-
The Detector System of The Daya Bay Reactor Neutrino Experiment
Authors:
F. P. An,
J. Z. Bai,
A. B. Balantekin,
H. R. Band,
D. Beavis,
W. Beriguete,
M. Bishai,
S. Blyth,
R. L. Brown,
I. Butorov,
D. Cao,
G. F. Cao,
J. Cao,
R. Carr,
W. R. Cen,
W. T. Chan,
Y. L. Chan,
J. F. Chang,
L. C. Chang,
Y. Chang,
C. Chasman,
H. Y. Chen,
H. S. Chen,
M. J. Chen,
Q. Y. Chen
, et al. (310 additional authors not shown)
Abstract:
The Daya Bay experiment was the first to report simultaneous measurements of reactor antineutrinos at multiple baselines leading to the discovery of $\barν_e$ oscillations over km-baselines. Subsequent data has provided the world's most precise measurement of $\rm{sin}^22θ_{13}$ and the effective mass splitting $Δm_{ee}^2$. The experiment is located in Daya Bay, China where the cluster of six nucl…
▽ More
The Daya Bay experiment was the first to report simultaneous measurements of reactor antineutrinos at multiple baselines leading to the discovery of $\barν_e$ oscillations over km-baselines. Subsequent data has provided the world's most precise measurement of $\rm{sin}^22θ_{13}$ and the effective mass splitting $Δm_{ee}^2$. The experiment is located in Daya Bay, China where the cluster of six nuclear reactors is among the world's most prolific sources of electron antineutrinos. Multiple antineutrino detectors are deployed in three underground water pools at different distances from the reactor cores to search for deviations in the antineutrino rate and energy spectrum due to neutrino mixing. Instrumented with photomultiplier tubes (PMTs), the water pools serve as shielding against natural radioactivity from the surrounding rock and provide efficient muon tagging. Arrays of resistive plate chambers over the top of each pool provide additional muon detection. The antineutrino detectors were specifically designed for measurements of the antineutrino flux with minimal systematic uncertainty. Relative detector efficiencies between the near and far detectors are known to better than 0.2%. With the unblinding of the final two detectors' baselines and target masses, a complete description and comparison of the eight antineutrino detectors can now be presented. This paper describes the Daya Bay detector systems, consisting of eight antineutrino detectors in three instrumented water pools in three underground halls, and their operation through the first year of eight detector data-taking.
△ Less
Submitted 7 January, 2016; v1 submitted 17 August, 2015;
originally announced August 2015.
-
Search for a Light Sterile Neutrino at Daya Bay
Authors:
F. P. An,
A. B. Balantekin,
H. R. Band,
W. Beriguete,
M. Bishai,
S. Blyth,
I. Butorov,
G. F. Cao,
J. Cao,
Y. L. Chan,
J. F. Chang,
L. C. Chang,
Y. Chang,
C. Chasman,
H. Chen,
Q. Y. Chen,
S. M. Chen,
X. Chen,
X. Chen,
Y. X. Chen,
Y. Chen,
Y. P. Cheng,
J. J. Cherwinka,
M. C. Chu,
J. P. Cummings
, et al. (210 additional authors not shown)
Abstract:
A search for light sterile neutrino mixing was performed with the first 217 days of data from the Daya Bay Reactor Antineutrino Experiment. The experiment's unique configuration of multiple baselines from six 2.9~GW$_{\rm th}$ nuclear reactors to six antineutrino detectors deployed in two near (effective baselines 512~m and 561~m) and one far (1579~m) underground experimental halls makes it possib…
▽ More
A search for light sterile neutrino mixing was performed with the first 217 days of data from the Daya Bay Reactor Antineutrino Experiment. The experiment's unique configuration of multiple baselines from six 2.9~GW$_{\rm th}$ nuclear reactors to six antineutrino detectors deployed in two near (effective baselines 512~m and 561~m) and one far (1579~m) underground experimental halls makes it possible to test for oscillations to a fourth (sterile) neutrino in the $10^{\rm -3}~{\rm eV}^{2} < |Δm_{41}^{2}| < 0.3~{\rm eV}^{2}$ range. The relative spectral distortion due to electron antineutrino disappearance was found to be consistent with that of the three-flavor oscillation model. The derived limits on $\sin^22θ_{14}$ cover the $10^{-3}~{\rm eV}^{2} \lesssim |Δm^{2}_{41}| \lesssim 0.1~{\rm eV}^{2}$ region, which was largely unexplored.
