In-Orbit Performance of the Hard X-ray Detector on board Suzaku
Authors:
M. Kokubun,
K. Makishima,
T. Takahashi,
T. Murakami,
M. Tashiro,
Y. Fukazawa,
T. Kamae,
G. M. Madejski,
K. Nakazawa,
K. Yamaoka,
Y. Terada,
D. Yonetoku,
S. Watanabe,
T. Tamagawa,
T. Mizuno,
A. Kubota,
N. Isobe,
I. Takahashi,
G. Sato,
H. Takahashi,
S. Hong,
M. Kawaharada,
N. Kawano,
T. Mitani,
M. Murashima
, et al. (32 additional authors not shown)
Abstract:
The in-orbit performance and calibration of the Hard X-ray Detector (HXD) on board the X-ray astronomy satellite Suzaku are described. Its basic performances, including a wide energy bandpass of 10-600 keV, energy resolutions of ~4 keV (FWHM) at 40 keV and ~11% at 511 keV, and a high background rejection efficiency, have been confirmed by extensive in-orbit calibrations. The long-term gains of P…
▽ More
The in-orbit performance and calibration of the Hard X-ray Detector (HXD) on board the X-ray astronomy satellite Suzaku are described. Its basic performances, including a wide energy bandpass of 10-600 keV, energy resolutions of ~4 keV (FWHM) at 40 keV and ~11% at 511 keV, and a high background rejection efficiency, have been confirmed by extensive in-orbit calibrations. The long-term gains of PIN-Si diodes have been stable within 1% for half a year, and those of scintillators have decreased by 5-20%. The residual non-X-ray background of the HXD is the lowest among past non-imaging hard X-ray instruments in energy ranges of 15-70 and 150-500 keV. We provide accurate calibrations of energy responses, angular responses, timing accuracy of the HXD, and relative normalizations to the X-ray CCD cameras using multiple observations of the Crab Nebula.
△ Less
Submitted 7 November, 2006;
originally announced November 2006.
Hard X-ray Detector (HXD) on Board Suzaku
Authors:
T. Takahashi,
K. Abe,
M. Endo,
Y. Endo,
Y. Ezoe,
Y. Fukazawa,
M. Hamaya,
S. Hirakuri,
S. Hong,
M. Horii,
H. Inoue,
N. Isobe,
T. Itoh,
N. Iyomoto,
T. Kamae,
D. Kasama,
J. Kataoka,
H. Kato,
M. Kawaharada,
N. Kawano,
K. Kawashima,
S. Kawasoe,
T. Kishishita,
T. Kitaguchi,
Y. Kobayashi
, et al. (44 additional authors not shown)
Abstract:
The Hard X-ray Detector (HXD) on board Suzaku covers a wide energy range from 10 keV to 600 keV by combination of silicon PIN diodes and GSO scintillators. The HXD is designed to achieve an extremely low in-orbit back ground based on a combination of new techniques, including the concept of well-type active shield counter. With an effective area of 142 cm^2 at 20 keV and 273 cm2 at 150 keV, the…
▽ More
The Hard X-ray Detector (HXD) on board Suzaku covers a wide energy range from 10 keV to 600 keV by combination of silicon PIN diodes and GSO scintillators. The HXD is designed to achieve an extremely low in-orbit back ground based on a combination of new techniques, including the concept of well-type active shield counter. With an effective area of 142 cm^2 at 20 keV and 273 cm2 at 150 keV, the background level at the sea level reached ~1x10^{-5} cts s^{-1} cm^{-2} keV^{-1} at 30 keV for the PI N diodes, and ~2x10^{-5} cts s^{-1} cm^{-2} keV^{-1} at 100 keV, and ~7x10^{-6} cts s^{-1} cm^{-2} keV^{-1} at 200 keV for the phoswich counter. Tight active shielding of the HXD results in a large array of guard counters surrounding the main detector parts. These anti-coincidence counters, made of ~4 cm thick BGO crystals, have a large effective area for sub-MeV to MeV gamma-rays. They work as an excellent gamma-ray burst monitor with limited angular resolution (~5 degree). The on-board signal-processing system and the data transmitted to the ground are also described.
△ Less
Submitted 7 November, 2006;
originally announced November 2006.