-
First experimental time-of-flight-based proton radiography using low gain avalanche diodes
Authors:
Felix Ulrich-Pur,
Thomas Bergauer,
Tetyana Galatyuk,
Albert Hirtl,
Matthias Kausel,
Vadym Kedych,
Mladen Kis,
Yevhen Kozymka,
Wilhelm Krüger,
Sergey Linev,
Jan Michel,
Jerzy Pietraszko,
Adrian Rost,
Christian Joachim Schmidt,
Michael Träger,
Michael Traxler
Abstract:
Ion computed tomography (iCT) is an imaging modality for the direct determination of the relative stop** power (RSP) distribution within a patient's body. Usually, this is done by estimating the path and energy loss of ions traversing the scanned volume via a tracking system and a separate residual energy detector. This study, on the other hand, introduces the first experimental study of a novel…
▽ More
Ion computed tomography (iCT) is an imaging modality for the direct determination of the relative stop** power (RSP) distribution within a patient's body. Usually, this is done by estimating the path and energy loss of ions traversing the scanned volume via a tracking system and a separate residual energy detector. This study, on the other hand, introduces the first experimental study of a novel iCT approach based on time-of-flight (TOF) measurements, the so-called Sandwich TOF-iCT concept, which in contrast to any other iCT system, does not require a residual energy detector for the RSP determination. A small TOF-iCT demonstrator was built based on low gain avalanche diodes (LGAD), which are 4D-tracking detectors that allow to simultaneously measure the particle position and time-of-arrival with a precision better than 100um and 100ps, respectively. Using this demonstrator, the material and energy-dependent TOF was measured for several homogeneous PMMA slabs in order to calibrate the acquired TOF against the corresponding water equivalent thickness (WET). With this calibration, two proton radiographs (pRad) of a small aluminium stair phantom were recorded at MedAustron using 83 and 100.4MeV protons. Due to the simplified WET calibration models used in this very first experimental study of this novel approach, the difference between the measured and theoretical WET ranged between 37.09 and 51.12%. Nevertheless, the first TOF-based pRad was successfully recorded showing that LGADs are suitable detector candidates for TOF-iCT. While the system parameters and WET estimation algorithms require further optimization, this work was an important first step to realize Sandwich TOF-iCT. Due to its compact and cost-efficient design, Sandwich TOF-iCT has the potential to make iCT more feasible and attractive for clinical application, which, eventually, could enhance the treatment planning quality.
△ Less
Submitted 22 December, 2023;
originally announced December 2023.
-
Novel ion imaging concept based on time-of-flight measurements with low gain avalanche detectors
Authors:
Felix Ulrich-Pur,
Thomas Bergauer,
Albert Hirtl,
Christian Irmler,
Stefanie Kaser,
Florian Pitters,
Simon Rit
Abstract:
Treatment planning in ion beam therapy requires accurate knowledge of the relative stop** power (RSP) distribution within the patient. Currently, RSP maps are obtained via conventional x-ray computed tomography (CT) by converting the measured attenuation coefficients of photons into RSP values for ions. Alternatively, to avoid conversion errors that are inherent to this method, ion computed tomo…
▽ More
Treatment planning in ion beam therapy requires accurate knowledge of the relative stop** power (RSP) distribution within the patient. Currently, RSP maps are obtained via conventional x-ray computed tomography (CT) by converting the measured attenuation coefficients of photons into RSP values for ions. Alternatively, to avoid conversion errors that are inherent to this method, ion computed tomography (iCT) can be used since it allows determining the RSP directly. In typical iCT systems, which usually consist of a tracking system and a separate residual energy detector, the RSP is obtained by measuring the particle trajectory and the corresponding water equivalent path length (WEPL) of single ions travelling through the patient. Within this work, we explore a novel iCT approach which does not require a residual energy detector. Instead, the WEPL is estimated indirectly by determining the change in time of flight (TOF) due to the energy loss along the ion's path. For this purpose, we have created a Geant4 model of a TOF-iCT system based on low gain avalanche detectors (LGADs), which are fast 4D-tracking detectors that can measure the time of arrival and position of individual particles with high spatial and time precision. To assess the performance of this TOF-iCT concept, we determined the RSP resolution and accuracy for different system settings using the Catphan CTP404 sensitometry phantom. Within the set of investigated system parameters, the lower limit of the RSP accuracy was found at 0.91%, demonstrating the proof-of-principle of this novel TOF-iCT concept. The main advantage of using this approach is that it could potentially facilitate clinical integration due to its compact design, which, however, requires experimental verification and an improvement of the current WEPL calibration procedure.
