-
Analysis of atomic-clock data to constrain variations of fundamental constants
Authors:
Nathaniel Sherrill,
Adam O. Parsons,
Charles F. A. Baynham,
William Bowden,
E. Anne Curtis,
Richard Hendricks,
Ian R. Hill,
Richard Hobson,
Helen S. Margolis,
Billy I. Robertson,
Marco Schioppo,
Krzysztof Szymaniec,
Alexandra Tofful,
Jacob Tunesi,
Rachel M. Godun,
Xavier Calmet
Abstract:
We present a new framework to study the time variation of fundamental constants in a model-independent way. Model independence implies more free parameters than assumed in previous studies. Using data from atomic clocks based on $^{87}$Sr, $^{171}$Yb$^+$ and $^{133}$Cs, we set bounds on parameters controlling the variation of the fine-structure constant, $α$, and the electron-to-proton mass ratio,…
▽ More
We present a new framework to study the time variation of fundamental constants in a model-independent way. Model independence implies more free parameters than assumed in previous studies. Using data from atomic clocks based on $^{87}$Sr, $^{171}$Yb$^+$ and $^{133}$Cs, we set bounds on parameters controlling the variation of the fine-structure constant, $α$, and the electron-to-proton mass ratio, $μ$. We consider variations on timescales ranging from a minute to almost a day. In addition, we use our results to derive some of the tightest limits to date on the parameter space of models of ultralight dark matter and axion-like particles.
△ Less
Submitted 15 December, 2023; v1 submitted 9 February, 2023;
originally announced February 2023.
-
Measuring the stability of fundamental constants with a network of clocks
Authors:
G. Barontini,
L. Blackburn,
V. Boyer,
F. Butuc-Mayer,
X. Calmet,
J. R. Crespo Lopez-Urrutia,
E. A. Curtis,
B. Darquie,
J. Dunningham,
N. J. Fitch,
E. M. Forgan,
K. Georgiou,
P. Gill,
R. M. Godun,
J. Goldwin,
V. Guarrera,
A. C. Harwood,
I. R. Hill,
R. J. Hendricks,
M. Jeong,
M. Y. H. Johnson,
M. Keller,
L. P. Kozhiparambil Sajith,
F. Kuipers,
H. S. Margolis
, et al. (19 additional authors not shown)
Abstract:
The detection of variations of fundamental constants of the Standard Model would provide us with compelling evidence of new physics, and could lift the veil on the nature of dark matter and dark energy. In this work, we discuss how a network of atomic and molecular clocks can be used to look for such variations with unprecedented sensitivity over a wide range of time scales. This is precisely the…
▽ More
The detection of variations of fundamental constants of the Standard Model would provide us with compelling evidence of new physics, and could lift the veil on the nature of dark matter and dark energy. In this work, we discuss how a network of atomic and molecular clocks can be used to look for such variations with unprecedented sensitivity over a wide range of time scales. This is precisely the goal of the recently launched QSNET project: A network of clocks for measuring the stability of fundamental constants. QSNET will include state-of-the-art atomic clocks, but will also develop next-generation molecular and highly charged ion clocks with enhanced sensitivity to variations of fundamental constants. We describe the technological and scientific aims of QSNET and evaluate its expected performance. We show that in the range of parameters probed by QSNET, either we will discover new physics, or we will impose new constraints on violations of fundamental symmetries and a range of theories beyond the Standard Model, including dark matter and dark energy models.
△ Less
Submitted 11 May, 2022; v1 submitted 20 December, 2021;
originally announced December 2021.
-
QSNET, a network of clocks for measuring the stability of fundamental constants
Authors:
G. Barontini,
V. Boyer,
X. Calmet,
N. J. Fitch,
E. M. Forgan,
R. M. Godun,
J. Goldwin,
V. Guarrera,
I. R. Hill,
M. Jeong,
M. Keller,
F. Kuipers,
H. S. Margolis,
P. Newman,
L. Prokhorov,
J. Rodewald,
B. E. Sauer,
M. Schioppo,
N. Sherrill,
M. R. Tarbutt,
A. Vecchio,
S. Worm
Abstract:
The QSNET consortium is building a UK network of next-generation atomic and molecular clocks that will achieve unprecedented sensitivity in testing variations of the fine structure constant, $α$, and the electron-to-proton mass ratio, $μ$. This in turn will provide more stringent constraints on a wide range of fundamental and phenomenological theories beyond the Standard Model and on dark matter m…
▽ More
The QSNET consortium is building a UK network of next-generation atomic and molecular clocks that will achieve unprecedented sensitivity in testing variations of the fine structure constant, $α$, and the electron-to-proton mass ratio, $μ$. This in turn will provide more stringent constraints on a wide range of fundamental and phenomenological theories beyond the Standard Model and on dark matter models.
