise, resonant input transimpedance amplified photodetector. The device operates at a resonance frequency of $90 \,\textrm{MHz}$ and exhibits an input referred current noise of $1.2\,\textrm{pA}/\sqrt{\textrm{Hz}}$---marginally above the the theoretical limit of $1.0\,\textrm{pA}/\sqrt{\textrm{Hz}}$ set by the room temperature Johnson noise of t…
▽ More
We present the design and characterisation of a low-noise, resonant input transimpedance amplified photodetector. The device operates at a resonance frequency of $90 \,\textrm{MHz}$ and exhibits an input referred current noise of $1.2\,\textrm{pA}/\sqrt{\textrm{Hz}}$---marginally above the the theoretical limit of $1.0\,\textrm{pA}/\sqrt{\textrm{Hz}}$ set by the room temperature Johnson noise of the detector's $16\,\textrm{k}Ω$ transimpedance. As a result, the photodetector allows for shot-noise limited operation for input powers exceeding $14\,μ\textrm{W}$ at $461\,\textrm{nm}$ corresponding to a noise equivalent power of $3.5\,\textrm{pW}/\sqrt{\textrm{Hz}}$. The key design feature which enables this performance is a low-noise, common-source JFET amplifier at the input which helps to reduce the input referred noise contribution of the following amplification stages.
△ Less
Submitted 24 October, 2019;
originally announced October 2019.
-
Direct comparisons of European primary and secondary frequency standards via satellite techniques
Authors:
F. Riedel,
A. Al-Masoudi,
E. Benkler,
S. Dörscher,
V. Gerginov,
C. Grebing,
S. Häfner,
N. Huntemann,
B. Lipphardt,
C. Lisdat,
E. Peik,
D. Piester,
C. Sanner,
C. Tamm,
S. Weyers,
H. Denker,
L. Timmen,
C. Voigt,
D. Calonico,
G. Cerretto,
G. A. Costanzo,
F. Levi,
I. Sesia,
J. Achkar,
J. Guèna
, et al. (24 additional authors not shown)
Abstract:
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taki…
▽ More
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taking into account correlations and gaps in the measurement data, combined overall uncertainties in the range of $1.8 \times 10^{-16}$ to $3.5 \times 10^{-16}$ for the optical clock comparisons were found. The comparison of the fountain clocks yields results with a maximum relative frequency difference of $6.9 \times 10^{-16}$, and combined overall uncertainties in the range of $4.8 \times 10^{-16}$ to $7.7 \times 10^{-16}$.
△ Less
Submitted 9 October, 2019;
originally announced October 2019.
-
AEDGE: Atomic Experiment for Dark Matter and Gravity Exploration in Space
Authors:
Yousef Abou El-Neaj,
Cristiano Alpigiani,
Sana Amairi-Pyka,
Henrique Araujo,
Antun Balaz,
Angelo Bassi,
Lars Bathe-Peters,
Baptiste Battelier,
Aleksandar Belic,
Elliot Bentine,
Jose Bernabeu,
Andrea Bertoldi,
Robert Bingham,
Diego Blas,
Vasiliki Bolpasi,
Kai Bongs,
Sougato Bose,
Philippe Bouyer,
Themis Bowcock,
William Bowden,
Oliver Buchmueller,
Clare Burrage,
Xavier Calmet,
Benjamin Canuel,
Laurentiu-Ioan Caramete
, et al. (107 additional authors not shown)
Abstract:
We propose in this White Paper a concept for a space experiment using cold atoms to search for ultra-light dark matter, and to detect gravitational waves in the frequency range between the most sensitive ranges of LISA and the terrestrial LIGO/Virgo/KAGRA/INDIGO experiments. This interdisciplinary experiment, called Atomic Experiment for Dark Matter and Gravity Exploration (AEDGE), will also compl…
▽ More
We propose in this White Paper a concept for a space experiment using cold atoms to search for ultra-light dark matter, and to detect gravitational waves in the frequency range between the most sensitive ranges of LISA and the terrestrial LIGO/Virgo/KAGRA/INDIGO experiments. This interdisciplinary experiment, called Atomic Experiment for Dark Matter and Gravity Exploration (AEDGE), will also complement other planned searches for dark matter, and exploit synergies with other gravitational wave detectors. We give examples of the extended range of sensitivity to ultra-light dark matter offered by AEDGE, and how its gravitational-wave measurements could explore the assembly of super-massive black holes, first-order phase transitions in the early universe and cosmic strings. AEDGE will be based upon technologies now being developed for terrestrial experiments using cold atoms, and will benefit from the space experience obtained with, e.g., LISA and cold atom experiments in microgravity.