△ Less
Submitted 27 September, 2022;
originally announced September 2022.
-
Feasibility study of a proton CT system based on 4D-tracking and residual energy determination via time-of-flight
Authors:
Felix Ulrich-Pur,
Thomas Bergauer,
Alexander Burker,
Albert Hirtl,
Christian Irmler,
Stefanie Kaser,
Florian Pitters,
Simon Rit
Abstract:
For dose calculations in ion beam therapy, it is vital to accurately determine the relative stop** power (RSP) distribution within the treated volume. Currently, RSP values are extrapolated from Hounsfield units (HU), measured with x-ray computed tomography (CT), which entails RSP inaccuracies due to conversion errors. A suitable method to improve the treatment plan accuracy is proton computed t…
▽ More
For dose calculations in ion beam therapy, it is vital to accurately determine the relative stop** power (RSP) distribution within the treated volume. Currently, RSP values are extrapolated from Hounsfield units (HU), measured with x-ray computed tomography (CT), which entails RSP inaccuracies due to conversion errors. A suitable method to improve the treatment plan accuracy is proton computed tomography (pCT). A typical pCT system consists of a tracking system and a separate residual energy (or range) detector to measure the RSP distribution directly. This paper introduces a novel pCT system based on a single detector technology, namely low gain avalanche detectors (LGADs). LGADs are fast 4D-tracking detectors, which can be used to simultaneously measure the particle position and time with precise timing and spatial resolution. In contrast to standard pCT systems, the residual energy is determined via a time-of-flight (TOF) measurement between different 4D-tracking stations. The design parameters for a realistic proton computed tomography system based on 4D-tracking detectors were studied and optimized using Monte Carlo simulations. The RSP accuracy and RSP resolution were measured inside the inserts of the CTP404 phantom to estimate the performance of the pCT system. After introducing a dedicated calibration procedure for the TOF calorimeter, RSP accuracies < 0.6 % could be achieved. Furthermore, the design parameters with the strongest impact on the RSP resolution were identified and a strategy to improve RSP resolution is proposed.
△ Less
Submitted 10 September, 2021;
originally announced September 2021.
-
A Proton Computed Tomography Demonstrator for Stop** Power Measurements
Authors:
Felix Ulrich-Pur,
Thomas Bergauer,
Alexander Burker,
Albert Hirtl,
Christian Irmler,
Stefanie Kaser,
Florian Pitters
Abstract:
Particle therapy is an established method to treat deep-seated tumours using accelerator-produced ion beams. For treatment planning, the precise knowledge of the relative stop** power (RSP) within the patient is vital. Conversion errors from x-ray computed tomography (CT) measurements to RSP introduce uncertainties in the applied dose distribution. Using a proton computed tomography (pCT) system…
▽ More
Particle therapy is an established method to treat deep-seated tumours using accelerator-produced ion beams. For treatment planning, the precise knowledge of the relative stop** power (RSP) within the patient is vital. Conversion errors from x-ray computed tomography (CT) measurements to RSP introduce uncertainties in the applied dose distribution. Using a proton computed tomography (pCT) system to measure the SP directly could potentially increase the accuracy of treatment planning. A pCT demonstrator, consisting of double-sided silicon strip detectors (DSSD) as tracker and plastic scintillator slabs coupled to silicon photomultipliers (SiPM) as a range telescope, was developed. After a significant hardware upgrade of the range telescope, a 3D tomogram of an aluminium stair phantom was recorded at the MedAustron facility in Wiener Neustadt, Austria. In total, 80 projections with 6.5x10^5 primary events were acquired and used for the reconstruction of the RSP distribution in the phantom. After applying a straight-line approximation for the particle path inside the phantom, the most probable value (MPV) of the RSP distribution could be measured with an accuracy of 0.59%. The RSP resolution inside the phantom was only 9.3% due to a limited amount of projections and measured events per projection.
△ Less
Submitted 24 June, 2021;
originally announced June 2021.