△ Less
Submitted 12 October, 2021;
originally announced October 2021.
-
Improving the Q factor of an optical atomic clock using quantum non-demolition measurement
Authors:
William Bowden,
Alvise Vianello,
Ian R Hill,
Marco Schioppo,
Richard Hobson
Abstract:
Quantum non-demolition (QND) measurement is a remarkable tool for the manipulation of quantum systems. It allows specific information to be extracted while still preserving fragile quantum observables of the system. Here we apply cavity-based QND measurement to an optical lattice clock---a type of atomic clock with unrivalled frequency precision---preserving the quantum coherence of the atoms afte…
▽ More
Quantum non-demolition (QND) measurement is a remarkable tool for the manipulation of quantum systems. It allows specific information to be extracted while still preserving fragile quantum observables of the system. Here we apply cavity-based QND measurement to an optical lattice clock---a type of atomic clock with unrivalled frequency precision---preserving the quantum coherence of the atoms after readout with 80\% fidelity. We apply this technique to stabilise the phase of an ultrastable laser to a coherent atomic state via a series of repeated QND measurements. We exploit the improved phase-coherence of the ultrastable laser to interrogate a separate optical lattice clock, using a Ramsey spectroscopy time extended from 300~ms to 2~s. With this technique we maintain 95\% contrast and observe a seven-fold increase in the clock's \emph{Q} factor to $1.7\times10^{15}$.
△ Less
Submitted 21 October, 2020; v1 submitted 20 October, 2020;
originally announced October 2020.
-
A strontium optical lattice clock with $1 \times 10^{-17}$ uncertainty and measurement of its absolute frequency
Authors:
Richard Hobson,
William Bowden,
Alissa Silva,
Charles F. A. Baynham,
Helen S. Margolis,
Patrick E. G. Baird,
Patrick Gill,
Ian R. Hill
Abstract:
We present a measurement of the absolute frequency of the 5s$^2$ $^1$S$_0$ to 5s5p $^3$P$_0$ transition in $^{87}$Sr, which is a secondary representation of the SI second. We describe the optical lattice clock apparatus used for the measurement, and we focus in detail on how its systematic frequency shifts are evaluated with a total fractional uncertainty of $1 \times 10^{-17}$. Traceability to th…
▽ More
We present a measurement of the absolute frequency of the 5s$^2$ $^1$S$_0$ to 5s5p $^3$P$_0$ transition in $^{87}$Sr, which is a secondary representation of the SI second. We describe the optical lattice clock apparatus used for the measurement, and we focus in detail on how its systematic frequency shifts are evaluated with a total fractional uncertainty of $1 \times 10^{-17}$. Traceability to the International System of Units is provided via comparison to International Atomic Time (TAI). Gathering data over 5- and 15-day periods, with the lattice clock operating on average 74$\%$ of the time, we measure the frequency of the transition to be 429228004229873.1(5) Hz, which corresponds to a fractional uncertainty of $1 \times 10^{-15}$. We describe in detail how this uncertainty arises from the intermediate steps linking the optical frequency standard, through our local time scale UTC(NPL), to an ensemble of primary and secondary frequency standards which steer TAI. The calculated absolute frequency of the transition is in good agreement with recent measurements carried out in other laboratories around the world.
△ Less
Submitted 21 May, 2020;
originally announced May 2020.