This paper is based on a submission (v1) in response to the Call for White Papers for the Voyage 2050 long-term plan in the ESA Science Programme. ESA limited the number of White Paper authors to 30. However, in this version (v2) we have welcomed as supporting authors participants in the Workshop on Atomic Experiments for Dark Matter and Gravity Exploration held at CERN: ({\tt https://indico.cern.ch/event/830432/}), as well as other interested scientists, and have incorporated additional material.
△ Less
Submitted 10 October, 2019; v1 submitted 2 August, 2019;
originally announced August 2019.
-
A pyramid MOT with integrated optical cavities as a cold atom platform for an optical lattice clock
Authors:
William Bowden,
Richard Hobson,
Ian R. Hill,
Alvise Vianello,
Marco Schioppo,
Alissa Silva,
Helen S. Margolis,
Patrick E. G. Baird,
Patrick Gill
Abstract:
We realize a two-stage, hexagonal pyramid magneto-optical trap (MOT) with strontium, and demonstrate loading of cold atoms into cavity-enhanced 1D and 2D optical lattice traps, all within a single compact assembly of in-vacuum optics. We show that the device is suitable for high-performance quantum technologies, focusing especially on its intended application as a strontium optical lattice clock.…
▽ More
We realize a two-stage, hexagonal pyramid magneto-optical trap (MOT) with strontium, and demonstrate loading of cold atoms into cavity-enhanced 1D and 2D optical lattice traps, all within a single compact assembly of in-vacuum optics. We show that the device is suitable for high-performance quantum technologies, focusing especially on its intended application as a strontium optical lattice clock. We prepare $2\times 10^4$ spin-polarized atoms of $^{87}$Sr in the optical lattice within 500 ms; we observe a vacuum-limited lifetime of atoms in the lattice of 27 s; and we measure a background DC electric field of 12 Vm$^{-1}$ from stray charges, corresponding to a fractional frequency shift of $(-1.2\times 0.8)\times 10^{-18}$ to the strontium clock transition. When used in combination with careful management of the blackbody radiation environment, the device shows potential as a platform for realizing a compact, robust, transportable optical lattice clock with systematic uncertainty at the $10^{-18}$ level.
△ Less
Submitted 31 July, 2019;
originally announced July 2019.
-
Search for transient variations of the fine structure constant and dark matter using fiber-linked optical atomic clocks
Authors:
B. M. Roberts,
P. Delva,
A. Al-Masoudi,
A. Amy-Klein,
C. Bærentsen,
C. F. A. Baynham,
E. Benkler,
S. Bilicki,
S. Bize,
W. Bowden,
J. Calvert,
V. Cambier,
E. Cantin,
E. A. Curtis,
S. Dörscher,
M. Favier,
F. Frank,
P. Gill,
R. M. Godun,
G. Grosche,
C. Guo,
A. Hees,
I. R. Hill,
R. Hobson,
N. Huntemann
, et al. (29 additional authors not shown)
Abstract:
We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in the recorded clock frequency comparisons across the network, we significantly improve the constraints on transient variations of the fine structure constant. For example, we constrain the variation in alpha to <5*10^-17…
▽ More
We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in the recorded clock frequency comparisons across the network, we significantly improve the constraints on transient variations of the fine structure constant. For example, we constrain the variation in alpha to <5*10^-17 for transients of duration 10^3 s. This analysis also presents a possibility to search for dark matter, the mysterious substance hypothesised to explain galaxy dynamics and other astrophysical phenomena that is thought to dominate the matter density of the universe. At the current sensitivity level, we find no evidence for dark matter in the form of topological defects (or, more generally, any macroscopic objects), and we thus place constraints on certain potential couplings between the dark matter and standard model particles, substantially improving upon the existing constraints, particularly for large (>~10^4 km) objects.
△ Less
Submitted 8 July, 2019; v1 submitted 4 July, 2019;
originally announced July 2019.