-
Commissioning of low particle flux for proton beams at MedAustron
Authors:
Felix Ulrich-Pur,
Laurids Adler,
Thomas Bergauer,
Alexander Burker,
Andrea De Franco,
Greta Guidoboni,
Albert Hirtl,
Christian Irmler,
Stefanie Kaser,
Sebastian Nowak,
Florian Pitters,
Mauro Pivi,
Dale Prokopovich,
Claus Schmitzer,
Alexander Wastl
Abstract:
MedAustron is a synchrotron-based particle therapy centre located in Wiener Neustadt, Austria. It features three irradiation rooms for particle therapy, where proton beams with energies up to 252.7 MeV and carbon ions of up to 402.8 MeV/u are available for cancer treatment. In addition to the treatment rooms, MedAustron features a unique beamline exclusively for non-clinical research (NCR). This r…
▽ More
MedAustron is a synchrotron-based particle therapy centre located in Wiener Neustadt, Austria. It features three irradiation rooms for particle therapy, where proton beams with energies up to 252.7 MeV and carbon ions of up to 402.8 MeV/u are available for cancer treatment. In addition to the treatment rooms, MedAustron features a unique beamline exclusively for non-clinical research (NCR). This research beamline is also commissioned for proton energies up to 800 MeV, while available carbon ion energies correspond to the ones available in the clinical treatment rooms. Based on the requirements for particle therapy, all irradiation rooms offer particle rates of up to 10^9 particles/s for protons and 10^7 particles/s for carbon ions. However, for research purposes, lower particle fluxes are required and were therefore commissioned for the NCR beamline. Three particle flux settings with particle rates ranging from ~2.4x10^3 particles/s to ~5.2x10^6 particles/s were established for seven proton energies below 252.7 MeV. In addition to the particle rate, the spot sizes and beam energies were measured for these settings. Furthermore, three low flux settings for 800 MeV protons with particle rates ranging from ~2x10^3 particles/s to ~1.3x10^6 particles/s were commissioned. Since the commissioned low flux settings are in a regime well below the limits of the available standard beam diagnostics, setting up the beam under these new operational conditions entirely relied on the use of external detectors. Furthermore, a beam position measurement based alignment without using the standard beam profile monitors was performed for 800 MeV protons.
△ Less
Submitted 27 May, 2021; v1 submitted 11 February, 2021;
originally announced February 2021.
-
Single particle tracking uncertainties in ion imaging
Authors:
A. Burker,
T. Bergauer,
A. Hirtl,
C. Irmler,
S. Kaser,
B. Knäusl,
F. Pitters,
F. Ulrich-Pur
Abstract:
An extensive comparison of the path uncertainty in single particle tracking systems for ion imaging was carried out based on Monte Carlo simulations. The spatial resolution as function of system parameters such as geometry, detector properties and the energy of proton and helium beams was investigated to serve as a guideline for hardware developments.
Primary particle paths were sampled within a…
▽ More
An extensive comparison of the path uncertainty in single particle tracking systems for ion imaging was carried out based on Monte Carlo simulations. The spatial resolution as function of system parameters such as geometry, detector properties and the energy of proton and helium beams was investigated to serve as a guideline for hardware developments.
Primary particle paths were sampled within a water volume and compared to the most likely path estimate obtained from detector measurements, yielding a depth-dependent uncertainty envelope. The maximum uncertainty along this curve was converted to a conservative estimate of the minimal radiographic pixel spacing for a single set of parameter values.
Simulations with various parameter settings were analysed to obtain an overview of the reachable pixel spacing as function of system parameters. The results were used to determine intervals of detector material budget and position resolution that yield a pixel spacing small enough for clinical dose calculation.
To ensure a pixel spacing below 2 mm, the material budget of a detector should remain below 0.25 % for a position resolution of 200 $\mathrm{μm}$ or below 0.75 % for a resolution of 10 $\mathrm{μm}$. Using protons, a sub-millimetre pixel size could not be achieved for a phantom size of 300 mm or at a large clearance. With helium ions, a sub-millimetre pixel spacing could be achieved even for a large phantom size and clearance, provided the position resolution was less than 100 $\mathrm{μm}$ and material budget was below 0.75 %.
△ Less
Submitted 22 February, 2021; v1 submitted 19 August, 2020;
originally announced August 2020.