-
A mid-infrared magneto-optical trap of metastable strontium for an optical lattice clock
Authors:
Richard Hobson,
William Bowden,
Alvise Vianello,
Ian R. Hill,
Patrick Gill
Abstract:
We report on the realization of a magneto-optical trap (MOT) for metastable strontium operating on the 2.92 $μ$m transition between the energy levels $5s5p~^3\mathrm{P}_2$ and $5s4d~^3\mathrm{D}_3$. The strontium atoms are initially captured in a MOT operating on the 461 nm transition between the energy levels $5s^2~^1\mathrm{S}_0$ and $5s5p~^1\mathrm{P}_1$, prior to being transferred into the met…
▽ More
We report on the realization of a magneto-optical trap (MOT) for metastable strontium operating on the 2.92 $μ$m transition between the energy levels $5s5p~^3\mathrm{P}_2$ and $5s4d~^3\mathrm{D}_3$. The strontium atoms are initially captured in a MOT operating on the 461 nm transition between the energy levels $5s^2~^1\mathrm{S}_0$ and $5s5p~^1\mathrm{P}_1$, prior to being transferred into the metastable MOT and cooled to a final temperature of 6 $μ$K. Challenges arising from aligning the mid-infrared and 461 nm light are mitigated by employing the same pyramid reflector to realize both MOTs. Finally, the 2.92 $μ$m transition is used to realize a full cooling sequence for an optical lattice clock, in which cold samples of $^{87}\mathrm{Sr}$ are loaded into a magic-wavelength optical lattice and initialized in a spin-polarized state to allow high-precision spectroscopy of the $5s^2~^1\mathrm{S}_0$ to $5s5p~^3\mathrm{P}_0$ clock transition.
△ Less
Submitted 15 January, 2020;
originally announced January 2020.
-
Cavity-enhanced non-destructive detection of atoms for an optical lattice clock
Authors:
Richard Hobson,
William Bowden,
Alvise Vianello,
Ian R. Hill,
Patrick Gill
Abstract:
We demonstrate a new method of cavity-enhanced non-destructive detection of atoms for a strontium optical lattice clock. The detection scheme is shown to be linear in atom number up to at least 10,000 atoms, to reject technical noise sources, to achieve signal to noise ratio close to the photon shot noise limit, to provide spatially uniform atom-cavity coupling, and to minimize inhomogeneous ac St…
▽ More
We demonstrate a new method of cavity-enhanced non-destructive detection of atoms for a strontium optical lattice clock. The detection scheme is shown to be linear in atom number up to at least 10,000 atoms, to reject technical noise sources, to achieve signal to noise ratio close to the photon shot noise limit, to provide spatially uniform atom-cavity coupling, and to minimize inhomogeneous ac Stark shifts. These features enable detection of atoms with minimal perturbation to the atomic state, a critical step towards realizing an ultra-high-stability, quantum-enhanced optical lattice clock.
△ Less
Submitted 20 December, 2019;
originally announced December 2019.
-
Direct comparisons of European primary and secondary frequency standards via satellite techniques
Authors:
F. Riedel,
A. Al-Masoudi,
E. Benkler,
S. Dörscher,
V. Gerginov,
C. Grebing,
S. Häfner,
N. Huntemann,
B. Lipphardt,
C. Lisdat,
E. Peik,
D. Piester,
C. Sanner,
C. Tamm,
S. Weyers,
H. Denker,
L. Timmen,
C. Voigt,
D. Calonico,
G. Cerretto,
G. A. Costanzo,
F. Levi,
I. Sesia,
J. Achkar,
J. Guèna
, et al. (24 additional authors not shown)
Abstract:
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taki…
▽ More
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taking into account correlations and gaps in the measurement data, combined overall uncertainties in the range of $1.8 \times 10^{-16}$ to $3.5 \times 10^{-16}$ for the optical clock comparisons were found. The comparison of the fountain clocks yields results with a maximum relative frequency difference of $6.9 \times 10^{-16}$, and combined overall uncertainties in the range of $4.8 \times 10^{-16}$ to $7.7 \times 10^{-16}$.
△ Less
Submitted 9 October, 2019;
originally announced October 2019.
-
A pyramid MOT with integrated optical cavities as a cold atom platform for an optical lattice clock
Authors:
William Bowden,
Richard Hobson,
Ian R. Hill,
Alvise Vianello,
Marco Schioppo,
Alissa Silva,
Helen S. Margolis,
Patrick E. G. Baird,
Patrick Gill
Abstract:
We realize a two-stage, hexagonal pyramid magneto-optical trap (MOT) with strontium, and demonstrate loading of cold atoms into cavity-enhanced 1D and 2D optical lattice traps, all within a single compact assembly of in-vacuum optics. We show that the device is suitable for high-performance quantum technologies, focusing especially on its intended application as a strontium optical lattice clock.…
▽ More
We realize a two-stage, hexagonal pyramid magneto-optical trap (MOT) with strontium, and demonstrate loading of cold atoms into cavity-enhanced 1D and 2D optical lattice traps, all within a single compact assembly of in-vacuum optics. We show that the device is suitable for high-performance quantum technologies, focusing especially on its intended application as a strontium optical lattice clock. We prepare $2\times 10^4$ spin-polarized atoms of $^{87}$Sr in the optical lattice within 500 ms; we observe a vacuum-limited lifetime of atoms in the lattice of 27 s; and we measure a background DC electric field of 12 Vm$^{-1}$ from stray charges, corresponding to a fractional frequency shift of $(-1.2\times 0.8)\times 10^{-18}$ to the strontium clock transition. When used in combination with careful management of the blackbody radiation environment, the device shows potential as a platform for realizing a compact, robust, transportable optical lattice clock with systematic uncertainty at the $10^{-18}$ level.
