-
Generation of a precise time scale assisted by a near-continuously operating optical lattice clock
Authors:
Takumi Kobayashi,
Daisuke Akamatsu,
Kazumoto Hosaka,
Yusuke Hisai,
Akiko Nishiyama,
Akio Kawasaki,
Masato Wada,
Hajime Inaba,
Takehiko Tanabe,
Feng-Lei Hong,
Masami Yasuda
Abstract:
We report on a reduced time variation of a time scale with respect to Coordinated Universal Time (UTC) by steering a hydrogen-maser-based time scale with a near-continuously operating optical lattice clock. The time scale is generated in a post-processing analysis for 230 days with a hydrogen maser with its fractional frequency stability limited by a flicker floor of $2\times10^{-15}$ and an Yb op…
▽ More
We report on a reduced time variation of a time scale with respect to Coordinated Universal Time (UTC) by steering a hydrogen-maser-based time scale with a near-continuously operating optical lattice clock. The time scale is generated in a post-processing analysis for 230 days with a hydrogen maser with its fractional frequency stability limited by a flicker floor of $2\times10^{-15}$ and an Yb optical lattice clock operated with an uptime of 81.6 $\%$. During the 230-day period, the root mean square time variation of our time scale with respect to UTC is 0.52 ns, which is a better performance compared with those of time scales steered by microwave fountain clocks that exhibit root mean square variations from 0.99 ns to 1.6 ns. With the high uptime achieved by the Yb optical lattice clock, our simulation implies the potential of generating a state-of-the-art time scale with a time variation of $<0.1$ ns over a month using a better hydrogen maser reaching the mid $10^{-16}$ level. This work demonstrates that a use of an optical clock with a high uptime enhances the stability of a time scale.
△ Less
Submitted 17 April, 2024;
originally announced April 2024.
-
Search for ultralight dark matter from long-term frequency comparisons of optical and microwave atomic clocks
Authors:
Takumi Kobayashi,
Akifumi Takamizawa,
Daisuke Akamatsu,
Akio Kawasaki,
Akiko Nishiyama,
Kazumoto Hosaka,
Yusuke Hisai,
Masato Wada,
Hajime Inaba,
Takehiko Tanabe,
Masami Yasuda
Abstract:
We search for ultralight scalar dark matter candidates that induce oscillations of the fine structure constant, the electron and quark masses, and the quantum chromodynamics energy scale with frequency comparison data between an $^{171}$Yb optical lattice clock and a $^{133}$Cs fountain microwave clock that span 298 days with an uptime of 15.4 $\%$. New limits on the couplings of the scalar dark m…
▽ More
We search for ultralight scalar dark matter candidates that induce oscillations of the fine structure constant, the electron and quark masses, and the quantum chromodynamics energy scale with frequency comparison data between an $^{171}$Yb optical lattice clock and a $^{133}$Cs fountain microwave clock that span 298 days with an uptime of 15.4 $\%$. New limits on the couplings of the scalar dark matter to electrons and gluons in the mass range from $10^{-22}$ eV/$c^{2}$ to $10^{-20}$ eV/$c^{2}$ are set, assuming that each of these couplings is the dominant source of the modulation in the frequency ratio. The absolute frequency of the $^{171}$Yb clock transition is also determined as $518\,295\,836\,590\,863.69(28)$ Hz, which is one of the important contributions towards a redefinition of the SI second.
△ Less
Submitted 12 December, 2022;
originally announced December 2022.
-
Development of polar nematic fluids with giant-\k{appa} dielectric properties
Authors:
**xing Li,
Hiroya Nishikawa,
Junichi Kougo,
Junchen Zhou,
Shuqi Dai,
Wentao Tang,
Xiuhu Zhao,
Yuki Hisai,
Mingjun Huang,
Satoshi Aya
Abstract:
Super-high-\k{appa} materials that exhibit exceptionally high dielectric permittivity are recognized as potential candidates for a wide range of next-generation photonic and electronic devices. Generally, the high dielectricity for achieving a high-\k{appa} state requires a low symmetry of materials so that most of the discovered high-\k{appa} materials are symmetry-broken crystals. There are scar…
▽ More
Super-high-\k{appa} materials that exhibit exceptionally high dielectric permittivity are recognized as potential candidates for a wide range of next-generation photonic and electronic devices. Generally, the high dielectricity for achieving a high-\k{appa} state requires a low symmetry of materials so that most of the discovered high-\k{appa} materials are symmetry-broken crystals. There are scarce reports on fluidic high-\k{appa} dielectrics. Here we demonstrate a rational molecular design, supported by machine-learning analyses, that introduces high polarity to asymmetric molecules, successfully realizing super-high-\k{appa} fluid materials (dielectric permittivity, ε > 104) and strong second harmonic generation with macroscopic spontaneous polar ordering. The polar structures are confirmed to be identical for all the synthesized materials. Our experiments and computational calculation reveal the unique orientational structures coupled with the emerging polarity. Furthermore, adopting this strategy to high-molecular-weight systems additionally extends the novel material category from monomer to polar polymer materials, creating polar soft matters with spontaneous symmetry breaking.