-
Imaging with protons at MedAustron
Authors:
F. Ulrich-Pur,
T. Bergauer,
A. Burker,
S. Hatamikia,
A. Hirtl,
C. Irmler,
S. Kaser,
P. Paulitsch,
F. Pitters,
V. Teufelhart
Abstract:
Ion beam therapy has become a frequently applied form of cancer therapy over the last years. The advantage of ion beam therapy over conventional radiotherapy using photons is the strongly localized dose deposition, leading to a reduction of dose applied to surrounding healthy tissue. Currently, treatment planning for proton therapy is based on X-ray computed tomography, which entails certain sourc…
▽ More
Ion beam therapy has become a frequently applied form of cancer therapy over the last years. The advantage of ion beam therapy over conventional radiotherapy using photons is the strongly localized dose deposition, leading to a reduction of dose applied to surrounding healthy tissue. Currently, treatment planning for proton therapy is based on X-ray computed tomography, which entails certain sources of inaccuracy in alculation of the stop** power (SP). A more precise method to acquire the SP is to directly use high energy protons (or other ions such as carbon) and perform proton computed tomography (pCT). With this method, the ions are tracked prior to entering and after leaving the patient and finally their residual energy is measured at the very end. Therefore, an ion imaging demonstrator, comprising a tracking telescope made from double-sided silicon strip detectors and a range telescope as a residual energy detector, was set up. First measurements with this setup were performed at beam tests at MedAustron, a center for ion therapy and research in \mbox{Wiener Neustadt}, \mbox{Austria}. The facility provides three rooms for cancer treatment with proton beams as well as one which is dedicated to non-clinical research. This contribution describes the principle of ion imaging with proton beams in general as well as the design of the experimental setup. Moreover, first results from simulations and recent beam tests as well as ideas for future developments will be presented.
△ Less
Submitted 15 July, 2020; v1 submitted 28 February, 2020;
originally announced March 2020.
-
Line shape analysis of the K$β$ transition in muonic hydrogen
Authors:
D. S. Covita,
D. F. Anagnostopoulos,
H. Fuhrmann,
H. Gorke,
D. Gotta,
A. Gruber,
A. Hirtl,
T. Ishiwatari,
P. Indelicato,
T. S. Jensen,
E. -O. Le Bigot,
V. E. Markushin,
M. Nekipelov,
V. N. Pomerantsev,
V. P. Popov,
J. M. F. dos Santos,
Ph. Schmid,
L. M. Simons,
M. Theisen,
M. Trassinelli,
J. F. C. A. Veloso,
J. Zmeskal
Abstract:
The K$β$ transition in muonic hydrogen was measured with a high-resolution crystal spectrometer. The spectrum is shown to be sensitive to the ground-state hyperfine splitting, the corresponding triplet-to-singlet ratio, and the kinetic energy distribution in the $3p$ state. The hyperfine splitting and triplet-to-singlet ratio are found to be consistent with the values expected from theoretical and…
▽ More
The K$β$ transition in muonic hydrogen was measured with a high-resolution crystal spectrometer. The spectrum is shown to be sensitive to the ground-state hyperfine splitting, the corresponding triplet-to-singlet ratio, and the kinetic energy distribution in the $3p$ state. The hyperfine splitting and triplet-to-singlet ratio are found to be consistent with the values expected from theoretical and experimental investigations and, therefore, were fixed accordingly in order to reduce the uncertainties in the further reconstruction of the kinetic energy distribution. The presence of high-energetic components was established and quantified in both a phenomenological, i.e. cascade-model-free fit, and in a direct deconvolution of the Doppler broadening based on the Bayesian approach.
△ Less
Submitted 5 April, 2018; v1 submitted 18 September, 2017;
originally announced September 2017.