△ Less
Submitted 31 July, 2019;
originally announced July 2019.
-
Search for transient variations of the fine structure constant and dark matter using fiber-linked optical atomic clocks
Authors:
B. M. Roberts,
P. Delva,
A. Al-Masoudi,
A. Amy-Klein,
C. Bærentsen,
C. F. A. Baynham,
E. Benkler,
S. Bilicki,
S. Bize,
W. Bowden,
J. Calvert,
V. Cambier,
E. Cantin,
E. A. Curtis,
S. Dörscher,
M. Favier,
F. Frank,
P. Gill,
R. M. Godun,
G. Grosche,
C. Guo,
A. Hees,
I. R. Hill,
R. Hobson,
N. Huntemann
, et al. (29 additional authors not shown)
Abstract:
We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in the recorded clock frequency comparisons across the network, we significantly improve the constraints on transient variations of the fine structure constant. For example, we constrain the variation in alpha to <5*10^-17…
▽ More
We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in the recorded clock frequency comparisons across the network, we significantly improve the constraints on transient variations of the fine structure constant. For example, we constrain the variation in alpha to <5*10^-17 for transients of duration 10^3 s. This analysis also presents a possibility to search for dark matter, the mysterious substance hypothesised to explain galaxy dynamics and other astrophysical phenomena that is thought to dominate the matter density of the universe. At the current sensitivity level, we find no evidence for dark matter in the form of topological defects (or, more generally, any macroscopic objects), and we thus place constraints on certain potential couplings between the dark matter and standard model particles, substantially improving upon the existing constraints, particularly for large (>~10^4 km) objects.
△ Less
Submitted 8 July, 2019; v1 submitted 4 July, 2019;
originally announced July 2019.
-
Guidelines for develo** optical clocks with $10^{-18}$ fractional frequency uncertainty
Authors:
Moustafa Abdel-Hafiz,
Piotr Ablewski,
Ali Al-Masoudi,
Héctor Álvarez Martínez,
Petr Balling,
Geoffrey Barwood,
Erik Benkler,
Marcin Bober,
Mateusz Borkowski,
William Bowden,
Roman Ciuryło,
Hubert Cybulski,
Alexandre Didier,
Miroslav Doležal,
Sören Dörscher,
Stephan Falke,
Rachel M. Godun,
Ramiz Hamid,
Ian R. Hill,
Richard Hobson,
Nils Huntemann,
Yann Le Coq,
Rodolphe Le Targat,
Thomas Legero,
Thomas Lindvall
, et al. (20 additional authors not shown)
Abstract:
There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the $10^{-18}$ range, approximately two orders of magnitude better than that of the best caesium primary frequency…
▽ More
There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the $10^{-18}$ range, approximately two orders of magnitude better than that of the best caesium primary frequency standards. This exceptional accuracy and stability is resulting in a growing number of research groups develo** optical clocks. While good review papers covering the topic already exist, more practical guidelines are needed as a complement. The purpose of this document is therefore to provide technical guidance for researchers starting in the field of optical clocks. The target audience includes national metrology institutes (NMIs) wanting to set up optical clocks (or subsystems thereof) and PhD students and postdocs entering the field. Another potential audience is academic groups with experience in atomic physics and atom or ion trap**, but with less experience of time and frequency metrology and optical clock requirements. These guidelines have arisen from the scope of the EMPIR project "Optical clocks with $1 \times 10^{-18}$ uncertainty" (OC18). Therefore, the examples are from European laboratories even though similar work is carried out all over the world. The goal of OC18 was to push the development of optical clocks by improving each of the necessary subsystems: ultrastable lasers, neutral-atom and single-ion traps, and interrogation techniques. This document shares the knowledge acquired by the OC18 project consortium and gives practical guidance on each of these aspects.