-
Guidelines for develo** optical clocks with $10^{-18}$ fractional frequency uncertainty
Authors:
Moustafa Abdel-Hafiz,
Piotr Ablewski,
Ali Al-Masoudi,
Héctor Álvarez Martínez,
Petr Balling,
Geoffrey Barwood,
Erik Benkler,
Marcin Bober,
Mateusz Borkowski,
William Bowden,
Roman Ciuryło,
Hubert Cybulski,
Alexandre Didier,
Miroslav Doležal,
Sören Dörscher,
Stephan Falke,
Rachel M. Godun,
Ramiz Hamid,
Ian R. Hill,
Richard Hobson,
Nils Huntemann,
Yann Le Coq,
Rodolphe Le Targat,
Thomas Legero,
Thomas Lindvall
, et al. (20 additional authors not shown)
Abstract:
There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the $10^{-18}$ range, approximately two orders of magnitude better than that of the best caesium primary frequency…
▽ More
There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the $10^{-18}$ range, approximately two orders of magnitude better than that of the best caesium primary frequency standards. This exceptional accuracy and stability is resulting in a growing number of research groups develo** optical clocks. While good review papers covering the topic already exist, more practical guidelines are needed as a complement. The purpose of this document is therefore to provide technical guidance for researchers starting in the field of optical clocks. The target audience includes national metrology institutes (NMIs) wanting to set up optical clocks (or subsystems thereof) and PhD students and postdocs entering the field. Another potential audience is academic groups with experience in atomic physics and atom or ion trap**, but with less experience of time and frequency metrology and optical clock requirements. These guidelines have arisen from the scope of the EMPIR project "Optical clocks with $1 \times 10^{-18}$ uncertainty" (OC18). Therefore, the examples are from European laboratories even though similar work is carried out all over the world. The goal of OC18 was to push the development of optical clocks by improving each of the necessary subsystems: ultrastable lasers, neutral-atom and single-ion traps, and interrogation techniques. This document shares the knowledge acquired by the OC18 project consortium and gives practical guidance on each of these aspects.
△ Less
Submitted 13 August, 2019; v1 submitted 27 June, 2019;
originally announced June 2019.
-
Rydberg Electrometry for Optical Lattice Clocks
Authors:
William Bowden,
Richard Hobson,
Paul Huillery,
Patrick Gill,
Matthew P. A. Jones,
Ian R. Hill
Abstract:
Electrometry is performed using Rydberg states to evaluate the quadratic Stark shift of the $5s^2$ $^1\textrm{S}_0-5s5p$ $^3\textrm{P}_0$ clock transition in strontium. By measuring the Stark shift of the highly excited $5s75d\;^1\textrm{D}_2$ state using electromagnetically induced transparency, we characterize the electric field with sufficient precision to provide tight constraints on the syste…
▽ More
Electrometry is performed using Rydberg states to evaluate the quadratic Stark shift of the $5s^2$ $^1\textrm{S}_0-5s5p$ $^3\textrm{P}_0$ clock transition in strontium. By measuring the Stark shift of the highly excited $5s75d\;^1\textrm{D}_2$ state using electromagnetically induced transparency, we characterize the electric field with sufficient precision to provide tight constraints on the systematic shift to the clock transition. Using the theoretically derived, and experimentally verified, polarizability for this Rydberg state we can measure the residual field with an uncertainty well below $1 \textrm{V} \textrm{m}^{-1}$. This resolution allows us to constrain the fractional frequency uncertainty of the quadratic Stark shift of the clock transition to $2\times10^{-20}$.
△ Less
Submitted 6 June, 2017;
originally announced June 2017.
-
Test of special relativity using a fiber network of optical clocks
Authors:
P. Delva,
J. Lodewyck,
S. Bilicki,
E. Bookjans,
G. Vallet,
R. Le Targat,
P. -E. Pottie,
C. Guerlin,
F. Meynadier,
C. Le Poncin-Lafitte,
O. Lopez,
A. Amy-Klein,
W. -K. Lee,
N. Quintin,
C. Lisdat,
A. Al-Masoudi,
S. Dörscher,
C. Grebing,
G. Grosche,
A. Kuhl,
S. Raupach,
U. Sterr,
I. R. Hill,
R. Hobson,
W. Bowden
, et al. (6 additional authors not shown)
Abstract:
Phase compensated optical fiber links enable high accuracy atomic clocks separated by thousands of kilometers to be compared with unprecedented statistical resolution. By searching for a daily variation of the frequency difference between four strontium optical lattice clocks in different locations throughout Europe connected by such links, we improve upon previous tests of time dilation predicted…
▽ More
Phase compensated optical fiber links enable high accuracy atomic clocks separated by thousands of kilometers to be compared with unprecedented statistical resolution. By searching for a daily variation of the frequency difference between four strontium optical lattice clocks in different locations throughout Europe connected by such links, we improve upon previous tests of time dilation predicted by special relativity. We obtain a constraint on the Robertson--Mansouri--Sexl parameter $|α|\lesssim 1.1 \times10^{-8}$ quantifying a violation of time dilation, thus improving by a factor of around two the best known constraint obtained with Ives--Stilwell type experiments, and by two orders of magnitude the best constraint obtained by comparing atomic clocks. This work is the first of a new generation of tests of fundamental physics using optical clocks and fiber links. As clocks improve, and as fiber links are routinely operated, we expect that the tests initiated in this paper will improve by orders of magnitude in the near future.