-
Hadronic shift in pionic hydrogen
Authors:
M. Hennebach,
D. F. Anagnostopoulos,
A. Dax,
H. Fuhrmann,
D. Gotta,
A. Gruber,
A. Hirtl,
P. Indelicato,
Y. -W. Liu,
B. Manil,
V. E. Markushin,
A. J. Rusi el Hassani,
L. M. Simons,
M. Trassinelli,
J. Zmeskal
Abstract:
The hadronic shift in pionic hydrogen has been redetermined to be $ε_{1s}=7.086\,\pm\,0.007(stat)\,\pm\,0.006(sys)$\,eV by X-ray spectroscopy of ground state transitions applying various energy calibration schemes. The experiment was performed at the high-intensity low-energy pion beam of the Paul Scherrer Institut by using the cyclotron trap and an ultimate-resolution Bragg spectrometer with bent…
▽ More
The hadronic shift in pionic hydrogen has been redetermined to be $ε_{1s}=7.086\,\pm\,0.007(stat)\,\pm\,0.006(sys)$\,eV by X-ray spectroscopy of ground state transitions applying various energy calibration schemes. The experiment was performed at the high-intensity low-energy pion beam of the Paul Scherrer Institut by using the cyclotron trap and an ultimate-resolution Bragg spectrometer with bent crystals.
△ Less
Submitted 17 December, 2014; v1 submitted 25 June, 2014;
originally announced June 2014.
-
Studies on the Cherenkov Effect for Improved Time Resolution of TOF-PET
Authors:
S. E. Brunner,
L. Gruber,
J. Marton,
K. Suzuki,
A. Hirtl
Abstract:
With the newly gained interest in the time of flight method for positron emission tomography (TOF-PET), many options for pushing the time resolution to its borders have been investigated. As one of these options the exploitation of the Cherenkov effect has been proposed, since it allows to bypass the scintillation process and therefore provides almost instantaneous response to incident 511keV anni…
▽ More
With the newly gained interest in the time of flight method for positron emission tomography (TOF-PET), many options for pushing the time resolution to its borders have been investigated. As one of these options the exploitation of the Cherenkov effect has been proposed, since it allows to bypass the scintillation process and therefore provides almost instantaneous response to incident 511keV annihilation photons. Our simulation studies on the yield of Cherenkov photons, their arrival rate at the photon detector and their angular distribution reveal a significant influence by Cherenkov photons on the rise time of inorganic scintillators - a key-parameter for TOF in PET. A measurement shows the feasibility to detect Cherenkov photons in this low energy range.
△ Less
Submitted 19 November, 2013; v1 submitted 27 May, 2013;
originally announced May 2013.
-
New Approaches for Improvement of TOF-PET
Authors:
Stefan E. Brunner,
Lukas Gruber,
Johann Marton,
Ken Suzuki,
Albert Hirtl
Abstract:
We present results of simulations on the influence of photon propagation and the Cherenkov effect on the time resolution of LSO:Ce scintillators. The influence of the scintillator length on the coincidence time resolution is shown. Furthermore, the impact of the depth of interaction on the time resolution, the light output and the arrival time distribution at the photon detector is simulated and i…
▽ More
We present results of simulations on the influence of photon propagation and the Cherenkov effect on the time resolution of LSO:Ce scintillators. The influence of the scintillator length on the coincidence time resolution is shown. Furthermore, the impact of the depth of interaction on the time resolution, the light output and the arrival time distribution at the photon detector is simulated and it is shown how these information can be used for time walk correction.
△ Less
Submitted 8 May, 2013; v1 submitted 7 May, 2013;
originally announced May 2013.
-
Pionic deuterium
Authors:
Th. Strauch,
F. D. Amaro,
D. Anagnostopoulos,
P. Bühler,
D. S. Covita,
H. Gorke,
D. Gotta,
A. Gruber,
A. Hirtl,
P. Indelicato,
E. -O. Le Bigot,
M. Nekipelov,
J. M. F. dos Santos,
Ph. Schmid,
S. Schlesser,
L. M. Simons,
M. Trassinelli,
J. F. C. A. Veloso,
J. Zmeskal
Abstract:
The strong interaction shift $ε$ and broadening Γ in pionic deuterium have been determined in a high statistics study of the πD(3p - 1s) X-ray transition using a high-resolution crystal spectrometer. The pionic deuterium shift will provide constraints for the pion-nucleon isospin scattering lengths extracted from measurements of shift and broadening in pionic hydrogen. The hadronic broadening is r…
▽ More
The strong interaction shift $ε$ and broadening Γ in pionic deuterium have been determined in a high statistics study of the πD(3p - 1s) X-ray transition using a high-resolution crystal spectrometer. The pionic deuterium shift will provide constraints for the pion-nucleon isospin scattering lengths extracted from measurements of shift and broadening in pionic hydrogen. The hadronic broadening is related to pion absorption and production at threshold. The results are ε= (-2356 {\pm} 31)meV (repulsive) and Γ1s = (1171+23/-49) meV yielding for the complex πD scattering length a = [-(24.99 {\pm} 0.33) + i (6.22+0.12/-0.26)]x10-3/mπ. From the imaginary part, the threshold parameter for pion production is obtained to be α = (251 +5/-11) μb. This allows, in addition, and by using results from pion absorption in 3He at threshold, the determination of the effective couplings g0 and g1 for s-wave pion absorption on isoscalar and isovector NN pairs.