△ Less
Submitted 13 August, 2019; v1 submitted 27 June, 2019;
originally announced June 2019.
-
Rydberg Electrometry for Optical Lattice Clocks
Authors:
William Bowden,
Richard Hobson,
Paul Huillery,
Patrick Gill,
Matthew P. A. Jones,
Ian R. Hill
Abstract:
Electrometry is performed using Rydberg states to evaluate the quadratic Stark shift of the $5s^2$ $^1\textrm{S}_0-5s5p$ $^3\textrm{P}_0$ clock transition in strontium. By measuring the Stark shift of the highly excited $5s75d\;^1\textrm{D}_2$ state using electromagnetically induced transparency, we characterize the electric field with sufficient precision to provide tight constraints on the syste…
▽ More
Electrometry is performed using Rydberg states to evaluate the quadratic Stark shift of the $5s^2$ $^1\textrm{S}_0-5s5p$ $^3\textrm{P}_0$ clock transition in strontium. By measuring the Stark shift of the highly excited $5s75d\;^1\textrm{D}_2$ state using electromagnetically induced transparency, we characterize the electric field with sufficient precision to provide tight constraints on the systematic shift to the clock transition. Using the theoretically derived, and experimentally verified, polarizability for this Rydberg state we can measure the residual field with an uncertainty well below $1 \textrm{V} \textrm{m}^{-1}$. This resolution allows us to constrain the fractional frequency uncertainty of the quadratic Stark shift of the clock transition to $2\times10^{-20}$.
△ Less
Submitted 6 June, 2017;
originally announced June 2017.
-
Test of special relativity using a fiber network of optical clocks
Authors:
P. Delva,
J. Lodewyck,
S. Bilicki,
E. Bookjans,
G. Vallet,
R. Le Targat,
P. -E. Pottie,
C. Guerlin,
F. Meynadier,
C. Le Poncin-Lafitte,
O. Lopez,
A. Amy-Klein,
W. -K. Lee,
N. Quintin,
C. Lisdat,
A. Al-Masoudi,
S. Dörscher,
C. Grebing,
G. Grosche,
A. Kuhl,
S. Raupach,
U. Sterr,
I. R. Hill,
R. Hobson,
W. Bowden
, et al. (6 additional authors not shown)
Abstract:
Phase compensated optical fiber links enable high accuracy atomic clocks separated by thousands of kilometers to be compared with unprecedented statistical resolution. By searching for a daily variation of the frequency difference between four strontium optical lattice clocks in different locations throughout Europe connected by such links, we improve upon previous tests of time dilation predicted…
▽ More
Phase compensated optical fiber links enable high accuracy atomic clocks separated by thousands of kilometers to be compared with unprecedented statistical resolution. By searching for a daily variation of the frequency difference between four strontium optical lattice clocks in different locations throughout Europe connected by such links, we improve upon previous tests of time dilation predicted by special relativity. We obtain a constraint on the Robertson--Mansouri--Sexl parameter $|α|\lesssim 1.1 \times10^{-8}$ quantifying a violation of time dilation, thus improving by a factor of around two the best known constraint obtained with Ives--Stilwell type experiments, and by two orders of magnitude the best constraint obtained by comparing atomic clocks. This work is the first of a new generation of tests of fundamental physics using optical clocks and fiber links. As clocks improve, and as fiber links are routinely operated, we expect that the tests initiated in this paper will improve by orders of magnitude in the near future.
△ Less
Submitted 12 June, 2017; v1 submitted 13 March, 2017;
originally announced March 2017.
-
A High-Performance, Low-Cost Laser Shutter using a Piezoelectric Cantilever Actuator
Authors:
W. Bowden,
I. R. Hill,
P. E. G. Baird,
P. Gill
Abstract:
We report the design and characterization of an optical shutter based on a piezoelectric cantilever. Compared to conventional electro-magnetic shutters, the device is intrinsically low power and acoustically quiet. The cantilever position is controlled by a high-voltage op-amp circuit for easy tuning of the range of travel, and mechanical slew rate, which enables a factor of 30 reduction in mechan…
▽ More
We report the design and characterization of an optical shutter based on a piezoelectric cantilever. Compared to conventional electro-magnetic shutters, the device is intrinsically low power and acoustically quiet. The cantilever position is controlled by a high-voltage op-amp circuit for easy tuning of the range of travel, and mechanical slew rate, which enables a factor of 30 reduction in mechanical noise compared to a rapidly switched device. We achieve shuttering rise and fall times of 11 $μ$s, corresponding to mechanical slew rates of 1.3 $\textrm{ ms}^{-1}$, with an timing jitter of less than 1 $μ$s. When used to create optical pulses, we achieve minimum pulse durations of 250 $μ$s. The reliability of the shutter was investigated by operating continuously for one week at 10 Hz switching rate. After this period, neither the shutter delay or actuation speed had changed by a notable amount. We also show that the high-voltage electronics can be easily configured as a versatile low-noise, high-bandwidth piezo driver, well-suited to applications in laser frequency control.
