-
Direct and in situ examination of Li+ transport kinetics in isotope labelled solid electrolyte interphase
Authors:
Xiaofei Yu,
Stefany Angarita-Gomez,
Yaobin Xu,
Peiyuan Gao,
Jun-Gang Wang,
Xin Zhang,
Hao Jia,
Wu Xu,
Xiaolin Li,
Yingge Du,
Zhijie Xu,
Janet S. Ho,
Kang Xu,
Perla B. Balbuena,
Chongmin Wang,
Zihua Zhu
Abstract:
Here, using unique in-situ liquid secondary ion mass spectroscopy on isotope-labelled solid-electrolyte-interphase (SEI), assisted by cryogenic transmission electron microscopy and constrained ab initio molecular dynamics simulation, for the first time we answer the question regarding Li+ transport mechanism across SEI, and quantitatively determine the Li+-mobility therein. We unequivocally unveil…
▽ More
Here, using unique in-situ liquid secondary ion mass spectroscopy on isotope-labelled solid-electrolyte-interphase (SEI), assisted by cryogenic transmission electron microscopy and constrained ab initio molecular dynamics simulation, for the first time we answer the question regarding Li+ transport mechanism across SEI, and quantitatively determine the Li+-mobility therein. We unequivocally unveil that Li+ transport in SEI follows a mechanism of successive displacement, rather than "direct-hop**". We further reveal, in accordance with spatial-dependence of SEI structure across the thickness, the apparent Li+ self-diffusivity varies from 6.7*10-19 m2/s to 1.0*10-20 m2/s, setting a quantitative gauging of ionic transport behavior of SEI layer against the underlining electrode as well as the rate limiting step of battery operation. This direct study on Li+ kinetics in SEI fills part of the decade-long knowledge gap about the most important component in advanced batteries and provides more precise guidelines to the tailoring of interphasial chemistries for future battery chemistries.
△ Less
Submitted 9 August, 2023;
originally announced August 2023.
-
Wireless powering efficiency of deep-body implantable devices
Authors:
Icaro V. Soares,
Mingxiang Gao,
Zvonimir Sipus,
Anja K. Skrivervik,
John S. Ho,
Denys Nikolayev
Abstract:
The wireless power transfer efficiency to implanted bioelectronic devices is constrained by several frequency-dependent physical mechanisms. Recent works have developed several mathematical formulations to understand these mechanisms and predict the optimal operating conditions. However, existing approaches rely on simplified body models, which are unable to capture important aspects of wireless p…
▽ More
The wireless power transfer efficiency to implanted bioelectronic devices is constrained by several frequency-dependent physical mechanisms. Recent works have developed several mathematical formulations to understand these mechanisms and predict the optimal operating conditions. However, existing approaches rely on simplified body models, which are unable to capture important aspects of wireless power transfer. Therefore, this paper proposes the efficiency analysis approach in anatomical models that can provide insightful information on achieving the optimum operation conditions. First, this approach is validated with a theoretical spherical wave expansion analysis, and the results for a simplified spherical model and a human pectoral model are compared. The results show that although a magnetic receiver outperforms an electric one for near-field operation and both sources could be equally employed in far-field range, it is in mid-field that the maximum efficiency is achieved with an optimum frequency between 1-5 GHz depending on the implantation depth. The receiver orientation is another factor that affects the efficiency, with a maximum difference between the best and worst-case scenarios around five times for the electric source and over 13 times for the magnetic one. This approach is used to analyze the case of a deep-implanted pacemaker wirelessly powered by an on-body transmitter and subjected to stochastic misalignments. We evaluate the efficiency and exposure, and we demonstrate how a buffered transmitter can be tailored to achieve maximum powering efficiency. Finally, design guidelines that lead to optimal implantable wireless power transfer systems are established from the results obtained with the proposed approach.
△ Less
Submitted 5 January, 2023; v1 submitted 19 April, 2022;
originally announced April 2022.
-
Planar immersion lens with metasurfaces
Authors:
John S. Ho,
Brynan Qiu,
Yuji Tanabe,
Alexander J. Yeh,
Shanhui Fan,
Ada S. Y. Poon
Abstract:
The solid immersion lens is a powerful optical tool that allows light entering material from air or vacuum to focus to a spot much smaller than the free-space wavelength. Conventionally, however, they rely on semispherical topographies and are non-planar and bulky, which limits their integration in many applications. Recently, there has been considerable interest in using planar structures, referr…
▽ More
The solid immersion lens is a powerful optical tool that allows light entering material from air or vacuum to focus to a spot much smaller than the free-space wavelength. Conventionally, however, they rely on semispherical topographies and are non-planar and bulky, which limits their integration in many applications. Recently, there has been considerable interest in using planar structures, referred to as metasurfaces, to construct flat optical components for manipulating light in unusual ways. Here, we propose and demonstrate the concept of a planar immersion lens based on metasurfaces. The resulting planar device, when placed near an interface between air and dielectric material, can focus electromagnetic radiation incident from air to a spot in material smaller than the free-space wavelength. As an experimental demonstration, we fabricate an ultrathin and flexible microwave lens and further show that it achieves wireless energy transfer in material mimicking biological tissue.
△ Less
Submitted 12 March, 2015;
originally announced March 2015.
-
Self-tracking Energy Transfer for Neural Stimulation in Untethered Mice
Authors:
John S. Ho,
Yuji Tanabe,
Shrivats Mohan Iyer,
Amelia J. Christensen,
Logan Grosenick,
Karl Deisseroth,
Scott L. Delp,
Ada S. Y. Poon
Abstract:
Optical or electrical stimulation of neural circuits in mice during natural behavior is an important paradigm for studying brain function. Conventional systems for optogenetics and electrical microstimulation require tethers or large head-mounted devices that disrupt animal behavior. We report a method for wireless powering of small-scale implanted devices based on the strong localization of energ…
▽ More
Optical or electrical stimulation of neural circuits in mice during natural behavior is an important paradigm for studying brain function. Conventional systems for optogenetics and electrical microstimulation require tethers or large head-mounted devices that disrupt animal behavior. We report a method for wireless powering of small-scale implanted devices based on the strong localization of energy that occurs during resonant interaction between a radio-frequency cavity and intrinsic modes in mice. The system features self-tracking over a wide (16 cm diameter) operational area, and is used to demonstrate wireless activation of cortical neurons with miniaturized stimulators (10 mm$^{3}$, 20 mg) fully implanted under the skin.
△ Less
Submitted 4 March, 2015;
originally announced March 2015.