△ Less
Submitted 12 July, 2011; v1 submitted 10 November, 2010;
originally announced November 2010.
-
Precision determination of the dpi -> NN transition strength at threshold
Authors:
Th. Strauch,
F. D. Amaro,
D. F. Anagnostopoulos,
P. Bühler,
D. S. Covita,
H. Gorke,
D. Gotta,
A. Gruber,
A. Hirtl,
P. Indelicato,
E. -O. LeBigot,
M. Nekipelov,
J. M. F. dos Santos,
S. Schlesser,
Ph. Schmid,
L. M. Simons,
M. Trassinelli,
J. F. C. A. Veloso,
J. Zmeskal
Abstract:
An unusual but effective way to determine at threshold the dpi -> NN transition strength is to exploit the hadronic ground-state broadening in pionic deuterium, accessible by x-ray spectroscopy. The broadening is dominated by the true absorption channel dpi- -> nn, which is related to s-wave pion production pp -> dpi+ by charge symmetry and detailed balance. Using the exotic atom circumvents the…
▽ More
An unusual but effective way to determine at threshold the dpi -> NN transition strength is to exploit the hadronic ground-state broadening in pionic deuterium, accessible by x-ray spectroscopy. The broadening is dominated by the true absorption channel dpi- -> nn, which is related to s-wave pion production pp -> dpi+ by charge symmetry and detailed balance. Using the exotic atom circumvents the problem of Coulomb corrections to the cross section as necessary in the production experiments. Our dedicated measurement finds (1171+23/-49) meV for the broadening yielding (252+5/-11) \mub.
△ Less
Submitted 22 March, 2010;
originally announced March 2010.
-
Pionic Deuterium
Authors:
Th. Strauch,
F. D. Amaro,
D. F. Anagnostopoulos,
P. B"\uhler,
D. S. Covita,
H. Gorke,
D. Gotta,
A. Gruber,
A. Hirtl,
P. Indelicato,
E. -O. Le Bigot,
M. Nekipelov,
J. M. F. dos Santos,
Ph. Schmid,
S. Schlesser,
L. M. Simons,
M. Trassinelli,
J. F. C. A. Veloso,
J. Zmeskal
Abstract:
The strong interaction shift and broadening in pionic deuterium have been remeasured with high statistics by means of the (3p-1s) X-ray transition using the cyclotron trap and a high-resolution crystal spectrometer. Preliminary results are (-2325+/-31) meV (repulsive) for the shift and (1171+23/-49} meV for the width, which yields precise values for the pion-deuteron scattering length and the th…
▽ More
The strong interaction shift and broadening in pionic deuterium have been remeasured with high statistics by means of the (3p-1s) X-ray transition using the cyclotron trap and a high-resolution crystal spectrometer. Preliminary results are (-2325+/-31) meV (repulsive) for the shift and (1171+23/-49} meV for the width, which yields precise values for the pion-deuteron scattering length and the threshold parameter for pion production.
△ Less
Submitted 23 February, 2010;
originally announced February 2010.
-
Line shape of the muH(3p - 1s) hyperfine transitions
Authors:
D. S. Covita,
D. F. Anagnostopoulos,
H. Gorke,
D. Gotta,
A. Gruber,
A. Hirtl,
T. Ishiwatari,
P. Indelicato,
E. -O. LeBigot,
M. Nekipelov,
J. M. F. dos Santos,
Ph. Schmid,
L. M. Simons,
M. Trassinelli,
J. F. C. A. Veloso,
J. Zmeskal
Abstract:
The (3p - 1s) X-ray transition to the muonic hydrogen ground state was measured with a high resolution crystal spectrometer. A Doppler effect broadening of the X-ray line was established which could be attributed to different Coulomb de-excitation steps preceding the measured transition. The assumption of a statistical population of the hyperfine levels of the muonic hydrogen ground state was di…
▽ More
The (3p - 1s) X-ray transition to the muonic hydrogen ground state was measured with a high resolution crystal spectrometer. A Doppler effect broadening of the X-ray line was established which could be attributed to different Coulomb de-excitation steps preceding the measured transition. The assumption of a statistical population of the hyperfine levels of the muonic hydrogen ground state was directly confirmed by the experiment and measured values for the hyperfine splitting can be reported. The results allow a decisive test of advanced cascade model calculations and establish a method to extract fundamental strong-interaction parameters from pionic hydrogen experiments.