△ Less
Submitted 19 September, 2016;
originally announced September 2016.
-
Development of a strontium optical lattice clock for the SOC mission on the ISS
Authors:
S. Origlia,
S. Schiller,
M. S. Pramod,
L. Smith,
Y. Singh,
W. He,
S. Viswam,
D. Świerad,
J. Hughes,
K. Bongs,
U. Sterr,
Ch. Lisdat,
S. Vogt,
S. Bize,
J. Lodewyck,
R. Le Targat,
D. Holleville,
B. Venon,
P. Gill,
G. Barwood,
I. R. Hill,
Y. Ovchinnikov,
A. Kulosa,
W. Ertmer,
E. -M. Rasel
, et al. (3 additional authors not shown)
Abstract:
The ESA mission "Space Optical Clock" project aims at operating an optical lattice clock on the ISS in approximately 2023. The scientific goals of the mission are to perform tests of fundamental physics, to enable space-assisted relativistic geodesy and to intercompare optical clocks on the ground using microwave and optical links. The performance goal of the space clock is less than…
▽ More
The ESA mission "Space Optical Clock" project aims at operating an optical lattice clock on the ISS in approximately 2023. The scientific goals of the mission are to perform tests of fundamental physics, to enable space-assisted relativistic geodesy and to intercompare optical clocks on the ground using microwave and optical links. The performance goal of the space clock is less than $1 \times 10^{-17}$ uncertainty and $1 \times 10^{-15} τ^{-1/2}$ instability. Within an EU-FP7-funded project, a strontium optical lattice clock demonstrator has been developed. Goal performances are instability below $1 \times 10^{-15} τ^{-1/2}$ and fractional inaccuracy $5 \times 10^{-17}$. For the design of the clock, techniques and approaches suitable for later space application are used, such as modular design, diode lasers, low power consumption subunits, and compact dimensions. The Sr clock apparatus is fully operational, and the clock transition in $^{88}$Sr was observed with linewidth as small as 9 Hz.
△ Less
Submitted 19 March, 2016;
originally announced March 2016.
-
A low maintenance Sr optical lattice clock
Authors:
Ian R. Hill,
Richard Hobson,
William Bowden,
Elizabeth M. Bridge,
Sean Donnellan,
E. Anne Curtis,
Patrick Gill
Abstract:
We describe the Sr optical lattice clock apparatus at NPL with particular emphasis on techniques used to increase reliability and minimise the human requirement in its operation. Central to this is a clock-referenced transfer cavity scheme for the stabilisation of cooling and trap** lasers. We highlight several measures to increase the reliability of the clock with a view towards the realisation…
▽ More
We describe the Sr optical lattice clock apparatus at NPL with particular emphasis on techniques used to increase reliability and minimise the human requirement in its operation. Central to this is a clock-referenced transfer cavity scheme for the stabilisation of cooling and trap** lasers. We highlight several measures to increase the reliability of the clock with a view towards the realisation of an optical time-scale. The clock contributed 502 hours of data over a 25 day period (84% uptime) in a recent measurement campaign with several uninterrupted periods of more than 48 hours. An instability of $2\times10^{-17}$ was reached after $10^5$ s of averaging in an interleaved self-comparison of the clock.
△ Less
Submitted 18 February, 2016;
originally announced February 2016.