△ Less
Submitted 8 October, 2014; v1 submitted 27 July, 2014;
originally announced July 2014.
-
Independent Measurement of Theta13 via Neutron Capture on Hydrogen at Daya Bay
Authors:
Daya Bay Collaboration,
F. P. An,
A. B. Balantekin,
H. R. Band,
W. Beriguete,
M. Bishai,
S. Blyth,
I. Butorov,
G. F. Cao,
J. Cao,
Y. L. Chan,
J. F. Chang,
L. C. Chang,
Y. Chang,
C. Chasman,
H. Chen,
Q. Y. Chen,
S. M. Chen,
X. Chen,
X. Chen,
Y. X. Chen,
Y. Chen,
Y. P. Cheng,
J. J. Cherwinka,
M. C. Chu
, et al. (210 additional authors not shown)
Abstract:
A new measurement of the $θ_{13}$ mixing angle has been obtained at the Daya Bay Reactor Neutrino Experiment via the detection of inverse beta decays tagged by neutron capture on hydrogen. The antineutrino events for hydrogen capture are distinct from those for gadolinium capture with largely different systematic uncertainties, allowing a determination independent of the gadolinium-capture result…
▽ More
A new measurement of the $θ_{13}$ mixing angle has been obtained at the Daya Bay Reactor Neutrino Experiment via the detection of inverse beta decays tagged by neutron capture on hydrogen. The antineutrino events for hydrogen capture are distinct from those for gadolinium capture with largely different systematic uncertainties, allowing a determination independent of the gadolinium-capture result and an improvement on the precision of $θ_{13}$ measurement. With a 217-day antineutrino data set obtained with six antineutrino detectors and from six 2.9 GW$_{th}$ reactors, the rate deficit observed at the far hall is interpreted as $\sin^22θ_{13}=0.083\pm0.018$ in the three-flavor oscillation model. When combined with the gadolinium-capture result from Daya Bay, we obtain $\sin^22θ_{13}=0.089\pm0.008$ as the final result for the six-antineutrino-detector configuration of the Daya Bay experiment.
△ Less
Submitted 23 July, 2014; v1 submitted 25 June, 2014;
originally announced June 2014.
-
Spectral measurement of electron antineutrino oscillation amplitude and frequency at Daya Bay
Authors:
Daya Bay Collaboration,
F. P. An,
A. B. Balantekin,
H. R. Band,
W. Beriguete,
M. Bishai,
S. Blyth,
R. L. Brown,
I. Butorov,
G. F. Cao,
J. Cao,
R. Carr,
Y. L. Chan,
J. F. Chang,
Y. Chang,
C. Chasman,
H. S. Chen,
H. Y. Chen,
S. J. Chen,
S. M. Chen,
X. C. Chen,
X. H. Chen,
Y. Chen,
Y. X. Chen,
Y. P. Cheng
, et al. (214 additional authors not shown)
Abstract:
A measurement of the energy dependence of antineutrino disappearance at the Daya Bay Reactor Neutrino Experiment is reported. Electron antineutrinos ($\overlineν_{e}$) from six $2.9$ GW$_{\rm th}$ reactors were detected with six detectors deployed in two near (effective baselines 512 m and 561 m) and one far (1579 m) underground experimental halls. Using 217 days of data, 41589 (203809 and 92912)…
▽ More
A measurement of the energy dependence of antineutrino disappearance at the Daya Bay Reactor Neutrino Experiment is reported. Electron antineutrinos ($\overlineν_{e}$) from six $2.9$ GW$_{\rm th}$ reactors were detected with six detectors deployed in two near (effective baselines 512 m and 561 m) and one far (1579 m) underground experimental halls. Using 217 days of data, 41589 (203809 and 92912) antineutrino candidates were detected in the far hall (near halls). An improved measurement of the oscillation amplitude $\sin^{2}2θ_{13} = 0.090^{+0.008}_{-0.009} $ and the first direct measurement of the $\overlineν_{e}$ mass-squared difference $|Δm^{2}_{ee}|= (2.59_{-0.20}^{+0.19}) \times 10^{-3}\ {\rm eV}^2 $ is obtained using the observed $\overlineν_{e}$ rates and energy spectra in a three-neutrino framework.