△ Less
Submitted 12 June, 2017; v1 submitted 13 March, 2017;
originally announced March 2017.
-
A low maintenance Sr optical lattice clock
Authors:
Ian R. Hill,
Richard Hobson,
William Bowden,
Elizabeth M. Bridge,
Sean Donnellan,
E. Anne Curtis,
Patrick Gill
Abstract:
We describe the Sr optical lattice clock apparatus at NPL with particular emphasis on techniques used to increase reliability and minimise the human requirement in its operation. Central to this is a clock-referenced transfer cavity scheme for the stabilisation of cooling and trap** lasers. We highlight several measures to increase the reliability of the clock with a view towards the realisation…
▽ More
We describe the Sr optical lattice clock apparatus at NPL with particular emphasis on techniques used to increase reliability and minimise the human requirement in its operation. Central to this is a clock-referenced transfer cavity scheme for the stabilisation of cooling and trap** lasers. We highlight several measures to increase the reliability of the clock with a view towards the realisation of an optical time-scale. The clock contributed 502 hours of data over a 25 day period (84% uptime) in a recent measurement campaign with several uninterrupted periods of more than 48 hours. An instability of $2\times10^{-17}$ was reached after $10^5$ s of averaging in an interleaved self-comparison of the clock.
△ Less
Submitted 18 February, 2016;
originally announced February 2016.
-
Modified hyper-Ramsey methods for the elimination of probe shifts in optical clocks
Authors:
R. Hobson,
W. Bowden,
S. A. King,
P. E. G. Baird,
I. R. Hill,
P. Gill
Abstract:
We develop a method of modified hyper-Ramsey spectroscopy in optical clocks, achieving complete immunity to the frequency shifts induced by the probing fields themselves. Using particular pulse sequences with tailored phases, frequencies, and durations, we can derive an error signal centered exactly at the unperturbed atomic resonance with a steep discriminant which is robust against variations in…
▽ More
We develop a method of modified hyper-Ramsey spectroscopy in optical clocks, achieving complete immunity to the frequency shifts induced by the probing fields themselves. Using particular pulse sequences with tailored phases, frequencies, and durations, we can derive an error signal centered exactly at the unperturbed atomic resonance with a steep discriminant which is robust against variations in the probe shift. We experimentally investigate the scheme using the magnetically-induced $^1$S$_0- ^3$P$_0$ transition in $^{88}$Sr, demonstrating automatic suppression of a sizeable \num{2e-13} probe Stark shift to below \num{1e-16} even with very large errors in shift compensation.
△ Less
Submitted 3 November, 2015; v1 submitted 27 October, 2015;
originally announced October 2015.
-
Observation of the rare $B^0_s\toμ^+μ^-$ decay from the combined analysis of CMS and LHCb data
Authors:
The CMS,
LHCb Collaborations,
:,
V. Khachatryan,
A. M. Sirunyan,
A. Tumasyan,
W. Adam,
T. Bergauer,
M. Dragicevic,
J. Erö,
M. Friedl,
R. Frühwirth,
V. M. Ghete,
C. Hartl,
N. Hörmann,
J. Hrubec,
M. Jeitler,
W. Kiesenhofer,
V. Knünz,
M. Krammer,
I. Krätschmer,
D. Liko,
I. Mikulec,
D. Rabady,
B. Rahbaran
, et al. (2807 additional authors not shown)
Abstract:
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six sta…
▽ More
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six standard deviations, and the best measurement of its branching fraction so far. Furthermore, evidence for the $B^0\toμ^+μ^-$ decay is obtained with a statistical significance of three standard deviations. The branching fraction measurements are statistically compatible with SM predictions and impose stringent constraints on several theories beyond the SM.