△ Less
Submitted 10 October, 2008; v1 submitted 9 October, 2008;
originally announced October 2008.
-
Highly charged ion X-rays from Electron-Cyclotron Resonance Ion Sources
Authors:
Paul Indelicato,
S. Boucard,
D. S. Covita,
D. Gotta,
A. Gruber,
A. Hirtl,
H. Fuhrmann,
E. -O. Le Bigot,
S. Schlesser,
J. M. F. Dos Santos,
L. M. Simons,
L. Stingelin,
M. Trassinelli,
J. Veloso,
A. Wasser,
J. Zmeskal
Abstract:
Radiation from the highly-charged ions contained in the plasma of Electron-Cyclotron Resonance Ion Sources constitutes a very bright source of X-rays. Because the ions have a relatively low kinetic energy ($\approx 1$ eV) transitions can be very narrow, containing only small Doppler broadening. We describe preliminary accurate measurements of two and three-electron ions with Z=16--18. We show ho…
▽ More
Radiation from the highly-charged ions contained in the plasma of Electron-Cyclotron Resonance Ion Sources constitutes a very bright source of X-rays. Because the ions have a relatively low kinetic energy ($\approx 1$ eV) transitions can be very narrow, containing only small Doppler broadening. We describe preliminary accurate measurements of two and three-electron ions with Z=16--18. We show how these measurement can test sensitively many-body relativistic calculations or can be used as X-ray standards for precise measurements of X-ray transitions in exotic atoms.
△ Less
Submitted 28 October, 2006;
originally announced October 2006.
-
High Resolution He-like Argon And Sulfur Spectra From The PSI ECRIT
Authors:
Martino Trassinelli,
Sandor Biri,
Stephane Boucard,
Daniel S. Covita,
Detlev Gotta,
Bruno Leoni,
Albert Hirtl,
Paul Indelicato,
Eric-Olivier Le Bigot,
Joaquim M. F. Dos Santos,
Leopold M. Simons,
Lucas Stingelin,
Joao F. C. A. Veloso,
Alfred Wasser,
Johann Zmeskal
Abstract:
We present new results on the X-ray spectroscopy of multicharged argon, sulfur and chlorine obtained with the Electron Cyclotron Resonance Ion Trap (ECRIT) in operation at the Paul Scherrer Institut (Villigen, Switzerland). We used a Johann-type Bragg spectrometer with a spherically-bent crystal, with an energy resolution of about 0.4 eV. The ECRIT itself is of a hybrid type, with a superconduct…
▽ More
We present new results on the X-ray spectroscopy of multicharged argon, sulfur and chlorine obtained with the Electron Cyclotron Resonance Ion Trap (ECRIT) in operation at the Paul Scherrer Institut (Villigen, Switzerland). We used a Johann-type Bragg spectrometer with a spherically-bent crystal, with an energy resolution of about 0.4 eV. The ECRIT itself is of a hybrid type, with a superconducting split coil magnet, special iron inserts which provides the mirror field, and a permanent magnetic hexapole. The high frequency was provided by a 6.4 GHz microwave emitter. We obtained high intensity X-ray spectra of multicharged F-like to He-like argon, sulfur and chlorine with one 1s hole. In particular, we observed the $1s2s^{3}S_1 \to 1s^2^{1}S_0 M1$ and $1s2p^{3}P_2 \to 1s^2^{1}S_0 M2$ transitions in He-like argon, sulfur and chlorine with unprecedented statistics and resolution. The energies of the observed lines are being determined with good accuracy using the He-like M1 line as a reference.
△ Less
Submitted 26 October, 2004;
originally announced October 2004.