This value of $|Δm^{2}_{ee}|$ is consistent with $|Δm^{2}_{μμ}|$ measured by muon neutrino disappearance, supporting the three-flavor oscillation model.
△ Less
Submitted 15 January, 2014; v1 submitted 24 October, 2013;
originally announced October 2013.
-
Assembly and Installation of the Daya Bay Antineutrino Detectors
Authors:
H. R. Band,
R. L. Brown,
R. Carr,
X. C. Chen,
X. H. Chen,
J. J. Cherwinka,
M. C. Chu,
E. Draeger,
D. A. Dwyer,
W. R. Edwards,
R. Gill,
J. Goett,
L. S. Greenler,
W. Q. Gu,
W. S. He,
K. M. Heeger,
Y. K. Heng,
P. Hinrichs,
T. H. Ho,
M. Hoff,
Y. B. Hsiung,
Y. **,
L. Kang,
S. H. Kettell,
M. Kramer
, et al. (44 additional authors not shown)
Abstract:
The Daya Bay reactor antineutrino experiment is designed to make a precision measurement of the neutrino mixing angle theta13, and recently made the definitive discovery of its nonzero value. It utilizes a set of eight, functionally identical antineutrino detectors to measure the reactor flux and spectrum at baselines of 300 - 2000m from the Daya Bay and Ling Ao Nuclear Power Plants. The Daya Bay…
▽ More
The Daya Bay reactor antineutrino experiment is designed to make a precision measurement of the neutrino mixing angle theta13, and recently made the definitive discovery of its nonzero value. It utilizes a set of eight, functionally identical antineutrino detectors to measure the reactor flux and spectrum at baselines of 300 - 2000m from the Daya Bay and Ling Ao Nuclear Power Plants. The Daya Bay antineutrino detectors were built in an above-ground facility and deployed side-by-side at three underground experimental sites near and far from the nuclear reactors. This configuration allows the experiment to make a precision measurement of reactor antineutrino disappearance over km-long baselines and reduces relative systematic uncertainties between detectors and nuclear reactors. This paper describes the assembly and installation of the Daya Bay antineutrino detectors.
△ Less
Submitted 6 September, 2013;
originally announced September 2013.
-
The Daya Bay Antineutrino Detector Filling System and Liquid Mass Measurement
Authors:
H. R. Band,
J. J. Cherwinka,
E. Draeger,
K. M. Heeger,
P. Hinrichs,
C. A. Lewis,
H. Mattison,
M. C. McFarlane,
D. M. Webber,
W. Wang,
D. Wenman,
T. Wise,
Q. Xiao
Abstract:
The Daya Bay Reactor Neutrino Experiment has measured the neutrino mixing angle θ_{13} to world-leading precision. The experiment uses eight antineutrino detectors filled with 20-tons of gadolinium-doped liquid scintillator to detect antineutrinos emitted from the Daya Bay nuclear power plant through the inverse beta decay reaction. The precision measurement of sin^{2}2θ_{13} relies on the relativ…
▽ More
The Daya Bay Reactor Neutrino Experiment has measured the neutrino mixing angle θ_{13} to world-leading precision. The experiment uses eight antineutrino detectors filled with 20-tons of gadolinium-doped liquid scintillator to detect antineutrinos emitted from the Daya Bay nuclear power plant through the inverse beta decay reaction. The precision measurement of sin^{2}2θ_{13} relies on the relative antineutrino interaction rates between detectors at near (400 m) and far (roughly 1.8 km) distances from the nuclear reactors. The measured interaction rate in each detector is directly proportional to the number of protons in the liquid scintillator target. A precision detector filling system was developed to simultaneously fill the three liquid zones of the antineutrino detectors and measure the relative target mass between detectors to <0.02%. This paper describes the design, operation, and performance of the system and the resulting precision measurement of the detectors' target liquid masses.
△ Less
Submitted 9 November, 2013; v1 submitted 3 July, 2013;
originally announced July 2013.