△ Less
Submitted 28 November, 2020;
originally announced November 2020.
-
Demonstration of the nearly continuous operation of an $^{171}$Yb optical lattice clock for half a year
Authors:
Takumi Kobayashi,
Daisuke Akamatsu,
Kazumoto Hosaka,
Yusuke Hisai,
Masato Wada,
Hajime Inaba,
Tomonari Suzuyama,
Feng-Lei Hong,
Masami Yasuda
Abstract:
Optical lattice clocks surpass primary Cs microwave clocks in frequency stability and accuracy, and are promising candidates for a redefinition of the second in the International System of Units (SI). However, the robustness of optical lattice clocks has not yet reached a level comparable to that of Cs fountain clocks which contribute to International Atomic Time (TAI) by the nearly continuous ope…
▽ More
Optical lattice clocks surpass primary Cs microwave clocks in frequency stability and accuracy, and are promising candidates for a redefinition of the second in the International System of Units (SI). However, the robustness of optical lattice clocks has not yet reached a level comparable to that of Cs fountain clocks which contribute to International Atomic Time (TAI) by the nearly continuous operation. In this paper, we report the long-term operation of an $^{171}$Yb optical lattice clock with a coverage of 80.3% for half a year including uptimes of 93.9% for the first 24 days and 92.6% for the last 35 days. This enables a nearly dead-time-free frequency comparison of the optical lattice clock with TAI over months, which provides a link to the SI second with an uncertainty of low $10^{-16}$. By using this link, the absolute frequency of the $^{1}$S$_{0}-^{3}$P$_{0}$ clock transition of $^{171}$Yb is measured as 518 295 836 590 863.54(26) Hz with a fractional uncertainty of $5.0\times10^{-16}$. This value is in agreement with the recommended frequency of $^{171}$Yb as a secondary representation of the second.
△ Less
Submitted 15 November, 2020;
originally announced November 2020.
-
Improved Frequency Ratio Measurement with 87Sr and 171Yb Optical Lattice Clocks at NMIJ
Authors:
Yusuke Hisai,
Daisuke Akamatsu,
Takumi Kobayashi,
Kazumoto Hosaka,
Hajime Inaba,
Feng-Lei Hong,
Masami Yasuda
Abstract:
We report improved frequency ratio measurement with $^{87}$Sr and $^{171}$Yb optical lattice clocks at the National Metrology Institute of Japan (NMIJ). The $^{87}$Sr optical lattice clock is enhanced with several major modifications and is re-evaluated with a reduced uncertainty of $1.1\times10^{-16}$. We employed a $^{171}$Yb optical lattice clock with an uncertainty of $4\times10^{-16}$ that wa…
▽ More
We report improved frequency ratio measurement with $^{87}$Sr and $^{171}$Yb optical lattice clocks at the National Metrology Institute of Japan (NMIJ). The $^{87}$Sr optical lattice clock is enhanced with several major modifications and is re-evaluated with a reduced uncertainty of $1.1\times10^{-16}$. We employed a $^{171}$Yb optical lattice clock with an uncertainty of $4\times10^{-16}$ that was developed for contributing to International Atomic Time (TAI). The measurement result is $ν_{\mathrm{Yb}}/ν_{\mathrm{Sr}}$ = 1.207 507 039 343 338 58(49)$_{\mathrm{sys}}$(6)$_{\mathrm{stat}}$ with a fractional uncertainty of $4.1\times10^{-16}$, which is 3.4 times smaller than our previous measurement result.
△ Less
Submitted 19 October, 2020;
originally announced October 2020.