-
Modified hyper-Ramsey methods for the elimination of probe shifts in optical clocks
Authors:
R. Hobson,
W. Bowden,
S. A. King,
P. E. G. Baird,
I. R. Hill,
P. Gill
Abstract:
We develop a method of modified hyper-Ramsey spectroscopy in optical clocks, achieving complete immunity to the frequency shifts induced by the probing fields themselves. Using particular pulse sequences with tailored phases, frequencies, and durations, we can derive an error signal centered exactly at the unperturbed atomic resonance with a steep discriminant which is robust against variations in…
▽ More
We develop a method of modified hyper-Ramsey spectroscopy in optical clocks, achieving complete immunity to the frequency shifts induced by the probing fields themselves. Using particular pulse sequences with tailored phases, frequencies, and durations, we can derive an error signal centered exactly at the unperturbed atomic resonance with a steep discriminant which is robust against variations in the probe shift. We experimentally investigate the scheme using the magnetically-induced $^1$S$_0- ^3$P$_0$ transition in $^{88}$Sr, demonstrating automatic suppression of a sizeable \num{2e-13} probe Stark shift to below \num{1e-16} even with very large errors in shift compensation.
△ Less
Submitted 3 November, 2015; v1 submitted 27 October, 2015;
originally announced October 2015.
-
Development of a strontium optical lattice clock for the SOC mission on the ISS
Authors:
K. Bongs,
Y. Singh,
L. Smith,
W. He,
O. Kock,
D. Swierad,
J. Hughes,
S. Schiller,
S. Alighanbari,
S. Origlia,
S. Vogt,
U. Sterr,
Ch. Lisdat,
R. Le Targat,
J. Lodewyck,
D. Holleville,
B. Venon,
S. Bize,
G. P. Barwood,
P. Gill,
I. R. Hill,
Y. B. Ovchinnikov,
N. Poli,
G. M. Tino,
J. Stuhler
, et al. (2 additional authors not shown)
Abstract:
Ultra-precise optical clocks in space will allow new studies in fundamental physics and astronomy. Within an European Space Agency (ESA) program, the Space Optical Clocks (SOC) project aims to install and to operate an optical lattice clock on the International Space Station (ISS) towards the end of this decade. It would be a natural follow-on to the ACES mission, improving its performance by at l…
▽ More
Ultra-precise optical clocks in space will allow new studies in fundamental physics and astronomy. Within an European Space Agency (ESA) program, the Space Optical Clocks (SOC) project aims to install and to operate an optical lattice clock on the International Space Station (ISS) towards the end of this decade. It would be a natural follow-on to the ACES mission, improving its performance by at least one order of magnitude. The payload is planned to include an optical lattice clock, as well as a frequency comb, a microwave link, and an optical link for comparisons of the ISS clock with ground clocks located in several countries and continents. Within the EU-FP7-SPACE-2010-1 project no. 263500, during the years 2011-2015 a compact, modular and robust strontium lattice optical clock demonstrator has been developed. Goal performance is a fractional frequency instability below 1x10^{-15}, tau^{-1/2} and a fractional inaccuracy below 5x10^{-17}. Here we describe the current status of the apparatus' development, including the laser subsystems. Robust preparation of cold {88}^Sr atoms in a second stage magneto-optical trap (MOT) is achieved.
△ Less
Submitted 29 March, 2015;
originally announced March 2015.
-
Zeeman Slowers for Strontium based on Permanent Magnets
Authors:
Ian R. Hill,
Yuri B. Ovchinnikov,
Elizabeth M. Bridge,
E. Anne Curtis,
Patrick Gill
Abstract:
We present the design, construction, and characterisation of longitudinal- and transverse-field Zeeman slowers, based on arrays of permanent magnets, for slowing thermal beams of atomic Sr. The slowers are optimised for operation with deceleration related to the local laser intensity (by the parameter $ε$), which uses more effectively the available laser power, in contrast to the usual constant de…
▽ More
We present the design, construction, and characterisation of longitudinal- and transverse-field Zeeman slowers, based on arrays of permanent magnets, for slowing thermal beams of atomic Sr. The slowers are optimised for operation with deceleration related to the local laser intensity (by the parameter $ε$), which uses more effectively the available laser power, in contrast to the usual constant deceleration mode. Slowing efficiencies of up to $\approx$ $18$ $%$ are realised and compared to those predicted by modelling. We highlight the transverse-field slower, which is compact, highly tunable, light-weight, and requires no electrical power, as a simple solution to slowing Sr, well-suited to spaceborne application. For $^{88}$Sr we achieve a slow-atom flux of around $6\times 10^9$ atoms$\,$s$^{-1}$ at $30$ ms$^{-1}$, loading approximately $5\times 10^8$ atoms in to a magneto-optical-trap (MOT), and capture all isotopes in approximate relative natural abundances.
△ Less
Submitted 21 February, 2014;
originally announced February 2014.