-
Improved Measurement of Electron Antineutrino Disappearance at Daya Bay
Authors:
Daya Bay Collaboration,
F. P. An,
Q. An,
J. Z. Bai,
A. B. Balantekin,
H. R. Band,
W. Beriguete,
M. Bishai,
S. Blyth,
R. L. Brown,
G. F. Cao,
J. Cao,
R. Carr,
W. T. Chan,
J. F. Chang,
Y. Chang,
C. Chasman,
H. S. Chen,
H. Y. Chen,
S. J. Chen,
S. M. Chen,
X. C. Chen,
X. H. Chen,
X. S. Chen,
Y. Chen
, et al. (207 additional authors not shown)
Abstract:
We report an improved measurement of the neutrino mixing angle $θ_{13}$ from the Daya Bay Reactor Neutrino Experiment. We exclude a zero value for $\sin^22θ_{13}$ with a significance of 7.7 standard deviations. Electron antineutrinos from six reactors of 2.9 GW$_{\rm th}$ were detected in six antineutrino detectors deployed in two near (flux-weighted baselines of 470 m and 576 m) and one far (1648…
▽ More
We report an improved measurement of the neutrino mixing angle $θ_{13}$ from the Daya Bay Reactor Neutrino Experiment. We exclude a zero value for $\sin^22θ_{13}$ with a significance of 7.7 standard deviations. Electron antineutrinos from six reactors of 2.9 GW$_{\rm th}$ were detected in six antineutrino detectors deployed in two near (flux-weighted baselines of 470 m and 576 m) and one far (1648 m) underground experimental halls. Using 139 days of data, 28909 (205308) electron antineutrino candidates were detected at the far hall (near halls). The ratio of the observed to the expected number of antineutrinos assuming no oscillations at the far hall is $0.944\pm 0.007({\rm stat.}) \pm 0.003({\rm syst.})$. An analysis of the relative rates in six detectors finds $\sin^22θ_{13}=0.089\pm 0.010({\rm stat.})\pm0.005({\rm syst.})$ in a three-neutrino framework.
△ Less
Submitted 17 November, 2012; v1 submitted 23 October, 2012;
originally announced October 2012.
-
Target Mass Monitoring and Instrumentation in the Daya Bay Antineutrino Detectors
Authors:
Henry R. Band,
Jeffrey J. Cherwinka,
Lee S. Greenler,
Karsten M. Heeger,
Paul Hinrichs,
Li Kang,
Christine A. Lewis,
Shanfeng Li,
Shengxin Lin,
Michael C. McFarlane,
Wei Wang,
David M. Webber,
Yadong Wei,
Thomas S. Wise,
Qiang Xiao,
Li Yang,
Zhijian Zhang
Abstract:
The Daya Bay experiment measures sin^2 2θ_13 using functionally identical antineutrino detectors located at distances of 300 to 2000 meters from the Daya Bay nuclear power complex. Each detector consists of three nested fluid volumes surrounded by photomultiplier tubes. These volumes are coupled to overflow tanks on top of the detector to allow for thermal expansion of the liquid. Antineutrinos ar…
▽ More
The Daya Bay experiment measures sin^2 2θ_13 using functionally identical antineutrino detectors located at distances of 300 to 2000 meters from the Daya Bay nuclear power complex. Each detector consists of three nested fluid volumes surrounded by photomultiplier tubes. These volumes are coupled to overflow tanks on top of the detector to allow for thermal expansion of the liquid. Antineutrinos are detected through the inverse beta decay reaction on the proton-rich scintillator target. A precise and continuous measurement of the detector's central target mass is achieved by monitoring the the fluid level in the overflow tanks with cameras and ultrasonic and capacitive sensors. In addition, the monitoring system records detector temperature and levelness at multiple positions. This monitoring information allows the precise determination of the detectors' effective number of target protons during data taking. We present the design, calibration, installation and in-situ tests of the Daya Bay real-time antineutrino detector monitoring sensors and readout electronics.
△ Less
Submitted 4 March, 2013; v1 submitted 29 June, 2012;
originally announced June 2012.
-
Low-Background Monitoring Cameras for the Daya Bay Antineutrino Detectors
Authors:
H. R. Band,
J. J. Cherwinka,
K. M. Heeger,
P. Hinrichs,
M. C. McFarlane,
W. Wang,
D. M. Webber,
T. Wise,
Q. Xiao
Abstract:
The Daya Bay Reactor Neutrino Experiment is designed to measure the neutrino mixing angle theta13 to world-leading precision. The experiment deploys identical antineutrino detectors at distances of 400-1900m from six reactors in Daya Bay, China. Each detector incorporates two general-purpose monitoring cameras to ensure their safe construction, transportation and operation. The cameras must meet u…
▽ More
The Daya Bay Reactor Neutrino Experiment is designed to measure the neutrino mixing angle theta13 to world-leading precision. The experiment deploys identical antineutrino detectors at distances of 400-1900m from six reactors in Daya Bay, China. Each detector incorporates two general-purpose monitoring cameras to ensure their safe construction, transportation and operation. The cameras must meet usage goals while satisfying stringent constraints on radioactivity, materials compatibility, interference and reliability. This article describes the system design, integration, operation and performance.