-
Uncertainty evaluation of an $^{171}$Yb optical lattice clock at NMIJ
Authors:
Takumi Kobayashi,
Daisuke Akamatsu,
Yusuke Hisai,
Takehiko Tanabe,
Hajime Inaba,
Tomonari Suzuyama,
Feng-Lei Hong,
Kazumoto Hosaka,
Masami Yasuda
Abstract:
We report an uncertainty evaluation of an $^{171}$Yb optical lattice clock with a total fractional uncertainty of $3.6\times10^{-16}$, which is mainly limited by the lattice-induced light shift and the blackbody radiation shift. Our evaluation of the lattice-induced light shift, the density shift, and the second-order Zeeman shift is based on an interleaved measurement where we measure the frequen…
▽ More
We report an uncertainty evaluation of an $^{171}$Yb optical lattice clock with a total fractional uncertainty of $3.6\times10^{-16}$, which is mainly limited by the lattice-induced light shift and the blackbody radiation shift. Our evaluation of the lattice-induced light shift, the density shift, and the second-order Zeeman shift is based on an interleaved measurement where we measure the frequency shift using the alternating stabilization of a clock laser to the $\mathrm{6s^{2}\,^{1}S_{0}-6s6p\,^{3}P_{0}}$ clock transition with two different experimental parameters. In the present evaluation, the uncertainties of two sensitivity coefficients for the lattice-induced hyperpolarizability shift $d$ incorporated in a widely-used light shift model by RIKEN and the second-order Zeeman shift $a_{\mathrm{Z}}$ are improved compared with the uncertainties of previous coefficients. The hyperpolarizability coefficient $d$ is determined by investigating the trap potential depth and the light shifts at the lattice frequencies near the two-photon transitions $\mathrm{6s6p^{3}P_{0}-6s8p^{3}P_{0}}$, $\mathrm{6s8p^{3}P_{2}}$, and $\mathrm{6s5f^{3}F_{2}}$. The obtained values are $d=-1.1(4)$ $\mathrmμ$Hz and $a_{\mathrm{Z}}=-6.6(3)$ Hz/mT$^{2}$. These improved coefficients should reduce the total systematic uncertainties of Yb lattice clocks at other institutes.
△ Less
Submitted 3 January, 2019;
originally announced January 2019.
-
A compact frequency-stabilized pump laser for wavelength conversion in long-distance quantum communication
Authors:
Kohei Ikeda,
Yusuke Hisai,
Kazumichi Yoshii,
Hideo Kosaka,
Feng-Lei Hong,
Tomoyuki Horikiri
Abstract:
We demonstrate a compact frequency-stabilized laser at 1064 nm using Doppler-free saturation absorption spectroscopy of molecular iodine. The achieved laser frequency stability and linewidth are 5.7 10-12 (corresponding to an uncertainty of the laser frequency of 1.6 kHz) and 400 kHz, respectively. The developed frequency-stabilized laser can be used as a pump laser for wavelength conversion from…
▽ More
We demonstrate a compact frequency-stabilized laser at 1064 nm using Doppler-free saturation absorption spectroscopy of molecular iodine. The achieved laser frequency stability and linewidth are 5.7 10-12 (corresponding to an uncertainty of the laser frequency of 1.6 kHz) and 400 kHz, respectively. The developed frequency-stabilized laser can be used as a pump laser for wavelength conversion from visible to telecom (or vice versa) to connect quantum memories utilizing nitrogen-vacancy centers in diamond at remote nodes in fiber-based quantum communication.
△ Less
Submitted 10 July, 2018;
originally announced July 2018.
-
Dual-Mode Operation of an Optical Lattice Clock Using Strontium and Ytterbium Atoms
Authors:
Daisuke Akamatsu,
Takumi Kobayashi,
Yusuke Hisai,
Takehiko Tanabe,
Kazumoto Hosaka,
Masami Yasuda,
Feng-Lei Hong
Abstract:
We have developed an optical lattice clock that can operate in dual modes: a strontium (Sr) clock mode and an ytterbium (Yb) clock mode. Dual-mode operation of the Sr-Yb optical lattice clock is achieved by alternately cooling and trap** $^{87}$Sr and $^{171}$Yb atoms inside the vacuum chamber of the clock. Optical lattices for Sr and Yb atoms were arranged with horizontal and vertical configura…
▽ More
We have developed an optical lattice clock that can operate in dual modes: a strontium (Sr) clock mode and an ytterbium (Yb) clock mode. Dual-mode operation of the Sr-Yb optical lattice clock is achieved by alternately cooling and trap** $^{87}$Sr and $^{171}$Yb atoms inside the vacuum chamber of the clock. Optical lattices for Sr and Yb atoms were arranged with horizontal and vertical configurations, respectively, resulting in a small distance of the order of 100 $μ$m between the trapped Sr and Yb atoms. The $^{1}$S$_{0}$-$^{3}$P$_{0}$ clock transitions in the trapped atoms were interrogated in turn and the clock lasers were stabilized to the transitions. We demonstrated the frequency ratio measurement of the Sr and Yb clock transitions by using the dual-mode operation of the Sr-Yb optical lattice clock. The dual-mode operation can reduce the uncertainty of the blackbody radiation shift in the frequency ratio measurement, because both Sr and Yb atoms share the same blackbody radiation.
△ Less
Submitted 6 June, 2018;
originally announced June 2018.