-
Energy level displacement of the excited nl state of pionic hydrogen
Authors:
A. N. Ivanov,
M. Faber,
A. Hirtl,
J. Marton,
N. I. Troitskaya
Abstract:
The energy level displacements of the excited nl states of pionic hydrogen and the contribution of the ns -> 1s transitions and the (pi^-p)_Coul -> 1s transitions of the pi^-p pair, coupled by the attractive Coulomb field in the S-wave state with a continuous energy spectrum, to the shift of the energy level of the ground state of pionic hydrogen, caused by strong low-energy interactions, are ca…
▽ More
The energy level displacements of the excited nl states of pionic hydrogen and the contribution of the ns -> 1s transitions and the (pi^-p)_Coul -> 1s transitions of the pi^-p pair, coupled by the attractive Coulomb field in the S-wave state with a continuous energy spectrum, to the shift of the energy level of the ground state of pionic hydrogen, caused by strong low-energy interactions, are calculated within a quantum field theoretic, relativistic covariant and model-independent approach developed in nucl-th/0306047.
△ Less
Submitted 24 November, 2003; v1 submitted 8 October, 2003;
originally announced October 2003.
-
On pionic hydrogen. Quantum field theoretic, relativistic covariant and model-independent approach
Authors:
A. N. Ivanov,
M. Faber,
A. Hirtl,
J. Marton,
N. I. Troitskaya
Abstract:
We consider pionic hydrogen A_(pi p), the bound pi^- p state. Within the quantum field theoretic and relativistic covariant approach we calculate the shift and width of the energy level of the ground state of pionic hydrogen caused by strong low-energy interactions treated perturbatively. The generalization of the Deser-Goldberger-Baumann-Thirring (DGBT) formulas (Phys. Rev. 96, 774 (1954)) is g…
▽ More
We consider pionic hydrogen A_(pi p), the bound pi^- p state. Within the quantum field theoretic and relativistic covariant approach we calculate the shift and width of the energy level of the ground state of pionic hydrogen caused by strong low-energy interactions treated perturbatively. The generalization of the Deser-Goldberger-Baumann-Thirring (DGBT) formulas (Phys. Rev. 96, 774 (1954)) is given. The generalized DGBT formulas for the energy level displacement of the ground state of pionic hydrogen contain the non-perturbative and model-independent correction about 1%, caused by the relativistic covariant smearing of the wave function of the ground state around origin. This non-perturbative correction is very important for the precise extraction of the S-wave scattering lengths of pion-nucleon scattering from the experimental data on the energy level displacements in pionic hydrogen by the PSI Collaboration. In addition the shift of the energy level of the ground state of pionic hydrogen is improved by the second order correction of strong low-energy interactions which is about 0.1%. This testifies the applicability of the perturbative treatment of strong low-energy interactions to the analysis of pionic hydrogen. We show that the width of the energy level of the ground state of pionic hydrogen is valid to all order of perturbation theory in strong low-energy interactions.
△ Less
Submitted 20 November, 2003; v1 submitted 17 June, 2003;
originally announced June 2003.
-
Vortices in the SU(2)-Higgs model -- Vortices and the covariant adjoint Laplacian
Authors:
Roman Bertle,
Manfried Faber,
Albert Hirtl
Abstract:
Vortices in the SU(2)--Higgs model: The presence of a fundamental Higgs in the SU(N)-Higgs model yields color screening at some finite distance. Whereas the transition to the Higgs "phase" is accompanied by a suppression of projected center vortices, there is nearly no influence of color screening on the vortex properties in the confined "phase". Hence the behavior of the Wilson loop can be desc…
▽ More
Vortices in the SU(2)--Higgs model: The presence of a fundamental Higgs in the SU(N)-Higgs model yields color screening at some finite distance. Whereas the transition to the Higgs "phase" is accompanied by a suppression of projected center vortices, there is nearly no influence of color screening on the vortex properties in the confined "phase". Hence the behavior of the Wilson loop can be described in both phases within the vortex picture of confinement.
Vortices and the covariant adjoint Laplacian: Laplacian center gauge is a method to localize center vortices in SU(N) gauge theory. We show that the eigenvectors of the covariant adjoint Laplacian identify vortices for a special class of gauge field configurations. However, for Monte Carlo generated configurations, modified approaches are required.
△ Less
Submitted 15 October, 2001;
originally announced October 2001.