△ Less
Submitted 14 June, 2012; v1 submitted 16 April, 2012;
originally announced April 2012.
-
Observation of electron-antineutrino disappearance at Daya Bay
Authors:
F. P. An,
J. Z. Bai,
A. B. Balantekin,
H. R. Band,
D. Beavis,
W. Beriguete,
M. Bishai,
S. Blyth,
K. Boddy,
R. L. Brown,
B. Cai,
G. F. Cao,
J. Cao,
R. Carr,
W. T. Chan,
J. F. Chang,
Y. Chang,
C. Chasman,
H. S. Chen,
H. Y. Chen,
S. J. Chen,
S. M. Chen,
X. C. Chen,
X. H. Chen,
X. S. Chen
, et al. (246 additional authors not shown)
Abstract:
The Daya Bay Reactor Neutrino Experiment has measured a non-zero value for the neutrino mixing angle $θ_{13}$ with a significance of 5.2 standard deviations. Antineutrinos from six 2.9 GW$_{\rm th}$ reactors were detected in six antineutrino detectors deployed in two near (flux-weighted baseline 470 m and 576 m) and one far (1648 m) underground experimental halls. With a 43,000 ton-GW_{\rm th}-day…
▽ More
The Daya Bay Reactor Neutrino Experiment has measured a non-zero value for the neutrino mixing angle $θ_{13}$ with a significance of 5.2 standard deviations. Antineutrinos from six 2.9 GW$_{\rm th}$ reactors were detected in six antineutrino detectors deployed in two near (flux-weighted baseline 470 m and 576 m) and one far (1648 m) underground experimental halls. With a 43,000 ton-GW_{\rm th}-day livetime exposure in 55 days, 10416 (80376) electron antineutrino candidates were detected at the far hall (near halls). The ratio of the observed to expected number of antineutrinos at the far hall is $R=0.940\pm 0.011({\rm stat}) \pm 0.004({\rm syst})$. A rate-only analysis finds $\sin^22θ_{13}=0.092\pm 0.016({\rm stat})\pm0.005({\rm syst})$ in a three-neutrino framework.
△ Less
Submitted 2 April, 2012; v1 submitted 7 March, 2012;
originally announced March 2012.
-
A side-by-side comparison of Daya Bay antineutrino detectors
Authors:
Daya Bay Collaboration,
F. P. An,
Q. An,
J. Z. Bai,
A. B. Balantekin,
H. R. Band,
W. Beriguete,
M. Bishai,
S. Blyth,
R. L. Brown,
G. F. Cao,
J. Cao,
R. Carr,
J. F. Chang,
Y. Chang,
C. Chasman,
H. S. Chen,
S. J. Chen,
S. M. Chen,
X. C. Chen,
X. H. Chen,
X. S. Chen,
Y. Chen,
J. J. Cherwinka,
M. C. Chu
, et al. (218 additional authors not shown)
Abstract:
The Daya Bay Reactor Neutrino Experiment is designed to determine precisely the neutrino mixing angle $θ_{13}$ with a sensitivity better than 0.01 in the parameter sin$^22θ_{13}$ at the 90% confidence level. To achieve this goal, the collaboration will build eight functionally identical antineutrino detectors. The first two detectors have been constructed, installed and commissioned in Experimenta…
▽ More
The Daya Bay Reactor Neutrino Experiment is designed to determine precisely the neutrino mixing angle $θ_{13}$ with a sensitivity better than 0.01 in the parameter sin$^22θ_{13}$ at the 90% confidence level. To achieve this goal, the collaboration will build eight functionally identical antineutrino detectors. The first two detectors have been constructed, installed and commissioned in Experimental Hall 1, with steady data-taking beginning September 23, 2011. A comparison of the data collected over the subsequent three months indicates that the detectors are functionally identical, and that detector-related systematic uncertainties exceed requirements.
△ Less
Submitted 28 February, 2012;
originally announced February 2012.