△ Less
Submitted 17 August, 2015; v1 submitted 17 November, 2014;
originally announced November 2014.
-
Dynamic Power Reduction in a Novel CMOS 5T-SRAM for Low-Power SoC
Authors:
Hooman Jarollahi,
Richard F. Hobson
Abstract:
This paper addresses a novel five-transistor (5T) CMOS SRAM design with high performance and reliability in 65nm CMOS, and illustrates how it reduces the dynamic power consumption in comparison with the conventional and low-power 6T SRAM counterparts. This design can be used as cache memory in processors and low-power portable devices. The proposed SRAM cell features ~13% area reduction compared t…
▽ More
This paper addresses a novel five-transistor (5T) CMOS SRAM design with high performance and reliability in 65nm CMOS, and illustrates how it reduces the dynamic power consumption in comparison with the conventional and low-power 6T SRAM counterparts. This design can be used as cache memory in processors and low-power portable devices. The proposed SRAM cell features ~13% area reduction compared to a conventional 6T cell, and features a unique bit-line and negative supply voltage biasing methodology and ground control architecture to enhance performance, and suppress standby leakage power.
△ Less
Submitted 18 February, 2013;
originally announced February 2013.
-
The design, construction and performance of the MICE scintillating fibre trackers
Authors:
M. Ellis,
P. R. Hobson,
P. Kyberd,
J. J. Nebrensky,
A. Bross,
J. Fagan,
T. Fitzpatrick,
R. Flores,
R. Kubinski,
J. Krider,
R. Rucinski,
P. Rubinov,
C. Tolian,
T. L. Hart,
D. M. Kaplan,
W. Luebke,
B. Freemire,
M. Wojcik,
G. Barber,
D. Clark,
I. Clark,
P. J. Dornan,
A. Fish,
S. Greenwood,
R. Hare
, et al. (27 additional authors not shown)
Abstract:
Charged-particle tracking in the international Muon Ionisation Cooling Experiment (MICE) will be performed using two solenoidal spectrometers, each instrumented with a tracking detector based on 350 μm diameter scintillating fibres. The design and construction of the trackers is described along with the quality-assurance procedures, photon-detection system, readout electronics, reconstruction and…
▽ More
Charged-particle tracking in the international Muon Ionisation Cooling Experiment (MICE) will be performed using two solenoidal spectrometers, each instrumented with a tracking detector based on 350 μm diameter scintillating fibres. The design and construction of the trackers is described along with the quality-assurance procedures, photon-detection system, readout electronics, reconstruction and simulation software and the data-acquisition system. Finally, the performance of the MICE tracker, determined using cosmic rays, is presented.
△ Less
Submitted 11 July, 2010; v1 submitted 19 May, 2010;
originally announced May 2010.
-
Radiation hardness qualification of PbWO4 scintillation crystals for the CMS Electromagnetic Calorimeter
Authors:
The CMS Electromagnetic Calorimeter Group,
P. Adzic,
N. Almeida,
D. Andelin,
I. Anicin,
Z. Antunovic,
R. Arcidiacono,
M. W. Arenton,
E. Auffray,
S. Argiro,
A. Askew,
S. Baccaro,
S. Baffioni,
M. Balazs,
D. Bandurin,
D. Barney,
L. M. Barone,
A. Bartoloni,
C. Baty,
S. Beauceron,
K. W. Bell,
C. Bernet,
M. Besancon,
B. Betev,
R. Beuselinck
, et al. (245 additional authors not shown)
Abstract:
Ensuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews t…
▽ More
Ensuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews the related scientific and technological problems encountered.
△ Less
Submitted 21 December, 2009;
originally announced December 2009.
-
Electroweak Physics
Authors:
G. Azuelos,
U. Baur,
J. van der Bij,
D. Bourilkov,
O. Brein,
R. Casalbuoni,
A. Deandrea,
S. De Curtis,
D. De Florian,
A. Denner,
S. Dittmaier,
M. Dittmar,
A. Dobado,
M. Dobbs,
D. Dominici,
R. Gatto,
A. Ghinculov,
F. Gianotti,
M. Grazzini,
J. B. Hansen,
R. Harper,
S. Haywood,
S. Heinemeyer,
M. J. Herrero,
P. R. Hobson
, et al. (25 additional authors not shown)
Abstract:
We review the prospects for studies in electroweak physics at the LHC.
We review the prospects for studies in electroweak physics at the LHC.
△ Less
Submitted 28 March, 2000;
originally announced March 2000.